993 resultados para implant impression technique
Resumo:
We recently described a sonication technique for the diagnosis of prosthetic knee and hip infections. We compared periprosthetic tissue culture to implant sonication followed by sonicate fluid culture for the diagnosis of prosthetic shoulder infection. One hundred thirty-six patients undergoing arthroplasty revision or resection were studied; 33 had definite prosthetic shoulder infections and 2 had probable prosthetic shoulder infections. Sonicate fluid culture was more sensitive than periprosthetic tissue culture for the detection of definite prosthetic shoulder infection (66.7 and 54.5%, respectively; P = 0.046). The specificities were similar (98.0% and 95.1%, respectively; P = 0.26). Propionibacterium acnes was the commonest species detected among culture-positive definite prosthetic shoulder infection cases by periprosthetic tissue culture (38.9%) and sonicate fluid culture (40.9%). All subjects from whom P. acnes was isolated from sonicate fluid were male. We conclude that sonicate fluid culture is useful for the diagnosis of prosthetic shoulder infection.
Resumo:
A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.
Resumo:
La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.
Resumo:
Although the biodimensional anatomical expander-implant system (BEIS) is a reliable technique, little information has been available regarding outcome following nipple-areola sparing mastectomy (NSM). To perform the resection of glandular tissue, while improving the surgical access and maintaining the nipple-areola vascularization we have developed a new approach for NSM based on the double concentric periareolar incision (DCPI). The purpose of this study is to analyze the feasibility, surgical planning and its outcome following NSM. 18 patients underwent NSM reconstructions. Mean time of follow-up was 29 months. The technique was indicated in patients with small/moderate volume breasts. Flap complications were evaluated and information on aesthetic results and patient satisfaction were collected. 83.3% had tumors measuring 2 cm or less (T1) and 72.1% were stage 0 and 1. All patients presented peripherally tumors located (at least 5 cm from the nipple). Skin complications occurred in 11.1%. One patient (5.5%) presented small skin necrosis and a wound dehiscence was observed in one patient (5.5%). The aesthetic result was good/very good in 94.4 percent and the majority of patients were very satisfied/satisfied. No local recurrences were observed. All complications except one were treated by a conservative approach. DCPI-BEIS is a simple and reliable technique for NSM reconstruction. The success depends on patient selection, coordinated planning with the oncologic surgeon and careful intra-operative and post-operative management. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Computed tomographic scanning is a precise, noinvasive surveying technique that enables the professionals to improve the precision of implant placement by building a prototype that allows the confection of surgical guides. The authors present a clinical case of anterior tooth rehabilitation with frozen homogenous bone graft and immediately loaded titanium implant using computer-guided surgery. A multislice computed tomography was realized, and a prototype was built. All the procedures were previously realized in the prototype before started in the patient. This technique allows a better surgical planning, makes the procedures more accurate, and reduces surgery time.
Resumo:
The aims of this article were to describe the surgical technique of the inferior alveolar nerve lateralization followed by implant installation by means of a clinical report and also to discuss the importance of an adequate surgical and prosthetic planning for atrophic posterior mandible rehabilitation.
Resumo:
This case report describes a technique that uses a palatal mucosal graft and an acrylic resin postoperative stent in an attempt to increase the layer of keratinized tissue around osseointegrated implants in an atrophic mandible. During second-stage surgery a split-thickness labial flap is reflected and apically repositioned by being sutured onto the periosteum and connective tissue. A palatal mucosal graft is then sutured onto the recipient site. The stent is worn for at least 4 weeks following surgery. This procedure helps to eliminate mobility of the mucosa in the area, deepen the vestibule, and prevent muscle reinsertion. (Int J Periodontics Restorative Dent 2008;28:617-623.)
Resumo:
Background. Severely resorbed mandibles often present a short band of keratinized tissue associated with a shallow vestibule. As a result, prominent muscle insertions are present, especially in the mental region of the mandible. This case report describes the deepening of the vestibular sulcus in an atrophic mandible by combining free gingival grafts harvested from the palate and a postoperative acrylic resin stent screwed on osseointegrated implants placed at the anterior region of the mandible.Study design. During the second-stage surgery, a split-thickness labial flap was reflected and apically sutured onto the periosteum. Two free gingival grafts were obtained and then sutured at this recipient site. A previously custom-made acrylic stent was then screwed onto the most distally positioned implants. To document the procedure's stability over time, a metal ball was placed in the most apical part of the vestibule and standardized cephalometric radiographs were taken before and 6 months after the procedure. Linear measurements of vestibular depths over the observation time were realized using specific software for radiographic analysis.Results. The proposed technique augmented the band of attached masticatory mucosa, deepened the vestibule and prevented the muscle reinsertion. The difference between the 2 measurements of vestibular depths was 9.39 mm (initial 20.88 mm, final 11.49 mm) after a 6-month postoperative period.Conclusion. The technique, in combination with palatal mucosal graft and use of a postoperative stent, decreased the pull of mentalis muscle and provided a peri-implantally stable soft tissue around implants. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: e7-e14)
Resumo:
Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.
