975 resultados para enzyme-linked immunosorbent assay (ELISA)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enzyme-linked immunosorbent assays (ELISAs) are the most extensively studied types of immunoassay and their application in pesticide residue monitoring is an area with enormous potential for growth. In comparison with classical analytical methods, ELISA methods offer the possibility of highly sensitive, relatively rapid, and cost-effective measurements. This review introduces the general ELISA formats used, focusing on their use in pesticide analysis. Identifying and studying the effects of interferences in immunoassays is an active area of research and we discuss the matrix effects observed in several studies involving e.g. food, crop and environmental samples. The procedures to eliminate the matrix interferences are briefly discussed. (C) 1998 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An available enzyme-linked immunosorbent assay (ELISA) was studied for the detection of anti-Dioctophyma renale antibodies in the sera of dogs using, detection of parasite eggs in urine sediment as a reference test. ELISA uses a soluble antigenic preparation of esophagus of D. renale and the optimal dilutions of the antigen, serum and conjugate were determined by means of checker board titration, using positive (n=13) and negative (n=27) reference serum. The specificity and sensitivity of the ELISA were 93.8% and 92.3% respectively and the kappa index was good (0.76). These results suggest that ELISA described may prove to be an effective serological test for detecting dogs infected and exposed to this parasite mainly dogs that are not eliminating parasite eggs through their urine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this work were to determine the prevalence of Babesia bovis, Babesia bigemina, and Anaplasma marginale detecting antibodies in cattle raised in the semi-arid region of the state of Bahia, Brazil, through indirect enzyme linked immunosorbent assays (ELISA) and to compare the performances of indirect enzyme-linked immunosorbent assays with crude (I-ELISA-CrAnaAg) and recombinant major surface protein-5 (I-ELISA-MSP-5Ag), as antigens to detect antibodies against A. marginale. An stable enzootic area was found in Senhor do Bonfim and Euclides da Cunha for B. bovis that showed 86 and 95.5% of prevalence, respectively, and for B. bigemina with 90.8 and 91.3%. On the other hand, Uauá and Juazeiro, were characterized as enzootically unstable areas, since prevalences were: B. bovis - 63.7 and 56.4% and B. bigemina - 53 and 54.8%, respectively. The prevalence of A. marginale in the four municipalities was above 97% with I-ELISA-CrAnaAg and 94.8% with I-ELISA-MSP-5Ag which is an indication of stable enzootic condition for the rickettsia. The I-ELISA-CrAnaAg and I-ELISA-MSP-5Ag showed a highly significant association (r = 0.977), which means that both ELISA tests are suitable for epidemiological studies of A. marginale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the development of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) for the rapid detection of serum antibodies to West Nile virus (WNV) in taxonomically diverse North American avian species. A panel of flavivirus-specific monoclonal antibodies (MAbs) was tested in blocking assays with serum samples from WNV-infected chickens and crows. Selected MAbs were further tested against serum samples from birds that represented 16 species and 10 families. Serum samples were collected from birds infected with WW or Saint Louis encephalitis virus (SLEV) and from noninfected control birds. Serum samples from SLEV-infected birds were included in these experiments because WNV and SLEV are closely related antigenically, are maintained in similar transmission cycles, and have overlapping geographic distributions. The ELISA that utilized MAb 3.11126 potentially discriminated between WW and SLEV infections, as all serum samples from WNV-infected birds and none from SLEV-infected birds were positive in this assay. Assays with MAbs 2132 and 6B6C-1 readily detected serum antibodies in all birds infected with WNV and SLEV, respectively, and in most birds infected with the other virus. Two other MAbs partially discriminated between infections with these two viruses. Serum samples from most WNV-infected birds but no SLEV-infected birds were positive with MAb 3.676, while almost all serum samples from SLEV-infected birds but few from WNV-infected birds were positive with MAb 6B5A-5. The blocking assays reported here provide a rapid, reliable, and inexpensive diagnostic and surveillance technique to monitor WNV activity in multiple avian species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Leptospirosis is a zoonosis of multisystem involvement caused by pathogenic strains of the genus Leptospira. In the last few years, intensive studies aimed at the development of a vaccine have provided important knowledge about the nature of the immunological mechanisms of the host. The purpose of this study was to analyze the immune responses to two recombinant proteins, MPL17 and