983 resultados para catheter ablation


Relevância:

70.00% 70.00%

Publicador:

Resumo:

- Réalisé au centre de recherche de l'hospital du Sacré-Coeur de Montréal. - Programme conjoint entre Université de Montréal et École Polytechnique de Montréal.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Steam pops are a risk of irrigated radiofrequency catheter ablation (RFA) and may cause cardiac perforation. Data to guide radiofrequency (RF) energy titration to avoid steam pops are limited. OBJECTIVE: This study sought to assess the frequency and consequence of audible pops and to determine the feasibility of using the magnitude of impedance change to predict pops. METHODS: We reviewed consecutive endocardial open-irrigated RFA for ventricular tachycardia (VT) with continuously recorded ablation data in 142 patients with structural heart disease. Steam pops were defined as an audible pop associated with a sudden spike in impedance. Ablation lesions before or after pops served as controls. RESULTS: From a total of 4,107 ablation lesions, 62 (1.5%) steam pops occurred in 42 procedures in 38 patients. Perforation with tamponade occurred with 1 of 62 (2%) pops. Applications with pops had a greater impedance decrease (22 +/- 7 Omega vs. 18 +/- 8 Omega, P = .001) and a higher maximum power (45 +/- 5 W vs. 43 +/- 6 W, P = .011), but did not differ in maximum catheter tip temperature (40 degrees C +/- 4 degrees C vs. 40 degrees C +/- 4 degrees C, P = .180) from applications without pops. Eighty percent of pops occurred after impedance decreased by at least 18 Omega. CONCLUSION: During VT ablation with open irrigation, audible pops are infrequent and do not usually cause perforation. Limiting RF power to achieve an impedance decrease of <18 Omega is a feasible method of reducing the likelihood of a pop when perforation risk is of concern.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Ablation of ventricular tachycardia (VT) by conventional radiofrequency ablation can be impossible if the ventricular wall at the targeted ablation site is very thick, as for example the ventricular septum. We present a case of a patient with incessant, non-sustained slow VT originating from the septal part of the lower outflow tracts. Radiofrequency catheter ablation from both ventricles as well as from the anterior cardiac vein were not successful. Both high power radiofrequency ablation and bipolar radiofrequency ablation neither were successfull. Finally, ethanol ablation of the first septal perforator successfully terminated arrhythmia. We discuss the possibilities to overcome failed conventional radiofrequency VT ablation of a septal focus.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

UNLABELLED The abnormal development of the tricuspid valve in patients with Ebstein's anomaly results in several activation abnormalities including delayed intraatrial conduction, right bundle branch block (RBBB), and ventricular preexcitation. The aim of the present study was to define the ECG characteristics before and after ablation of an accessory A-V pathway (AP) in patients with Ebstein's anomaly. METHODS A series of 226 consecutive patients with Ebstein's anomaly was studied. Sixty-four patients (28%) had documented tachycardia. Thirty-three patients with recurrent tachycardia were found to have a single right-sided AP that was successfully ablated (study group). Thirty patients without tachycardia served as the control group. RESULTS Only 21 of 33 patients (62%) had a typical ECG pattern of preexcitation. In addition, none of the patients had an ECG pattern of RBBB during sinus rhythm. In contrast, 28 of 30 (93%) patients in the control group had RBBB (P < 0.001). Radiofrequency catheter ablation resulted in appearance of RBBB in 31 of 33 (94%) patients. The absence of RBBB in patients with Ebstein's anomaly and recurrent tachycardia had a 98% sensitivity and 92% specificity for the diagnosis of an AP. The positive predictive value was 91% (0.77, 0.97 CI 95%) and the negative predictive value was 98% (0.85, 0.99 CI 95%). CONCLUSION One-third of patients with Ebstein's anomaly and symptomatic tachyarrhythmias have minimal or absent ECG features of ventricular preexcitation. In these patients, the absence of RBBB pattern is a strong predictor of an AP.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to review the clinical and electrophysiological characteristics and results of radiofrequency catheter ablation in patients with multiple accessory pathways to compare them with those of patients with single accessory pathways. Electrophysiological study and radiofrequency catheter ablation were performed in 1010 consecutive cases with Wolff Parkinson White Syndrome. Presence of multiple accessory pathways was documented in 31 patients (3.1%); 30 had two, and 1 had three accessory pathways. Of the 63 accessory pathways, 42 were manifest and 21 concealed. Nine patients had Ebstein's anomaly associated with atrioventricular bypass tracts. The most common combination was right posteroseptal with right free wall bypass tracts (15 patients with 30 accessory pathways). Fifty-one of the sixty-three accessory pathways (81%) were ablated successfully without complications. The duration of the procedure was 100 +/- 58 min and the fluoroscopic time 40 +/- 17 min. A follow up of 5 +/- 3 years after ablation, demonstrated recurrences of six accessory pathways (9.5%). In conclusion, patients with multiple accessory pathways can be treated by radiofrequency ablation in only one session with a high success rate although slightly less than that in patients with a single accessory pathway (81% vs 93%, P<0.01).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND The objective of this study was to compare transtelephonic ECG every 2 days and serial 7-day Holter as two methods of follow-up after atrial fibrillation (AF) catheter ablation for the judgment of ablation success. Patients with highly symptomatic AF are increasingly treated with catheter ablation. Several methods of follow-up have been described, and judgment on ablation success often relies on patients' symptoms. However, the optimal follow-up strategy objectively detecting most of the AF recurrences is yet unclear. METHODS Thirty patients with highly symptomatic AF were selected for circumferential pulmonary vein ablation. During follow-up, a transtelephonic ECG was transmitted once every 2 days for half a year. Additionally, a 7-day Holter was recorded preablation, after ablation, after 3 and 6 months, respectively. With both, procedures symptoms and actual rhythm were correlated thoroughly. RESULTS A total of 2,600 transtelephonic ECGs were collected with 216 of them showing AF. 25% of those episodes were asymptomatic. On a Kaplan-Meier analysis 45% of the patients with paroxysmal AF were still in continuous SR after 6 months. Simulating a follow-up based on symptomatic recurrences only, that number would have increased to 70%. Using serial 7-day ECG, 113 Holter with over 18,900 hours of ECG recording were acquired. After 6 months the percentage of patients classified as free from AF was 50%. Of the patients with recurrences, 30-40% were completely asymptomatic. The percentage of asymptomatic AF episodes stepwise increased from 11% prior ablation to 53% 6 months after. CONCLUSIONS The success rate in terms of freedom from AF was 70% on a symptom-only-based follow-up; using serial 7-day Holter it decreased to 50% and on transtelephonic monitoring to 45%, respectively. Transtelephonic ECG and serial 7-day Holter were equally effective to objectively determine long-term success and to detect asymptomatic patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to analyze different anatomic mapping approaches for successful ablation of outflow tract tachycardia with R/S transition in lead V(3). BACKGROUND Idiopathic ventricular tachycardia can originate from different areas in the outflow tract, including the right and left ventricular endocardium, the epicardium, the pulmonary artery, and the aortic sinus of Valsalva. Although electrocardiographic criteria may be helpful in predicting the area of origin, sometimes the focus is complex to determine, especially when QRS transition in precordial leads is in V(3). METHODS We analyzed surface electrocardiograms of 33 successfully ablated patients with outflow tract tachycardia: 20 from the right ventricular outflow tract (RVOT) and 13 from different sites. The R/S transition was determined, and the different anatomic approaches needed for successful catheter ablation were studied. RESULTS Overall, R/S transition in lead V(3) was present in 19 (58%) of all patients. In these patients, mapping was started and successfully completed in the RVOT in 11 of 19 (58%) patients. The remaining eight patients with R/S transition in lead V(3) needed five additional anatomic accesses for successful ablation: from the left ventricular outflow tract (n = 3), aortic sinus of Valsalva (n = 2), coronary sinus (n = 1), the epicardium via pericardial puncture (n = 1), and the trunk of the pulmonary artery (n = 1), respectively. CONCLUSIONS A R/S transition in lead V(3) is common. In patients with outflow tract tachycardia with R/S transition in lead V(3), a stepwise endocardial and epicardial mapping through up to six anatomic approaches can lead to successful radiofrequency catheter ablation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

