998 resultados para dental anomaly


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fujikawa's method of evaluating the anomalies is extended to the on-shell supersymmetric (SUSY) theories. The supercurrent and the superconformal current anomalies are evaluated for the Wess-Zumino model using the background-field formulation and heat-kernel regularization. We find that the regularized Jacobians for SUSY and superconformal transformations are finite. The results can be expressed in a form such that there is no supercurrent anomaly but a finite nonzero superconformal anomaly, in agreement with similar results obtained using other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tsunami waves of the Sumatra-Andaman earthquake on 26 December 2004 claimed approximately 230 000 lives and started the biggest identification operation in Interpol's history. The aim of this study was to resolve methods of the identification and results received. The viewpoint is mainly that of forensic odontology, but also includes other means of identification and results of the medico-legal examination performed in Finland. Of the 5395 victims in Thailand, approximately 2 400 were foreigners from 36 nations including 177 Finnish nationals. Additionally, a Finnish woman perished in Sri Lanka and a severely injured man after the evacuation in a hospital. The final numbers of missing persons and dead bodies registered in the Information Management Centre in Phuket,Thailand, were 3 574 ante-mortem (AM) and 3 681 post-mortem (PM) files. The number of identifications by December 2006 was 3 271 or 89% of the victims registered. Of Finnish victims, 172 have been identified in Thailand and 163 repatriated to Finland. One adult and four children are still missing. For AM data, a list of Finnish missing persons including 178 names was published on 30 December 2004. By February 2005 all useful dental AM data were available. Five persons on the list living in Finland lacked records. Based on the AM database, for the children under age 18 years (n=60) dental identification could be established for 12 (20%). The estimated number for adults (n=112) was 96 (86%). The final identification rate, based on PM examinations in Finland, was 14 (25%) for children (n= 56) and 98 (90%) for adults (n= 109). The number of Finnish victims identified by dental methods, 112 (68%), was high compared to all examined in Thailand (43%). DNA was applied for 26 Finnish children and for 6 adults, fingerprints for 24 and 7, respectively. In 12 cases two methods were applied. Every victim (n=165) underwent in Finland a medico-legal investigation including an autopsy with sampling specimens for DNA, the toxicological and histological investigation. Digital radiographs and computed tomography were taken of the whole body to verify autopsy findings and bring out changes caused by trauma, autolysis, and sampling for DNA in Thailand. Data for identification purposes were also noted. Submersion was the cause of death for 101 of 109 adults (92.7%), and trauma for 8 (7.3%). Injuries were 33 times contributing factors for submersion and 3 times for trauma-based death. Submersion was the cause of death for 51 (92.7%) children and trauma for 4 (7.3%). Injuries were in 3 cases contributing factors in submersion and once in trauma-based death. The success of the dental identification of Finnish victims is mainly based on careful registration of dental records, and on an education program from 1999 in forensic odontology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent computer simulations on zeolites Y and A have found that the diffusion coefficient and the rate of intercage diffusion exhibit, apart from a linear dependence on the reciprocal of the square of the sorbate diameter, an anomalous peak as sorbate diameter approaches the window diameter. Here we report molecular dynamics simulations of zeolite NaA incorporating framework flexibility as a function of sorbate diameter in order to verify the existence of anomalous diffusion. Results suggest persistence of anomalous diffusion or ring effect. This suggests that the anomalous behavior is a general effect characteristic of zeolites Y and A. The barrier for diffusion across the eight-ring window is seen to be negative and is found to decrease with sorbate size. The effect of sorbate on the cage motion has also been investigated. Results suggest that the window expands during intercage migration only if the sorbate size is comparable to the window diameter. Flexible cage simulations yield a higher value for the diffusion coefficient and also the rate of intercage diffusion. This increase has been shown to be due to an increase in the intercage diffusions via the centralized diffusion mode rather than the surface-mediated mode. It is shown that this increase arises from an increase in the single particle density distribution in the region near the cage center.