980 resultados para detection efficiency


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to assess the genetic diversity and population structure of wheat genotypes, to detect significant and stable genetic associations, as well as to evaluate the efficiency of statistical models to identify chromosome regions responsible for the expression of spike-related traits. Eight important spike characteristics were measured during five growing seasons in Serbia. A set of 30 microsatellite markers positioned near important agronomic loci was used to evaluate genetic diversity, resulting in a total of 349 alleles. The marker-trait associations were analyzed using the general linear and mixed linear models. The results obtained for number of allelic variants per locus (11.5), average polymorphic information content value (0.68), and average gene diversity (0.722) showed that the exceptional level of polymorphism in the genotypes is the main requirement for association studies. The population structure estimated by model-based clustering distributed the genotypes into six subpopulations according to log probability of data. Significant and stable associations were detected on chromosomes 1B, 2A, 2B, 2D, and 6D, which explained from 4.7 to 40.7% of total phenotypic variations. The general linear model identified a significantly larger number of marker-trait associations (192) than the mixed linear model (76). The mixed linear model identified nine markers associated to six traits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis is about detection of local image features. The research topic belongs to the wider area of object detection, which is a machine vision and pattern recognition problem where an object must be detected (located) in an image. State-of-the-art object detection methods often divide the problem into separate interest point detection and local image description steps, but in this thesis a different technique is used, leading to higher quality image features which enable more precise localization. Instead of using interest point detection the landmark positions are marked manually. Therefore, the quality of the image features is not limited by the interest point detection phase and the learning of image features is simplified. The approach combines both interest point detection and local description into one phase for detection. Computational efficiency of the descriptor is therefore important, leaving out many of the commonly used descriptors as unsuitably heavy. Multiresolution Gabor features has been the main descriptor in this thesis and improving their efficiency is a significant part. Actual image features are formed from descriptors by using a classifierwhich can then recognize similar looking patches in new images. The main classifier is based on Gaussian mixture models. Classifiers are used in one-class classifier configuration where there are only positive training samples without explicit background class. The local image feature detection method has been tested with two freely available face detection databases and a proprietary license plate database. The localization performance was very good in these experiments. Other applications applying the same under-lying techniques are also presented, including object categorization and fault detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fungus Drechslera avenae, the causal agent of Helminthosporium leaf spot on oats (Avena sativa), survives as mycelium in crop residues and in infected seeds. In trials carried out in the laboratory, ten methods were evaluated for their efficiency to detect D. avenae in oat seeds. In each experiment, groups of two or three methods were compared to a standard protocol, in which seeds were placed in Petri dishes containing the Reis selective medium and incubated at 25±2 °C for ten days. Data were submitted to analysis of variation and the means of the methods were compared using the Dunnett test at the 5% significance level. Overall, the highest levels of seed infection by D. avenae were observed on oat seeds plated in the osmotic, the oat-agar and the Reis media, or on seeds subjected to heat treatment previous to incubation in malt-agar. Therefore, these methods should be recommended for detection of D. avenae in oat seed testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Print-capture (PC) Polymerase chain reaction (PCR) was evaluated as a novel detection method of plant viruses. Tomato (Lycopersicon esculentum) plants infected with begomovirus (fam. Geminiviridae, gen. Begomovirus) and viruliferous whiteflies were used to study the efficiency of the method. Print-capturing steps were carried out using non-charged nylon membrane or filter paper as the solid support for DNA printings. Amplified DNA fragments of expected size were consistently obtained by PCR from infected plants grown in a greenhouse, after direct application of printed materials to the PCR mix. However, virus detection from a single whitefly and from field-grown tomato samples required a high temperature treatment of printed