974 resultados para capacitance-frequency characteristics


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The charactesistics of two-dimension spectra obtained by inductively coupled plasma atomic emission spectrometry (ICP-AES) with charge injection detection (CID) in frequency domain were studied in the present paper. The measurement spectra were Fourier transformed and the frequency distribution of the spectra was obtained. Results showed that the spectra in frequency domain could he divided into two parts:high frequency and low frequency signals. The later stood for measurement spectra and the former for background and noises. However, the high frequecny signals could not be smoothed simply to reduce noises because the background was deteriorated even though the spectral signal did not change significantly.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two deep-sea moorings were deployed respectively in the east area and the west area of Chinese Pioneer Area (CPA) in the tropic east Pacific to monitor the regional deep-sea dynamics below 600 meters above bottom (mab) from July 1997 to Oct. 1999. Results of statistics, spectral estimate and correlation analysis of the low-passed velocity data show that time scales of low-frequency components of the near-bottom currents are 25similar to120 days, in which 51-day period dominates the lower band of the frequency domain. Topographic features have obvious effect on low-frequency currents below 50 mab; modulations of the bottom-intensified sheared mean flow to the low-frequency currents are the dynamic mechanism of the frequency shift that occurs in both the east-area and the west-area.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A pin diode-loaded active doubly periodic flat strip FSS is shown to act as a dynamic screen. It is shown that by means of d.c. bias control, we can utilize the screen in, (1) transmission mode as a dual band electromagnetic shutter, or with the inclusion of a ground plane in reflection mode, (is (2) it dual band refection canceller. (3) an amplitude shift keying (ASK) spatial modulator. The properties of the FSS are characterized using a specially designed parallel plate waveguide simulator that permits normal incidence excitation of the FSS under test. (C) 2009 Wiley Periodicals. Inc. Microwave Opt Technol Lett 51: 2059-2061, 2009; Published online in Wiley Inter-Science (www. interscience.wiley.com). DOI 10.1002/mop.24547

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A Physical Unclonable Function (PUF) can be used to provide authentication of devices by producing die-unique responses. In PUFs based on ring oscillators (ROs) the responses are derived from the oscillation frequencies of the ROs. However, RO PUFs can be vulnerable to attack due to the frequency distribution characteristics of the RO arrays. In this letter, in order to improve the design of RO PUFs for FPGA devices, the frequencies of RO arrays implemented on a large number of FPGA chips are statistically analyzed. Three RO frequency distribution (ROFD) characteristics, which can be used to improve the design of RO PUFs are observed and discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Medication safety is of increasing importance and understanding the nature and frequency of medication errors in the Emergency Department (ED) will assist in tailoring interventions which will make patient care safer. The challenge with the literature to date is the wide variability in the frequency of errors reported and the reliance on incident reporting practices of busy ED staff. Methods: A prospective, exploratory descriptive design using point prevalence surveys was used to establish the frequency of observed medication errors in the ED. In addition, data related to contextual factors such as ED patients, staffing and workload were also collected during the point prevalence surveys to enable the analysis of relationships between the frequency and nature of specific error types and patient and ED characteristics at the time of data collection. Results: A total of 172 patients were included in the study: 125 of whom patients had a medication chart. The prevalence of medication errors in the ED studied was 41.2% for failure to apply patient ID bands, 12.2% for failure to document allergy status and 38.4% for errors of omission. The proportion of older patients in the ED did not affect the frequency of medication errors. There was a relationship between high numbers of ATS 1, 2 and 3 patients (indicating high levels of clinical urgency) and increased rates of failure to document allergy status. Medication errors were affected by ED occupancy, when cubicles in the ED were over 50% occupied, medication errors occurred more frequently. ED staffing affects the frequency of medication errors, there was an increase in failure to apply ID bands and errors of omission when there were unfilled nursing deficits and lower levels of senior medical staff were associated with increased errors of omission. Conclusions: Medication errors related to patient identification, allergy status and medication omissions occur more frequently in the ED when the ED is busy, has sicker patients and when the staffing is not at the minimum required staffing levels.