938 resultados para frames tecnológicos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the experimental results of loading tests on two 18m span tapered member portal frames designed to BS 5950. Deflection test results for vertical, lateral and combined loading cases are compared with the predictions given by elastic analysis to BS 5950 and shown to be favourable. The predicted ultimate capacities and modes of failure, which were by lateral-torsional buckling of the columns, were also found to agree with the experimental behaviour. It was found that the method of modelling the tapered members as a series of prismatic elements gave good comparison with test results.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the findings of a project part sponsored by an ICE Research and Development grant on portal frames in fire. The research reported here has also lead to a sucessful research grant from the IStructE. The paper describes a non-linear elasto plastic dynamic finite element model that captures the collapse of a portal frame in fire. It demonstrates that current guidance on the column base stiffness and strength, to prevent collapse, may in some cases be unconservative.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel portal frames are a popular form of construction for low-rise commercial, light industrial and agricultural buildings with spans of up to 20 m. In this article, a real-coded genetic algorithm is described that is used to minimize the cost of the main frame of such buildings. The key decision variables considered in this proposed algorithm consist of both the spacing and pitch of the frame as continuous variables, as well as the discrete section sizes.A routine taking the structural analysis and frame design for cold-formed steel sections is embedded into a genetic algorithm. The results show that the real-coded genetic algorithm handles effectively the mixture of design variables, with high robustness and consistency in achieving the optimum solution. All wind load combinations according to Australian code are considered in this research. Results for frames with knee braces are also included, for which the optimization achieved even larger savings in cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The susceptibility of WiFi networks to Rogue Access Point attacks derives from the lack of identity for 802.11 devices. The most common means of detecting these attacks in current research is through tracking the credentials or the location of unauthorised and possibly malicious APs. In this paper, the authors outline a method of distinguishing WiFi Access Points using 802.11 MAC layer management frame traffic profiles. This system does not require location estimation or credential tracking techniques as used in current research techniques, which are known to be inaccurate. These characteristic management traffic profiles are shown to be unique for each device, tantamount to a MAC identity. The application of this technique to solving Rogue AP attacks under the constraints of an open access, public WiFi environment is discussed with the conclusion that the identity is practically very difficult to forge

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of hot-rolled steel portal frames can be sensitive to serviceability deflection limits. In such cases, in order to reduce frame deflections, practitioners increase the size of the eaves haunch and / or the sizes of the steel sections used for the column and rafter members of the frame. This paper investigates the effect of such deflection limits using a real-coded niching genetic algorithm (RC-NGA) that optimizes frame weight, taking into account both ultimate as well as serviceability limit states. The results show that the proposed GA is efficient and reliable. Two different sets of serviceability deflection limits are then considered: deflection limits recommended by the Steel Construction Institute (SCI), which is based on control of differential deflections, and other deflection limits based on suggestions by industry. Parametric studies are carried out on frames with spans ranging between 15 m to 50 m and column heights between 5 m to 10 m. It is demonstrated that for a 50 m span frame, use of the SCI recommended deflection limits can lead to frame weights that are around twice as heavy as compared to designs without these limits.