MPL21 (encoded by the genes LIC10765 and LIC13131, respectively) of Leptospira interrogans serovar Copenhageni in individuals during infection. The recombinant proteins were expressed in Escherichia coli as six-His tag fusion proteins and were purified from the soluble bacterial fraction by affinity chromatography with Ni2+ -charged resin. The recombinant proteins were used to evaluate their ability to bind to immunoglobulin G (IgG) (and IgG subclass) or IgM antibodies in serum samples from patients in the early and convalescent phases of leptospirosis (n = 52) by enzyme-linked immunosorbent assays. The prevalences of total IgG antibodies against MPL17 and MPL21 were 38.5% and 21.2%, respectively. The titers achieved with MPL17 were statistically significantly higher than those obtained by the reference microscopic agglutination test. The specificity of the assay was estimated to be 95.5% for MPL17 and 80.6% for MPL21 when serum samples from individuals with unrelated febrile diseases and control healthy donors were tested. The proteins are conserved among Leptospira strains that cause human and animal diseases. MPL17 and MPL21 are most likely new surface proteins of leptospires, as revealed by liquid-phase immunofluorescence assays with living organisms. Our results demonstrate that these recombinant proteins are highly immunogenic and, when they are used together, might be useful as a means of diagnosing leptospirosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, nine organic sediment samples from a medieval archaeological site at Pineuilh, France, were examined for Giardia intestinalis using two commercially available immunological kits [enzyme-linked immuno sorbent and immunofluorescence (IFA) assays]. Both techniques detected G. intestinalis in one sample, dated to 1,000 Anno Domini. This is the first time IFA was successfully used to detect protozoa in Old World archaeological samples. Such immunological techniques offer important perspectives concerning ancient protozoa detection and identification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The serological detection of antibodies against human papillomavirus (HPV) antigens is a useful tool to determine exposure to genital HPV infection and in predicting the risk of infection persistence and associated lesions. Enzyme-linked immunosorbent assays (ELISAs) are commonly used for seroepidemiological studies of HPV infection but are not standardized. Intra-and interassay performance variation is difficult to control, especially in cohort studies that require the testing of specimens over extended periods. We propose the use of normalized absorbance ratios (NARs) as a standardization procedure to control for such variations and minimize measurement error. We compared NAR and ELISA optical density (OD) values for the strength of the correlation between serological results for paired visits 4 months apart and HPV-16 DNA positivity in cervical specimens from a cohort investigation of 2,048 women tested with an ELISA using HPV-16 virus-like particles. NARs were calculated by dividing the mean blank-subtracted (net) ODs by the equivalent values of a control serum pool included in the same plate in triplicate, using different dilutions. Stronger correlations were observed with NAR values than with net ODs at every dilution, with an overall reduction in nonexplained regression variability of 39%. Using logistic regression, the ranges of odds ratios of HPV-16 DNA positivity contrasting upper and lower quintiles at different dilutions and their averages were 4.73 to 5.47 for NARs and 2.78 to 3.28 for net ODs, with corresponding significant improvements in seroreactivity-risk trends across quintiles when NARs were used. The NAR standardization is a simple procedure to reduce measurement error in seroepidemiological studies of HPV infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In contrast to RIA, recently available ELISAs provide the potential for fully automated analysis of adiponectin. To date, studies reporting on the diagnostic characteristics of ELISAs and investigating on the relationship between ELISA- and RIA-based methods are rare. METHODS: Thus, we established and evaluated a fully automated platform (BEP 2000; Dade-Behring, Switzerland) for determination of adiponectin levels in serum by two different ELISA methods (competitive human adiponectin ELISA; high sensitivity human adiponectin sandwich ELISA; both Biovendor, Czech Republic). Further, as a reference method, we also employed a human adiponectin RIA (Linco Research, USA). Samples from 150 patients routinely presenting to our cardiology unit were tested. RESULTS: ELISA measurements could be accomplished in less than 3 h, measurement of RIA had a duration of 24 h. The ELISAs were evaluated for precision, analytical sensitivity and specificity, linearity on dilution and spiking recovery. In the investigated patients, type 2 diabetes, higher age and male gender were significantly associated with lower serum adiponectin concentrations. Correlations between the ELISA methods and the RIA were strong (competitive