933 resultados para fast timing, singlephoto-electron, frontend electronics, Time-over-Threshold, PID


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Annualising work hours (AH) is a means of achievement flexibility in the use of human resources to face the seasonal nature of demand. In Corominas et al. (1) two MILP models are used to solve the problem of planning staff working hours with annual horizon. The costs due to overtime and to the employment of temporary workers are minimised, and the distribution of working time over the course of the year for each worker and the distribution of working time provided by temporary workers are regularised.In the aforementioned paper, the following is assumed: (i) the holiday weeks are fixed a priori and (ii) the workers are from different categories who are able to perform specific type of task have se same efficiency; moreover, the values of the binary variables (and others) in the second model are fixed to those in the first model (thus, in the second model these will intervene as constants and not as variables, resulting in an LP model).In the present paper, these assumptions are relaxed and a more general problem is solved. The computational experiment leads to the conclusion that MILP is a technique suited to dealing with the problem.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El projecte està basat en la creació d'una aplicació per dispositius mòbils android i que fent servir l'ús del micròfon capturi el so que genera l'usuari i pugui determinar si s'està respirant i en quin punt de la respiració es troba l'usuari. S'ha dut a terme una filosofia de disseny orientada a l'usuari (DCU) de manera que el primer pas ha sigut realitzar un prototip i un 'sketch'. A continuació, s'han realitzat 10 aplicacions test i en cadascuna d'elles s'ha ampliat la funcionalitat fins a arribar a obtenir una aplicació base que s'aproxima al disseny inicial generat per mitjà del prototip. El més important dels dissenys algorísmics que s'han realitzat per la aplicació es la capacitat de processar el senyal en temps real, ja que fins i tot s'ha pogut aplicar la transformada ràpida de Fourier (FFT) en temps real sense que el rendiment de l'aplicació es veies afectat. Això ha sigut possible gràcies al disseny del processament amb doble buffer i amb un fil d'execució dedicat independent del fil principal d'execució del programa 'UI Thread'

