949 resultados para cross-curriculum testing
Resumo:
The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.
Resumo:
A numerical scheme is presented for the solution of the Euler equations of compressible flow of a gas in a single spatial co-ordinate. This includes flow in a duct of variable cross-section as well as flow with slab, cylindrical or spherical symmetry and can prove useful when testing codes for the two-dimensional equations governing compressible flow of a gas. The resulting scheme requires an average of the flow variables across the interface between cells and for computational efficiency this average is chosen to be the arithmetic mean, which is in contrast to the usual ‘square root’ averages found in this type of scheme. The scheme is applied with success to five problems with either slab or cylindrical symmetry and a comparison is made in the cylindrical case with results from a two-dimensional problem with no sources.
Resumo:
Ethnopharmacological relevance One of the major drawbacks of using ethnomedicinal data to direct testing of plants which may find pharmaceutical use is that certain plants without bioactivity might be traditionally used. An accepted way of highlighting bioactive plants is to compare usage in different cultures. This approach infers that presumed independent discovery by different cultures provides evidence for bioactivity. Although several studies have made cross-cultural comparisons, they focussed on closely related cultures, where common patterns might be the result of common cultural traditions. The aim of this study was to compare three independent ethnomedicinal floras for which similarities can be more robustly interpreted as independent discoveries, and therefore likely to be indication for efficacy. Materials and methods Data from the literature were compiled about the ethnomedicinal floras for three groups of cultures (Nepal, New Zealand and the Cape of South Africa), selected to minimise historical cultural exchange. Ethnomedicinal applications were divided in 13 categories of use. Regression and binomial analyses were performed at the family level to highlight ethnomedicinal “hot” families. General and condition-specific analyses were carried out. Results from the three regions were compared. Results Several “hot” families (Anacardiaceae, Asteraceae, Convolvulaceae, Clusiaceae, Cucurbitaceae, Euphorbiaceae, Geraniaceae, Lamiaceae, Malvaceae, Rubiaceae, Sapindaceae, Sapotaceae and Solanaceae) were recovered in common in the general analyses. Several families were also found in common under different categories of use. Conclusions Although profound differences are found in the three ethnomedicinal floras, common patterns in ethnomedicinal usage are observed in widely disparate areas of the world with substantially different cultural traditions. As these similarities are likely to stem from independent discoveries, they strongly suggest that underlying bioactivity might be the reason for this convergent usage. The global distribution of prominent usage of families used in common obtained by this study and the wider literature is strong evidence that these families display exceptional potential for discovery of previously overlooked or new medicinal plants and should be placed in high priority in bioscreening studies and conservation schemes.
Resumo:
Marketing research efforts across Eastern European countries continue growing since the introduction of market reforms in this region. Nonetheless, questions remain unanswered as to cross-cultural differences in Eastern Europeans' consumer behavior. The present research addresses this knowledge gap by developing and testing hypotheses about cross-cultural variations in a number of clothing-related consumer behavior phenomena in the Czech Republic and Bulgaria. Our findings indicate significant differences regarding consumer interest in clothing, preference for utilitarian, self-expressive and hedonic meanings of clothing artifacts, preference for well-known clothing brands, brand loyalty, and importance of clothing attributes. The study advances research in marketing by investigating clothing value-expressive symbolism and consumption in the tworecentEUMember States. The study provides valuable insights to marketers for developing effective marketing strategies.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.
Resumo:
Version 1 of the Global Charcoal Database is now available for regional fire history reconstructions, data exploration, hypothesis testing, and evaluation of coupled climate–vegetation–fire model simulations. The charcoal database contains over 400 radiocarbon-dated records that document changes in charcoal abundance during the Late Quaternary. The aim of this public database is to stimulate cross-disciplinary research in fire sciences targeted at an increased understanding of the controls and impacts of natural and anthropogenic fire regimes on centennial-to-orbital timescales. We describe here the data standardization techniques for comparing multiple types of sedimentary charcoal records. Version 1 of the Global Charcoal Database has been used to characterize global and regional patterns in fire activity since the last glacial maximum. Recent studies using the charcoal database have explored the relation between climate and fire during periods of rapid climate change, including evidence of fire activity during the Younger Dryas Chronozone, and during the past two millennia.
Resumo:
Nursing school graduates are under pressure to pass the RN-NCLEX Exam on the first attempt since New York State monitors the results and uses them to evaluate the school’s nursing programs. Since the RN-NCLEX Exam is a standardized test, we sought a method to make our students better test takers. The use of on-line computer adaptive testing has raised our student’s standardized test scores at the end of the nursing course.