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two distinct ferromagnetic phases are present in LaMn0.5Co0.5O3 for which the spin-only magnetic moment calculated from the high temperature dc susceptibility is found to be unusually high. Such a high moment can only be accounted for by assigning the valence state of the cations to Mn2+-Co4+. This is unrealistic as the earlier report based on X-ray absorption spectroscopy (XAS) has suggested the valence state to be mainly Mn4+-Co2+ with traces of Co3+. Also from our studies using XAS, it is found that the valence state is mainly Mn4+-Co2+. In addition, no notable difference is observed in the minor Co3+ present in both phases. Our results based on X-ray magnetic circular dichroism studies (XMCD) reveal the presence of ``distinct'' high orbital moment associated with Co2+ for both phases. Thus it is found that the distinctness of the orbital moment also plays a vital role in determining the magnetic moment and T-c of both phases of LaMn0.5Co0.5O3. By considering the orbital moment obtained from XMCD, the anomaly in the paramagnetic susceptibility is resolved and thus we are able to assign the valence state to Mn4+-Co2+ configuration. The difference in the magnitude of orbital moment in both phases is believed to be due to the crystal field effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular dynamics (MD) simulations on rigid and flexible framework models of silicalite and a rigid framework model of the aluminophosphate VPI-5 for different sorbate diameters are reported. The sorbate-host interactions are modeled in terms of simple atom-atom Lennard-Jones interactions. The results suggest that the diffusion coefficient exhibits an anomaly as gamma approaches unity. The MD results confirm the existence of a linear regime for sorbate diameters significantly smaller than the channel diameter and an anomalous regime observed for sorbate diameters comparable to the channel diameter. The power spectra obtained by Fourier transformation of the velocity autocorrelation function indicate that there is an increase in the intensity of the low-frequency component for the velocity component parallel to the direction of motion for the sorbate diameter in the anomalous regime. The present results suggest that the diffusion anomaly is observed irrespective of (1) the geometry and topology of the pore structure and (2) the nature of the host material. The results are compared with the work of Derouane and co-workers, who have suggested the existence of ''floating molecules'' on the basis of earlier theoretical and computational approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transparent glass nanocomposites in the pseudo binary system (100 - x) SrB4O7 (SBO)-x Bi2VO5.5 (BiV) (0 less than or equal to n less than or equal to 70) were prepared by the splat quenching technique. The nano-crystallization of bismuth vanadate (BiV) in 50 SBO-50 BiV (in mol%) glass composite has been demonstrated. These were characterized for their structural, thermal and dielectric properties. As-quenched composites under study have been confirmed to be amorphous by X-ray powder diffraction (XRD) studies. The glass transition temperature (T-g) and crystallization temperatures (T-er) were determined using differential thermal analyses (DTA), High resolution transmission electron microscopic (HRTEM) studies carried out on heat-treated samples reveal the presence of spherical nanosize crystallites of Bi2VO5.5 (BiV) dispersed in the glassy matrix of SrB4O7 (SSO). The dielectric constant (epsilon (r)) and the dielectric loss (D) measurements were carried out on the as-quenched and heat-treated glass nanocomposite samples in the frequency range 100 Hz-10 MHz. The as-quenched and the heat-treated at two different temperatures (720 and 820 K) samples exhibited broad dielectric anomalies in the vicinity of the ferroelectric-to-paraelectric transition temperature of the parent BiV ceramics. The Curie-Weiss law was found to be valid at a temperature above the transition temperature, establishing the diffused nature of the transition. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we have proposed an anomaly detection algorithm based on Histogram of Oriented Motion Vectors (HOMV) 1] in sparse representation framework. Usual behavior is learned at each location by sparsely representing the HOMVs over learnt normal feature bases obtained using an online dictionary learning algorithm. In the end, anomaly is detected based on the likelihood of the occurrence of sparse coefficients at that location. The proposed approach is found to be robust compared to existing methods as demonstrated in the experiments on UCSD Ped1 and UCSD Ped2 datasets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real time anomaly detection is the need of the hour for any security applications. In this article, we have proposed a real time anomaly detection for H.264 compressed video streams utilizing pre-encoded motion vectors (MVs). The proposed work is principally motivated by the observation that MVs have distinct characteristics during anomaly than usual. Our observation shows that H.264 MV magnitude and orientation contain relevant information which can be used to model the usual behavior (UB) effectively. This is subsequently extended to detect abnormality/anomaly based on the probability of occurrence of a behavior. The performance of the proposed algorithm was evaluated and bench-marked on UMN and Ped anomaly detection video datasets, with a detection rate of 70 frames per sec resulting in 90x and 250x speedup, along with on-par detection accuracy compared to the state-of-the-art algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Granular flows occur widely in nature and industry, yet a continuum description that captures their important features is yet not at hand. Recent experiments on granular materials sheared in a cylindrical Couette device revealed a puzzling anomaly, wherein all components of the stress rise nearly exponentially with depth. Here we show, using particle dynamics simulations and imaging experiments, that the stress anomaly arises from a remarkable vortex flow. For the entire range of fill heights explored, we observe a single toroidal vortex that spans the entire Couette cell and whose sense is opposite to the uppermost Taylor vortex in a fluid. We show that the vortex is driven by a combination of shear-induced dilation, a phenomenon that has no analogue in fluids, and gravity flow. Dilatancy is an important feature of granular mechanics, but not adequately incorporated in existing models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recently observed anomaly in photoelectron angular distributions (PADs), the disappearance of the main lobes of PADs which should be usually in the direction of laser polarization, is reinterpreted as a minimum of generalized Bessel functions in the laser-polarization direction with the theory of nonperturbative quantum electrodynamics. The reinterpretation has no artificial fitting parameters and explains more features of the experimentally observed PADs, in contrast to the existing interpretation in which the anomaly is interpreted as a quantum interference of angular momentum partial waves. Some hierarchy anomalies are predicted for further experimental observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p ≤ 0,05) na correlação negativa (ρ= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo in vitro foi avaliar por meio da fluorescência de Raios X, oefeito remineralizante de dois diferentes princípios bioativos contidos no Desensibilize Nano P (nanopartículas de hidroxiapatita de cálcio) e no GC Tooth Mousse (CPP-ACP,fosfopeptídios de caseína e fosfato de cálcio amorfo) assim como da saliva artificial e do fluoreto de sódio gel neutro no esmalte dental bovino submetido a desafio erosivo. Foram utilizados 20 incisivos bovinos, seccionados na linha amelo-cementária, fixados em resina epóxi e padronizados pela planificação da superfície. Foram obtidos 20 corpos de prova (CP) que foram divididos aleatoriamente em 4 grupos. Todos os dentes foram avaliadosinicialmente para a obtenção da contagem dos elementos fósforo (P), cálcio (Ca) e estrôncio (Sr) interpretados a partir de um espectro de Fluorescência de Raios X obtidos