954 resultados para frequency stabilization, ultra trace analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"U.S. Atomic Energy Commission Contract AT(29-1)-1106."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectional observational study in 84 term and near-term healthy neonates less than 12 h postpartum. Whole body and cerebral MFBIA measurements were performed at the bedside in the post-natal ward. Gestational age, post-natal age, gender, birthweight, head circumference and foot length measures were recorded. Reference values for impedance at the characteristic frequency (Z(C)) and resistance at zero frequency (R-0) are reported for whole body and cerebral impedance. Significant correlations (p < 0.05) were observed between whole body impedance and birthweight, footlength and head circumference. Females had a significantly higher whole body R0 than males. Cerebral impedance did not correlate significantly with any of the demographic measures and therewere no gender differences observed for cerebral impedance. The reference range for whole body multi-frequency bio-impedance values in term and near-term infants within the first 12 h postpartum can be calculated from the footlength (FL) using the following equations: Z(C) = (942.9 - 4.818* FL) +/- 124.6 Omega; R-0 = (1042 - 4.520(*)FL) +/- 135.5 Omega. For cerebral impedance the reference range is 29.5-48.7 Omega for Z(C) and 33.7-58.0 Omega for R-0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hexavalent chromium is a heavy metal present in various industrial effluents, and depending on its concentration may cause irreparable damage to the environment and to humans. Facing this surrounding context, this study aimed on the application of electrochemical methods to determine and remove the hexavalent chromium (Cr6+) in simulated wastewater. To determine was applied to cathodic stripping voltammetry (CSV) using ultra trace graphite electrodes ultra trace (work), Ag/AgCl (reference) and platinum (counter electrode), the samples were complexed with 1,5- diphenylcarbazide and then subjected to analysis. The removal of Cr6+ was applied electrocoagulation process (EC) using Fe and Al electrodes. The variables that constituted the factorial design 24, applied to optimizing the EC process, were: current density (5 and 10 mA.cm-2), temperature (25 and 60 ºC), concentration (50 and 100 ppm) and agitation rate (400 and 600 RPM). Through the preliminary test it was possible the adequacy of applying the CSV for determining of Cr6+, removed during the EC process. The Fe and Al electrodes as anodes sacrifice showed satisfactory results in the EC process, however Fe favored complete removal in 30 min, whereas with Al occurred at 240 min. In the application of factorial design 24 and analysis of Response Surface Methodology was possible to optimize the EC process for removal of Cr6+ in H2SO4 solution (0.5 mol.L-1), in which the temperature, with positive effect, was the variable that presented higher statistical significance compared with other variables and interactions, while in optimizing the EC process for removal of Cr6+ in NaCl solution (0.1 mol.L-1) the current density, with positive effect, and concentration, with a negative effect were the variables that had greater statistical significance with greater statistical significance compared with other variables and interactions. The utilization of electrolytes supports NaCl and Na2SO4 showed no significant differences, however NaCl resulted in rapid improvement in Cr6+ removal kinetics and increasing the NaCl concentration provided an increase in conductivity of the solution, resulting in lower energy consumption. The wear of the electrodes evaluated in all the process of EC showed that the Al in H2SO4 solution (0.5 mol.L-1), undergoes during the process of anodization CE, then the experimental mass loss is less than the theoretical mass loss, however, the Fe in the same medium showed a loss of mass greater experimental estimated theoretically. This fact is due to a spontaneous reaction of Fe with H2SO4, and when the reaction medium was the NaCl and Na2SO4 loss experimental mass approached the theoretical mass loss. Furthermore, it was observed the energy consumption of all processes involved in this study had a low operating cost, thus enabling the application of the EC process for treating industrial effluents. The results were satisfactory, it was achieved complete removal of Cr6+ in all processes used in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A investigação na área da saúde e a utilização dos seus resultados tem funcionado como base para a melhoria da qualidade de cuidados, exigindo dos profissionais de saúde conhecimentos na área específica onde desempenham funções, conhecimentos em metodologia de investigação que incluam as técnicas de observação, técnicas de recolha e análise de dados, para mais facilmente serem leitores capacitados dos resultados da investigação. Os profissionais de saúde são observadores privilegiados