957 resultados para false negative rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: Screening programs to detect visual abnormalities in children vary among countries. The aim of this study is to describe experts' perception of best practice guidelines and competency framework for visual screening in children. METHODS: A qualitative focus group technique was applied during the Portuguese national orthoptic congress to obtain the perception of an expert panel of 5 orthoptists and 2 ophthalmologists with experience in visual screening for children (mean age 53.43 years, SD ± 9.40). The panel received in advance a script with the description of three tuning competencies dimensions (instrumental, systemic, and interpersonal) for visual screening. The session was recorded in video and audio. Qualitative data were analyzed using a categorical technique. RESULTS: According to experts' views, six tests (35.29%) have to be included in a visual screening: distance visual acuity test, cover test, bi-prism or 4/6(Δ) prism, fusion, ocular movements, and refraction. Screening should be performed according to the child age before and after 3 years of age (17.65%). The expert panel highlighted the influence of the professional experience in the application of a screening protocol (23.53%). They also showed concern about the false negatives control (23.53%). Instrumental competencies were the most cited (54.09%), followed by interpersonal (29.51%) and systemic (16.4%). CONCLUSIONS: Orthoptists should have professional experience before starting to apply a screening protocol. False negative results are a concern that has to be more thoroughly investigated. The proposed framework focuses on core competencies highlighted by the expert panel. Competencies programs could be important do develop better screening programs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução – O melanoma maligno cutâneo (MMC) é considerado uma das mais letais neoplasias e no seu seguimento recorre-se, para além dos exames clínicos e da análise de marcadores tumorais, a diversos métodos imagiológicos, como é o exame Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT, do acrónimo inglês Positron Emission Tomography/Computed Tomography) com 18fluor-fluorodeoxiglucose (18F-FDG). O presente estudo tem como objetivo avaliar a utilidade da PET/CT relativamente à análise da extensão e à suspeita de recidiva do MMC, comparando os achados imagiológicos com os descritos em estudos CT. Metodologia – Estudo retrospetivo de 62 estudos PET/CT realizados em 50 pacientes diagnosticados com MMC. Excluiu-se um estudo cujo resultado era duvidoso (nódulo pulmonar). As informações relativas aos resultados dos estudos anatomopatológicos e dos exames imagiológicos foram obtidas através da história clínica e dos relatórios médicos dos estudos CT e PET/CT. Foi criada uma base de dados com os dados recolhidos através do software Excel e foi efetuada uma análise estatística descritiva. Resultados – Dos estudos PET/CT analisados, 31 foram considerados verdadeiros positivos (VP), 28 verdadeiros negativos (VN), um falso positivo (FP) e um falso negativo (FN). A sensibilidade, especificidade, o valor preditivo positivo (VPP), o valor preditivo negativo (VPN) e a exatidão da PET/CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 96,9%, 96,6%, 96,9%, 96,6% e 96,7%. Dos resultados da CT considerados na análise estatística, 14 corresponderam a VP, 12 a VN, três a FP e cinco a FN. A sensibilidade, especificidade, o VPP e o VPN e a exatidão da CT para o estadiamento e avaliação de suspeita de recidiva no MMC são, respetivamente, 73,7%, 80,0%, 82,4%, 70,6% e 76,5%. Comparativamente aos resultados CT, a PET/CT permitiu uma mudança na atitude terapêutica em 23% dos estudos. Conclusão – A PET/CT é um exame útil na avaliação do MMC, caracterizando-se por uma maior acuidade diagnóstica no estadiamento e na avaliação de suspeita de recidiva do MMC comparativamente à CT isoladamente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The presence of circulating immune complexes formed by IgM and IgG (CIC-IgM and CIC-IgG) was investigated, using antigen-specific enzyme-immunoassays (ELISA), in 30 patients with acute Chagas' disease who showed parasitemia and inoculation chagoma. Control population consisted of patients with chronic T. cruzi infection (30), acute toxoplasmosis 10), leishmaniasis (8), rheumatoid arthritis (3) and healthy individuals with negative serology for Chagas* disease (30). Acute chagasic patients were 100% CIC-IgG and 96.66% CIC-IgM positive whereas immunofluorescence tests yielded 90% and 86.66% of positivity for specific IgG and IgM antibodies, respectively. Chronic patients were 68% CIC-IgG and 0% CIC-IgM positive. The 30 negative and the 21 cross-reaction controls proved negative for ELISA (CIC-IgM and CIC-IgG). The high sensitivity of ELISA assays would allow early immunologic diagnosis, as well as prompt treatment, of acute T. cruzi infection, thus eliminating the problem of the false-positive and false-negative results which affects