875 resultados para cold smoking
Numerical and experimental studies of cold-formed steel floor systems under standard fire conditions
Resumo:
Light gauge cold-formed steel frame (LSF) structures are increasingly used in industrial, commercial and residential buildings because of their non-combustibility, dimensional stability, and ease of installation. A floor-ceiling system is an example of its applications. LSF floor-ceiling systems must be designed to serve as fire compartment boundaries and provide adequate fire resistance. Fire rated floor-ceiling assemblies formed with new materials and construction methodologies have been increasingly used in buildings. However, limited research has been undertaken in the past and hence a thorough understanding of their fire resistance behaviour is not available. Recently a new composite panel in which an external insulation layer is used between two plasterboards has been developed at QUT to provide a higher fire rating to LSF floors under standard fire conditions. But its increased fire rating could not be determined using the currently available design methods. Research on LSF floor systems under fire conditions is relatively recent and the behaviour of floor joists and other components in the systems is not fully understood. The present design methods thus require the use of expensive fire protection materials to protect them from excessive heat increase during a fire. This leads to uneconomical and conservative designs. Fire rating of these floor systems is provided simply by adding more plasterboard sheets to the steel joists and such an approach is totally inefficient. Hence a detailed fire research study was undertaken into the structural and thermal performance of LSF floor systems including those protected by the new composite panel system using full scale fire tests and extensive numerical studies. Experimental study included both the conventional and the new steel floor-ceiling systems under structural and fire loads using a gas furnace designed to deliver heat in accordance with the standard time- temperature curve in AS 1530.4 (SA, 2005). Fire tests included the behavioural and deflection characteristics of LSF floor joists until failure as well as related time-temperature measurements across the section and along the length of all the specimens. Full scale fire tests have shown that the structural and thermal performance of externally insulated LSF floor system was superior than traditional LSF floors with or without cavity insulation. Therefore this research recommends the use of the new composite panel system for cold-formed LSF floor-ceiling systems. The numerical analyses of LSF floor joists were undertaken using the finite element program ABAQUS based on the measured time-temperature profiles obtained from fire tests under both steady state and transient state conditions. Mechanical properties at elevated temperatures were considered based on the equations proposed by Dolamune Kankanamge and Mahendran (2011). Finite element models were calibrated using the full scale test results and used to further provide a detailed understanding of the structural fire behaviour of the LSF floor-ceiling systems. The models also confirmed the superior performance of the new composite panel system. The validated model was then used in a detailed parametric study. Fire tests and the numerical studies showed that plasterboards provided sufficient lateral restraint to LSF floor joists until their failure. Hence only the section moment capacity of LSF floor joists subjected to local buckling effects was considered in this research. To predict the section moment capacity at elevated temperatures, the effective section modulus of joists at ambient temperature is generally considered adequate. However, this research has shown that it leads to considerable over- estimation of the local buckling capacity of joist subject to non-uniform temperature distributions under fire conditions. Therefore new simplified fire design rules were proposed for LSF floor joist to determine the section moment capacity at elevated temperature based on AS/NZS 4600 (SA, 2005), NAS (AISI, 2007) and Eurocode 3 Part 1.3 (ECS, 2006). The accuracy of the proposed fire design rules was verified with finite element analysis results. A spread sheet based design tool was also developed based on these design rules to predict the failure load ratio versus time, moment capacity versus time and temperature for various LSF floor configurations. Idealised time-temperature profiles of LSF floor joists were developed based on fire test measurements. They were used in the detailed parametric study to fully understand the structural and fire behaviour of LSF floor panels. Simple design rules were also proposed to predict both critical average joist temperatures and failure times (fire rating) of LSF floor systems with various floor configurations and structural parameters under any given load ratio. Findings from this research have led to a comprehensive understanding of the structural and fire behaviour of LSF floor systems including those protected by the new composite panel, and simple design methods. These design rules were proposed within the guidelines of the Australian/New Zealand, American and European cold- formed steel structures standard codes of practice. These may also lead to further improvements to fire resistance through suitable modifications to the current composite panel system.