das respostas humanas à saúde e à doença, podendo contribuir para o desenvolvimento e bem-estar dos indivíduos muitas vezes em situações de grande vulnerabilidade. Em saúde infantil e pediatria o enfoque está nos cuidados centrados na família privilegiando-se o desenvolvimento harmonioso da criança e jovem, valorizando os resultados mensuráveis em saúde que permitam determinar a eficácia das intervenções e a qualidade de saúde e de vida. No contexto pediátrico realçamos as práticas baseadas na evidência, a importância atribuída à pesquisa e à aplicação dos resultados da investigação nas práticas clínicas, assim como o desenvolvimento de instrumentos de mensuração padronizados, nomeadamente as escalas de avaliação, de ampla utilização clínica, que facilitam a apreciação e avaliação do desenvolvimento e da saúde das crianças e jovens e resultem em ganhos em saúde. A observação de forma sistematizada das populações neonatais e pediátricas com escalas de avaliação tem vindo a aumentar, o que tem permitido um maior equilíbrio na avaliação das crianças e também uma observação baseada na teoria e nos resultados da investigação. Alguns destes aspetos serviram de base ao desenvolvimento deste trabalho que pretende dar resposta a 3 objetivos fundamentais. Para dar resposta ao primeiro objetivo, “Identificar na literatura científica, os testes estatísticos mais frequentemente utilizados pelos investigadores da área da saúde infantil e pediatria quando usam escalas de avaliação” foi feita uma revisão sistemática da literatura, que tinha como objetivo analisar artigos científicos cujos instrumentos de recolha de dados fossem escalas de avaliação, na área da saúde da criança e jovem, desenvolvidas com variáveis ordinais, e identificar os testes estatísticos aplicados com estas variáveis. A análise exploratória dos artigos permitiu-nos verificar que os investigadores utilizam diferentes instrumentos com diferentes formatos de medida ordinal (com 3, 4, 5, 7, 10 pontos) e tanto aplicam testes paramétricos como não paramétricos, ou os dois em simultâneo, com este tipo de variáveis, seja qual for a dimensão da amostra. A descrição da metodologia nem sempre explicita se são cumpridas as assunções dos testes. Os artigos consultados nem sempre fazem referência à distribuição de frequência das variáveis (simetria/assimetria) nem à magnitude das correlações entre os itens. A leitura desta bibliografia serviu de suporte à elaboração de dois artigos, um de revisão sistemática da literatura e outro de reflexão teórica. Apesar de terem sido encontradas algumas respostas às dúvidas com que os investigadores e os profissionais, que trabalham com estes instrumentos, se deparam, verifica-se a necessidade de desenvolver estudos de simulação que confirmem algumas situações reais e alguma teoria já existente, e trabalhem outros aspetos nos quais se possam enquadrar os cenários reais de forma a facilitar a tomada de decisão dos investigadores e clínicos que utilizam escalas de avaliação. Para dar resposta ao segundo objetivo “Comparar a performance, em termos de potência e probabilidade de erro de tipo I, das 4 estatísticas da MANOVA paramétrica com 2 estatísticas da MANOVA não paramétrica quando se utilizam variáveis ordinais correlacionadas, geradas aleatoriamente”, desenvolvemos um estudo de simulação, através do Método de Monte Carlo, efetuado no Software R. O delineamento do estudo de simulação incluiu um vetor com 3 variáveis dependentes, uma variável independente (fator com três grupos), escalas de avaliação com um formato de medida com 3, 4, 5, e 7 pontos, diferentes probabilidades marginais (p1 para distribuição simétrica, p2 para distribuição assimétrica positiva, p3 para distribuição assimétrica negativa e p4 para distribuição uniforme) em cada um dos três grupos, correlações de baixa, média e elevada magnitude (r=0.10, r=0.40, r=0.70, respetivamente), e seis dimensões de amostras (n=30, 60, 90, 120, 240, 300). A análise dos resultados permitiu dizer que a maior raiz de Roy foi a estatística que apresentou estimativas de probabilidade de erro de tipo I e de potência de teste mais elevadas. A potência dos testes apresenta comportamentos diferentes, dependendo da distribuição de frequência da resposta aos itens, da magnitude das correlações entre itens, da dimensão da amostra e do formato de medida da escala. Tendo por base a distribuição de frequência, considerámos três situações distintas: a primeira (com probabilidades marginais p1,p1,p4 e p4,p4,p1) em que as estimativas da potência eram muito baixas, nos diferentes cenários; a segunda situação (com probabilidades marginais p2,p3,p4; p1,p2,p3 e p2,p2,p3) em que a magnitude das potências é elevada, nas amostras com dimensão superior ou igual a 60 observações e nas escalas com 3, 4,5 pontos e potências de magnitude menos elevada nas escalas com 7 pontos, mas com a mesma ma magnitude nas amostras com dimensão igual a 120 observações, seja qual for o cenário; a terceira situação (com probabilidades marginais