UNLABELLED Topography of the esophagus in atrial fibrillation ablation. INTRODUCTION The close anatomic relationship of the posterior wall of the left atrium (LA) and the thermosensitive esophagus creates a potential hazard in catheter ablation procedures. METHODS AND RESULTS In 30 patients (pts) with atrial fibrillation (AF) undergoing catheter ablation, we prospectively studied the course and contact of the esophagus in relation to LA and the topographic proximity to ablation lines encircling the right-sided and left-sided pulmonary veins (PV) as well as to the posterior line connecting the encircling lines using the electromagnetic mapping system for reconstruction of LA and for tagging of the esophagus. This new technique of anatomic tagging of the esophagus was validated against the CT scan as a standard imaging procedure. The esophageal course was highly variable, extending from courses in direct vicinity to the left- or right-sided PV as well as in the midportion of the posterior LA. In order to avoid energy application in direct proximity to the esophagus, adjustments of the left and right PV encircling lines were necessary in 14/30 pts (47%) and 3/30 (10%). In 30 pts (100%), the mid- to inferior areas of the posterior LA revealed contact with the esophagus. Therefore, posterior and inferior linear ablation lines were abandoned and shifted to superior in 29 pts (97%). CONCLUSIONS Anatomic tagging of esophagus revealed a highly variable proximity to different areas of the posterior LA suggesting individual adjustment of encircling and linear ablation lines in AF ablation procedures to avoid the life threatening complication of esophagus perforation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to determine the incidence of atrial flutter and other arrhythmia recurrences (other than atrial fibrillation [AF]) during long-term follow-up after left atrial substrate modification by percutaneous radiofrequency (RF) ablation of AF. BACKGROUND RF ablation is an effective treatment for patients with AF. However, late recurrent arrhythmias may complicate the patient's course. METHODS One hundred fifty consecutive patients with paroxysmal or persistent AF were included in this prospective study. The incidence of arrhythmia recurrences after AF ablation was analyzed during long-term follow-up using repetitive 7-day ECG recording. RESULTS In 28 of 150 patients (18.7%), stable regular arrhythmias other than AF were detected during follow-up. Left atrial flutter observed in 10 patients (6.7%) was treated by recompletion of the ablation lines in all 10 patients. Left atrial flutter was associated with recurrence of AF in all 10 patients. Nine of 10 patients (90%) were free from atrial flutter and 6 of 10 patients were free from AF after the second intervention. Typical right atrial flutter occurred in 10 patients (6.7%) and was treated successfully by percutaneous RF ablation without recurrence in all patients. Additionally, atrial flutter was documented during follow-up in 7 patients (4.7%); however, invasive electrophysiologic evaluation was not performed due to various reasons. CONCLUSIONS Left atrial flutter is a relevant complication after RF catheter ablation of AF and was always associated with AF recurrence in our study population. Prevention of left atrial flutter can be achieved by induction of ablation lines as continuous and transmural as possible. However, left atrial flutter that does occur late after ablation is amenable to interventional treatment with good prospects of success.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND The role of subsequent atrial tachycardias (AT) in the context of persistent atrial fibrillation (AF) remains undetermined. This study evaluated the prognostic role of subsequent ATs for arrhythmia recurrences after catheter ablation of persistent AF. METHODS AND RESULTS A total of 110 patients with persistent AF (63±9 years; 22 women; 61 long-lasting persistent AF) underwent pulmonary vein isolation followed by electrogram-guided ablation. After AF terminated to AT, patients were separated by the randomization protocol to receive either direct cardioversion (group A) or further ablation of subsequent ATs to sinus rhythm (group B). After a mean follow-up of 20.1±13.3 months after the first procedure, significantly more group B patients were in sinus rhythm as compared with patients in group A (30 [57%] versus 18 [34%]; P=0.02). Moreover, recurrences of AF were significantly less frequent of group B than in group A patients (10 [19%] versus 26 [49%]; P=0.001). After the last procedure (follow-up, 34.0±6.4 months), significantly more group B patients were free of AF as compared with patients of group A (49 [92%] versus 39 [74%]; P=0.01). The proportion of AT recurrences did not differ between the 2 groups after the first and final procedures. The strongest predictor for an arrhythmia-free survival after a single procedure was randomization to the procedural end point of termination to sinus rhythm by elimination of subsequent ATs (P=0.004). CONCLUSIONS Catheter ablation of subsequent ATs increases freedom from AF but not AT, suggesting a contributing role of subsequent ATs in the mechanisms of persistent AF. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01896570.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Catheter ablation (CA) of ventricular tachycardia (VT) is an important treatment option in patients with structural heart disease (SHD) and implantable cardioverter defibrillator (ICD). A subset of patients requires epicardial CA for VT. Objective The purpose of the study was to assess the significance of epicardial CA in these patients after a systematic sequential endocardial approach. Methods Between January 2009 and October 2012 CA for VT was analyzed. A sequential CA approach guided by earliest ventricular activation, pacemap, entrainment and stimulus to QRS-interval analysis was used. Acute CA success was assessed by programmed ventricular stimulation. ICD interrogation and 24 h-Holter ECG were used to evaluate long-term success. Results One hundred sixty VT ablation procedures in 126 consecutive patients (114 men; age 65 ± 12 years) were performed. Endocardial CA succeeded in 250 (94%) out of 265 treated VT. For 15 (6%) VT an additional epicardial CA was performed and succeeded in 9 of these 15 VT. Long-term FU (25 ± 18.2 month) showed freedom of VT in 104 pts (82%) after 1.2 ± 0.5 procedures, 11 (9%) suffered from repeated ICD shocks and 11 (9%) died due to worsening of heart failure. Conclusions Despite a heterogenic substrate for VT in SHD, endocardial CA alone results in high acute success rates. In this study additional epicardial CA following a sequential endocardial mapping and CA approach was performed in 6% of VT. Thus, due to possible complications epicardial CA should only be considered if endocardial CA fails.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.