776 resultados para heart atrium fibrillation
Resumo:
OBJECTIVES This study sought to evaluate the relationship between fibrosis imaged by delayed-enhancement (DE) magnetic resonance imaging (MRI) and atrial electrograms (Egms) in persistent atrial fibrillation (AF). BACKGROUND Atrial fractionated Egms are strongly related to slow anisotropic conduction. Their relationship to atrial fibrosis has not yet been investigated. METHODS Atrial high-resolution MRI of 18 patients with persistent AF (11 long-lasting persistent AF) was registered with mapping geometry (NavX electro-anatomical system (version 8.0, St. Jude Medical, St. Paul, Minnesota)). DE areas were categorized as dense or patchy, depending on their DE content. Left atrial Egms during AF were acquired using a high-density, 20-pole catheter (514 ± 77 sites/map). Fractionation, organization/regularity, local mean cycle length (CL), and voltage were analyzed with regard to DE. RESULTS Patients with long-lasting persistent versus persistent AF had larger left atrial (LA) surface area (134 ± 38 cm(2) vs. 98 ± 9 cm(2), p = 0.02), a higher amount of atrial DE (70 ± 16 cm(2) vs. 49 ± 10 cm(2), p = 0.01), more complex fractionated atrial Egm (CFAE) extent (54 ± 16 cm(2) vs. 28 ± 15 cm(2), p = 0.02), and a shorter baseline AF CL (147 ± 10 ms vs. 182 ± 14 ms, p = 0.01). Continuous CFAE (CFEmean [NavX algorithm that quantifies Egm fractionation] <80 ms) occupied 38 ± 19% of total LA surface area. Dense DE was detected at the left posterior left atrium. In contrast, the right posterior left atrium contained predominantly patchy DE. Most CFAE (48 ± 14%) occurred at non-DE LA sites, followed by 41 ± 12% CFAE at patchy DE and 11 ± 6% at dense DE regions (p = 0.005 and p = 0.008, respectively); 19 ± 6% CFAE sites occurred at border zones of dense DE. Egms were less fractionated, with longer CL and lower voltage at dense DE versus non-DE regions: CFEmean: 97 ms versus 76 ms, p < 0.0001; local CL: 153 ms versus 143 ms, p < 0.0001; mean voltage: 0.63 mV versus 0.86 mV, p < 0.0001. CONCLUSIONS Atrial fibrosis as defined by DE MRI is associated with slower and more organized electrical activity but with lower voltage than healthy atrial areas. Ninety percent of continuous CFAE sites occur at non-DE and patchy DE LA sites. These findings are important when choosing the ablation strategy in persistent AF.
Resumo:
AIMS Loss-of-function mutations in the SCN5A-encoded sodium channel SCN5A or Nav1.5 have been identified in idiopathic ventricular fibrillation (IVF) in the absence of Brugada syndrome phenotype. Nav1.5 is regulated by four sodium channel auxiliary beta subunits. Here, we report a case with IVF and a novel mutation in the SCN3B-encoded sodium channel beta subunit Navbeta3 that causes a loss of function of Nav1.5 channels in vitro. METHODS AND RESULTS Comprehensive open reading frame mutational analysis of KCNQ1, KCNH2, SCN5A, KCNE1, KCNE2, GPD1L, four sodium channel beta subunit genes (SCN1-4B), and targeted scan of RYR2 was performed. A novel missense mutation, Navbeta3-V54G, was identified in a 20-year-old male following witnessed collapse and defibrillation from VF. The ECG exhibited epsilon waves, and imaging studies demonstrated a structurally normal heart. The mutated residue was highly conserved across species, localized to the Navbeta3 extracellular domain, and absent in 800 reference alleles. We found that HEK-293 cells had endogenous Navbeta3, but COS cells did not. Co-expression of Nav1.5 with Navbeta3-V54G (with or without co-expression of the Navbeta1 subunit) in both HEK-293 cells and COS cells revealed a significant decrease in peak sodium current and a positive shift of inactivation compared with WT. Co-immunoprecipitation experiments showed association of Navbeta3 with Nav1.5, and immunocytochemistry demonstrated a dramatic decrease in trafficking to the plasma membrane when co-expressed with mutant Navbeta3-V54G. CONCLUSION This study provides molecular and cellular evidence implicating mutations in Navbeta3 as a cause of IVF.