material prior to PCR amplification. Comparison of nylon membrane and filter paper as the solid support revealed the higher efficiency of the nylon membrane. The application of print-capture PCR reduces the chances of false-positive amplification by reducing manipulation steps during preparation of the target DNA. This method maintains all the advantages of PCR diagnosis, such as the high sensitivity and no requirement of radioactive reagents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The diagnosis of Mycoplasma hyopneumoniae infection is often performed through histopathology, immunohistochemistry (IHC) and polymerase chain reaction (PCR) or a combination of these techniques. PCR can be performed on samples using several conservation methods, including swabs, frozen tissue or formalin-fixed and paraffin-embedded (FFPE) tissue. However, the formalin fixation process often inhibits DNA amplification. To evaluate whether M. hyopneumoniae DNA could be recovered from FFPE tissues, 15 lungs with cranioventral consolidation lesions were collected in a slaughterhouse from swine bred in herds with respiratory disease. Bronchial swabs and fresh lung tissue were collected, and a fragment of the corresponding lung section was placed in neutral buffered formalin for 48 hours. A PCR assay was performed to compare FFPE tissue samples with samples that were only refrigerated (bronchial swabs) or frozen (tissue pieces). M. hyopneumoniae was detected by PCR in all 15 samples of the swab and frozen tissue, while it was detected in only 11 of the 15 FFPE samples. Histological features of M. hyopneumoniae infection were presented in 11 cases and 7 of these samples stained positive in IHC. Concordance between the histological features and detection results was observed in 13 of the FFPE tissue samples. PCR was the most sensitive technique. Comparison of different sample conservation methods indicated that it is possible to detect M. hyopneumoniae from FFPE tissue. It is important to conduct further research using archived material because the efficiency of PCR could be compromised under these conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Billings and Guarapiranga Reservoirs were deeply affected by environmental disturbances, which more evident consequence are the cyanobacterial blooms. Microcystins are the most common cyanotoxin in freshwaters and more than 70 types are known. Different methods for microcystins analysis in water can be used, among which ELISA and HPLC are the most frequently employed. However, less sophisticated and more economic methods can also be used. This is the case of planar chromatography (thin-layer chromatography) method previously used in cyanotoxins purification but gradually replaced by others. Posterior optimization of the microcystin chromatography conditions and because of its simplicity, rapidity, efficiency and low cost, this method is again considered an option for the analysis of microcystins and nodularins. Considering the importance of Billings and Guarapiranga Reservoirs for drinking water supplies and the few scientific data about cyanobacteria and cyanotoxins in these water bodies, the aims of this work are to analyze the biodiversity of cyanobacteria in the Billings and Guarapiranga Reservoirs and the detection of dissolved microcystins in the water. It was possible to identify 17 species of cyanobacteria, 9 of them being potentially toxic. In Billings Reservoir Microcystis aeruginosa (Kützing) Kützing and Cylindrospermopsis raciborskii (Woloszynska) Seenayya & Subba Raju are the most common species, while in Guarapiranga Reservoir only M. aeruginosa was considered as a common species. Microcystins were detected in all Billings Reservoir samples and in only one sample from Guarapiranga Reservoir.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An indirect hemagglutination test for a seroepidemiological survey of Streptococcus pyogenes infection was standardized. This is an improved modification of the indirect hemagglutination test which utilizes an unstable reagent prepared with fresh blood cells. Two types of bacterial antigens represented by extracellular products and purified streptolysin O were assayed, but only the former antigen gave good results. Pretreatment of the bacterial antigen with 0.15 M NaOH and neutralization to pH 5.5, as well as postfixation of sensitized red cells with 0.1% glutaraldehyde at 56oC for 30 min were found to be essential to give long stability to the reagent in liquid suspension, at least 9 months at 4oC. A total of 564 serum samples with high, moderate and low anti-streptolysin O antibodies as determined by the neutralization assay were studied by the indirect hemagglutination test using the new reagent. The sensitivity, specificity, efficiency, positive predictive value and negative predictive value of the test in relation to the neutralization assay were 0.950, 0.975, 0.963, 0.973, and 0.955, respectively. The kappa agreement index between the two techniques was high (0.926) and ranked as "almost perfect". Antibody levels detected by