pelo Artax 800. Após uma semana da medição inicial, cada grupo de amostras foi imerso em uma solução de 10 ml de ácido cítrico a 2% (pH 2,6) por 90 minutos. Imediatamente após obtenção dos espectros dos dentes submetidos ao desafio erosivo, cada grupo recebeu seus tratamentos correspondentes. Grupo 1 (Saliva) - saliva; Grupo 2 (Flúor) - Flúor; Grupo 3 (Nano P) - Desensibilize Nano P; Grupo 4 (Recaldent) - GC Tooth Mousse. A leitura e os tratamentos eram realizados a cada sete dias sendo repetidos por de 3 semanas. Foi utilizado inicialmente o teste de Bonferroni para comparação das médias de P, Ca e Sr dentro de cada grupo, com um nível de significância de 0,05 (p=0,05), que demonstrou remineralização efetiva na terceira semana de tratamento no grupo Nano P. Posteriormente foi utilizado o teste T-Student para comparação das médias de P, Ca e Sr entre os diferentes grupos, também com um nível de significância de 0,05 (p=0,05). O grupo Nano P foi mais efetivo do que todos os outros grupos e o grupo Saliva menos efetivo que Fluor e Recaldent após três semanas de tratamento. Nestas condições expirimentais in vitro a pasta Desensibilize Nano P foi eficaz noprocesso de remineralização dental desde a primeira semana de tratamento e estável após 3 semanas de tratamento do que os tratamentos com Saliva, Flúor e GC Tooth Mousse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar in vitro por meio da Fluorescência de Raios X por Dispersão de Energia (XRF), Microdureza Vickers (MV) e Microscopia Eletrônica de Varredura (MEV) o efeito remineralizante de diferentes princípios bioativos, tais quais, nanopartículas de hidroxiapatita de cálcio (nanoHAp) associadas ou não a fluoreto, fosfopeptídeos de caseína do leite e fosfato de cálcio amorfo (CPP-ACP) associados ou não a fluoreto, fluoreto de sódio e saliva no esmalte dental bovino submetido a ciclagem des-remineralizante simulando lesão erosiva por alto desafio ácido. Foram obtidos 58 corpos de prova (CP) a partir de 58 incisivos bovinos que foram divididos aleatoriamente em 8 grupos, com 7 CP cada um e 2 CP para obtenção de imagem em MEV do esmalte hígido. Cada grupo foi denominado conforme os respectivos tratamentos a serem utilizados. Grupo 1 (G1) Controle; Grupo 2 (G2) Desensibilize Nano P experimental (nanopartículas de hidroxiapatita de cálcio); Grupo 3 (G3) Desensibilize Nano P (nanopartículas de hidroxiapatita de cálcio e flúor); Grupo4 (G4) GC Tooth Mousse (CPP-ACP, fosfopeptídios de caseína e fosfato de cálcio amorfo Recaldent ); Grupo 5 (G5) GC Tooth Mousse Plus (CPP-ACP, fosfopeptídios de caseína e fosfato de cálcio amorfo Recaldent + 900 ppm de flúor); Grupo 6 (G6) solução aquosa de fluoreto de sódio (0,05%); Grupo 7 (G7) solução aquosa de nanopartículas de hidroxiapatita de cálcio (0,375%) e Grupo 8 (G8) solução aquosa de nanopartículas de hidroxiapatita de cálcio (0,375%) + flúor (0,05%). Foram obtidos os valores de XRF e MV antes e depois do tratamento. Durante um período experimental de 10 dias, os CPs foram submetidos a um processo cíclico de des-remineralização incluindo vários ataques diários com ácido cítrico 0,05M (pH 2,3), 6 vezes de 2 minutos ao dia, bem como as aplicações das soluções teste e períodos de remineralização em saliva artificial. O tempo entre os ciclos era de 1,5 h. Foram obtidas imagens em MEV para análise da superfície após o tratamento. Através da análise estatística pelo teste t student (p = 0,05), foram encontrados os seguintes resultados: o grupo controle teve uma desmineralização considerada severa; houve aumento na contagem de P em todos os grupos que receberam tratamento, exceto o G1, igualando ou até mesmo aumentando no caso do G5, em relação a contagem inicial; houve aumento na contagem de Ca em todos os grupos que receberam tratamento, exceto no G1, igualando ou até mesmo aumentando no caso do G4, em relação a contagem inicial; houve perda de microdureza superficial em todos os grupos; o G7 teve comportamento similar ao G1 e o G3 teve comportamento inferior ao G5 em relação ao P. E todos os outros grupos tiveram comportamento superior ao controle; o G4 e o G5 tiveram um comportamento superior ao G2 em relação ao Ca. O G5 teve comportamento superior ao G3 também em relação ao Ca e todos os grupos foram superiores ao controle; o G7 teve comportamento similar ao controle em relação a microdureza superficial e todos os outros grupos foram superiores ao controle.