Resumo:
Cold-formed steel stud walls are an important component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin-walled steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of these wall systems while past research showed contradicting results about the benefits of cavity insulation. This research proposed a new LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating of walls. Full scale fire tests were conducted using both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. Eleven full scale load bearing wall specimens were tested to study the thermal and structural performances of the load bearing wall assemblies under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls while also providing good explanations and supporting test data to overcome the incorrect industry assumptions about cavity insulation. Tests demonstrated that the use of external insulation in a composite panel form enhanced the thermal and structural performances of stud walls and increased their fire resistance rating significantly. This paper presents the details of the full scale fire tests of load-bearing wall assemblies lined with plasterboards and different types of insulation under varying load ratios. Test results including the temperature and deflection profiles of walls measured during the fire tests will be presented along with their failure modes and failure times.
Resumo:
Extreme cold and heat waves, characterised by a number of cold or hot days in succession, place a strain on people’s cardiovascular and respiratory systems. The increase in deaths due to these waves may be greater than that predicted by extreme temperatures alone. We examined cold and heat waves in 99 US cities for 14 years (1987–2000) and investigated how the risk of death depended on the temperature threshold used to define a wave, and a wave’s timing, duration and intensity. We defined cold and heat waves using temperatures above and below cold and heat thresholds for two or more days. We tried five cold thresholds using the first to fifth percentiles of temperature, and five heat thresholds using the ninety-fifth to ninety-ninth percentiles. The extra wave effects were estimated using a two-stage model to ensure that their effects were estimated after removing the general effects of temperature. The increases in deaths associated with cold waves were generally small and not statistically significant, and there was even evidence of a decreased risk during the coldest waves. Heat waves generally increased the risk of death, particularly for the hottest heat threshold. Cold waves of a colder intensity or longer duration were not more dangerous. Cold waves earlier in the cool season were more dangerous, as were heat waves earlier in the warm season. In general there was no increased risk of death during cold waves above the known increased risk associated with cold temperatures. Cold or heat waves earlier in the cool or warm season may be more dangerous because of a build up in the susceptible pool or a lack of preparedness for cold or hot temperatures.
Consecutive days of cold water immersion: effects on cycling performance and heart rate variability.
Resumo:
We investigated performance and heart rate (HR) variability (HRV) over consecutive days of cycling with post-exercise cold water immersion (CWI) or passive recovery (PAS). In a crossover design, 11 cyclists completed two separate 3-day training blocks (120 min cycling per day, 66 maximal sprints, 9 min time trialling [TT]), followed by 2 days of recovery-based training. The cyclists recovered from each training session by standing in cold water (10 °C) or at room temperature (27 °C) for 5 min. Mean power for sprints, total TT work and HR were assessed during each session. Resting vagal-HRV (natural logarithm of square-root of mean squared differences of successive R-R intervals; ln rMSSD) was assessed after exercise, after the recovery intervention, during sleep and upon waking. CWI allowed better maintenance of mean sprint power (between-trial difference [90 % confidence limits] +12.4 % [5.9; 18.9]), cadence (+2.0 % [0.6; 3.5]), and mean HR during exercise (+1.6 % [0.0; 3.2]) compared with PAS. ln rMSSD immediately following CWI was higher (+144 % [92; 211]) compared with PAS. There was no difference between the trials in TT performance (-0.2 % [-3.5; 3.0]) or waking ln rMSSD (-1.2 % [-5.9; 3.4]). CWI helps to maintain sprint performance during consecutive days of training, whereas its effects on vagal-HRV vary over time and depend on prior exercise intensity.
Resumo:
21. Smoking cessation 21.1 Epidemiology of cigarette smoking 21.2 Nicotine, addiction and pharmacokinetics 21.3 Nicotine replacement therapy 21.4 Varenicline 21.5 Bupropion
Resumo:
Food insecurity is the inadequate access to, or availability of, sufficient amounts of nutritious, culturally-appropriate and safe foods, or the inability to acquire such foods by socially acceptable means. Food insecurity has been shown to be associated with poor dietary intakes and poor health status. Recently, evidence has emerged suggesting increased rates of food insecurity among those with substance abuse problems, including those who smoke. This cross-sectional study investigates the potential moderating effect of smoking on the association between food insecurity and fruit and vegetable intakes among the Australian population, using regression analyses. Participants were adults 18 years and older participating in the 2004/05 National Health Survey (n = 19,500). Those from food insecure households were up to two-times more likely to report inadequate fruit and vegetable intakes compared to those who were food secure. Those who smoked were nearly six times more likely to report being food insecure, and up to three-times more likely to report inadequate fruit and vegetable intakes, compared to their non-smoking counterparts. Further analyses revealed a marked decline in the strength of the association between food insecurity and fruit consumption with the addition of smoking status into a regression model. These findings have important implications for the development of policy and interventions to address food insecurity, suggesting that those from food insecure households are less likely to comply with national dietary recommendations, and that this may in part be moderated by smoking status.