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To investigate: (i) how lunch frequency of adolescents varies between schools and between classes within schools; (ii) the associations between frequency of lunch and individual sociodemographic factors and school characteristics; and (iii) if any observed associations between lunch frequency and school characteristics vary by gender and age groups. Design: Cross-sectional study in which students and school headmasters completed self-administered questionnaires. Associations were estimated by multilevel multivariate logistic regression. Setting: The Danish arm of the Health Behaviour in School-Aged Children study 2010. Subjects: Students (n 4922) aged 11, 13 and 15 years attending a random sample of seventy-three schools. Results: The school-level and class-level variations in low lunch frequency were small (intraclass correlation coefficient <2·1 %). At the individual level, low lunch frequency was most common among students who were boys, 13- and 15-year-olds, from medium and low family social class, descendants of immigrants, living in a single-parent family and in a reconstructed family. School-level analyses suggested that having access to a canteen at school was associated with low lunch frequency (OR=1·47; 95% CI 1·14, 1·89). Likewise not having an adult present during lunch breaks was associated with low lunch frequency (OR=1·44; 95% CI 1·18, 1·75). Cross-level interactions suggested that these associations differed by age group. Conclusions: Lunch frequency among Danish students appears to be largely influenced by sociodemographic factors. Additionally, the presence of an adult during lunch breaks promotes frequent lunch consumption while availability of a canteen may discourage frequent lunch consumption. These findings vary between older and younger students.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electrochemical analyses on confined electroactive molecular layers, herein exemplified with electroactive self-assembled monolayers, sample current contributions that are significantly influenced by additional nonfaradaic and uncompensated resistance effects that, though unresolved, can strongly distort redox analysis. Prior work has shown that impedance-derived capacitance spectroscopy approaches can cleanly resolve all contributions generated at such films, including those which are related to the layer dipolar/electrostatic relaxation characteristics. We show herein that, in isolating the faradaic and nonfaradaic contributions present within an improved equivalent circuit description of such interfaces, it is possible to accurately simulate subsequently observed cyclic voltammograms (that is, generated current versus potential patterns map accurately onto frequency domain measurements). Not only does this enable a frequency-resolved quantification of all components present, and in so doing, a full validation of the equivalent circuit model utilized, but also facilitates the generation of background subtracted cyclic voltammograms remarkably free from all but faradaic contributions. © 2012 American Chemical Society.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An electrical model able to decouple the electron pathway from microbial cell machinery impedance terms is introduced. In this context, capacitance characteristics of the biofilm are clearly resolved. In other words, the model allows separating, according to the advantage of frequency and spectroscopic response approach, the different terms controlling the performance of the microbial biofilm respiratory process and thus the directly related electricity production process. The model can be accurately fitted to voltammetry measurements obtained under steady-state conditions and also to biofilm discharge amperometric measurements. The implications of biological aspects of the electrochemical or redox capacitance are discussed theoretically in the context of current knowledge with regard to structure and physiological activity of microbial Geobacter biofilms.