both techniques also presented a high positive correlation (rs = 0.726). Five reagent batches successively produced proved to be reproducible. Thus, the improved indirect hemagglutination test seems to be useful for public health laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to verify the efficiency of the BAX® system for the detection of Salmonella spp. in raw chicken meat. The conventional culture method (IN 62, MAP) was used as a reference method. A total of 8,813 chicken carcass samples were analyzed. In the first part of the study, 1,200 samples were analyzed using the BAX® System and the conventional culture method. In the second part, 7,613 samples were analyzed by the BAX® system, and the conventional method was used only for samples that tested positive for Salmonella spp. by the BAX® system. The sensitivity, specificity, relative accuracy, positive predictive value, and negative predictive value obtained in the first part of this study were 100%, 92.3%, 96.4%, 53.3% and 100%, respectively. The BAX® system showed no false-negative results and reduced the time to obtain presumptive positive results. It is a suitable method for use in laboratories that perform a large number of food samples analyses daily. However, the conventional method is still required to confirm the presence of Salmonella spp. in samples that test positive using the BAX® system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leveraging cloud services, companies and organizations can significantly improve their efficiency, as well as building novel business opportunities. Cloud computing offers various advantages to companies while having some risks for them too. Advantages offered by service providers are mostly about efficiency and reliability while risks of cloud computing are mostly about security problems. Problems with security of the cloud still demand significant attention in order to tackle the potential problems. Security problems in the cloud as security problems in any area of computing, can not be fully tackled. However creating novel and new solutions can be used by service providers to mitigate the potential threats to a large extent. Looking at the security problem from a very high perspective, there are two focus directions. Security problems that threaten service user’s security and privacy are at one side. On the other hand, security problems that threaten service provider’s security and privacy are on the other side. Both kinds of threats should mostly be detected and mitigated by service providers. Looking a bit closer to the problem, mitigating security problems that target providers can protect both service provider and the user. However, the focus of research community mostly is to provide solutions to protect cloud users. A significant research effort has been put in protecting cloud tenants against external attacks. However, attacks that are originated from elastic, on-demand and legitimate cloud resources should still be considered seriously. The cloud-based botnet or botcloud is one of the prevalent cases of cloud resource misuses. Unfortunately, some of the cloud’s essential characteristics enable criminals to form reliable and low cost botclouds in a short time. In this paper, we present a system that helps to detect distributed infected Virtual Machines (VMs) acting as elements of botclouds. Based on a set of botnet related system level symptoms, our system groups VMs. Grouping VMs helps to separate infected VMs from others and narrows down the target group under inspection. Our system takes advantages of Virtual Machine Introspection (VMI) and data mining techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most soybean pathogens are seed transmitted, deserving emphasis the fungus Sclerotinia sclerotiorum, which has been presenting worrying levels of field incidence in some soybean cropping areas in several Brazilian states. The objective of this study was to verify the efficiency of different methods for detecting S. sclerotiorum on soybean seeds artificially infected in the laboratory and from field production areas with a historical disease incidence. Seed samples of seven different cultivars collected from naturally infested fields, and one seed sample artificially inoculated in the laboratory were used. The following detection methods recommended in the literature were compared: Blotter test at 7 ºC, 14 ºC, and 21 ºC; Rolled Paper; and Neon-S. Results demonstrated that these methods showed no repeatability and had a low sensitivity for detecting the pathogen in seeds from areas with disease incidence. They were effective, however, for its detection on artificially inoculated seeds. In the Blotter test method at 7 ºC, there was a lower incidence of other fungi considered undesirable during seed analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The difficulty on identifying, lack of segregation systems and absence of suitable standards for coexistence of non trangenic and transgenic soybean are contributing for contaminations that occur during productive system. The objective