ELISA, r=0.82; sandwich ELISA, r=0.92; both p<0.001). However, Deming regression and Bland-Altman analysis indicated lack of agreement of the 3 methods preventing direct comparison of results. The equations of the regression lines are: Competitive ELISA=1.48 x RIA-0.88; High sensitivity sandwich ELISA=0.77 x RIA+1.01. CONCLUSIONS: Fully automated measurement of adiponectin by ELISA is feasible and substantially more rapid than RIA. The investigated ELISA test systems seem to exhibit analytical characteristics allowing for clinical application. In addition, there is a strong correlation between the ELISA methods and RIA. These findings might promote a more widespread use of adiponectin measurements in clinical research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With a view toward investigating the feeding behavior of Culicidae mosquitoes from an area of epizootic yellow fever transmission in the municipalities of Garruchos and Santo Antônio das Missões, Rio Grande do Sul State, Brazil, specimens were collected by aspiration from September 2005 to April 2007. The engorged females were submitted to blood meal identification by enzyme-linked immunosorbent assay (ELISA). A total of 142 blood-engorged samples were examined for human or monkey blood through species-specific IgG. Additional tests for specificity utilizing isotypes IgG1 and IgG4 of human monoclonal antibodies showed that only anti-human IgG1 was effective in recognizing blood meals of human origin. The results indicated a significant difference (p = 0.027) in detection patterns in samples of Haemagogus leucocelaenus recorded from human blood meals at Santo Antônio das Missões, which suggests some degree of exposure, since it was an area where epizootic outbreaks have been reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study compared an enzyme-linked immunosorbent assay (ELISA) to a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for measurement of tacrolimus concentrations in adult kidney and liver transplant recipients, and investigated how assay choice influenced pharmacokinetic parameter estimates and drug dosage decisions. Tacrolimus concentrations measured by both ELISA and LC/MS/MS from 29 kidney (n = 98 samples) and 27 liver (n = 97 samples) transplant recipients were used to evaluate the performance of these methods in the clinical setting. Tacrolimus concentrations measured by the two techniques were compared via regression analysis. Population pharmacokinetic models were developed independently using ELISA and LC/MS/MS data from 76 kidney recipients. Derived kinetic parameters were used to formulate typical dosing regimens for concentration targeting. Dosage recommendations for the two assays were compared. The relation between LC/MS/MS and ELISA measurements was best described by the regression equation ELISA = 1.02 . (LC/MS/MS) + 0.14 in kidney recipients, and ELISA = 1.12 . (LC/MS/MS) - 0.87 in liver recipients. ELISA displayed less accuracy than LC/MS/MS at lower tacrolimus concentrations. Population pharmacokinetic models based on ELISA and LC/MS/MS data were similar with residual random errors of 4.1 ng/mL and 3.7 ng/mL, respectively. Assay choice gave rise to dosage prediction differences ranging from 0% to 30%. ELISA measurements of tacrolimus are not automatically interchangeable with LC/MS/MS values. Assay differences were greatest in adult liver recipients, probably reflecting periods of liver dysfunction and impaired biliary secretion of metabolites. While the majority of data collected in this study suggested assay differences in adult kidney recipients were minimal, findings of ELISA dosage underpredictions of up to 25% in the long term must be investigated further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the ability of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) to detect West Nile virus (WNV) antibodies in domestic mammals. Sera were collected from experimentally infected horses, cats, and pigs at regular intervals and screened in ELISAs and plaque reduction neutralization tests. The diagnostic efficacies of these techniques were similar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydatid disease in tropical areas poses a serious diagnostic problem due to the high frequence of cross-reactivity with other endemic helminthic infections. The enzyme-linked-immunosorbent assay (ELISA) and the double diffusion arc 5 showed respectively a sensitivity of 73% and 57% and a specificity of 84-95% and 100%. However, the specificity of ELISA was greatly increased by using ovine serum and phosphorylcholine in the diluent buffer. The hydatic antigen obtained from ovine cyst fluid showed three main protein bands of 64,58 and 30 KDa using SDS PAGE and immunoblotting. Sera from patients with onchocerciasis, cysticercosis, toxocariasis and Strongyloides infection cross-reacted with the 64 and 58 KDa bands by immunoblotting. However, none of the analyzed sera recognized the 30 KDa band, that seems to be specific in this assay. The immunoblotting showed a sensitivity of 80% and a specificity of 100% when used to recognize the 30 KDa band.