964 resultados para external validation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

SETTING: Kinshasa Province, Democratic Republic of Congo. OBJECTIVE: To identify and validate register-based indicators of acid-fast bacilli (AFB) microscopy quality. DESIGN: Selection of laboratories based on reliability and variation in routine smear rechecking results. Calculation of relative sensitivity (RS) compared to recheckers and its correlation coefficient (R) with candidate indicators based on a fully probabilistic analysis incorporating vague prior information using WinBUGS. RESULTS: The proportion of positive follow-up smears correlated well (median R 0.81, 95% credibility interval [CI] 0.58-0.93), and the proportion of first smear-positive cases fairly (median R 0.70, 95% CI 0.38-0.89) with RS. The proportions of both positive suspect and low positive case smears showed poor correlations (median R 0.27 and -0.22, respectively, with ranges including zero). CONCLUSIONS: The proportion of positives in follow-up smears is the most promising indicator of AFB smear sensitivity, while the proportion of positive suspects may be more indicative of accessibility and suspect selection. Both can be obtained from simple reports, and should be used for internal and external monitoring and as guidance for supervision. As proportion of low positive suspect smears and consistency within case series are more difficult to interpret, they should be used only on-site by laboratory professionals. All indicators require more research to define their optimal range in various settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The aim of this study was to determine which of two clinically applied methods, electromyography or acceleromyography, was less affected by external disturbances, had a higher sensitivity and which would provide the better input signal for closed loop control of muscle relaxation. METHODS: In 14 adult patients, anaesthesia was induced with intravenous opioids and propofol. The response of the thumb to ulnar nerve stimulation was recorded on the same arm. Mivacurium was used for neuromuscular blockade. Under stable conditions of relaxation, the infusion-rate was decreased and the effects of turning the hand were investigated. RESULTS: Electromyography and acceleromyography both reflected the change of the infusion rate (P = 0.015 and P < 0.001, respectively). Electromyography was significantly less affected by the hand-turn (P = 0.008) than acceleromyography. While zero counts were detected with acceleromyography, electromyography could still detect at least one count in 51.1%. CONCLUSIONS: Electromyography is more reliable for use in daily practice as it is less influenced by external disturbances than acceleromyography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundAnatomical differences between humans and domestic mammals preclude the use of reported stereotactic approaches to the brainstem in animals. In animals, brainstem biopsies are required both for histopathological diagnosis of neurological disorders and for research purposes. Sheep are used as a translational model for various types of brain disease and therefore a species-specific approach needs to be developed. The aim of the present study was to establish a minimally invasive, accurate and reproducible stereotactic approach to the brainstem of sheep, using the magnetic resonance imaging guided BrainsightTM frameless stereotactic system.ResultsA transoccipital transcerebellar approach with an entry point in the occipital bone above the vermis between the transverse sinus and the external occipital protuberance was chosen. This approach provided access to the target site in all heads. The overall mean needle placement error was 1.85¿±¿1.22 mm.ConclusionsThe developed transoccipital transcerebellar route is short, provides accurate access to the ovine caudal cranial fossa and is a promising approach to be assessed further in live animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE External beam radiation therapy is currently considered the most common treatment modality for intraocular tumors. Localization of the tumor and efficient compensation of tumor misalignment with respect to the radiation beam are crucial. According to the state of the art procedure, localization of the target volume is indirectly performed by the invasive surgical implantation of radiopaque clips or is limited to positioning the head using stereoscopic radiographies. This work represents a proof-of-concept for direct and noninvasive tumor referencing based on anterior eye topography acquired using optical coherence tomography (OCT). METHODS A prototype of a head-mounted device has been developed for automatic monitoring of tumor position and orientation in the isocentric reference frame for LINAC based treatment of intraocular tumors. Noninvasive tumor referencing is performed with six degrees of freedom based on anterior eye topography acquired using OCT and registration of a statistical eye model. The proposed prototype was tested based on enucleated pig eyes and registration accuracy was measured by comparison of the resulting transformation with tilt and torsion angles manually induced using a custom-made test bench. RESULTS Validation based on 12 enucleated pig eyes revealed an overall average registration error of 0.26 ± 0.08° in 87 ± 0.7 ms for tilting and 0.52 ± 0.03° in 94 ± 1.4 ms for torsion. Furthermore, dependency of sampling density on mean registration error was quantitatively assessed. CONCLUSIONS The tumor referencing method presented in combination with the statistical eye model introduced in the past has the potential to enable noninvasive treatment and may improve quality, efficacy, and flexibility of external beam radiotherapy of intraocular tumors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An autonomous energy source within a human body is of key importance in the development of medical implants. This work deals with the modelling and the validation of an energy harvesting device which converts the myocardial contractions into electrical energy. The mechanism consists of a clockwork from a commercially available wrist watch. We developed a physical model which is able to predict the total amount of energy generated when applying an external excitation. For the validation of the model, a custom-made hexapod robot was used to accelerate the harvesting device along a given trajectory. We applied forward kinematics to determine the actual motion experienced by the harvesting device. The motion provides translational as well as rotational motion information for accurate simulations in three-dimensional space. The physical model could be successfully validated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ideologies face two critical problems in the reality, the problem of commitment and the problem of validation. Commitment and validation are two separate phenomena, in spite of the near universal myth that the human is committed because his beliefs are valid. Ideologies not only seem external and valid but also worth whatever discomforts believing entails. In this paper the authors develop a theory of social commitment and social validation using concepts of validation of neutrosophic logic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The representation of the thermal behaviour of the building is achieved through a relatively simple dynamic model that takes into account the effects due