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years correlative microscopy, combining the power and advantages of different imaging system, e.g., light, electrons, X-ray, NMR, etc., has become an important tool for biomedical research. Among all the possible combinations of techniques, light and electron microscopy, have made an especially big step forward and are being implemented in more and more research labs. Electron microscopy profits from the high spatial resolution, the direct recognition of the cellular ultrastructure and identification of the organelles. It, however, has two severe limitations: the restricted field of view and the fact that no live imaging can be done. On the other hand light microscopy has the advantage of live imaging, following a fluorescently tagged molecule in real time and at lower magnifications the large field of view facilitates the identification and location of sparse individual cells in a large context, e.g., tissue. The combination of these two imaging techniques appears to be a valuable approach to dissect biological events at a submicrometer level. Light microscopy can be used to follow a labelled protein of interest, or a visible organelle such as mitochondria, in time, then the sample is fixed and the exactly same region is investigated by electron microscopy. The time resolution is dependent on the speed of penetration and fixation when chemical fixatives are used and on the reaction time of the operator for cryo-fixation. Light microscopy can also be used to identify cells of interest, e.g., a special cell type in tissue or cells that have been modified by either transfections or RNAi, in a large population of non-modified cells. A further application is to find fluorescence labels in cells on a large section to reduce searching time in the electron microscope. Multiple fluorescence labelling of a series of sections can be correlated with the ultrastructure of the individual sections to get 3D information of the distribution of the marked proteins: array tomography. More and more efforts are put in either converting a fluorescence label into an electron dense product or preserving the fluorescence throughout preparation for the electron microscopy. Here, we will review successful protocols and where possible try to extract common features to better understand the importance of the individual steps in the preparation. Further the new instruments and software, intended to ease correlative light and electron microscopy, are discussed. Last but not least we will detail the approach we have chosen for correlative microscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rice is a major staple in many countries. Weed control is one of the factors limiting higher rice yield. ALS (acetolactate synthase)-inhibiting herbicides are desirable weed control herbicides because of their high efficacy, low toxicity to mammalians, and low rates used. An important herbicide characteristic is high selectivity to the crop, since it facilitates fast crop establishment and greater crop advantage over the weeds. The objectives of this work were to study the effects of increasing rates of the ALS-inhibiting herbicide penoxsulam on seed integrity and germination, and seedling and plant development of rice cv. BRS Pelota under controlled laboratory and greenhouse conditions. The results showed that penoxsulam affected rice germination and seedling and plant growth at rates above 54 g a.i. ha-1, and that penoxsulam is safe for rice seedling development at the currently recommended rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tämä Pro Gradu -tutkielma tarkastelee Pohjoismaisten yhdistelmärahastojen menestymistä vuosina 1999–2012. Tutkimuksen tavoitteena on tutkia rahastonhoitajien markkina-ajoituskykyä kolmella eri periodilla. Periodit koostuvat vuosista 1999–2005, 2006–2012 ja 1999–2012. Tutkimuksessa käytetään monia tunnettuja riskin huomioivia mittareita, kuten esimerkiksi Sharpen indeksiä ja Jensenin alfaa. Markkina-ajoituskykyä testataan Treynor-Mazuy ja Henriksson-Merton -malleilla. Tutkimus osoittaa, että vain harvoilla rahastonhoitajilla on markkina-ajoituskykyä. Tutkimuksesta ei myöskään löydetä viitteitä siitä, että tietyn-tyyppiset yhdistelmärahastot suoriutuisivat paremmin markkinoilla.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the link between macroeconomic news announcements and exchange rates is well documented in recent literature, this connection may be unstable. By using a broad set of macroeconomic news announcements and high frequency forex data for the Euro/Dollar, Pound/Dollar and Yen/Dollar from Nov 1, 2004 to Mar 31, 2014, we obtain two major findings with regards to this instability. First, many macroeconomic news announcements exhibit unstable effects with certain patterns in foreign exchange rates. These news effects may change in magnitude and even in their sign over time, over business cycles and crises within distinctive contexts. This finding is robust because the results are obtained by applying a Two-Regime Smooth Transition Regression Model, a Breakpoints Regression Model, and an Efficient Test of Parameter Instability which are all consistent with each other. Second, when we explore the source of this instability, we find that global risks and the reaction by central bank monetary policy to these risks to be possible factors causing this instability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the twentieth century, the allocation of womens' time changed dramatically. This paper explores the implications for the allocation of married womens' time stemming from: (1) the household revolution associated with the introduction of a variety of labor-saving devices in the home; (2) the remarkable increase in the relative wage of women; and (3) changes in childcare requirements associated with changes in fertility patterns. To do so, we construct a life-cycle model with home production and childcare constraints. The parameters of the childcare production function are estimated using micro evidence from U.S. time use data. We find that the increase in the relative wage of women is the most important explanation of the increase in married womens' market work time over the twentieth century. Changes in fertility had large effects up to 1980, but little effect thereafter. The declining price of durables has an appreciable effect only since 1980, an effect that is consistent with a broader interpretation of durable goods reflecting the marketization of home production.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La spectroscopie infrarouge à matrice à plan focal (PAIRS) est utilisée pour étudier la déformation et la relaxation des polymères à très haute vitesse, soit de 46 cm/s, grâce à sa résolution temporelle de quelques millisecondes. Des mesures complémentaires de spectroscopie infrarouge d’absorbance structurale par modulation de la polarisation (PM-IRSAS) ont été réalisées pour suivre des déformations plus lentes de 0,16 à 1,6 cm/s avec une résolution temporelle de quelques centaines de millisecondes. Notre étude a permis d’observer, à haute vitesse de déformation, un nouveau temps de relaxation (τ0) de l’ordre d’une dizaine de millisecondes qui n’est pas prédit dans la littérature. Le but de cette étude est de quantifier ce nouveau temps de relaxation ainsi que de déterminer les effets de la température, de la masse molaire et de la composition du mélange sur ce dernier. Des mesures effectuées sur du polystyrène (PS) de deux masses molaires différentes, soit 210 et 900 kg/mol, à diverses températures ont révélé que ce temps est indépendant de la masse molaire mais qu’il varie avec la température. Des mesures effectuées sur des films composés de PS900 et de PS deutéré de 21 kg/mol, ont révélé que ce temps ne dépend pas de la composition du mélange et que la longueur des chaînes de PS n’a aucun impact sur celui-ci. D’autres mesures effectuées sur des films de PS900 mélangé avec le poly(vinyl méthyl éther) (PVME) ont révélé que ce temps est identique pour le PS900 pur et le PS900 dans le mélange, mais qu’il est plus court pour le PVME, de l’ordre de quelques millisecondes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents an explicit formulation for multiple- edge diffraction for mobile radiowave propagation in terms of uniform theory of diffraction (UTD) coefficients when a spherical incident wave is considered. This solution can be used in an UTD context and sharply reduces the computing time over existing formulation. Results can be applied in the planning of microcellular systems