traditional methods for detection of circulating antibodies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sera from the patients (N = 10) with schistosomiasis mansoni of the hospital of Federal University of Pernambuco, the Schistosoma mansoni egg-positive (N = 51) and -negative (N = 452) inhabitants in Cabo City area, out-patients (N = 37) of the IMIP hospital and Japanese immigrants (N = 127) in Petrolina City area of northeast Brazil as well as Japanese healthy subjects (N = 30) were examined by serological tests including an enzyme-linked immunosorbent assay with antigens prepared from eggs (ELISA-egg) and adult worms (ELISA-adult). The ELISA with egg or adult antigen correctly identified 100% of the uninfected individuals lived in non-endemic area of schistosomiasis. Moreover, when examined cross-reactivity of our ELISA with sera isolated from 78 subjects infected with various intestinal parasitic infections, only one of these sera reacted with the egg and adult antigens. On the examination of 51 sera from the egg-positive subjects, the ELISA-egg revealed the highest sensitivity (98.0%), whereas a large number of false negative reactions of ELISA-adult, Ouchterlony method using adult antigen, circumoval precipitation and immediate intradermal skin test were observed. A low sensitivity of these serologic tests except for ELISA-egg appears to be primarily due to their inability to detect antibody in the sera from egg-positive infantiles. There was no positive correlation between the absorbance values of these two types of ELISA among the sera isolated from ELISA-positive subjects. Rather, by the reactivity of these sera to egg or adult antigen, they could be divided into two subgroups; one reacted more positively with egg antigen and the other with adult antigen. Moreover, it was confirmed that the sera from young subjects (under 20 years old) appear to be highly reactive to the egg antigen than did aged ones. These data suggest that the ELISA with egg antigen, but not with the adult antigen, appears to be useful for the serological survey of schistosomiasis mansoni in the endemic area of northeast Brazil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is known that fecal examination to detect Giardia lamblia cysts or trophozoites produces a high percentage of false-negative results. A commercially available immunoenzymatic assay (ProSpecT Giardia Microplate Assay, Alexon, Inc., BIOBRÁS) to detect G. lamblia specific coproantigen was evaluated for the first time in Brazil. A total of 90 specimens were tested. Each specimen was first tested as unpreserved stool, and then it was preserved in 10% Formalin to be tested 2 months later. The assay was able to identify all the 30 positive patients (sensitivity = 100.0%) by visual or spectrophotometric examination in the unpreserved specimens and was negative in 57 of the 60 patients without G. lamblia (specificity = 95.0%). The assay identified 27 of the 30 positive patients (sensitivity = 90.0%) and was negative in 59 of the 60 negatives (specificity = 98.3%) in the preserved stools according to both readings. A marked difference was observed in the optical densities in both groups, preserved and unpreserved stools, when the G. lamblia-positive specimens were compared to the negative or positive for other intestinal parasites than G. lamblia. The assay seems a good alternative for giardiasis diagnosis, especially when the fecal examination was repeatedly negative and the patient presents giardiasislike symptoms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aims to evaluate the impact of drug treatment on infection by Ascaris lumbricoides (Al), Trichuris trichiura (Tt) and hookworms (Hook) in a rural community from the sugar-cane zone of Pernambuco, Brazil. Four parasitological surveys were carried out from March 2001 to March 2002. Individual diagnosis was based on eight slides (four by the Kato-Katz method and four by the Hoffman method) per survey. Infected subjects were assigned to two groups for treatment with either albendazole (n = 62) or mebendazole (n = 57). Prevalence of infection fell significantly (p < 0.05) one month after treatment: Al (from 47.7% to 6.6%); Tt (from 45.7% to 31.8%) and Hook (from 47.7% to 24.5%). One year after treatment, infections by Tt and Hook remained significantly below pre-control levels. A substantial decrease in single-infection cases and multiple infections was found. Egg-negative rate was significant for Al (94.0%), Hook (68.3%) but not for Tt (45.5%), and did not differ significantly between subjects treated with mebendazole or albendazole. Egg counts fell significantly in the individuals remaining positive for Tt. It is recommended that antihelminthic treatment should be selective and given at yearly intervals preferably with albendazole, due to its cost-effectiveness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the frequency and severity of the anomalous origin of the left coronary artery (ALCA) from the pulmonary artery (PA). DESIGN OF THE STUDY: Prospective study of case series