Resumo:
Data on short and long term efficacy and safety of d,l sotalol in patients with atrial fibrillation or atrial flutter is limited. The aims of this study were to (1) assess the antiarrhythmic efficacy of d,l sotalol maintaining normal sinus rhythm in patients with refractory atrial fibrillation or flutter, (2) evaluate the efficacy of d,l sotalol in preventing recurrences of paroxysmal atrial fibrillation or flutter, (3) evaluate the control of ventricular rate in patients with paroxysmal or refractory atrial fibrillation or flutter unsuccessfully treated with other antiarrhythmic agents, (4) determine predictors of efficacy (5) assess the safety of d,l sotalol in this setting. Two hundred patients with chronic or paroxysmal atrial fibrillation or atrial flutter or both, who had failed one to six previous antiarrhythmic drug trials were treated with d,l sotalol 80 to 440 mg/day orally. Fifty four percent was female, age 47 +/- 16 years (range 7-79), follow up period 7 +/- 7 months (range 1 to 14 months), 79% of patients had the arrhythmia for more than one year. The atrial fibrillation in 37.5% of patients was chronic and paroxysmal in 23.5. The atrial flutter was chronic in 31% of patients and paroxysmal in 8%. Eighty two percent of patients was in functional class I (NYHA) and 82% had cardiac heart disease: left atrial (LA) size 44 +/- 10 mm, right atrial (RA) size 37 +/- 7 mm and left ventricular ejection fraction (LVEF) 58 +/- 8%. Total success was achieved in 58% of patients (atrial fibrillation 40% and 18% in atrial flutter), partial success in 38% (atrial fibrillation in 18% and 20% in atrial flutter) and 4% of patients failure. It was p < 0.07 when compared total success vs partial success among atrial fibrillation and atrial flutter groups. Patients with cardiac heart disease responded worst (p = 0.10) to the drug than those without it, specially if the heart was dilated. We concluded that d,l sotalol has moderate efficacy to convert and maintain normal sinus rhythm, as well as it acts controlling paroxysmal relapses and ventricular heart rate.
Resumo:
BACKGROUND The objective of this study was to assess the incidence and impact of asymptomatic arrhythmia in patients with highly symptomatic atrial fibrillation (AF) who qualified for radiofrequency (RF) catheter ablation. METHODS AND RESULTS In this prospective study, 114 patients with at least 3 documented AF episodes together with corresponding symptoms and an ineffective trial of at least 1 antiarrhythmic drug were selected for RF ablation. With the use of CARTO, circumferential lesions around the pulmonary veins and linear lesions at the roof of the left atrium and along the left atrial isthmus were placed. A continuous, 7-day, Holter session was recorded before ablation, right after ablation, and after 3, 6, and 12 months of follow-up. During each 7-day Holter monitoring, the patients recorded quality and duration of any complaints by using a detailed symptom log. More than 70,000 hours of ECG recording were analyzed. In the 7-day Holter records before ablation, 92 of 114 patients (81%) had documented AF episodes. All episodes were symptomatic in 35 patients (38%). In 52 patients (57%), both symptomatic and asymptomatic episodes were recorded, whereas in 5 patients (5%), all documented AF episodes were asymptomatic. After ablation, the percentage of patients with only asymptomatic AF recurrences increased to 37% (P<0.05) at the 6-month follow-up. An analysis of patient characteristics and arrhythmia patterns failed to identify a specific subset who were at high risk for the development of asymptomatic AF. CONCLUSIONS Even in patients presenting with highly symptomatic AF, asymptomatic episodes may occur and significantly increase after catheter ablation. A symptom-only-based follow-up would substantially overestimate the success rate. Objective measures such as long-term Holter monitoring are needed to identify asymptomatic AF recurrences after ablation.