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Path planning and control strategies applied to autonomous mobile robots should fulfil safety rules as well as achieve final goals. Trajectory planning applications should be fast and flexible to allow real time implementations as well as environment interactions. The methodology presented uses the on robot information as the meaningful data necessary to plan a narrow passage by using a corridor based on attraction potential fields that approaches the mobile robot to the final desired configuration. It employs local and dense occupancy grid perception to avoid collisions. The key goals of this research project are computational simplicity as well as the possibility of integrating this method with other methods reported by the research community. Another important aspect of this work consist in testing the proposed method by using a mobile robot with a perception system composed of a monocular camera and odometers placed on the two wheels of the differential driven motion system. Hence, visual data are used as a local horizon of perception in which trajectories without collisions are computed by satisfying final goal approaches and safety criteria

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La propuesta WMS Cached (WMS-C) surge ante la necesidad de disponer de una solución más escalable al actual servicio web de mapas (WMS). Mediante la limitación de los parámetros de las peticiones a un conjunto discreto de valores, el servidor de mapas puede servir imágenes pregeneradas (teselas) a gran velocidad. En este documento se recogen las medidas de rendimiento realizadas sobre las implementaciones WMS-C: Tilecache, GeoWebcache y WMSCWrapper, todas ellas basadas en software libre. Los resultados de los benchmarks reflejan que, con todas las peticiones cacheadas y bajo las mismas condiciones, la caché WMSCWrapper ofrece un mejor rendimiento que las otras implementaciones. La difusión de estos resultados será de utilidad para ayudar a diversas entidades en la elección de una de estas soluciones libres en función de su objetivo de optimización

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plasma parcels are observed propagating from the Sun out to the large coronal heights monitored by the Heliospheric Imagers (HI) instruments onboard the NASA STEREO spacecraft during September 2007. The source region of these out-flowing parcels is found to corotate with the Sun and to be rooted near the western boundary of an equatorial coronal hole. These plasma enhancements evolve during their propagation through the HI cameras’ fields of view and only becoming fully developed in the outer camera field of view. We provide evidence that HI is observing the formation of a Corotating Interaction Region(CIR) where fast solar wind from the equatorial coronal hole is interacting with the slow solar wind of the streamer belt located on the western edge of that coronal hole. A dense plasma parcel is also observed near the footpoint of the observed CIR at a distance less than 0.1AU from the Sun where fast wind would have not had time to catch up slow wind. We suggest that this low-lying plasma enhancement is a plasma parcel which has been disconnected from a helmet streamer and subsequently becomes embedded inside the corotating interaction region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To clarify the role of growth monitoring in primary school children, including obesity, and to examine issues that might impact on the effectiveness and cost-effectiveness of such programmes. Data sources: Electronic databases were searched up to July 2005. Experts in the field were also consulted. Review methods: Data extraction and quality assessment were performed on studies meeting the review's inclusion criteria. The performance of growth monitoring to detect disorders of stature and obesity was evaluated against National Screening Committee (NSC) criteria. Results: In the 31 studies that were included in the review, there were no controlled trials of the impact of growth monitoring and no studies of the diagnostic accuracy of different methods for growth monitoring. Analysis of the studies that presented a 'diagnostic yield' of growth monitoring suggested that one-off screening might identify between 1: 545 and 1: 1793 new cases of potentially treatable conditions. Economic modelling suggested that growth monitoring is associated with health improvements [ incremental cost per quality-adjusted life-year (QALY) of pound 9500] and indicated that monitoring was cost-effective 100% of the time over the given probability distributions for a willingness to pay threshold of pound 30,000 per QALY. Studies of obesity focused on the performance of body mass index against measures of body fat. A number of issues relating to human resources required for growth monitoring were identified, but data on attitudes to growth monitoring were extremely sparse. Preliminary findings from economic modelling suggested that primary prevention may be the most cost-effective approach to obesity management, but the model incorporated a great deal of uncertainty. Conclusions: This review has indicated the potential utility and cost-effectiveness of growth monitoring in terms of increased detection of stature-related disorders. It has also pointed strongly to the need for further research. Growth monitoring does not currently meet all NSC criteria. However, it is questionable whether some of these criteria can be meaningfully applied to growth monitoring given that short stature is not a disease in itself, but is used as a marker for a range of pathologies and as an indicator of general health status. Identification of effective interventions for the treatment of obesity is likely to be considered a prerequisite to any move from monitoring to a screening programme designed to identify individual overweight and obese children. Similarly, further long-term studies of the predictors of obesity-related co-morbidities in adulthood are warranted. A cluster randomised trial comparing growth monitoring strategies with no growth monitoring in the general population would most reliably determine the clinical effectiveness of growth monitoring. Studies of diagnostic accuracy, alongside evidence of effective treatment strategies, could provide an alternative approach. In this context, careful consideration would need to be given to target conditions and intervention thresholds. Diagnostic accuracy studies would require long-term follow-up of both short and normal children to determine sensitivity and specificity of growth monitoring.