968 resultados para epidural anesthesia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several hypnosis monitoring systems based on the processed electroencephalogram (EEG) have been developed for use during general anesthesia. The assessment of the analgesic component (antinociception) of general anesthesia is an emerging field of research. This study investigated the interaction of hypnosis and antinociception, the association of several physiological variables with the degree of intraoperative nociception, and aspects of EEG Bispectral Index Scale (BIS) monitoring during general anesthesia. In addition, EEG features and heart rate (HR) responses during desflurane and sevoflurane anesthesia were compared. A propofol bolus of 0.7 mg/kg was more effective than an alfentanil bolus of 0.5 mg in preventing the recurrence of movement responses during uterine dilatation and curettage (D C) after a propofol-alfentanil induction, combined with nitrous oxide (N2O). HR and several HR variability-, frontal electromyography (fEMG)-, pulse plethysmography (PPG)-, and EEG-derived variables were associated with surgery-induced movement responses. Movers were discriminated from non-movers mostly by the post-stimulus values per se or normalized with respect to the pre-stimulus values. In logistic regression analysis, the best classification performance was achieved with the combination of normalized fEMG power and HR during D C (overall accuracy 81%, sensitivity 53%, specificity 95%), and with the combination of normalized fEMG-related response entropy, electrocardiography (ECG) R-to-R interval (RRI), and PPG dicrotic notch amplitude during sevoflurane anesthesia (overall accuracy 96%, sensitivity 90%, specificity 100%). ECG electrode impedances after alcohol swab skin pretreatment alone were higher than impedances of designated EEG electrodes. The BIS values registered with ECG electrodes were higher than those registered simultaneously with EEG electrodes. No significant difference in the time to home-readiness after isoflurane-N2O or sevoflurane-N2O anesthesia was found, when the administration of the volatile agent was guided by BIS monitoring. All other early and intermediate recovery parameters were also similar. Transient epileptiform EEG activity was detected in eight of 15 sevoflurane patients during a rapid increase in the inspired volatile concentration, and in none of the 16 desflurane patients. The observed transient EEG changes did not adversely affect the recovery of the patients. Following the rapid increase in the inhaled desflurane concentration, HR increased transiently, reaching its maximum in two minutes. In the sevoflurane group, the increase was slower and more subtle. In conclusion, desflurane may be a safer volatile agent than sevoflurane in patients with a lowered seizure threshold. The tachycardia induced by a rapid increase in the inspired desflurane concentration may present a risk for patients with heart disease. Designated EEG electrodes may be superior to ECG electrodes in EEG BIS monitoring. When the administration of isoflurane or sevoflurane is adjusted to maintain BIS values at 50-60 in healthy ambulatory surgery patients, the speed and quality of recovery are similar after both isoflurane-N2O and sevoflurane-N2O anesthesia. When anesthesia is maintained by the inhalation of N2O and bolus doses of propofol and alfentanil in healthy unparalyzed patients, movement responses may be best avoided by ensuring a relatively deep hypnotic level with propofol. HR/RRI, fEMG, and PPG dicrotic notch amplitude are potential indicators of nociception during anesthesia, but their performance needs to be validated in future studies. Combining information from different sources may improve the discrimination of the level of nociception.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Enhanced recovery after surgery (ERAS) is a multimodal approach to perioperative care that combines a range of interventions to enable early mobilization and feeding after surgery. We investigated the feasibility, clinical effectiveness, and cost savings of an ERAS program at a major U. S. teaching hospital. METHODS: Data were collected from consecutive patients undergoing open or laparoscopic colorectal surgery during 2 time periods, before and after implementation of an ERAS protocol. Data collected included patient demographics, operative, and perioperative surgical and anesthesia data, need for analgesics, complications, inpatient medical costs, and 30-day readmission rates. RESULTS: There were 99 patients in the traditional care group, and 142 in the ERAS group. The median length of stay (LOS) was 5 days in the ERAS group compared with 7 days in the traditional group (P < 0.001). The reduction in LOS was significant for both open procedures (median 6 vs 7 days, P = 0.01), and laparoscopic procedures (4 vs 6 days, P < 0.0001). ERAS patients had fewer urinary tract infections (13% vs 24%, P = 0.03). Readmission rates were lower in ERAS patients (9.8% vs 20.2%, P = 0.02). DISCUSSION: Implementation of an enhanced recovery protocol for colorectal surgery at a tertiary medical center was associated with a significantly reduced LOS and incidence of urinary tract infection. This is consistent with that of other studies in the literature and suggests that enhanced recovery programs could be implemented successfully and should be considered in U.S. hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist. Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter. Methods. This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD) on computed tomography (CT) to determine loss of resistance depth acquired during epidural placement. Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging. Results. There was a strong association between CT measurement and loss of resistance depth (P < 0.0001); the presence of morbid obesity (BMI > 35) changed this relationship (P = 0.007). The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs > 0.9). Conclusions. Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter. Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuromyelitis optica (NMO), or Devic's disease, is an idiopathic severe demyelinating disease that preferentially affects the optic nerve and spinal cord. Neuraxial anesthesia in women with multiple sclerosis is widely accepted, but reports of the use of neuraxial anesthesia in patients with NMO are scarce. We report the case of a morbidly obese primigravida undergoing a planned cesarean delivery at 32 weeks' gestation due to an acute exacerbation of NMO, managed with spinal anesthesia. Other than increased intraoperative hyperalgesia requiring inhaled nitrous oxide/oxygen, the mother experienced no apparent anesthetic-related complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ritonavir inhibition of cytochrome P450 3A4 decreases the elimination clearance of fentanyl by 67%. We used a pharmacokinetic model developed from published data to simulate the effect of sample patient-controlled epidural labor analgesic regimens on plasma fentanyl concentrations in the absence and presence of ritonavir-induced cytochrome P450 3A4 inhibition. METHODS: Fentanyl absorption from the epidural space was modeled using tanks-in-series delay elements. Systemic fentanyl disposition was described using a three-compartment pharmacokinetic model. Parameters for epidural drug absorption were estimated by fitting the model to reported plasma fentanyl concentrations measured after epidural administration. The validity of the model was assessed by comparing predicted plasma concentrations after epidural administration to published data. The effect of ritonavir was modeled as a 67% decrease in fentanyl elimination clearance. Plasma fentanyl concentrations were simulated for six sample patient-controlled epidural labor analgesic regimens over 24 h using ritonavir and control models. Simulated data were analyzed to determine if plasma fentanyl concentrations producing a 50% decrease in minute ventilation (6.1 ng/mL) were achieved. RESULTS: Simulated plasma fentanyl concentrations in the ritonavir group were higher than those in the control group for all sample labor analgesic regimens. Maximum plasma fentanyl concentrations were 1.8 ng/mL and 3.4 ng/mL for the normal and ritonavir simulations, respectively, and did not reach concentrations associated with 50% decrease in minute ventilation. CONCLUSION: Our model predicts that even with maximal clinical dosing regimens of epidural fentanyl over 24 h, ritonavir-induced cytochrome P450 3A4 inhibition is unlikely to produce plasma fentanyl concentrations associated with a decrease in minute ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We previously reported models that characterized the synergistic interaction between remifentanil and sevoflurane in blunting responses to verbal and painful stimuli. This preliminary study evaluated the ability of these models to predict a return of responsiveness during emergence from anesthesia and a response to tibial pressure when patients required analgesics in the recovery room. We hypothesized that model predictions would be consistent with observed responses. We also hypothesized that under non-steady-state conditions, accounting for the lag time between sevoflurane effect-site concentration (Ce) and end-tidal (ET) concentration would improve predictions. METHODS: Twenty patients received a sevoflurane, remifentanil, and fentanyl anesthetic. Two model predictions of responsiveness were recorded at emergence: an ET-based and a Ce-based prediction. Similarly, 2 predictions of a response to noxious stimuli were recorded when patients first required analgesics in the recovery room. Model predictions were compared with observations with graphical and temporal analyses. RESULTS: While patients were anesthetized, model predictions indicated a high likelihood that patients would be unresponsive (> or = 99%). However, after termination of the anesthetic, models exhibited a wide range of predictions at emergence (1%-97%). Although wide, the Ce-based predictions of responsiveness were better distributed over a percentage ranking of observations than the ET-based predictions. For the ET-based model, 45% of the patients awoke within 2 min of the 50% model predicted probability of unresponsiveness and 65% awoke within 4 min. For the Ce-based model, 45% of the patients awoke within 1 min of the 50% model predicted probability of unresponsiveness and 85% awoke within 3.2 min. Predictions of a response to a painful stimulus in the recovery room were similar for the Ce- and ET-based models. DISCUSSION: Results confirmed, in part, our study hypothesis; accounting for the lag time between Ce and ET sevoflurane concentrations improved model predictions of responsiveness but had no effect on predicting a response to a noxious stimulus in the recovery room. These models may be useful in predicting events of clinical interest but large-scale evaluations with numerous patients are needed to better characterize model performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anesthesia providers in low-income countries may infrequently provide regional anesthesia techniques for obstetrics due to insufficient training and supplies, limited manpower, and a lack of perceived need. In 2007, Kybele, Inc. began a 5-year collaboration in Ghana to improve obstetric anesthesia services. A program was designed to teach spinal anesthesia for cesarean delivery and spinal labor analgesia at Ridge Regional Hospital, Accra, the second largest obstetric unit in Ghana. The use of spinal anesthesia for cesarean delivery increased significantly from 6% in 2006 to 89% in 2009. By 2012, >90% of cesarean deliveries were conducted with spinal anesthesia, despite a doubling of the number performed. A trial of spinal labor analgesia was assessed in a small cohort of parturients with minimal complications; however, protocol deviations were observed. Although subsequent efforts to provide spinal analgesia in the labor ward were hampered by anesthesia provider shortages, spinal anesthesia for cesarean delivery proved to be practical and sustainable.

Relevância:

20.00% 20.00%

Publicador: