998 resultados para dam area


Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE 802.11 based wireless local area networks (WLANs) are being increasingly deployed for soft real-time control applications. However, they do not provide quality-ofservice (QoS) differentiation to meet the requirements of periodic real-time traffic flows, a unique feature of real-time control systems. This problem becomes evident particularly when the network is under congested conditions. Addressing this problem, a media access control (MAC) scheme, QoS-dif, is proposed in this paper to enable QoS differentiation in IEEE 802.11 networks for different types of periodic real-time traffic flows. It extends the IEEE 802.11e Enhanced Distributed Channel Access (EDCA) by introducing a QoS differentiation method to deal with different types of periodic traffic that have different QoS requirements for real-time control applications. The effectiveness of the proposed QoS-dif scheme is demonstrated through comparisons with the IEEE 802.11e EDCA mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Restoring a large-scale power system has always been a complicated and important issue. A lot of research work has been done on different aspects of the whole power system restoration procedure. However, more time will be required to complete the power system restoration process in an actual situation if accurate and real-time system data cannot be obtained. With the development of the wide area monitoring system (WAMS), power system operators are capable of accessing to more accurate data in the restoration stage after a major outage. The ultimate goal of the system restoration is to restore as much load as possible while in the shortest period of time after a blackout, and the restorable load can be estimated by employing WAMS. Moreover, discrete restorable loads are employed considering the limited number of circuit-breaker operations and the practical topology of distribution systems. In this work, a restorable load estimation method is proposed employing WAMS data after the network frame has been reenergized, and WAMS is also employed to monitor the system parameters in case the newly recovered system becomes unstable again. The proposed method has been validated with the New England 39-Bus system and an actual power system in Guangzhou, China.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a new general approach for defining coherent generators in power systems based on the coherency in low frequency inter-area modes. The disturbance is considered to be distributed in the network by applying random load changes which is the random walk representation of real loads instead of a single fault and coherent generators are obtained by spectrum analysis of the generators velocity variations. In order to find the coherent areas and their borders in the inter-connected networks, non-generating buses are assigned to each group of coherent generator using similar coherency detection techniques. The method is evaluated on two test systems and coherent generators and areas are obtained for different operating points to provide a more accurate grouping approach which is valid across a range of realistic operating points of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the decision-making of multi-area ATC (Available Transfer Capacity) in electricity market environment, the existing resources of transmission network should be optimally dispatched and coordinately employed on the premise that the secure system operation is maintained and risk associated is controllable. The non-sequential Monte Carlo simulation is used to determine the ATC probability density distribution of specified areas under the influence of several uncertainty factors, based on which, a coordinated probabilistic optimal decision-making model with the maximal risk benefit as its objective is developed for multi-area ATC. The NSGA-II is applied to calculate the ATC of each area, which considers the risk cost caused by relevant uncertainty factors and the synchronous coordination among areas. The essential characteristics of the developed model and the employed algorithm are illustrated by the example of IEEE 118-bus test system. Simulative result shows that, the risk of multi-area ATC decision-making is influenced by the uncertainties in power system operation and the relative importance degrees of different areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Several new types of contraception became available in Australia over the last twelve years (the implant in 2001, progestogen intra-uterine device (IUD) in 2003, and vaginal contraceptive ring in 2007). Most methods of contraception require access to health services. Permanent sterilisation and the insertion of an implant or IUD involve a surgical procedure. Access to health professionals providing these specialised services may be more difficult in rural areas. This paper examines uptake of permanent or long-acting reversible contraception (LARCs) among Australian women in rural areas compared to women in urban areas. Method: Participants in the Australian Longitudinal Study on Women's Health born in 1973-78 reported on their contraceptive use at three surveys: 2003, 2006 and 2009. Contraceptive methods included permanent sterilisation (tubal ligation, vasectomy), non-daily or LARC methods (implant, IUD, injection, vaginal ring), and other methods including daily, barrier or "natural" methods (oral contraceptive pills, condoms, withdrawal, safe period). Sociodemographic, reproductive history and health service use factors associated with using permanent, LARC or other methods were examined using a multivariable logistic regression analysis. Results: Of 9,081 women aged 25-30 in 2003, 3% used permanent methods and 4% used LARCs. Six years later in 2009, of 8,200 women (aged 31-36), 11% used permanent methods and 9% used LARCs. The fully adjusted parsimonious regression model showed that the likelihood of a woman using LARCs and permanent methods increased with number of children. Women whose youngest child was school-age were more likely to use LARCs (OR=1.83, 95%CI 1.43-2.33) or permanent methods (OR=4.39, 95%CI 3.54-5.46) compared to women with pre-school children. Compared to women living in major cities, women in inner regional areas were more likely to use LARCs (OR=1.26, 95%CI 1.03-1.55) or permanent methods (OR=1.43, 95%CI 1.17-1.76). Women living in outer regional and remote areas were more likely than women living in cities to use LARCs (OR=1.65, 95%CI 1.31-2.08) or permanent methods (OR=1.69, 95%CI 1.43-2.14). Women with poorer access to GPs were more likely to use permanent methods (OR=1.27, 95%CI 1.07-1.52). Conclusions: Location of residence and access to health services are important factors in women's choices about long-acting contraception in addition to the number and age of their children. There is a low level of uptake of non-daily, long-acting methods of contraception among Australian women in their mid-thirties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter contains sections titled: Introduction ICZM and sustainable development of coastal zone International legal framework for ICZM Implementation of international legal obligations in domestic arena Concluding remarks References

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis was a step forward in improving the stability of power systems by applying new control and modelling techniques. The developed methods use the data obtained from voltage angle measurement devices which are synchronized with GPS signals to stabilize the system and avoid system-wide blackouts in the event of severe faults. New approaches were developed in this research for identifying and estimating reduced dynamic system models using phasor measurement units. The main goal of this research is achieved by integrating the developed methods to obtain a feasible wide-area control system for stabilizing the power systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic goethite and thermally treated goethite at different temperatures were used to remove phosphate from sewage. The effect of annealing temperature on phosphate removal over time was investigated. X-ray diffraction(XRD), transmission electron microscopy (TEM), N2 adsorption and desorption (BET), and infrared emission spectrum (FT-IES) were utilized to characterize the phase, morphology, specific surface area, pore distribution, and the surface groups of samples. The results show that annealed products of goethite at temperatures over 250 °C are hematite with the similar morphology as the original goethite with different hydroxyl groups and surface area. Increasing temperature causes the decrease in hydroxyl groups, consequential increase in surface area at first and then experiences a decrease (14.8–110.4–12.6 m2/g) and the subsequent formation of nanoscale pores. The variation rate of hydroxyl groups and surface area based on FT-IES and BET, respectively, are used to evaluate the effect of annealing temperature on phosphate removal. By using all of the characterization techniques, it is concluded that the changes of phosphate removal basically result from the total variation rate between hydroxyl groups and surface area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two recent decisions of the Supreme Court of New South Wales in the context of obstetric management have highlighted firstly, the importance of keeping legible, accurate and detailed medical records; and secondly, the challenges faced by those seeking to establish causation, particularly where epidemiological evidence is relied upon...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surface area of inhaled particles deposited in the alveolar region, as reported by the TSI nanoparticle surface area monitor (NSAM), was compared with the corresponding value estimated by a TSI scanning mobility particle sizer (SMPS) for a range of environmentally relevant aerosols, including petrol emissions, ETS, laser printer emissions, cooking emissions and ambient aerosols. The SMPS values were based on a mobility size distribution assuming spherical particles using the appropriate size-dependent alveolar-deposition factors provided by the ICRP. In most cases, the two instruments showed good linear agreement. With petrol emissions and ETS, the linearity extended to over 103 μm2 cm-3. With printer emissions, there was good linearity up to about 300 μm2 cm-3 while the NSAM increasingly overestimated the surface area at higher concentrations. The presence of a nucleation event in ambient air caused the NSAM to over-estimate the surface area by a factor of 2. We summarize these results and conclude that the maximum number concentration up to which the NSAM is accurate clearly depends on the type of aerosol being sampled and provide guidance for the use of the instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Early childhood caries is a highly destructive dental disease which is compounded by the need for young children to be treated under general anaesthesia. In Australia, there are long waiting periods for treatment at public hospitals. In this paper, we examined the costs and patient outcomes of a prevention programme for early childhood caries to assess its value for government services. Design Cost-effectiveness analysis using a Markov model. Setting Public dental patients in a low socioeconomic, socially disadvantaged area in the State of Queensland, Australia. Participants Children aged 6 months to 6 years received either a telephone prevention programme or usual care. Primary and secondary outcome measures A mathematical model was used to assess caries incidence and public dental treatment costs for a cohort of children. Healthcare costs, treatment probabilities and caries incidence were modelled from 6 months to 6 years of age based on trial data from mothers and their children who received either a telephone prevention programme or usual care. Sensitivity analyses were used to assess the robustness of the findings to uncertainty in the model estimates. Results By age 6 years, the telephone intervention programme had prevented an estimated 43 carious teeth and saved £69 984 in healthcare costs per 100 children. The results were sensitive to the cost of general anaesthesia (cost-savings range £36 043–£97 298) and the incidence of caries in the prevention group (cost-savings range £59 496–£83 368) and usual care (cost-savings range £46 833–£93 328), but there were cost