Resumo:
While Australia is considered a world leader in tobacco control, smoking rates within the Aboriginal and Torres Strait Islander population have not declined at the same rate. This failure highlights an obvious shortcoming of mainstream anti-smoking efforts to effectively understand and engage with the socio-cultural context of Indigenous smoking and smoking cessation experiences. The purpose of this article is to explore the narrative accounts of 20 Indigenous ex-smokers within an urban community and determine the motivators and enablers for successful smoking cessation. Our findings indicated that health risk narratives and the associated social stigma produced through anti-smoking campaigns formed part of a broader apparatus of oppression among Indigenous people, often inspiring resistance and resentment rather than compliance. Instead, a significant life event and supportive relationships were the most useful predictors of successful smoking cessation acting as both a motivator and enabler to behavioural change. Indigenous smoking cessation narratives most commonly involved changing and reordering a person’s life and identity and autonomy over this process was the critical building block to reclaiming control over nicotine addiction. Most promisingly, at an individual level, we found the important role that individual health professionals played in encouraging and supporting Indigenous smoking cessation through positive rather than punitive interactions. More broadly, our findings highlighted the central importance of resilience, empowerment, and trust within health promotion practice.
Resumo:
The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to −110°C whole body cryotherapy (WBC), and compare these to 8°C cold water immersion (CWI). Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n = 10); thigh skin (average, maximum and minimum) and rectal temperature (n = 10) were recorded before and 60 min after treatment. The greatest reduction (P<0.05) in muscle (mean ± SD; 1 cm: WBC, 1.6±1.2°C; CWI, 2.0±1.0°C; 2 cm: WBC, 1.2±0.7°C; CWI, 1.7±0.9°C; 3 cm: WBC, 1.6±0.6°C; CWI, 1.7±0.5°C) and rectal temperature (WBC, 0.3±0.2°C; CWI, 0.4±0.2°C) were observed 60 min after treatment. The largest reductions in average (WBC, 12.1±1.0°C; CWI, 8.4±0.7°C), minimum (WBC, 13.2±1.4°C; CWI, 8.7±0.7°C) and maximum (WBC, 8.8±2.0°C; CWI, 7.2±1.9°C) skin temperature occurred immediately after both CWI and WBC (P<0.05). Skin temperature was significantly lower (P<0.05) immediately after WBC compared to CWI. The present study demonstrates that a single WBC exposure decreases muscle and core temperature to a similar level of those experienced after CWI. Although both treatments significantly reduced skin temperature, WBC elicited a greater decrease compared to CWI. These data may provide information to clinicians and researchers attempting to optimise WBC and CWI protocols in a clinical or sporting setting.
Resumo:
BACKGROUND: There is evidence that children's decisions to smoke are influenced by family and friends. OBJECTIVES: To assess the effectiveness of interventions to help family members to strengthen non-smoking attitudes and promote non-smoking by children and other family members. SEARCH STRATEGY: We searched 14 electronic bibliographic databases, including the Cochrane Tobacco Addiction Group specialized register, MEDLINE, EMBASE, PsycINFO and CINAHL. We also searched unpublished material, and the reference lists of key articles. We performed both free-text Internet searches and targeted searches of appropriate websites, and we hand-searched key journals not available electronically. We also consulted authors and experts in the field. The most recent search was performed in July 2006. SELECTION CRITERIA: Randomized controlled trials (RCTs) of interventions with children (aged 5-12) or adolescents (aged 13-18) and family members to deter the use of tobacco. The primary outcome was the effect of the intervention on the smoking status of children who reported no use of tobacco at baseline. Included trials had to report outcomes measured at least six months from the start of the intervention. DATA COLLECTION AND ANALYSIS: We reviewed all potentially relevant citations and retrieved the full text to determine whether the study was an RCT and matched our inclusion criteria. Two authors independently extracted study data and assessed them for methodological quality. The studies were too limited in number and quality to undertake a formal meta-analysis, and we present a narrative synthesis. MAIN RESULTS: We identified 19 RCTs of family interventions to prevent smoking. We identified five RCTs in Category 1 (minimal risk of bias on all counts); nine in Category 2 (a risk of bias in one or more areas); and five in Category 3 (risks of bias in design and execution such that reliable conclusions cannot be drawn from the study).Considering the fourteen Category 1 and 2 studies together: (1) four of the nine that tested a family intervention against a control group had significant positive effects, but one showed significant negative effects; (2) one of the five RCTs that tested a family intervention against a school intervention had significant positive effects; (3) none of the six that compared the incremental effects of a family plus a school programme to a school programme alone had significant positive effects; (4) the one RCT that tested a family tobacco intervention against a family non-tobacco safety intervention showed no effects; and (5) the one trial that used general risk reduction interventions found the group which received the parent and teen interventions had less smoking than the one that received only the teen intervention (there was no tobacco intervention but tobacco outcomes were measured). For the included trials the amount of implementer training and the fidelity of implementation are related to positive outcomes, but the number of sessions is not. AUTHORS' CONCLUSIONS: Some well-executed RCTs show family interventions may prevent adolescent smoking, but RCTs which were less well executed had mostly neutral or negative results. There is thus a need for well-designed and executed RCTs in this area.