of this study was to evaluate the efficiency of two methods for detecting mixtures of seeds genetically modified (GM) into samples of non-GM soybean, in a way that seed lots can be assessed within the standards established by seed legislation. Two sizes of soybean samples (200 and 400 seeds), cv. BRSMG 810C (non-GM) and BRSMG 850GRR (GM), were assessed with four contamination levels (addition of GM seeds, for obtaining 0.0%, 0.5%, 1.0%, and 1.5% contamination), and two detection methods: immunoassay of lateral flux (ILF) and bioassay (pre-imbibition into 0.6% herbicide solution; 25 ºC; 16 h). The bioassay is efficient in detecting presence of GM seeds in seed samples of non-GM soybean, even for contamination lower than 1.0%, provided that seeds have high physiological quality. The ILF was positive, detecting the presence of target protein in contaminated samples, indicating test effectiveness. There was significant correlation between the two detection methods (r = 0.82; p < 0.0001). Sample size did not influence efficiency of the two methods in detecting presence of GM seeds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fluid handling systems account for a significant share of the global consumption of electrical energy. They also suffer from problems, which reduce their energy efficiency and increase life-cycle costs. Detecting or predicting these problems in time can make fluid handling systems more environmentally and economically sustainable to operate. In this Master’s Thesis, significant problems in fluid systems were studied and possibilities to develop variable-speed-drive-based detection methods for them was discussed. A literature review was conducted to find significant problems occurring in fluid handling systems containing pumps, fans and compressors. To find case examples for evaluating the feasibility of variable-speed-drive-based methods, queries were sent to industrial companies. As a result of this, the possibility to detect heat exchanger fouling with a variable-speed drive was analysed with data from three industrial cases. It was found that a mass flow rate estimate, which can be generated with a variable speed drive, can be used together with temperature measurements to monitor a heat exchanger’s thermal performance. Secondly, it was found that the fouling-related increase in the pressure drop of a heat exchanger can be monitored with a variable speed drive. Lastly, for systems where the flow device is speed controlled with by a pressure measurement, it was concluded that increasing rotational speed can be interpreted as progressing fouling in the heat exchanger.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On average approximately 13% of the water that is withdrawn by Canadian municipal water suppliers is lost before it reaches final users. This is an important topic for several reasons: water losses cost money, losses force water agencies to draw more water from lakes and streams thereby putting more stress on aquatic ecosystems, leaks reduce system reliability, leaks may contribute to future pipe failures, and leaks may allow contaminants to enter water systems thereby reducing water quality and threatening the health of water users. Some benefits of leak detection fall outside water agencies’ accounting purview (e.g. reduced health risks to households connected to public water supply systems) and, as a result, may not be considered adequately in water agency decision-making. Because of the regulatory environment in which Canadian water agencies operate, some of these benefits-especially those external to the agency or those that may accrue to the agency in future time periods- may not be fully counted when agencies decide on leak detection efforts. Our analysis suggests potential reforms to promote increased efforts for leak detection: adoption of a Canada-wide goal of universal water metering; development of full-cost accounting and, pricing for water supplies; and co-operation amongst the provinces to promulgate standards for leak detection efforts and provide incentives to promote improved efficiency and rational investment decision-making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of microcalcifications in mammograms can be considered as an early indication of breast cancer. A fastfractal block coding method to model the mammograms fordetecting the presence of microcalcifications is presented in this paper. The conventional fractal image coding method takes enormous amount of time during the fractal block encoding.procedure. In the proposed method, the image is divided intoshade and non shade blocks based on the dynamic range, andonly non shade blocks are encoded using the fractal encodingtechnique. Since the number of image blocks is considerablyreduced in the matching domain search pool, a saving of97.996% of the encoding time is obtained as compared to theconventional fractal coding method, for modeling mammograms.The above developed mammograms are used for detectingmicrocalcifications and a diagnostic efficiency of 85.7% isobtained for the 28 mammograms used.