954 resultados para city hall


Relevância:

100.00% 100.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inscriptions: Verso: [stamped] Photograph by Freda Leinwand. [463 West Street, Studio 229G, New York, NY 10014].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inscriptions: Verso: [stamped] Photograph by Freda Leinwand. [463 West Street, Studio 229G, New York, NY 10014].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project proposes two possible solutions for the phasing plan of the intersection near the City Hall of Leiria and presents the calculations of the cycle length and the intersection delay for both of them. The main goal of these solutions is to optimize the global functioning of the intersection. Since the number of cars that use an intersection is will fluctuate with time, when using pre-timed traffic lights, adjustments are needed to the settings of the traffic signals, to assure the accommodation of the present traffic flows in the intersection under acceptable conditions for drivers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

General street map showing wards, piers, pier numbers, and streetcar lines.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

General street map showing wards, piers, pier numbers, and streetcar lines.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

General-content double-line street map of Brooklyn city (Kings County, N.Y.) showing municipal ward numbers and horsecar lines.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

General-content double-line street map of Brooklyn city (Kings County, N.Y.) showing municipal ward numbers and horsecar lines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The emission factors of a bus fleet consisting of approximately three hundreds diesel powered buses were measured in a tunnel study under well controlled conditions during a two-day monitoring campaign in Brisbane. The number concentration of particles in the size range 0.017-0.7 m was monitored simultaneously by two Scanning Mobility Particle Sizers located at the tunnel’s entrance and exit. The mean value of the number emission factors was found to be (2.44±1.41)×1014 particles km-1. The results are in good agreement with the emission factors determined from steady-state dynamometer testing of 12 buses from the same Brisbane City bus fleet, thus indicating that when carefully designed, both approaches, the dynamometer and on-road studies, can provide comparable results, applicable for the assessment of the effect of traffic emissions on airborne particle pollution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Assessment and prediction of the impact of vehicular traffic emissions on air quality and exposure levels requires knowledge of vehicle emission factors. The aim of this study was quantification of emission factors from an on road, over twelve months measurement program conducted at two sites in Brisbane: 1) freeway type (free flowing traffic at about 100 km/h, fleet dominated by small passenger cars - Tora St); and 2) urban busy road with stop/start traffic mode, fleet comprising a significant fraction of heavy duty vehicles - Ipswich Rd. A physical model linking concentrations measured at the road for specific meteorological conditions with motor vehicle emission factors was applied for data analyses. The focus of the study was on submicrometer particles; however the measurements also included supermicrometer particles, PM2.5, carbon monoxide, sulfur dioxide, oxides of nitrogen. The results of the study are summarised in this paper. In particular, the emission factors for submicrometer particles were 6.08 x 1013 and 5.15 x 1013 particles per vehicle-1 km-1 for Tora St and Ipswich Rd respectively and for supermicrometer particles for Tora St, 1.48 x 109 particles per vehicle-1 km-1. Emission factors of diesel vehicles at both sites were about an order of magnitude higher than emissions from gasoline powered vehicles. For submicrometer particles and gasoline vehicles the emission factors were 6.08 x 1013 and 4.34 x 1013 particles per vehicle-1 km-1 for Tora St and Ipswich Rd, respectively, and for diesel vehicles were 5.35 x 1014 and 2.03 x 1014 particles per vehicle-1 km-1 for Tora St and Ipswich Rd, respectively. For supermicrometer particles at Tora St the emission factors were 2.59 x 109 and 1.53 x 1012 particles per vehicle-1 km-1, for gasoline and diesel vehicles, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As the society matures, there was an increasing pressure to preserve historic buildings. The economic cost in maintaining these important heritage legacies has become the prime consideration of every state. Dedicated intelligent monitoring systems supplementing the traditional building inspections will enable the stakeholder to carry out not only timely reactive response but also plan the maintenance in a more vigilant approach; thus, preventing further degradation which was very costly and difficult to address if neglected. The application of the intelligent structural health monitoring system in this case studies of ‘modern heritage’ buildings is on its infancy but it is an innovative approach in building maintenance. ‘Modern heritage’ buildings were the product of technological change and were made of synthetic materials such as reinforced concrete and steel. Architectural buildings that was very common in Oceania and The Pacific. Engineering problems that arose from this type of building calls for immediate engineering solution since the deterioration rate is exponential. The application of this newly emerging monitoring system will improve the traditional maintenance system on heritage conservation. Savings in time and resources can be achieved if only pathological results were on hand. This case study will validate that approach. This publication will serve as a position paper to the on-going research regarding application of (Structural Health Monitoring) SHM systems to heritage buildings in Brisbane, Australia. It will be investigated with the application of the SHM systems and devices to validate the integrity of the recent structural restoration of the newly re-strengthened heritage building, the Brisbane City Hall.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

During post-disaster recovery, an infrastructure system may be subject to a number of disturbances originating from several other interdependent infrastructures. These disturbances might result in a series of system failures, thereby having immediate impact on societal living conditions. The inability to detect signs of disturbance from one infrastructure during recovery might cause significant disruptive effects on other infrastructure via the interconnection that exist among them. In such circumstances, it clearly appears that critical infrastructures' interdependencies affect the recovery of each individual infrastructure, as well as those of other interdependent infrastructure systems. This is why infrastructure resilience needs to be improved in function of those interdependencies, particularly during the recovery period to avoid the occurrence of a ‘disaster of disaster’ scenario. Viewed from this perspective, resilience is achieved through an inter-organisational collaboration between the different organisations involved in the reconstruction of interdependent infrastructure systems. This paper suggests that to some extent, the existing degree of interconnectedness between these infrastructure systems can also be found in their resilience ability during post-disaster recovery. For instance, without a resilient energy system, a large-scale power outage could affect simultaneously all the interdependent infrastructures after a disaster. Thus, breaking down the silos of resilience would be the first step in minimizing the risks of disaster failures from one infrastructure to cascade or escalate to other interconnected systems.