956 resultados para flame retardation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical study of Brazilian patients with neurofibromatosis type 1 (NF1) was performed in a multidisciplinary Neurofibromatosis Program called CEPAN (Center of Research and Service in Neurofibromatosis). Among 55 patients (60% females, 40% males) who met the NIH criteria for the diagnosis of NF1, 98% had more than six café-au-lait patches, 94.5% had axillary freckling, 45% had inguinal freckling, and 87.5% had Lisch nodules. Cutaneous neurofibromas were observed in 96%, and 40% presented plexiform neurofibromas. A positive family history of NF1 was found in 60%, and mental retardation occurred in 35%. Some degree of scoliosis was noted in 49%, 51% had macrocephaly, 40% had short stature, 76% had learning difficulties, and 2% had optic gliomas. Unexpectedly high frequencies of plexiform neurofibromas, mental retardation, learning difficulties, and scoliosis were observed, probably reflecting the detailed clinical analysis methods adopted by the Neurofibromatosis Program. These same patients were screened for mutations in the GAP-related domain/GRD (exons 20-27a) by single-strand conformation polymorphism. Four different mutations (Q1189X, 3525-3526delAA, E1356G, c.4111-1G>A) and four polymorphisms (c.3315-27G>A, V1146I, V1317A, c.4514+11C>G) were identified. These data were recently published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivou-se, neste trabalho, estudar a conservação de pomelos (Citrus paradisi Macfad.) varieties 'Flame' e 'Henderson' revestidos com cera Sparcitrus e mantidos sob refrigeração (8º C ± 1º C e 95% ± 5% UR). Para cada variedade estudada, utilizou-se delineamento inteiramente casualizado, disposto em esquema fatorial 2 x 5, com 3 repetições, onde o primeiro fator correspondeu aos tratamentos com e sem a aplicação de cera (controle) e o segundo, ao tempo armazenamento (0, 10, 20, 30 e 40 dias). Cada parcela experimental foi composta por cinco frutos. Foram estudadas as seguintes variáveis: perda de massa, rendimento do suco, pH, sólidos solúveis (SS), acidez titulável (AT), SS/AT, açúcares redutores, açúcares não redutores, açúcares solúveis totais, vitamina C e aparência externa. A aplicação de cera é efetiva na preservação da aparência de pomelos 'Flame' e 'Henderson', não afetando sua qualidade interna.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Occurrence and the effects of butyltin compounds (BTs) have been studied for some years, mainly in countries of the Northern Hemisphere. Due to widespread use of tributyltin compounds (TBTs) and considering their deleterious effects, it is necessary to conduct studies on its occurrence, especially in the marine environment because of its excessive use in coatings of ship hulls to prevent fouling. Moreover, it was important to extend the evaluation to areas where there is no current information about their occurrence. The present work reports the occurrence of BTs in marine sediments of São Paulo state, Brazil. Commercial and leisure harbor sampling sites were selected because these areas are potentially exposed to BTs from antifouling paints used on ship hulls. Analytical conditions for organotin analysis in marine sediments were optimized for GC with pulsed flame photometric detection. Detection limits ranged from 8.4 to 66.3 ng g(-1) using a 610-nm filter, and the linearity range was 20-500 ng g(-1). Concentration levels of BTs were highest in Santos harbor (360 ng g(-1) TBT in average) and Guaruja marina (670 ng g(-1) TBT in average), which seems to be related to intensive boat traffic. Lower levels of BTs were observed in Cananeia, where only fishing boats are present (50 ng g(-1) TBT in average). (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The incomplete combustion of biomass is one of the most important sources of emissions of organic compounds into the atmosphere, like polycyclic aromatic hydrocarbons (PAHs) which show genotoxic activity. Since environmental samples generally contain interferents and trace amounts of PAHs of interest, concentration and clean-up procedures are usually required prior to the final chromatographic analysis. This paper discusses the performance of Sep-Pak cartridges (silica gel and RP18) on clean-up of sugar cane soot extract. The best results were obtained with a silica Sep-Pak cartridge. The recoveries ranged from 79% (benzo[b]fluoranthene) to 113% (benzo[e]pyrene). (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organotin compounds, largely used as biocides in antifouling paints, are among the most toxic materials introduced into the aquatic environment. Sensitive analytical methods are thus required to characterize their occurrence in environmental and biological matrices. The comparison between two different photometric detectors in terms of analytical performance was carried out for the analysis of organotin compounds. A flame photometric detector (FPD) and a pulsed flame photometric detector (PFPD) were optimized. Their respective sensitivity, linearity range and selectivity were evaluated. Limits of detection obtained for a tributyltin compound (TBT) were 5.0 and 0.9 pg (as Sn) for the FPD and PFPD, respectively, using a 390 nm filter. The PFPD showed higher selectivity, besides reduced gas consumption in the flame, and is very attractive for organotin compound speciation in complex environmental matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that an extra constant of motion with an analytic form can exist in the neighborhood of some discrete circular orbits of helium when one includes retardation and self-interaction effects. The energies of these discrete stable circular orbits are in the correct atomic magnitude. The highest frequency in the stable manifold of one such orbit agrees with the highest frequency sharp line of parahelium to within 2%. The generic term of the frequency in the stable manifold to higher orbits is also in agreement with the asymptotic form of quantum mechanics for helium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT). The Cd2+ ions were sorbed at pH 5.0. The preconcentrated Cd2+ ions were directly eluted from the column to the spectrometer's nebulizer-burner system using 100 μL of 2 mol L-1 hydrochloric acid. A retention efficiency of over 95% was achieved. The enrichment factor (calculated as the ratio of slopes of the calibration graphs) obtained with preconcentrations in a mini-column packed with SiAT (A = -1.3 × 10-3 + 1.8 × 10-3 [Cd2+]) and without preconcentrations (A = 4 × 10-5 + 3.5 × 10-3[Cd2+]), was 51 and the detection limit calculated was 0.38 μg L-1. The preconcentration procedure was applied to determine trace levels of Cd in river water samples. The optimum preconcentration conditions are discussed herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.