Resumo:
The initial endogenous growth models emphasized the importance of externaI effects in explaining sustainable growth across time. Empirically, this hypothesis can be confirmed if the coefficient of physical capital per hour is unity in the aggregate production function. Although cross-section results concur with theory, previous estimates using time series data rejected this hypothesis, showing a small coefficient far from unity. It seems that the problem lies not with the theory but with the techniques employed, which are unable to capture low frequency movements in high frequency data. This paper uses cointegration - a technique designed to capture the existence of long-run relationships in multivariate time series - to test the externalities hypothesis of endogenous growth. The results confirm the theory' and conform to previous cross-section estimates. We show that there is long-run proportionality between output per hour and a measure of capital per hour. U sing this result, we confmn the hypothesis that the implied Solow residual can be explained by government expenditures on infra-structure, which suggests a supply side role for government affecting productivity and a decrease on the extent that the Solow residual explains the variation of output.
Resumo:
The broader objective of this study undertaking can briefly be articulated in particulate aims as follows: to measure the attitudes of consumers regarding the brand displayed by this strategy as well as to highlight recall, recognition and purchase intentions generated by product placement on consumers. In addition, check the differences and similarities between the behavior of Brazilian and American consumers caused by the influence of product placements. The study was undertaken targeting consumer audience in Brazil and the U.S. A rang3 modeling set ups were performed in order to realign study instruments and hypothesis towards the research objectives. This study gave focus on the following hypothesized models. H1: Consumers / Participants who viewed the brands / products in the movie have a higher brand / product recall compared to the consumers / participants who did not view the brands / products in the movie. H2: US Consumers / Participants are able to recognize and recall brands / products which appear in the background of the movie than Brazil. H3: Consumers / participants from USA are more accepting of product placements compared to their counterparts in Brazil. H4: There are discernible similarities in consumer / participant brand attitudes and purchase intentions in consumers / participants from USA and Brazil in spite of the fact that their country of origin is different. Cronbach’s Alpha Coefficient ensured the reliability of survey instruments. The study involved the use of the Structural Equation Modeling (SEM) for the hypothesis testing. This study used the Confirmatory Factor Analysis (CFA) to assess both the convergent and discriminant validities instead of using the Exploratory Factor Analysis (EFA) or the Principal Component Analysis (PCA). This reinforced for the use of the regression Chi Square and T statistical tests in further. Only hypothesis H3 was rejected, the rest were not. T test provided insight findings on specific subgroup significant differences. In the SEM testing, the error variance for product placement attitudes was negative for both the groups. On this The Heywood Case came in handy to fix negative values. The researcher used both quantitative and qualitative approach where closed ended questionnaires and interviews respectively were used to collect primary data. The results were additionally provided with tabulations. It can be concluded that, product placement varies markedly in the U.S. from Brazil based on the influence a range of factors provided in the study. However, there are elements of convergence probably driven by the convergence in technology. In order, product placement to become more competitive in the promotional marketing, there will be the need for researchers to extend focus from the traditional variables and add knowledge on the conventional marketplace factors that is the sell-ability of the product placement technologies and strategies.
Resumo:
Dry matter intake (DMI) of coast-cross grazing by crossbred Holstein-Zebu and Zebu lactating cows was calculated using in vitro dry matter digestibility from extrusa (four esophageal fistulated cows) and fecal output estimate with mordent chromium. Pasture was rotationally grazed with three days grazing period and 27 days testing period, adopting a stocking rate of 1.6 and 3.2 cows/ha, during the dry and rainy season respectively. Voluntary DMI was estimated from degradation characteristics using different equations. Predicted coast-cross DMI varied with models. The prediction of tropical forages dry matter intake from equations based in ruminal degradation parameters needs farther investigation before being employed in practice.
