729 resultados para contact tip
Resumo:
Reports on airborne dermatoses are mainly published in the context of occupational settings. Hence, in recent years, dermatologists and also occupational physicians have become increasingly aware of the airborne source of contact dermatitis, resulting mainly from exposure to irritants or allergens. However, their occurrence is still underestimated, because reports often omit the term 'airborne' in relation to dust or volatile allergens. For the present update, we screened the journals 'Contact Dermatitis' (July 2000 to December 2006); 'Dermatitis', formerly named 'American Journal of Contact Dermatitis'; 'La Lettre du Gerda' (January 2000 to December 2006); and also included relevant articles from other journals published during the same period. This resulted in an updated list of airborne dermatitis causes.
Resumo:
Rodents are the most frequently used animals in surgical experimentation. It is estimated that guinea pigs in particular are the third most commonly used species in this context. To disinfect guinea pigs’ skin, either alcohol or surgical iodine are most often used. In the context of an animal research project, a Nissen operation was performed in an adult male guinea pig. Because of accidental contamination of the operative field, a 10% povidone-iodine cutaneous solution was applied to the serosa of the anterior wall of the stomach and to the gastric fundus. The guinea pig died 12 hours after surgery due to an acute necrotizing hemorrhagic gastritis. Although there have been a few reports of povidone-iodine toxicity in the guinea pig, as far as the authors could determine, this is the first time that such a serious abdominal complication is reported. The authors believe that the possibility of a similar event should be taken into consideration when planning, executing and interpreting experiments in the guinea pig.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Field lab: Consulting lab
Resumo:
Venomous animals are those that, by means of a hunting and defense mechanism, are able to inject their prey with a toxic substance produced in their bodies, directly from specialized glands (e.g., tooth, sting, spur) through which the poison passes. Millipedes are poisonous animals; they can be harmful to humans, and their effects usually manifest as erythematous, purpuric, and cyanotic lesions; local pain; and paresthesia. Here, we report a case of skin contact with a millipede for 6h resulting in skin lesions similar to blue toe syndrome.
Resumo:
This research intends to examine if there were significant differences on the brand engagement and on the electronic word of mouth (e-WOM)1 referral intention through Facebook between Generation X and Generation Y (also called millennials). Also, this study intends to examine if there are differences in the motivations that drive these generations to interact with brands through Facebook. Results indicated that Generation Y members consumed more content on Facebook brands’ pages than Generation X. Also, they were more likely to have an e-WOM referral intention as well as being more driven by brand affiliation and opportunity seeking. Finally, currently employed individuals were found to contribute with more content than students. This study fills the gap in the literature by addressing how marketing professionals should market their brand and interact and engage with their customers, based on customers’ generational cohort.
Resumo:
This project aims to provide feasible solutions to improve customer´s Help Area at Continente Online. The goal is to increase satisfaction and loyalty by reducing the main causes that lead customers to appeal to Call Center or abandon the website. The pursued solution is the implementation of Web Self-Service and the vision taken is focused not only on providing customers basic help tools but also innovate with international best practices to sustain Sonae MC´s present and future market leader position. Customer´s feedback, costs and impact are taken in consideration to find the best fit for the company.
Resumo:
This study aimed to understand employees’ reactions to organizational politics in Contact Centers. Drawing from a sample of 187 supervisor-employee dyads, we studied the relationship between employees’ perceptions of organizational politics and supervisor-rated task performance and deviance, and mediation effects by authenticity at work and affective commitment. Results indicate that workers tend to react to workplace politics with deviant behavior and worse task performance. We found that the relationship between perceived politics and task performance was mediated by authenticity. The relationship between perceived politics and supervisor-rated deviance was mediated by affective commitment to the organization. Implications for management are discussed.
Resumo:
Purpose: To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. Methods: Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-touch or three-pointtouch fitting approach. The lens’ back optic zone radius (BOZR) was 0.4 mm and 0.1 mm flatter than the first definite apical clearance lens, respectively. Differences between the baseline and post-CL wear for steepest, flattest and average corneal power (ACP) readings, central corneal astigmatism (CCA), maximum tangential curvature (KTag), anterior corneal surface asphericity, anterior corneal surface HOA and thinnest corneal thickness measured with Pentacam were compared. Results: A statistically significant flattening was found over time on the flattest and steepest simulated keratometry and ACP in apical-touch group (all p < 0.01). A statistically significant reduction in KTag was found in both groups after contact lens wear (all p < 0.05). Significant reduction was found over time in CCA (p = 0.001) and anterior corneal asphericity in both groups (p < 0.001). Thickness at the thinnest corneal point increased significantly after CL wear (p < 0.0001). Coma-like and total HOA root mean square (RMS) error were significantly reduced following CL wearing in both fitting approaches (all p < 0.05). Conclusion: Short-term rigid gas-permeable CL wear flattens the anterior cornea, increases the thinnest corneal thickness and reduces anterior surface HOA in keratoconus subjects. Apicaltouch was associated with greater corneal flattening in comparison to three-point-touch lens wear.
Resumo:
Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
Resumo:
Purpose: To study the relationship among the variables intensity ofthe end-of-day (EOD) dryness, corneal sensitivity and blink rate in soft contact lens (CL) wearers. Methods: Thirty-eight soft CL wearers (25 women and 13 men; mean age 27.1 ± 7.2 years) were enrolled. EOD dryness was assessed using a scale of 0–5 (0, none to 5, very intense). Mechanical and thermal (heat and cold) sensitivity were measured using a Belmonte’s gas esthesiometer. The blink rate was recorded using a video camera while subjects were wearing a hydrogel CL and watching a film for 90 min in a controlled environmental chamber. Results: A significant inverse correlation was found between EOD dryness and mechanical sensitivity (r: −0.39; p = 0.02); however, there were no significant correlations between EOD dryness and thermal sensitivity. A significant (r: 0.56; p < 0.001) correlation also was observed between EOD dryness and blink rate, but no correlations were found between blink rate and mechanical or thermal sensitivity. Conclusions: CL wearers with higher corneal sensitivity to mechanical stimulation reported more EOD dryness with habitual CL wear. Moreover, subjects reporting more EOD dryness had an increased blink rates during wear of a standard CL type. The increased blink rate could act to improve the ocular surface environment and relieve symptoms
Resumo:
Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.