Resumo:
The authors describe a literature revision on assessing stresses in buccomaxillary prostheses photoelasticity, finite element technique, and extensometry. They describe the techniques and the importance for use of each method in buccomaxillary prostheses with implants and the need of accomplishing more studies in this scarce literary area.
Resumo:
The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.
Resumo:
Purpose: This study tested the hypothesis that early integration of plateau root form endosseous implants is significantly affected by surgical drilling technique.Materials and Methods: Sixty-four implants were bilaterally placed in the diaphysial radius of 8 beagles and remained 2 and 4 weeks in vivo. Half the implants had an alumina-blasted/acid-etched surface and the other half a surface coated with calcium phosphate. Half the implants with the 2 surface types were drilled at 50 rpm without saline irrigation and the other half were drilled at 900 rpm under abundant irrigation. After euthanasia, the implants in bone were nondecalcified and referred for histologic analysis. Bone-to-implant contact, bone area fraction occupancy, and the distance from the tip of the plateau to pristine cortical bone were measured. Statistical analyses were performed by analysis of variance at a 95% level of significance considering implant surface, time in vivo, and drilling speed as independent variables and bone-to-implant contact, bone area fraction occupancy, and distance from the tip of the plateau to pristine cortical bone as dependent variables.Results: The results showed that both techniques led to implant integration and intimate contact between bone and the 2 implant surfaces. A significant increase in bone-to-implant contact and bone area fraction occupancy was observed as time elapsed at 2 and 4 weeks and for the calcium phosphate-coated implant surface compared with the alumina-blasted/acid-etched surface.Conclusions: Because the surgical drilling technique did not affect the early integration of plateau root form implants, the hypothesis was refuted. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69: 2158-2163, 2011
Resumo:
Aim: This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of all implant that is to be osseointegrated.Case Report. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve., which are responsible for the anterior upper-tooth pulp, the periodontium vascularization. and the innervation. Front the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation.Conclusion: Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient. (Implant Dent 2009;18:473-479)
Resumo:
Objectives: The aim of this study was to compare two methods for the evaluation of periapical lesion changes following endodontic therapy (digital subtraction technique and morphometric analysis) by outlining the radiolucent area.Methods: 13 human anterior teeth with pulp necrosis and chronic periapical lesions were used. Periapical radiographs were taken immediately after endodontic therapy (0) and then 2 months, 4 months and 6 months post treatment, using an intraoral radiographic film holder stabilized with impression material. The films were processed in a standard manner and the digitized images were submitted to digital subtraction using Adobe Photoshop 6.0. New bone formation or bone resorption areas were then measured. In the morphometric analysis, the periapical lesions were outlined using VixWin 2000 and the area (in square millimetres) was recorded. The obtained data were submitted to agreement analysis for comparison of the two techniques.Results: There was no correlation between the areas of radiographic changes detected by digital subtraction and periapical lesion outline (r=0.02-0.45). The new bone formation areas observed by digital subtraction presented higher values, with bone changes being especially evident in the 2 month follow-up radiographs, which suggests a higher sensitivity for this method.Conclusions: Both methods are suitable for the evaluation of periapical lesion changes, but the digital subtraction technique is more sensitive for detecting radiographic periapical changes. Dentomaxillofacial Radiology (2009) 38, 438-444. doi: 10.1259/dmfr/53304677
Resumo:
The purpose of this study was to observe the clinical outcome of bone spreading and standardized dilation of horizontally resorbed bone during immediate implant placement using a "screw-type" configuration of expansion and threadformers. Fifty-three patients were included in this study, and 41 edentulous areas in anterior and posterior maxillas were treated. Sixty-eight implants were placed using an insertion torque of at least 40 Ncm. Abutments were delivered 4 to 6 months after implant placement. The overall failure percentage was 4.41% (3 failures). A retrieved analysis of I implant removed at 3 years after placement demonstrated bone resorption down to the level of the third thread. The bone spreader technique is different from Summers' osteotome, both in clinical use and in armamentarium. The main advantage of the crest-expanding technique is that it is a less invasive procedure; the facial wall expands after the medullary bone is compressed against the cortical wall. Within the limits of this preliminary study, the cumulative survival rate for this method of implant placement is 95.58% at 3 years. This study confirms that a bone spreader used in the maxilla shows an unusually low failure rate after 3 years.