p1,p1,p2; p1,p2,p4; p2,p2,p1; p4,p4,p2 e p2,p2,p4) em que quanto maiores, a intensidade das correlações entre itens e o número de pontos da escala, e menor a dimensão das amostras, menor a potência dos testes, sendo o lambda de Wilks aplicado às ordens mais potente do que todas as outra s estatísticas da MANOVA, com valores imediatamente a seguir à maior raiz de Roy. No entanto, a magnitude das potências dos testes paramétricos e não paramétricos assemelha-se nas amostras com dimensão superior a 90 observações (com correlações de baixa e média magnitude), entre as variáveis dependentes nas escalas com 3, 4 e 5 pontos; e superiores a 240 observações, para correlações de baixa intensidade, nas escalas com 7 pontos. No estudo de simulação e tendo por base a distribuição de frequência, concluímos que na primeira situação de simulação e para os diferentes cenários, as potências são de baixa magnitude devido ao facto de a MANOVA não detetar diferenças entre grupos pela sua similaridade. Na segunda situação de simulação e para os diferentes cenários, a magnitude das potências é elevada em todos os cenários cuja dimensão da amostra seja superior a 60 observações, pelo que é possível aplicar testes paramétricos. Na terceira situação de simulação, e para os diferentes cenários quanto menor a dimensão da amostra e mais elevada a intensidade das correlações e o número de pontos da escala, menor a potência dos testes, sendo a magnitude das potências mais elevadas no teste de Wilks aplicado às ordens, seguido do traço de Pillai aplicado às ordens. No entanto, a magnitude das potências dos testes paramétricos e não paramétricos assemelha-se nas amostras com maior dimensão e correlações de baixa e média magnitude. Para dar resposta ao terceiro objetivo “Enquadrar os resultados da aplicação da MANOVA paramétrica e da MANOVA não paramétrica a dados reais provenientes de escalas de avaliação com um formato de medida com 3, 4, 5 e 7 pontos, nos resultados do estudo de simulação estatística” utilizaram-se dados reais que emergiram da observação de recém-nascidos com a escala de avaliação das competências para a alimentação oral, Early Feeding Skills (EFS), o risco de lesões da pele, com a Neonatal Skin Risk Assessment Scale (NSRAS), e a avaliação da independência funcional em crianças e jovens com espinha bífida, com a Functional Independence Measure (FIM). Para fazer a análise destas escalas foram realizadas 4 aplicações práticas que se enquadrassem nos cenários do estudo de simulação. A idade, o peso, e o nível de lesão medular foram as variáveis independentes escolhidas para selecionar os grupos, sendo os recém-nascidos agrupados por “classes de idade gestacional” e por “classes de peso” as crianças e jovens com espinha bífida por “classes etárias” e “níveis de lesão medular”. Verificou-se um bom enquadramento dos resultados com dados reais no estudo de simulação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the problem of appropriate load sharing in an autonomous microgrid. High gain angle droop control ensures proper load sharing, especially under weak system conditions. However it has a negative impact on overall stability. Frequency domain modeling, eigenvalue analysis and time domain simulations are used to demonstrate this conflict. A supplementary loop is proposed around a conventional droop control of each DG converter to stabilize the system while using high angle droop gains. Control loops are based on local power measurement and modulation of the d-axis voltage reference of each converter. Coordinated design of supplementary control loops for each DG is formulated as a parameter optimization problem and solved using an evolutionary technique. The sup-plementary droop control loop is shown to stabilize the system for a range of operating conditions while ensuring satisfactory load sharing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the identification of common single locus point mutations as risk factors for thrombophilia, many DNA testing methodologies have been described for detecting these variations. Traditionally, functional or immunological testing methods have been used to investigate quantitative anticoagulant deficiencies. However, with the emergence of the genetic variations, factor V Leiden, prothrombin 20210 and, to a lesser extent, the methylene tetrahydrofolate reductase (MTHFR677) and factor V HR2 haplotype, traditional testing methodologies have proved to be less useful and instead DNA technology is more commonly employed in diagnostics. This review considers many of the DNA techniques that have proved to be useful in the detection of common genetic variants that predispose to thrombophilia. Techniques involving gel analysis are used to detect the presence or absence of restriction sites, electrophoretic mobility shifts, as in single strand conformation polymorphism or denaturing gradient gel electrophoresis, and product formation in allele-specific amplification. Such techniques may be sensitive, but are unwielding and often need