Resumo:
Cold-formed steel members are increasingly used as primary structural elements in the building industries around the world due to the availability of thin and high strength steels and advanced cold-forming technologies. Cold-formed lipped channel beams (LCB) are commonly used as flexural members such as floor joists and bearers. However, their shear capacities are determined based on conservative design rules. For the shear design of LCB web panels, their elastic shear buckling strength must be determined accurately including the potential post-buckling strength. Currently the elastic shear buckling coefficients of LCB web panels are determined by assuming conservatively that the web panels are simply supported at the junction between their flange and web elements. Hence finite element analyses were conducted to investigate the elastic shear buckling behavior of LCBs. An improved equation for the higher elastic shear buckling coefficient of LCBs was proposed based on finite element analysis results and included in the ultimate shear capacity equations of the North American cold-formed steel codes. Finite element analyses show that relatively short span LCBs without flange restraints are subjected to a new combined shear and flange distortion action due to the unbalanced shear flow. They also show that significant post-buckling strength is available for LCBs subjected to shear. New equations were also proposed in which post-buckling strength of LCBs was included.
Resumo:
Cold-formed steel beams are increasingly used as floor joists and bearers in buildings and often their behaviour and moment capacities are influenced by lateral-torsional buckling. With increasing usage of cold-formed steel beams their fire safety design has become an important issue. Fire design rules are commonly based on past research on hot-rolled steel beams. Hence a detailed parametric study was undertaken using validated finite element models to investigate the lateral-torsional buckling behaviour of simply supported cold-formed steel lipped channel beams subjected to uniform bending at uniform elevated temperatures. The moment capacity results were compared with the predictions from the available ambient temperature and fire design rules and suitable recommendations were made. European fire design rules were found to be over-conservative while the ambient temperature design rules could not be used based on single buckling curve. Hence a new design method was proposed that includes the important non-linear stress-strain characteristics observed for cold-formed steels at elevated temperatures. Comparison with numerical moment capacities demonstrated the accuracy of the new design method. This paper presents the details of the parametric study, comparisons with current design rules and the new design rules proposed in this research for lateral-torsional buckling of cold-formed steel lipped channel beams at elevated temperatures.
Resumo:
Current design standards do not provide adequate guidelines for the fire design of cold-formed steel compression members subject to flexural-torsional buckling. Eurocode 3 Part 1.2 (2005) recommends the same fire design guidelines for both hot-rolled and cold-formed steel compression members subject to flexural-torsional buckling although considerable behavioural differences exist between cold-formed and hot-rolled steel members. Past research has recommended the use of ambient temperature cold-formed steel design rules for the fire design of cold-formed steel compression members provided appropriately reduced mechanical properties are used at elevated temperatures. To assess the accuracy of flexural-torsional buckling design rules in both ambient temperature cold-formed steel design and fire design standards, an experimental study of slender cold-formed steel compression members was undertaken at both ambient and elevated temperatures. This paper presents the details of this experimental study, its results, and their comparison with the predictions from the current design rules. It was found that the current ambient temperature design rules are conservative while the fire design rules are overly conservative. Suitable recommendations have been made in relation to the currently available design rules for flexural-torsional buckling including methods of improvement. Most importantly, this paper has addressed the lack of experimental results for slender cold-formed steel columns at elevated temperatures.