between March 1991 and December 1994. SETTING: Referral-based Paediatric Cardiology Department of a Tertiary Care Center. PATIENTS AND METHODS: Five consecutive patients (pts) with anomalous origin of the LCA from the PA; there were three infants aged 4 months and two children one 8 year and one 9 year old. There were three girls and two boys. All pts had clinical and 2D-echo and Doppler investigation prior to cardiac catheterization (CC). Indication for CC was based in the association of symptoms and signs of myocarditis or dilated cardiomyopathy of acute or subacute onset and electrocardiographic (ECG) signs of ischemia in infants. In older patients (pts) diagnosis was suspected mainly from ECG. During CC in all pts, aortograms and when necessary selective coronary angiograms were performed. Surgical correction was performed in all children. In two pts stress exercise ECG and stress Thallium studies before and after surgery were performed. RESULTS: two pts had "adult" an three had "infantile" type of ALCA from the PA. CC was performed and diagnosis was confirmed at surgery in all cases. In one child, correct diagnosis was made by ECO prior to CC and in one case LCA to PA fistula was suspected on Colour-Doppler study. No complications were attributed to CC. Several types of surgery were performed: reimplantation of the ALCA from the PA to the aorta (three pts); tunnel connection of the aorta to the ALCA via the PA (one pt) and left internal mammary to LCA anastomosis (one pt). Two infants died intraoperatively due to extensive myocardial infarction and poor left ventricular function. All the three survivors are asymptomatic after a mean follow up of 34 months. Two oldest pts are currently in New York Heart Association functional class I with normal ECG and improved myocardial perfusion on Thallium scan despite almost total occlusion of LCA at the site of implantation in the aorta as diagnosed on coronary angiogram. CONCLUSIONS: ALCA from PA is associated with major morbidity and mortality. Diagnosis should be suspected in pts with unexplained myocardial ischemia on ECG and even more if it is associated to clinical signs of dilated cardiomyopathy or myocarditis. Careful assessment on ECO and pulsed Doppler and colour flow mapping should make the diagnosis in most cases. Although surgery can be performed based only on ECO diagnosis, we strongly advise for angiography in all cases as in our experience there are false negative diagnosis by ECO. Preoperative Thallium studies can be useful for the selection of the type of surgery as pts with very little viable myocardium will not survive the establishment of a direct systemic to coronary blood flow and may be candidates for heart transplantation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: Evaluate the sensitivity/specificity of immunoperoxidase method in comparison with the standard immunofluorescence. MATERIAL AND METHODS: Retrospective review of 87 biopsies made for allograft dysfunction. Immunofluorescence (IF) was performed in frozen allograft biopsies using monoclonal antibody anti-C4d from Quidel®. The indirect immunoperoxidase (IP) technique was performed in paraffin-embebbed tissue with polyclonal antiserum from Serotec®. Biopsies were independently evaluated by two nephropathologist according Banff 2007 classification. RESULTS: By IF, peritubular C4d deposition were detected in 60 biopsies and absent in 27 biopsies. The evaluation of biopsy by IP was less precise due to the presence of background and unspecific staining. We find 13.8% (12/87) of false negative and Banff classification concordance in 79.3% (69/87) of cases (table1). The ROC curve study reveal a specificity of 100% and sensitivity of 80.0 % of IP method in relation to the gold standard (area under curve:0.900; 95% Confidence interval :0.817-0.954; p=0.0001). Banff Classification C4d Cases Immunofluorescence Immunoperoxidase n =87 Diffuse Negative 3 (3.4%) Focal Negative 9 (10.3%) Negative Negative 27 (31.0%) Diffuse Diffuse 33 (37.9%) Focal Focal 9 (10.3%) Diffuse Focal 6 (6.9%) CONCLUSION: The IP method presents a good specificity, but lesser sensitivity to C4d detection in allograft dysfunction. The evaluation is more difficult, requiring more experience of the observer than IF method. If frozen tissue is unavailable, the use of IP for C4d detection is acceptable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of our study was to evaluate the accuracy of dynamic incremental bolus-enhanced conventional CT (DICT) with intravenous contrast administration, early phase, in the diagnosis of malignancy of focal liver lesions. A total of 122 lesions were selected in 74 patients considering the following criteria: lesion diameter 10 mm or more, number of lesions less than six per study, except in multiple angiomatosis and the existence of a valid criteria of definitive diagnosis. Lesions were categorized into seven levels of diagnostic confidence of malignancy compared with the definitive diagnosis for acquisition of a receiver-operator-characteristic (ROC) curve analysis