880 resultados para foto-Fenton


Relevância:

20.00% 20.00%

Publicador:

Resumo:

COD is an important parameter to estimate the concentration of organic contaminants. The closed system technique with the use of K2Cr2O7 is the most important one, however, it has the inconvenience to suffer positive chemical interferences from inorganic compounds such as Fe2+ and H2O2 (not enough reported in the literature). This paper considers a statistical-experimental set capable to validate a empirical mathematical model generated from a 23 experimental design, in the presence of Fe2+ and H2O2. The t test shows that mathematical model has 99,99999% confidence degree and the experimental validation test indicates absolute mean error of 4,70%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of the electrochemical degradation of the ranitidine was developed using an electrochemical reactor with a gas diffusion electrode (GDE) as cathode. The electrolysis experiments was performed at constant current (1 < A < 10) and flow rate of 200 L h-1. The process of drug degradation, chemical/electrochemical and electro-Fenton ways, using electrochemical reactor showed best efficiency at current values of > 4 A. The process reached a production of 630 mg L-1 of the H2O2 at 7 A. The ranitidine concentrations was reduced in 99.9% (HPLC) and chemical oxygen demand (COD) was reduced in 86.7% by electro-Fenton.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a degradation study of the anti-inflammatory sodium diclofenac in aqueous medium using an electro-chemical flow reactor with a gas diffusion electrode as cathode. Two degradation processes were compared: by H2O2 electro-generated and H2O2 electro-generated/Fe(II). Concentration of sodium diclofenac was determined during the experiments by HPLC. The changes in chemical oxigen demand (COD) were also evaluated. Under the specific reaction conditions, 350 mg L-1 of H2O2 was electro-generated and 99.2% of sodium diclofenac was degradated, with 27.4% COD reduction. At the same conditions, but using Fe(II), drug degradation was 99.4% and the COD reduction was 63.2%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of the Fenton's reagent process has been investigated for the remediation of a Brazilian soil contaminated by diesel. Laboratory experiments were conducted in batch experiments. Slurries, consisting of 10 g of diesel-contaminated soil and 30 mL of Fenton's Reagent (0.41 mol L-1 H(2)0(2) and 0.18 mol L-1 FeSO4). The experiments were monitored during 24, 48 and 72 h. The efficiency of the Fenton treatment was dependent on the time of contact between soil and Fenton's reagents and matrix characteristics, probably iron content. Data suggested that no iron addition is needed for the application of Fenton-like treatment for the remediation of diesel-contaminated iron rich soils after 72 h reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From the environmental point of view, the textile sector is outstanding for the generation of large amounts of biorecalcitrant effluents. In this paper the textile effluent biodegradability, both before and after its treatment with Fenton's Reagent, were compared by means of biologic tests. These tests showed that the Fenton treatment lowered the biodegradabilty of practically all tested effluents, except one specific effluent from a scouring bath of polyester fibers, which achieved a 93% COD removal. This removal was due to a significant phase separation (oil/water).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An alternative for landfill leachate treatment are advanced oxidation processes by Fenton's reagent (AOP/Fenton). In this context, the aim of this paper was to evaluate, in a bench scale, the treatability of leachate pós-AOP/Fenton characterizing the supernatant and the sludge generated separately. Observed in optimal conditions, high removal efficiency of COD (76.7%), real color (76.4%) and humic substances (50%). Organic compounds were detected in the sludge (2.465 mg COD L-1) and high concentration of iron (1.757 mg L-1) as was expected. Finally, the sludge generated showed low settling hindering their separation by sedimentation (SVI = 321 mL g-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zn-EDTA degradabilty by catechol-driven Fenton reaction was studied. Response surface methodology central composite design was employed to maximize this complex degradation. Theoretical speciation calculations were in good agreement with the experimental results. Fenton and Fenton type treatments are typically thought to be applicable only in the highly acidic range, representing a major operational constraint. Interestingly, at optimized concentrations, this CAT-driven Fenton reaction at pH 5.5 achieved 100% Zn-EDTA degradation; 60% COD and 17% TOC removals, using tiny amounts of CAT (50 µM), Fe(III) (445 µM) and H2O2 (20 mM) with no evident ferric sludge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flumequine degradation by electrochemical and photo-electrochemical processes was evaluated in this study. The antimicrobial activity of the solutions subjected to the electrochemical processes was monitored during the assays. The experiments were carried out using DSA® (dimensionally stable anode) electrode. The influence of current density was investigated for the 7.5 to 45 mA cm-2 range. The photo-electrochemical process was more efficient for degrading flumequine (85%) and