963 resultados para distal radial epiphyseal closure
Resumo:
Objective: To develop a new endoscopic approach to the correction of a myelomeningocele-like defect in fetal sheep. Methods: The fetuses of 9 pregnant ewes, with an average gestational age of 115 days, were subjected to a 3.0 x 2.0 cm removal of the skin over the lumbar spine, performed through hysterotomy. The uterus was closed, and three 5-mm endoscopic cannulas, without valve mechanisms, were inserted. In the pilot phase (2 animals), we initially worked exclusively in the amniotic fluid space. In the study phase, we partially withdrew the fetus from the amniotic fluid to completely expose its back. By simply allowing air to enter the amniotic cavity (without gas injection), a working space was created using a uterine lift device. The skin around the defect was dissected, and a biosynthetic cellulose material was applied to cover the area. A continuous suture of the skin was performed to completely hide the material. Results: The combined air/fluid space allowed the skin to be successfully closed in 6 out of 7 cases in the study phase. All fetuses were alive at the end of the procedures. Time to complete the endoscopic part of the procedure fell from 3 to 1 h by the end of this series. Premature birth occurred in 2 of the 4 cases allowed to continue with the pregnancy. Conclusion: A new gasless fetoscopic surgery technique was developed as an alternative to current techniques used for fetal endoscopic surgery. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
BACKGROUND: Transanal endoscopic microsurgery may represent appropriate diagnostic and therapeutic procedure in selected patients with distal rectal cancer following neoadjuvant chemoradiation. Even though this procedure has been associated with low rates of postoperative complications, patients undergoing neoadjuvant chemoradiation seem to be at increased risk for suture line dehiscence. In this setting, we compared the clinical outcomes of patients undergoing transanal endoscopic microsurgery with and without neoadjuvant chemoradiation. METHODS: Thirty-six consecutive patients were treated by transanal endoscopic microsurgery at a single institution. Twenty-three patients underwent local excision after neoadjuvant chemoradiation therapy for rectal adenocarcinoma, and 13 patients underwent local excision without any neoadjuvant treatment for benign and malignant rectal tumors. Chemoradiation therapy included 50.4 to 54Gy and 5-fluorouracil-based chemotherapy. All patients underwent transanal endoscopic microsurgery with primary closure of the rectal defect. Complications (immediate and late) and readmission rates were compared between groups. RESULTS: Overall, median hospital stay was 2 days. Immediate (30-d) complication rate was 44% for grade II/III complications. Patients undergoing neoadjuvant chemoradiation therapy were more likely to develop grade II/III immediate complications (56% vs 23%; P = .05). Overall, the 30-day readmission rate was 30%. Wound dehiscence was significantly more frequent among patients undergoing neoadjuvant chemoradiation therapy (70% vs 23%; P = .03). Patients undergoing neoadjuvant chemoradiation therapy were at significantly higher risk of requiring readmission (43% vs 7%; P = .02). CONCLUSION: Transanal local excision with the use of endoscopic microsurgical approach may result in significant postoperative morbidity, wound dehiscence, and readmission rates, in particular, because of rectal pain secondary to wound dehiscence. In this setting, the benefits of this minimally invasive approach either for diagnostic or therapeutic purposes become significantly restricted to highly selected patients that can potentially avoid a major operation but will still face a significantly morbid and painful procedure.
Resumo:
Objective: To assess the ability of a three-layer graft in the closuse of large fetal skin defects. Methods: Ovine fetuses underwent a large (4 x 3 cm) full-thickness skin defect over the lumbar region at 105 days` gestation (term = 140 days). A bilaminar artificial skin was placed over a cellulose interface to cover the defect (3-layer graft). The skin was partially reapproximated with a continuous nylon suture. Pregnancy was allowed to continue and the surgical site was submitted to histopathological analysis at different post-operative intervals. Results: Seven fetuses underwent surgery. One maternal/fetal death occurred, and the remaining 6 fetuses were analyzed. Artificial skin adherence to the wound edges was observed in cases that remained in utero for at least 15 days. Neoskin was present beneath the silicone layer of the bilaminar artificial skin. Conclusions: Our study shows that neoskin can develop in the fetus using a 3-layer graft, including epidermal growth beneath the silicone layer of the bilaminar skin graft. These findings suggest that the fetus is able to reepithelialise even large skin defects. Further experience is necessary to assess the quality of this repair.