to be validated objectively. In order to overcome some of the limitations of gel analysis, especially when dealing with larger sample numbers, many alternative detection formats, such as closed tube systems, microplates and microarrays (minisequencing, real-time polymerase chain reaction, and oligonucleotide ligation assays) have been developed. In addition, many of the emerging technologies take advantage of colourimetric or fluorescence detection (including energy transfer) that allows qualitative and quantitative interpretation of results. With the large variety of DNA technologies available, the choice of methodology will depend on several factors including cost and the need for speed, simplicity and robustness. © 2000 Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims at developing a planetary rover capable of acting as an assistant astrobiologist: making a preliminary analysis of the collected visual images that will help to make better use of the scientists time by pointing out the most interesting pieces of data. This paper focuses on the problem of detecting and recognising particular types of stromatolites. Inspired by the processes actual astrobiologists go through in the field when identifying stromatolites, the processes we investigate focus on recognising characteristics associated with biogenicity. The extraction of these characteristics is based on the analysis of geometrical structure enhanced by passing the images of stromatolites into an edge-detection filter and its Fourier Transform, revealing typical spatial frequency patterns. The proposed analysis is performed on both simulated images of stromatolite structures and images of real stromatolites taken in the field by astrobiologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The provision of a written comment on traumatic abnormalities of the musculoskeletal system detected by radiographers can assist referrers and may improve patient management, but the practice has not been widely adopted outside the United Kingdom. The purpose of this study was to investigate Australian radiographers’ perceptions of their readiness for practice in a radiographer commenting system and their educational preferences in relation to two different delivery formats of image interpretation education, intensive and non-intensive. Methods A cross-sectional web-based questionnaire was implemented between August and September 2012. Participants included radiographers with experience working in emergency settings at four Australian metropolitan hospitals. Conventional descriptive statistics, frequency histograms, and thematic analysis were undertaken. A Wilcoxon signed-rank test examined whether a difference in preference ratings between intensive and non-intensive education delivery was evident. Results The questionnaire was completed by 73 radiographers (68% response rate). Radiographers reported higher confidence and self-perceived accuracy to detect traumatic abnormalities than to describe traumatic abnormalities of the musculoskeletal system. Radiographers frequently reported high desirability ratings for both the intensive and the non-intensive education delivery, no difference in desirability ratings for these two formats was evident (z = 1.66,P = 0.11). Conclusions Some Australian radiographers perceive they are not ready to practise in a frontline radiographer commenting system. Overall, radiographers indicated mixed preferences for image interpretation education delivered via intensive and non-intensive formats. Further research, preferably randomised trials, investigating the effectiveness of intensive and non-intensive education formats of image interpretation education for radiographers is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hereditary haemochromatosis (HH) is the most common lethal monogenic human disease, affecting roughly 1 in 300 white northern Europeans. Homozygosity for the C282Y polymorphism within the HFE gene causes more than 80% of cases, with compound heterozygosity of the C282Y and H63D polymorphism also increasing susceptibility to disease. The aim of this study was to determine the frequency of the C282Y and H63D polymorphisms in the disease, and to assess the risk of HH in heterozygotes for the C282Y polymorphism. 