reducing solution antimicrobial activity. For both processes, the residual antimicrobial activity decreased as flumequine degradation increased. The reaction intermediate m/z 244 (5-methyl-1-oxo-6,7-dihydro-1H,5H-pyrido[3,2,1-ij]quinoline-2-carboxylic acid) was identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the past few years, photoredox catalysis has become a powerful tool in the field of organic synthesis. Using this efficient method, it is possible to excite organic compounds from visible light and attain alternative mechanistic pathways for the formation of chemical bonds, a result which is not obtainable by classical methods. The rapid growth of work in the area of photoredox catalysis is due to its low cost, broad chemical utility protocols, and, especially, its relevancy from the green and sustainable chemistry viewpoints. Thus, this study proposes a brief theoretical discussion of and highlights recent advances in visible-light-induced photoredox catalysis through the analysis of catalytic cycles and intermediates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho foram estudados dois sistemas utilizando reações de Fenton para a remediação de um solo contaminado com p,p´ DDT. O primeiro envolveu a formação de uma lama com o solo contaminado, na qual foram adicionados os reagentes de Fenton. No segundo, não houve a formação de lama e os reagentes foram adicionados diretamente ao solo por meio de um "tubo injetor". Foram avaliados alguns parâmetros que podem influenciar a reação de Fenton, tais como minerais de ferro naturalmente presentes no solo e a irradiação solar. A principal espécie mineral de ferro encontrada no solo é a hematita (Fe2O3), que teve pouca influência na degradação do contaminante. Nos experimentos com lama sem adição de ferro solúvel a porcentagem de degradação do p,p´ DDT foi inferior a 25% após 24 horas de reação. Nos ensaios com lama na presença de ferro solúvel, a degradação do p,p´ DDT atingiu 70% em 32 horas, enquanto que nos experimentos sem lama, a porcentagem de degradação foi de 32% no mesmo intervalo de tempo. Em ambos os sistemas, a irradiação solar teve pouca influência na degradação do contaminante. Os resultados indicam que para um processo de remediação deste solo, há necessidade de adição de ferro solúvel e que o sistema em lama resulta em maior eficiência de degradação de p,p´ DDT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laboratories consume great amounts of hazardous chemicals substances and consequently generate wastewater containing them, for example formaldehyde. This substance is widely utilized to preserve biological samples generating many liters of this residue every year. The present work proposes the use of the photo-Fenton process to treat formaldehyde wastewater using sunlight irradiation. Some aspects were investigated such as the iron source, sample and hydrogen peroxide concentration and also the use of stirred systems. The use of ferrioxalate (0.5 mmol L-1) improved the efficiency of the process in relation to the use of iron nitrate, while at least 1.0 mol L-1 H2O2 is necessary to treat the sample of the 500 mg C L-1. Under these conditions, every formaldehyde detectable was degradeted and 89% of the dissolved organic carbon was removed in two hours of exposure to sunlight. These results are satisfaction considerate for São Paulo State Environmental Agency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrokinetic remediation coupled with Fenton oxidation, widely called as Electrokinetic Fenton process is a potential soil remediation technique used for low permeable soil. The applicability of the process has been proved with soil contaminated with a wide range of organic compounds from phenol to the most recalcitrant ones such as PAHs and POPs. This thesis summarizes the major findings observed during an Electrokinetic Fenton Process study conducted for the remediation of low permeable soil contaminated with HCB, a typical hydrophobic organic contaminant. Model low permeable soil, kaolin, was artificially contaminated with HCB and subjected to Electrokinetic Fenton treatments in a series of laboratory scale batch experiments. The use of cyclodextrins as an enhancement agent to mobilize the sorbed contaminant through the system was investigated. Major process hindrances such as the oxidant availability and treatment duration were also addressed. The HCB degradation along with other parameters like soil pH, redox and cumulative catholyte flow were analyzed and monitored. The results of the experiments strengthen the existing knowledge on electrokinetic Fenton process as a promising technology for the treatment of soil contaminated with hydrophobic organic compounds. It has been demonstrated that HCB sorbed to kaolin can be degraded by the use of high concentrations of hydrogen peroxide during such processes. The overall system performances were observed to be influenced by the point and mode of oxidant delivery. Furthermore, the study contributes to new knowledge in shortening the treatment duration by adopting an electrode polarity reversal during the process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Orientación en Química Analítica Ambiental) UANL, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con Orientación en Ingeniería Ambiental) UANL, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias con orientación en Ingeniería Ambiental) UANL, 2014.