Resumo:
UNLABELLED Topography of the esophagus in atrial fibrillation ablation. INTRODUCTION The close anatomic relationship of the posterior wall of the left atrium (LA) and the thermosensitive esophagus creates a potential hazard in catheter ablation procedures. METHODS AND RESULTS In 30 patients (pts) with atrial fibrillation (AF) undergoing catheter ablation, we prospectively studied the course and contact of the esophagus in relation to LA and the topographic proximity to ablation lines encircling the right-sided and left-sided pulmonary veins (PV) as well as to the posterior line connecting the encircling lines using the electromagnetic mapping system for reconstruction of LA and for tagging of the esophagus. This new technique of anatomic tagging of the esophagus was validated against the CT scan as a standard imaging procedure. The esophageal course was highly variable, extending from courses in direct vicinity to the left- or right-sided PV as well as in the midportion of the posterior LA. In order to avoid energy application in direct proximity to the esophagus, adjustments of the left and right PV encircling lines were necessary in 14/30 pts (47%) and 3/30 (10%). In 30 pts (100%), the mid- to inferior areas of the posterior LA revealed contact with the esophagus. Therefore, posterior and inferior linear ablation lines were abandoned and shifted to superior in 29 pts (97%). CONCLUSIONS Anatomic tagging of esophagus revealed a highly variable proximity to different areas of the posterior LA suggesting individual adjustment of encircling and linear ablation lines in AF ablation procedures to avoid the life threatening complication of esophagus perforation.
Resumo:
OBJECTIVES The aim of the study was to determine the incidence of atrial flutter and other arrhythmia recurrences (other than atrial fibrillation [AF]) during long-term follow-up after left atrial substrate modification by percutaneous radiofrequency (RF) ablation of AF. BACKGROUND RF ablation is an effective treatment for patients with AF. However, late recurrent arrhythmias may complicate the patient's course. METHODS One hundred fifty consecutive patients with paroxysmal or persistent AF were included in this prospective study. The incidence of arrhythmia recurrences after AF ablation was analyzed during long-term follow-up using repetitive 7-day ECG recording. RESULTS In 28 of 150 patients (18.7%), stable regular arrhythmias other than AF were detected during follow-up. Left atrial flutter observed in 10 patients (6.7%) was treated by recompletion of the ablation lines in all 10 patients. Left atrial flutter was associated with recurrence of AF in all 10 patients. Nine of 10 patients (90%) were free from atrial flutter and 6 of 10 patients were free from AF after the second intervention. Typical right atrial flutter occurred in 10 patients (6.7%) and was treated successfully by percutaneous RF ablation without recurrence in all patients. Additionally, atrial flutter was documented during follow-up in 7 patients (4.7%); however, invasive electrophysiologic evaluation was not performed due to various reasons. CONCLUSIONS Left atrial flutter is a relevant complication after RF catheter ablation of AF and was always associated with AF recurrence in our study population. Prevention of left atrial flutter can be achieved by induction of ablation lines as continuous and transmural as possible. However, left atrial flutter that does occur late after ablation is amenable to interventional treatment with good prospects of success.
Resumo:
Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.
Resumo:
Background Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes. Objective We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation. Methods A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients were randomized to either cardioversion (PVI-alone group; n = 33) or additional CFAE ablation (PVI+CFAE group; n = 35) and followed up every 1–3 months and serial Holter recordings were also obtained. The primary end point was the recurrence of AF/atrial tachycardia (AT) after a blanking period of 3 months. Results Procedure duration (127 ± 6 minutes vs 174 ± 10 minutes), radiofrequency application time (44 ± 3 minutes vs 74 ± 5 minutes), and fluoroscopy time (26 ± 2 minutes vs 41 ± 3 minutes) were longer in the PVI+CFAE group (all P < .001). In 30 of 35 patients (86%) in the PVI+CFAE group, ablation terminated AF. There was no significant group difference with respect to freedom from AF/AT (22 of 33 [67%] vs 22 of 35 [63%]; P = .66). Subsequently, 10 of 11 patients in the PVI-alone group (91%) and 11 of 13 patients in PVI+CFAE group (85%) underwent repeat ablation (P = 1.00). Overall, 29 of 33 [88%] vs 30 of 35 [86%] patients (P = 1.00) were free from AF/AT after 1.4 ± 0.1 vs 1.4 ± 0.2 (P = .87) procedures. Conclusion Patients with sustained AF after PVI in a PAF cohort are rare. Regarding AF/AT recurrence, these patients did not benefit from further CFAE ablation compared to PVI alone, but are exposed to longer procedure duration, fluoroscopy time, and radiofrequency application time.