128 patients were recruited because of either radiographic chondrocalcinosis (at least bicompartmental knee disease or joints other than the knee involved) or CPPD pseudogout. Genotyping of the HFE C282Y and H63D mutations was performed using PCR/SSP and genotypes for the C282Y polymorphism confirmed by PCR/RFLP. Historical white European control data were used for comparison. Two previously undiagnosed C282Y homozygotes (1.6%), and 16 C282Y heterozygotes (12.5%), including four (3.1%) C282Y/ H63D compound heterozygotes were identified. This represents a significant overrepresentation of C282Y homozygotes (relative risk 3.4, p-0.037), but the number of heterozygotes was not significantly increased. At a cost per test of £1 for each subject, screening all patients with chondrocalcinosis using the above ascertainment criteria costs only £64 for each case of haemochromatosis identified, clearly a highly cost effective test given the early mortality associated with untreated haemochromatosis. Routine screening for haemochromatosis in patients with appreciable chondrocatcinosis is recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiometric determination methods, such as alpha spectrometry require long counting times when low activities are to be determined. Mass spectrometric techniques as Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Thermal Ionisation Mass Spectrometry (TIMS) and Accelerator Mass Spectrometry (AMS) have shown several advantages compared to traditional methods when measuring long-lived radionuclides. Mass spectrometric methods for determination of very low concentrations of elemental isotopes, and thereby isotopic ratios, have been developed using a variety of ion sources. Although primarily applied to the determination of the lighter stable element isotopes and radioactive isotopes in geological studies, the techniques can equally well be applied to the measurement of activity concentrations of long-lived low-level radionuclides in various samples using “isotope dilution” methods such as those applied in inductively coupled plasma mass spectrometry (ICP-MS). Due to the low specific activity of long-lived radionuclides, many of these are more conveniently detected using mass spectrometric techniques. Mass spectrometry also enables the individual determination of Pu-239 and Pu-240, which cannot be obtained by alpha spectrometry. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) are rapidly growing techniques for the ultra-trace analytical determination of stable and long-lived isotopes and have a wide potential within environmental science, including ecosystem tracers and radio ecological studies. Such instrumentation, of course needs good radiochemical separation, to give best performance. The objectives of the project is to identify current needs and problems within low-level determination of long-lived radioisotopes by ICP-MS, to perform intercalibration and development and improvement of ICP-MS methods for the measurement of radionuclides and isotope ratios and to develop new methods based on modified separation chemistry applied to new auxiliary equipment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An understanding of application I/O access patterns is useful in several situations. First, gaining insight into what applications are doing with their data at a semantic level helps in designing efficient storage systems. Second, it helps create benchmarks that mimic realistic application behavior closely. Third, it enables autonomic systems as the information obtained can be used to adapt the system in a closed loop.All these use cases require the ability to extract the application-level semantics of I/O operations. Methods such as modifying application code to associate I/O operations with semantic tags are intrusive. It is well known that network file system traces are an important source of information that can be obtained non-intrusively and analyzed either online or offline. These traces are a sequence of primitive file system operations and their parameters. Simple counting, statistical analysis or deterministic search techniques are inadequate for discovering application-level semantics in the general case, because of the inherent variation and noise in realistic traces.In this paper, we describe a trace analysis methodology based on Profile Hidden Markov Models. We show that the methodology has powerful discriminatory capabilities that enable it to recognize applications based on the patterns in the traces, and to mark out regions in a long trace that encapsulate sets of primitive operations that represent higher-level application actions. It is robust enough that it can work around discrepancies between training and target traces such as in length and interleaving with other operations. We demonstrate the feasibility of recognizing patterns based on a small sampling of the trace, enabling faster trace analysis. Preliminary experiments show that the method is capable of learning accurate profile models on live traces in an online setting. We present a detailed evaluation of this methodology in a UNIX environment using NFS traces of selected commonly used applications such as compilations as well as on industrial strength benchmarks such as TPC-C and Postmark, and discuss its capabilities and limitations in the context of the use cases mentioned above.