to the thermal mass of the building components. The model of a intra-floor apartment has been built in the Matlab-Simulink environment and considers the heat transmission through the external envelope, wall and windows, the internal thermal masses, (i.e. furniture, internal wall and floor slabs) and the sun gain due to opaque and see-through surfaces of the external envelope. The simulations results for the entire year have been compared and the model validated, with the one obtained with the dynamic building simulation software Energyplus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Screening of aphasia in acute stroke is crucial for directing patients to early language therapy. The Language Screening Test (LAST), originally developed in French, is a validated language screening test that allows detection of a language deficit within a few minutes. The aim of the present study was to develop and validate two parallel German versions of the LAST. METHODS The LAST includes subtests for naming, repetition, automatic speech, and comprehension. For the translation into German, task constructs and psycholinguistic criteria for item selection were identical to the French LAST. A cohort of 101 stroke patients were tested, all of whom were native German speakers. Validation of the LAST was based on (1) analysis of equivalence of the German versions, which was established by administering both versions successively in a subset of patients, (2) internal validity by means of internal consistency analysis, and (3) external validity by comparison with the short version of the Token Test in another subset of patients. RESULTS The two German versions were equivalent as demonstrated by a high intraclass correlation coefficient of 0.91. Furthermore, an acceptable internal structure of the LAST was found (Cronbach's α = 0.74). A highly significant correlation (r = 0.74, p < 0.0001) between the LAST and the short version of the Token Test indicated good external validity of the scale. CONCLUSION The German version of the LAST, available in two parallel versions, is a new and valid language screening test in stroke.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sharing of near real-time traceability knowledge in supply chains plays a central role in coordinating business operations and is a key driver for their success. However before traceability datasets received from external partners can be integrated with datasets generated internally within an organisation, they need to be validated against information recorded for the physical goods received as well as against bespoke rules defined to ensure uniformity, consistency and completeness within the supply chain. In this paper, we present a knowledge driven framework for the runtime validation of critical constraints on incoming traceability datasets encapuslated as EPCIS event-based linked pedigrees. Our constraints are defined using SPARQL queries and SPIN rules. We present a novel validation architecture based on the integration of Apache Storm framework for real time, distributed computation with popular Semantic Web/Linked data libraries and exemplify our methodology on an abstraction of the pharmaceutical supply chain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objectives: Lack of insight is a cardinal feature of psycho­sis. Insight has been found to be a multidimensional concept, including awareness of having a mental illness, ability to relabel psychotic phenomena as abnormal and compliance with treatment., which can be measured with the Schedule for Assessment of Insight (SAI-E). The aim of this study was to validate the Spanish version of SAI-E. Methods: The SAI-E was translated into Spanish and back-translated into English, which was deemed appropriate by the original scale author. Next, the Spanish version of the SAI-E was administered to 39 patients with schizophrenia or schizoaffective disorder (DSM-IV criteria) from a North Peruvian psychiatric hospital. The Positive and Negative Syndrome Scale for Schizophrenia (PANSS) and the Scale of Unawareness of Mental Disorder (SUMD) were also administered. Specifically, internal consistency and convergent validity were assessed. Results: Internal consistency between the 11 items of the SAI-E was found to be good to excellent (α = 0.942). Compliance items did not contribute to internal consistency (A = 0.417, B = 572). Inter-rater reliability was excellent (ICC = 0.99). Regarding concurrent validity, the SAI-E total score correlated negatively with the lack of insight and judgement item of the PANNS (r = -0.91, p <0.01) and positively with the SUMD total score (r = 0.92, p <0.001). Conclusions: The Spanish version of the SAI-E scale was demonstrated to have both excellent reliability and external validity in our sample of South American Spanish-speaking patients with schizophrenia spectrum disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shame is a social emotion with adaptive functions involved in human be-havior and social interactions. This emotion is regarded as an involuntary response associated with increased self-awareness, loss of status and self-devaluation (Gilbert, 1998), that may render individuals more prone to psychopathology (Gilbert, 1998; Pinto-Gouveia & Matos, 2011). Thus, identifying and assessing feelings of shame in childhood is essential in addressing the actual impact of shame on individual’s developmental trajectory. The Other As Shamer Scale (OAS; Goss, Gilbert & Allan, 1994) is a widely used measure of external shame, adapted and translated to several languages — including Portuguese (Matos, Pinto-Gouveia, Gilbert, Duarte & Figueiredo, 2015) — to adult and to adolescent populations (OASB-A - Other As Shamer Brief for adolescents; translated and adapted by Cunha, Xavier, Cherpe & Pinto-Gouveia, 2014). The current study aims to adapt and to explore the psychometric proper-ties of the brief OAS in a sample of Portuguese children attending to elementary schools.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efficient numerical models facilitate the study and design of solid oxide fuel cells (SOFCs), stacks, and systems. Whilst the accuracy and reliability of the computed results are usually sought by researchers, the corresponding modelling complexities could result in practical difficulties regarding the implementation flexibility and computational costs. The main objective of this article is to adapt a simple but viable numerical tool for evaluation of our experimental rig. Accordingly, a model for a multi-layer SOFC surrounded by a constant temperature furnace is presented, trained and validated against experimental data. The model consists of a four-layer structure including stand, two interconnects, and PEN (Positive electrode-Electrolyte-Negative electrode); each being approximated by a lumped parameter model. The heating process through the surrounding chamber is also considered. We used a set of V-I characteristics data for parameter adjustment followed by model verification against two independent sets of data. The model results show a good agreement with practical data, offering a significant improvement compared to reduced models in which the impact of external heat loss is neglected. Furthermore, thermal analysis for adiabatic and non-adiabatic process is carried out to capture the thermal behaviour of a single cell followed by a polarisation loss assessment. Finally, model-based design of experiment is demonstrated for a case study.