Resumo:
BACKGROUND -This study aimed to determine five-year efficacy of catheter ablation for persistent atrial fibrillation (PsAF) using AF termination as a procedural endpoint. METHODS AND RESULTS -150 patients (57±10 years) underwent PsAF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided and linear ablation) with the desired procedural endpoint being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia (AT). AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3±3.9%, 28.0±3.7%, and 16.8±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7±2.5%, 79.8±3.4%, and 62.9±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (IQR 43-73) months following the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs (AADs). Another 14 (9.3%) patients maintained sinus rhythm after re-initiation of AADs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (HR 3.831; 95%CI: 2.070-7.143; p<0.001), left atrial diameter ≥50mm (HR 2.083; 95%CI: 1.078-4.016; p=0.03), continuous AF duration ≥18 months (HR 1.984; 95%CI: 1.024-3.846; p<0.04) and structural heart disease (HR 1.874; 95% CI: 1.037-3.388; p=0.04) predicted arrhythmia recurrence. CONCLUSIONS -In patients with PsAF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow up period.Procedural AF non-termination and specific baseline factors predict long-term outcome after ablation.
Resumo:
Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.
Resumo:
BACKGROUND In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. METHODS AND RESULTS A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007-2009). A total of 493 patients were included (Holter ECGs ≥ every 6 months). Mean follow-up was 59 ± 16 months with 2.1 ± 1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug-free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093-1.497; P = 0.002), number of procedures (HR, 1.154; 95% CI, 1.051-1.267; P = 0.003), female sex (HR, 1.263; 95% CI, 1.027-1.553; P = 0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003-1.524; P = 0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P = 0.003; HR, 1.71; 95% CI, 1.20-2.43). CONCLUSIONS Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.
Resumo:
OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).
Resumo:
UNLABELLED Obesity is a well-recognized risk factor for atrial fibrillation (AF), yet adiposity measures other than body mass index (BMI) have had limited assessment in relation to AF risk. We examined the associations of adiposity measures with AF in a biracial cohort of older adults. Given established racial differences in obesity and AF, we assessed for differences by black and white race in relating adiposity and AF. METHODS We analyzed data from 2,717 participants of the Health, Aging, and Body Composition Study. Adiposity measures were BMI, abdominal circumference, subcutaneous and visceral fat area, and total and percent fat mass. We determined the associations between the adiposity measures and 10-year incidence of AF using Cox proportional hazards models and assessed for their racial differences in these estimates. RESULTS In multivariable-adjusted models, 1-SD increases in BMI, abdominal circumference, and total fat mass were associated with a 13% to 16% increased AF risk (hazard ratio [HR] 1.14, 95% CI 1.02-1.28; HR 1.16, 95% CI 1.04-1.28; and HR 1.13, 95% CI 1.002-1.27). Subcutaneous and visceral fat areas were not significantly associated with incident AF. We did not identify racial differences in the associations between the adiposity measures and AF. CONCLUSION Body mass index, abdominal circumference, and total fat mass are associated with risk of AF for 10years among white and black older adults. Obesity is one of a limited number of modifiable risk factors for AF; future studies are essential to evaluate how obesity reduction can modify the incidence of AF.
Resumo:
OBJECTIVE To evaluate horses with atrial fibrillation for hypercoagulability; plasma D-dimer concentrations, as a marker of a procoagulant state; and a relationship between coagulation profile results and duration of atrial fibrillation or presence of structural heart disease. DESIGN Case-control study. ANIMALS Plasma samples from 42 horses (25 with atrial fibrillation and 17 without cardiovascular or systemic disease [control group]). PROCEDURES Results of hematologic tests (ie, plasma fibrinogen and D-dimer concentrations, prothrombin and activated partial thromboplastin times, and antithrombin activity) in horses were recorded to assess coagulation and fibrinolysis. Historical and clinical variables, as associated with a hypercoagulable state in other species, were also recorded. RESULTS Horses with atrial fibrillation and control horses lacked clinical signs of hypercoagulation or thromboembolism. Compared with control horses, horses with atrial fibrillation had significantly lower antithrombin activity. No significant differences in plasma fibrinogen and D-dimer concentrations and prothrombin and activated partial thromboplastin times existed between horse groups. In horses with atrial fibrillation versus control horses, a significantly larger proportion had an abnormal plasma D-dimer concentration (10/25 vs 2/17), test results indicative of subclinical activated coagulation (18/25 vs 6/17), or abnormal coagulation test results (25/121 vs 7/85), respectively. CONCLUSIONS AND CLINICAL RELEVANCE Horses with atrial fibrillation did not have clinical evidence of a hypercoagulable state, but a higher proportion of horses with atrial fibrillation, compared with control horses, did have subclinical activated coagulation on the basis of standard coagulation test results.