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several replacement policies for web caches have been proposed and studied extensively in the literature. Different replacement policies perform better in terms of (i) the number of objects found in the cache (cache hit), (ii) the network traffic avoided by fetching the referenced object from the cache, or (iii) the savings in response time. In this paper, we propose a simple and efficient replacement policy (hereafter known as SE) which improves all three performance measures. Trace-driven simulations were done to evaluate the performance of SE. We compare SE with two widely used and efficient replacement policies, namely Least Recently Used (LRU) and Least Unified Value (LUV) algorithms. Our results show that SE performs at least as well as, if not better than, both these replacement policies. Unlike various other replacement policies proposed in literature, our SE policy does not require parameter tuning or a-priori trace analysis and has an efficient and simple implementation that can be incorporated in any existing proxy server or web server with ease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article deals with the axial wave propagation properties of a coupled nanorod system with consideration of small scale effects. The nonlocal elasticity theory has been incorporated into classical rod/bar model to capture unique features of the coupled nanorods under the umbrella of continuum mechanics theory. Nonlocal rod model is developed for coupled nanorods. The strong effect of the nonlocal scale has been obtained which leads to substantially different wave behavior of nanorods from those of macroscopic rods. Explicit expressions are derived for wavenumber, cut-off frequency and escape frequency of nanorods. The analysis shows that the wave characteristics of nanorods are highly over estimated by the classical rod model, which ignores the effect of small-length scale. The studies also shows that the nonlocal scale parameter introduces certain band gap region in axial or longitudinal wave mode, where no wave propagation occurs. This is manifested in the spectrum cures as the region, where the wavenumber tends to infinite or wave speed tends to zero. The effect of the coupled spring stiffness is also capture in the present analysis. It has been also shown that the cut-off frequency increases as the stiffness of the coupled spring increases and also the coupled spring stiffness has no effect on escape frequency of the axial wave mode in the nanorod. This cut-off frequency is also independent of the nonlocal small scale parameter. The present study may bring in helpful insights while investigating multiple-nanorod-system-models for future nano-optomechanical systems applications. The results can also provide useful guidance for the study and design of the next generation of nanodevices that make use of the wave propagation properties of coupled single-walled carbon nanotubes or coupled nanorods. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Interaction of non-structural protein 5A (NS5A) of Hepatitis C virus (HCV) with human kinases namely, casein kinase 1 alpha (ck1 alpha) and protein kinase R (PKR) have different functional implications such as regulation of viral replication and evasion of interferon induced immune response respectively. Understanding the structural and molecular basis of interactions of the viral protein with two different human kinases can be useful in developing strategies for treatment against HCV. Results: Serine 232 of NS5A is known to be phosphorylated by human ck1 alpha. A structural model of NS5A peptide containing phosphoacceptor residue Serine 232 bound to ck1 alpha has been generated using the known 3-D structures of kinase-peptide complexes. The substrate interacting residues in ck1 alpha has been identified from the model and these are found to be conserved well in the ck1 family. ck1 alpha - substrate peptide complex has also been used to understand the structural basis of association between ck1 alpha and its other viral stress induced substrate, tumour suppressor p53 transactivation domain which has a crystal structure available. Interaction of NS5A with another human kinase PKR is primarily genotype specific. NS5A from genotype 1b has been shown to interact and inhibit PKR whereas NS5A from genotype 2a/3a are unable to bind and inhibit PKR efficiently. This is one of the main reasons for the varied response to interferon therapy in HCV patients across different genotypes. Using PKR crystal structure, sequence alignment and evolutionary trace analysis some of the critical residues responsible for the interaction of NS5A 1b with PKR have been identified. Conclusions: The substrate interacting residues in ck1 alpha have been identified using the structural model of kinase substrate peptide. The PKR interacting NS5A 1b residues have also been predicted using PKR crystal structure, NS5A sequence analysis along with known experimental results. Functional significance and nature of interaction of interferon sensitivity determining region and variable region 3 of NS5A in different genotypes with PKR which was experimentally shown are also supported by the findings of evolutionary trace analysis. Designing inhibitors to prevent this interaction could enable the HCV genotype 1 infected patients respond well to interferon therapy.