Resumo:
Premature closure of the proximal femoral growth plate results in coxa brevis, which usually is associated with insufficiency of the hip abductors. Distal and lateral transfer of the greater trochanter sometimes is recommended to correct this problem. Most of what is known arises from studies of children and adolescents. We asked whether this procedure in adults with coxa brevis would eliminate hip abductor insufficiency and would improve their hip function based on the Harris hip score (HHS). We prospectively followed 11 patients, aged 19 to 55 years (mean, 40 years) who had distal and lateral trochanteric transfer. All patients had pain and a positive Trendelenburg test before surgery. This test was performed at the latest followup by three observers and the interobserver reliability was determined by the kappa coefficient. The HHS was obtained before surgery and at the latest followup. The minimum followup was 25 months (mean, 52 months; range, 25-77 months). Insufficiency of the hip abductors was eliminated in seven (according to two observers) and eight (according to one observer) of the 11 patients after surgery; the kappa coefficient ranged from 0.79 to 1.0. The mean HHS improved from 64 points preoperatively to 76 points at the final followup. The two patients with preexisting severe osteoarthritis of the hip had the worst final scores and persisted with a positive Trendelenburg test at the final followup. Distal and lateral transfer of the greater trochanter can eliminate insufficiency of the hip abductors and improve joint function in adult patients with coxa brevis and we believe should be considered for patients without severe osteoarthritis of the hip. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Resumo:
We assessed the repair of transverse, 3-mm wide bone gaps created at the distal radius in 28 dogs that were randomly divided into two 14-animal groups; one was the control group and the other received a daily, 20-min application of low-intensity pulsed ultrasound for 100 days. Sequential radiographs, histomorphometrics, bone fluorescent histology and bone vascularity assessments found that all animals from both groups obtained a stage of hypertrophic-type nonunion with fibrocartilage tissue formation throughout the region of osteotomy. However, treated animals exhibited areas of endochondral ossification within the fibrocartilage region. There was no difference in type of vascularity or the newly formed bone process obtained by tetracycline labeling. Application of low-intensity ultrasound was not capable of significantly changing the reparative process and it may not be sufficiently powerful to overcome a combination of local deleterious effects on bone healing, created by gapping, excessive motion and periosteal resection. (E-mail: jbvolpon@fmrp.usp.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Background. The molecular pathogenesis of different sensitivities of the renal proximal and distal tubular cell populations to ischemic injury, including ischemia-reperfusion (IR)-induced oxidative stress, is not well-defined. An in vitro model of oxidative stress was used to compare the survival of distal [Madin-Darby canine kidney (MDCK)] and proximal [human kidney-2 (HK-2)] renal tubular epithelial cells, and to analyze for links between induced cell death and expression and localization of selected members of the Bcl-2 gene family (anti-apoptotic Bcl-2 and Bcl-X-L, pro-apoptotic Bax and Bad), Methods. Cells were treated with 1 mmol/L hydrogen peroxide (H2O2) Or were grown in control medium for 24 hours. Cell death (apoptosis) was quantitated using defined morphological criteria. DNA gel electrophoresis was used for biochemical identification. Protein expression levels and cellular localization of the selected Bcl-2 family proteins were analyzed (West ern immunoblots, densitometry, immunoelectron microscopy). Results. Apoptosis was minimal in control cultures and was greatest in treated proximal cell cultures (16.93 +/- 4.18% apoptosis) compared with treated distal cell cultures (2.28 +/- 0.85% apoptosis, P < 0.001). Endogenous expression of Bcl-X-L and Bax, but not Bcl-2 or Bad, was identified in control distal cells, Bcl-X-L and Bax had nonsignificant increases (P > 0.05) in these cells. Bcl-2, Bax, and Bcl-X-L, but not Bad, were endogenously expressed in control proximal cells. Bcl-X-L was significantly decreased in treated proximal cultures (P < 0.05), with Bas and Bcl-2 having nonsignificant increases (P > 0.05). Immunoelectron microscopy localization indicated that control and treated hut surviving proximal cells had similar cytosolic and membrane localization of the Bcl-2 proteins. In comparison, surviving cells in the treated distal cultures showed translocation of Bcl-X-L from cytosol to the mitochondria after treatment with H2O2, a result that was confirmed using cell fractionation and analysis of Bcl-XL expression levels of the membrane and cytosol proteins. Bax remained distributed evenly throughout the surviving distal cells, without particular attachment to any cellular organelle. Conclusion. The results indicate that in this in vitro model, the increased survival of distal compared with proximal tubular cells after oxidative stress is best explained by the decreased expression of anti-apoptotic Bcl-X-L in proximal cells, as well as translocation of Bcl-X-L protein to mitochondria within the surviving distal cells.
Resumo:
As part of an institutional closure programme, 95 individuals with an intellectual disability were relocated to community-based group homes. Each individual was assessed 6 months prior to the relocation and then again after 1, 6, and 12 months of community living. Assessments involved ratings of adaptive and maladaptive behaviour, choice-making, and life circumstances. The group means comparing institution to community ratings showed improvements in adaptive functioning but no significant change in maladaptive behaviour. There were also improvements in life circumstances and increased opportunities for choice-making following relocation to the community. These outcomes suggest that relocation to the community was associated with a more active and normalised lifestyle than experienced in the institutional setting.
Resumo:
Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.
Resumo:
We consider the relation between the conditional moment closure (CMC) and the unsteady flamelet model (FM). The CMC equations were originally constructed as global equations, while FM was derived asymptotically for a thin reaction zone. The recent tendency is to use FM-type equations as global equations. We investigate the possible consequences and suggest a new version of FM: coordinate-invariant FM (CIFM). Unlike FM, CIFM complies with conditional properties of the exact transport equations which are used effectively in CMC. We analyse the assumptions needed to obtain another global version of FM: representative interactive flamelets (RIF), from original FM and demonstrate that, in homogeneous turbulence, one of these assumptions is equivalent to the main CMC hypothesis.