savings in all scenarios. Conclusions A telephone intervention that aims to prevent early childhood caries is likely to generate considerable and immediate patient benefits and cost savings to the public dental health service in disadvantaged communities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurately quantifying total freshwater storage methane release to atmosphere requires the spatial–temporal measurement of both diffusive and ebullitive emissions. Existing floating chamber techniques provide localised assessment of methane flux, however, significant errors can arise when weighting and extrapolation to the entire storage, particularly when ebullition is significant. An improved technique has been developed that compliments traditional chamber based experiments to quantify the storage-scale release of methane gas to atmosphere through ebullition using the measurements from an Optical Methane Detector (OMD) and a robotic boat. This provides a conservative estimate of the methane emission rate from ebullition along with the bubble volume distribution. It also georeferences the area of ebullition activity across entire storages at short temporal scales. An assessment on Little Nerang Dam in Queensland, Australia, demonstrated whole storage methane release significantly differed spatially and throughout the day. Total methane emission estimates showed a potential 32-fold variation in whole-of-dam rates depending on the measurement and extrapolation method and time of day used. The combined chamber and OMD technique showed that 1.8–7.0% of the surface area of Little Nerang Dam is accounting for up to 97% of total methane release to atmosphere throughout the day. Additionally, over 95% of detectable ebullition occurred in depths less than 12 m during the day and 6 m at night. This difference in spatial and temporal methane release rate distribution highlights the need to monitor significant regions of, if not the entire, water storage in order to provide an accurate estimate of ebullition rates and their contribution to annual methane emissions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To explore the impact of geographical remoteness and area-level socioeconomic disadvantage on colorectal cancer (CRC) survival. Methods Multilevel logistic regression and Markov chain Monte Carlo simulations were used to analyze geographical variations in five-year all-cause and CRC-specific survival across 478 regions in Queensland Australia for 22,727 CRC cases aged 20–84 years diagnosed from 1997–2007. Results Area-level disadvantage and geographic remoteness were independently associated with CRC survival. After full multivariate adjustment (both levels), patients from remote (odds Ratio [OR]: 1.24, 95%CrI: 1.07-1.42) and more disadvantaged quintiles (OR = 1.12, 1.15, 1.20, 1.23 for Quintiles 4, 3, 2 and 1 respectively) had lower CRC-specific survival than major cities and least disadvantaged areas. Similar associations were found for all-cause survival. Area disadvantage accounted for a substantial amount of the all-cause variation between areas. Conclusions We have demonstrated that the area-level inequalities in survival of colorectal cancer patients cannot be explained by the measured individual-level characteristics of the patients or their cancer and remain after adjusting for cancer stage. Further research is urgently needed to clarify the factors that underlie the survival differences, including the importance of geographical differences in clinical management of CRC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wide-Area Measurement Systems (WAMS) provide the opportunity of utilizing remote signals from different locations for the enhancement of power system stability. This paper focuses on the implementation of remote measurements as supplementary signals for off-center Static Var Compensators (SVCs) to damp inter-area oscillations. Combination of participation factor and residue method is used for the selection of most effective stabilizing signal. Speed difference of two generators from separate areas is identified as the best stabilizing signal and used as a supplementary signal for lead-lag controller of SVCs. Time delays of remote measurements and control signals is considered. Wide-Area Damping Controller (WADC) is deployed in Matlab Simulink framework and is tested under different operating conditions. Simulation results reveal that the proposed WADC improve the dynamic characteristic of the system significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective This study was to investigate issues that arose from pre-admission to post-discharge, for people in Toowoomba, Queensland over the age of 65 admitted to an acute facility. This paper concentrates on a significant concern that emerged from the large amount of data collected during this project, that is,the role of the nurse in the continuum of health care involving elderly people. Method The study involved a multi-site, multi-agency and multi-method (qualitative and quantitative) approach. Data was collected from regional service providers, the Department of Health and Aged Care (DHAC), the Australian Bureau of Statistics (ABS), Home and Community Care (HACC), the Aged Care Assessment Team (ACAT), elderly people who had been discharged from regional hospitals and their carers, residents of regional aged care facilities, area health professionals and elderly regional hospital inpatients. Results The data indicated that nurses in this provincial area currently play a limited role in preadmission planning, being mostly concerned with elective surgery, especially joint replacements. While nurses deliver the majority of care during hospitalisation, they do not appear to be cognizant of the needs of the elderly regarding post-acute discharge. Conclusion The recent introduction of the model of nurse case management in the acute sector appears to be a positive development that will streamline and optimise the health care of the elderly across the continuum in the Toowoomba area. The paper recommends some strategies, such as discharge liaison nurses based in Emergency Departments and the expansion of the nurse case management role, which would optimise care for the elderly person at the interface of care.