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To estimate the frequency and describe the clinical characteristics and respective treatments of previous history of wheezing. Methods: Infants aged 6-23 months with upper respiratory tract complaints and reporting previous wheezing were followed-up retrospectively. Data were registered on a validated standardized form. Results: Out of 451 infants, 164 (36.4%; 95%CI: 31.9-41.0) had a report of prior history of wheezing, 148 (32.8%; 95%CI: 28.5-37.4) during the first year of life. The mean age at the first episode of wheezing was 5.3 +/- 3.9 months. Among those who had had their first episode before 12 months of age, 38.5% reported 3 to 6 episodes and 14.2% > 6 episodes. Mean age at first episode was lower for those with a >= 3 episodes in comparison with those with <= 2 episodes (3.2 +/- 2.7 vs. 5.7 +/- 2.5 months, p < 0.001). Conclusion: One third of the infants reported wheezing during the first year of life. The earlier the first episode occurs, the more frequently wheezing recurs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To monitor resonance frequency analysis (RFA) in relation to the jawbone characteristics and during the early phases of healing and incorporation of Straumann dental implants with an SLA surface. MATERIAL AND METHODS: 17 Straumann 4.1 mm implants (10 mm) and 7 Straumann 4.8 mm implants (10 mm) were installed and ISQ determined at baseline and after 1, 2, 3, 4, 5, 6, 8 and 12 weeks. Central bone cores were analyzed from the 4.1 mm implants using micro CT for bone volume density (BVD) and bone trabecular connectivity (BTC). RESULTS: Pocket probing depths ranged from 2-4 mm and bleeding on probing from 5-20%. At baseline, BVD varied between 24% and 65% and BTC between 4.9 and 25.4 for the 4.1 mm implants. Baseline ISQ varied between 55 and 74 with a mean of 61.4. No significant correlations were found between BVD or BTC and ISQ Values. For the 4.8 mm diameter implants baseline ISQ values ranged from 57-70 with a mean of 63.3. Over the healing period ISQ values increased at 1 week and decreased after 2-3 weeks. After 4 weeks ISQ values, again increased slightly, no significant differences were noted over time. One implant (4.1 mm) lost stability at 3 weeks. Its ISQ value had dropped from 68 to 45. However the latter value was determined after the clinical diagnosis of instability. CONCLUSION: ISQ values of 57-70 represented homeostasis and implant stability. However no predictive value for loosing implant stability can be attributed to RFA since the decrease occurred after the fact.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The evolution of water content on a sandy soil during the sprinkler irrigation campaign, in the summer of 2010, of a field of sugar beet crop located at Valladolid (Spain) is assessed by a capacitive FDR (Frequency Domain Reflectometry) EnviroScan. This field is one of the experimental sites of the Spanish research center for the sugar beet development (AIMCRA). The objective of the work focus on monitoring the soil water content evolution of consecutive irrigations during the second two weeks of July (from the 12th to the 28th). These measurements will be used to simulate water movement by means of Hydrus-2D. The water probe logged water content readings (m3/m3) at 10, 20, 40 and 60 cm depth every 30 minutes. The probe was placed between two rows in one of the typical 12 x 15 m sprinkler irrigation framework. Furthermore, a texture analysis at the soil profile was also conducted. The irrigation frequency in this farm was set by the own personal farmer 0 s criteria that aiming to minimizing electricity pumping costs, used to irrigate at night and during the weekend i.e. longer irrigation frequency than expected. However, the high evapotranspiration rates and the weekly sugar beet water consumption—up to 50mm/week—clearly determined the need for lower this frequency. Moreover, farmer used to irrigate for six or five hours whilst results from the EnviroScan probe showed the soil profile reaching saturation point after the first three hours. It must be noted that AIMCRA provides to his members with a SMS service regarding weekly sugar beet water requirement; from the use of different meteorological stations and evapotranspiration pans, farmers have an idea of the weekly irrigation needs. Nevertheless, it is the farmer 0 s decision to decide how to irrigate. Thus, in order to minimize water stress and pumping costs, a suitable irrigation time and irrigation frequency was modeled with Hydrus-2D. Results for the period above mentioned showed values of water content ranging from 35 and 30 (m3/m3) for the first 10 and 20cm profile depth (two hours after irrigation) to the minimum 14 and 13 (m3/m3) ( two hours before irrigation). For the 40 and 60 cm profile depth, water content moves steadily across the dates: The greater the root activity the greater the water content variation. According to the results in the EnviroScan probe and the modeling in Hydrus-2D, shorter frequencies and irrigation times are suggested.