and to determine the sensitivity and specificity of the technique. Forty-six and 70 lesions were correctly diagnosed as malignant and benign, respectively; there were 2 false-positive and 4 false-negative diagnoses of malignancy and the sensitivity and specificity obtained were 92 and 97%. The DICT early phase was confirmed as a highly accurate method in the characterization and diagnosis of malignancy of focal liver lesions, requiring an optimal technical performance and judicious analysis of existing semiological data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Predicting outcome in comatose survivors of cardiac arrest is based on data validated by guidelines that were established before the era of therapeutic hypothermia. We sought to evaluate the predictive value of clinical, electrophysiological and imaging data on patients submitted to therapeutic hypothermia. MATERIALS AND METHODS: A retrospective analysis of consecutive patients receiving therapeutic hypothermia during years 2010 and 2011 was made. Neurological examination, somatosensory evoked potentials, auditory evoked potentials, electroencephalography and brain magnetic resonance imaging were obtained during the first 72 hours. Glasgow Outcome Scale at 6 months, dichotomized into bad outcome (grades 1 and 2) and good outcome (grades 3, 4 and 5), was defined as the primary outcome. RESULTS: A total of 26 patients were studied. Absent pupillary light reflex, absent corneal and oculocephalic reflexes, absent N20 responses on evoked potentials and myoclonic status epilepticus showed no false-positives in predicting bad outcome. A malignant electroencephalographic pattern was also associated with a bad outcome (p = 0.05), with no false-positives. Two patients with a good outcome showed motor responses no better than extension (false-positive rate of 25%, p = 0.008) within 72 hours, both of them requiring prolonged sedation. Imaging findings of brain ischemia did not correlate with outcome. DISCUSSION: Absent pupillary, corneal and oculocephalic reflexes, absent N20 responses and a malignant electroencephalographic pattern all remain accurate predictors of poor outcome in cardiac arrest patients submitted to therapeutic hypothermia. CONCLUSION: Prolonged sedation beyond the hypothermia period may confound prediction strength of motor responses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Schistosomiasis constitutes a major public health problem, with an estimated 200 million individuals infected worldwide and 700 million people living in risk areas. In Brazil there are areas of high, medium and low endemicity. Studies have shown that in endemic areas with a low prevalence of Schistosoma infection the sensitivity of parasitological methods is clearly reduced. Consequently diagnosis is often impeded due to the presence of false-negative results. The aim of this study is to present the PCR reamplification (Re-PCR) protocol for the detection of Schistosoma mansoni in samples with low parasite load (with less than 100 eggs per gram (epg) of feces). Three methods were used for the lysis of the envelopes of the S. mansoni eggs and two techniques of DNA extraction were carried out. Extracted DNA was quantified, and the results suggested that the extraction technique, which mixed glass beads with a guanidine isothiocyanate/phenol/chloroform (GT) solution, produced good results. PCR reamplification was conducted and detection sensitivity was found to be five eggs per 500 mg of artificially marked feces. The results achieved using these methods suggest that they are potentially viable for the detection of Schistosoma infection with low parasite load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The clinical application of CCR5 antagonists involves first determining the coreceptor usage by the infecting viral strain. Bioinformatics programs that predict coreceptor usage could provide an alternative method to screen candidates for treatment with CCR5 antagonists, particularly in countries with limited financial resources. Thus, the present study aims to identify the best approach using bioinformatics tools for determining HIV-1 coreceptor usage in clinical practice. Proviral DNA sequences and Trofile results from 99 HIV-1-infected subjects under clinical monitoring were analyzed in this study. Based on the Trofile results, the viral variants present were 81.1% R5, 21.4% R5X4 and 1.8% X4. Determination of tropism using a Geno2pheno[coreceptor] analysis with a false positive rate of 10% gave the most suitable performance in this sampling: the R5 and X4 strains were found at frequencies of 78.5% and 28.4%, respectively, and there was 78.6% concordance between the phenotypic and genotypic results. Further studies are needed to clarify how genetic diversity amongst virus strains affects bioinformatics-driven approaches for determining tropism. Although this strategy could be useful for screening patients in developing countries, some limitations remain that restrict the wider application of coreceptor usage tests in clinical practice.