Resumo:
Objectives. This study compared the shear bond strength (SBS) and microtensile (MTBS) testing methodologies for core and veneering ceramics in four types of all-ceramic systems.Methods. Four different ceramic veneer/core combinations, three of which were feldspathic and the other a fluor-apatite to their respectively corresponding cores, namely leucitereinforced ceramic ((IPS)Empress, Ivoclar), low leucite-reinforced ceramic (Finesse, Ceramco), glass-infiltrated alumina (In-Ceram Alumina, Vita) and lithium disilicate ((IPS)Empress 2, Ivoclar) were used for SBS and MTBS tests. Ceramic cores (N = 40, n = 10/group for SBS test method, N=5blocks/group for MTBS test method) were fabricated according to the manufacturers' instructions (for SBS: thickness, 3 mm; diameter, 5 mm and for MTBS: 10 mm x 10 mm x 2 mm) and ultrasonically cleaned. The veneering ceramics (thickness: 2 mm) were vibrated and condensed in stainless steel moulds and fired onto the core ceramic materials. After trying the specimens in the mould for minor adjustments, they were again ultrasonically cleaned and embedded in PMMA. The specimens were stored in distilled water at 37 degrees C for 1 week and bond strength tests were performed in universal testing machines (cross-head speed: 1mm/min). The bond strengths (MPa +/- S.D.) and modes of failures were recorded.Results. Significant difference between the two test methods and all-ceramic types were observed (P < 0.05) (2-way ANOVA, Tukey's test and Bonferroni). The mean SBS values for veneering ceramic to lithium disilicate was significantly higher (41 +/- 8 MPa) than those to low leucite (28 +/- 4 MPa), glass-infiltrated (26 +/- 4 MPa) and leucite-reinforced (23 +/- 3 MPa) ceramics, while the mean MTBS for low leucite ceramic was significantly higher (15 +/- 2 MPa) than those of leucite (12 +/- 2 MPa), glass-infiltrated (9 +/- 1 MPa) and lithium disilicate ceramic (9 +/- 1 MPa) (ANOVA, P < 0.05).Significance. Both the testing methodology and the differences in chemical compositions of the core and veneering ceramics influenced the bond strength between the core and veneering ceramic in bilayered all-ceramic systems. (c) 2006 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: To evaluate the influence of different cross-head speeds on shear bond strength test on the dentin surface.Methods: One hundred and twenty extracted bovine incisors were embedded in polystyrene resin. The specimens were prepared by wet grinding with 320-, 400- and 600-grit Al2O3 paper exposing dentin. After the application of the adhesive system Single Bond (3M) to etched dentin, the composite resin Z-100 (3M) was applied and light cured. The specimens were randomly assigned to four groups (n = 30). The shear bond strength tests were performed with an EMIC DL 500 universal testing machine at four different cross-head speeds: 0.50 (A); 0.75 (B); 1.00 (C); and 5.00 mm/min (D).Results: the mean values of shear bond strength in MPa (SD) were: A, 11.78 (3.91); B, 11.82 (4.78); C, 16.32 (6.45); D, 15.46 (5.94). The data were analyzed with one-way ANOVA and Tukey's test (alpha = 0.05). The results indicated that A = B < C = D. The fracture pattern was evaluated by visual analysis in a stereomicroscope (25 x). The percentage of fractures that occurred at the adhesive interface were: A, 92.5%; B, 91.6%; C, 70.0%; D, 47.0%. The Student's t-test to percentages (
Resumo:
This paper presents a new non-destructive testing (NDT) for reinforced concrete structures, in order to identify the components of their reinforcement. A time varying electromagnetic field is generated close to the structure by electromagnetic devices specially designed for this purpose. The presence of ferromagnetic materials (the steel bars of the reinforcement) immersed in the concrete disturbs the magnetic field at the surface of the structure. These field alterations are detected by sensors coils placed on the concrete surface. Variations in position and cross section (the size) of steel bars immersed in concrete originate slightly different values for the induced voltages at the coils.. The values for the induced voltages were obtained in laboratory tests, and multi-layer perceptron artificial neural networks with Levemberg-Marquardt training algorithm were used to identify the location and size of the bar. Preliminary results can be considered very good.
Resumo:
A large portion of Brazil is covered with tropical soils but literature about dynamic parameters of these soils is very limited. SCPT and cross-hole tests were carried out at an experimental research site inland in the state of São Paulo, Brazil. Shear wave velocities (VS) determined based on both tests are presented and compared. A good agreement was observed between both test results and the differences can be associated with soil variability, which was very sensitive to CPT tests. It was also observed that Go/q c ratio determined based on SCPT appears to be an interesting technique to help identify tropical soils. Copyright ASCE 2006.
Resumo:
This paper presents a system for performing down-hole seismic test together with the piezocone test in order to determine the shear wave velocity (Vs) and for calculating the maximum shear modulus (Go); a basic parameter for analyzing the dynamic soil behavior and a reference value of the soil stiffness. The system components are described and tests results for checking the geophone response are also presented, both before and after installation into the probe. The system was used in down-hole tests carried out at three experimental research sites located in the interior of Sao Paulo State, Brazil, where in situ seismic test results are available. The Vs values measured in down-hole tests carried out with this system were consistent with those determined in cross-hole tests and with a commercial seismic piezocone, which enabled to validate the developed system.