Resumo:
The LiteSteel Beam (LSB) is a new hollow flange section developed in Australia with a unique geometry consisting of torsionally rigid rectangular hollow flanges and a relatively slender web. The LSB is subjected to a relatively new Lateral Distortional Buckling (LDB) mode when used as flexural members. Unlike the commonly observed lateral torsional buckling, lateral distortional buckling of LSBs is characterised by cross sectional change due to web distortion. Lateral distortional buckling causes significant moment capacity reduction for LSBs with intermediate spans. Therefore a detailed investigation was undertaken to determine the methods of reducing the effects of lateral distortional buckling in LSB flexural members. For this purpose the use of web stiffeners was investigated using finite element analyses of LSBs with different web stiffener spacing and sizes. It was found that the use of 5 mm steel plate stiffeners welded or screwed to the inner faces of the top and bottom flanges at third span points considerably reduced the lateral distortional buckling effects in LSBs. Suitable design rules were then developed to calculate the enhanced elastic lateral distortional buckling moments and the higher ultimate moment capacities of LSBs with the chosen web stiffener arrangement. This paper presents the details of this investigation and the results.
Resumo:
Introduction and aims: Individual smokers from disadvantaged backgrounds are less likely to quit, which contributes to widening inequalities in smoking. Residents of disadvantaged neighbourhoods are more likely to smoke, and neighbourhood inequalities in smoking may also be widening because of neighbourhood differences in rates of cessation. This study examined the association between neighbourhood disadvantage and smoking cessation and its relationship with neighbourhood inequalities in smoking. Design and methods: A multilevel longitudinal study of mid-aged (40-67 years) residents (n=6915) of Brisbane, Australia, who lived in the same neighbourhoods (n=200) in 2007 and 2009. Neighbourhood inequalities in cessation and smoking were analysed using multilevel logistic regression and Markov chain Monte Carlo simulation. Results: After adjustment for individual-level socioeconomic factors, the probability of quitting smoking between 2007 and 2009 was lower for residents of disadvantaged neighbourhoods (9.0%-12.8%) than their counterparts in more advantaged neighbourhoods (20.7%-22.5%). These inequalities in cessation manifested in widening inequalities in smoking: in 2007 the between-neighbourhood variance in rates of smoking was 0.242 (p≤0.001) and in 2009 it was 0.260 (p≤0.001). In 2007, residents of the most disadvantaged neighbourhoods were 88% (OR 1.88, 95% CrI 1.41-2.49) more likely to smoke than residents in the least disadvantaged neighbourhoods: the corresponding difference in 2009 was 98% (OR 1.98 95% CrI 1.48-2.66). Conclusion: Fundamentally, social and economic inequalities at the neighbourhood and individual-levels cause smoking and cessation inequalities. Reducing these inequalities will require comprehensive, well-funded, and targeted tobacco control efforts and equity based policies that address the social and economic determinants of smoking.
Resumo:
Cold water immersion (CWI) is a popular recovery modality, but actual physiological responses to CWI after exercise in the heat have not been well documented. The purpose of this study was to examine effects of 20-min CWI (14 degrees C) on neuromuscular function, rectal (T(re)) and skin temperature (T(sk)), and femoral venous diameter after exercise in the heat. Ten well-trained male cyclists completed two bouts of exercise consisting of 90-min cycling at a constant power output (216+/-12W) followed by a 16.1km time trial (TT) in the heat (32 degrees C). Twenty-five minutes post-TT, participants were assigned to either CWI or control (CON) recovery conditions in a counterbalanced order. T(re) and T(sk) were recorded continuously, and maximal voluntary isometric contraction torque of the knee extensors (MVIC), MVIC with superimposed electrical stimulation (SMVIC), and femoral venous diameters were measured prior to exercise, 0, 45, and 90min post-TT. T(re) was significantly lower in CWI beginning 50min post-TT compared with CON, and T(sk) was significantly lower in CWI beginning 25min post-TT compared with CON. Decreases in MVIC, and SMVIC torque after the TT were significantly greater for CWI compared with CON; differences persisted 90min post-TT. Femoral vein diameter was approximately 9% smaller for CWI compared with CON at 45min post-TT. These results suggest that CWI decreases T(re), but has a negative effect on neuromuscular function.