898 resultados para bridge circuits, DC-AC power convertors, harmonic distortion, probability, PWM inverters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dual-active bridges (DABs) can be used to deliver isolated and bidirectional power to electric vehicles (EVs) or to the grid in vehicle-to-grid (V2G) applications. However, such a system essentially requires a two-stage power conversion process, which significantly increases the power losses. Furthermore, the poor power factor associated with DAB converters further reduces the efficiency of such systems. This paper proposes a novel matrix converter based resonant DAB converter that requires only a single-stage power conversion process to facilitate isolated bi-directional power transfer between EVs and the grid. The proposed converter comprises a matrix converter based front end linked with an EV side full-bridge converter through a high frequency isolation transformer and a tuned LCL network. A mathematical model, which predicts the behavior of the proposed system, is presented to show that both the magnitude and direction of the power flow can be controlled through either relative phase angle or magnitude modulation of voltages produced by converters. Viability of the proposed concept is verified through simulations. The proposed matrix converter based DAB, with a single power conversion stage, is low in cost, and suites charging and discharging in single or multiple EVs or V2G applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A switching control strategy is proposed for current-fed half-bridge converters. An active switch based voltage doubler circuit at the secondary side of the isolation transformer is used to obtain zero-current-switching at turn-off and zero-voltage-switching at turn-on in the primary side switches of the current-fed half-bridge converter. The operation of the current-fed half-bridge converter with the proposed switching control strategy is explained using the equivalent circuit during each sub-interval of operation. The operation of the current-fed halfbridge converter is simulated using MATLAB/Simpower and PSIM to verify the feasibility of the switching control strategy. Experimental results are provided to validate the converter's operation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Z-source inverter based grid-interface for a variable-speed wind turbine connected to a permanent magnet synchronous generator is proposed. A control system is designed to harvest maximum wind energy under varied wind conditions with the use of the permanent magnet synchronous generator, diode-rectifier and Z-source inverter. Control systems for speed regulation of the generator and for DC- and AC- sides of the Z-source inverter are investigated using computer simulations and laboratory experiments. Simulation and experimental results verify the efficacy of the proposed approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Typical wireless power transfer systems utilize series compensation circuit which is based on magnetic coupling and resonance principles that was first developed by Tesla. However, changes in coupling caused by gap distance, alignment and orientation variations can lead to reduce power transfer efficiencies and the transferred power levels. This paper proposes impedance matched circuit to reduce frequency bifurcation effect and improve on the transferred power level, efficiency and total harmonic distortion (THD) performance of the series compensation circuit. A comprehensive mathematical analysis is performed for both series and impedance matched circuits to show the frequency bifurcation effects in terms of input impedance, variations in transferred power levels and efficiencies. Matlab/Simulink results validate the theoretical analysis and shows the circuits’ THD performance when circuits are fed with power electronic converters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a novel modulation strategy for a phase controlled Capacitor-Inductor-Capacitor (CLC) Resonant Dual Active Bridge (RDAB). The proposed modulation strategy improves the soft turn-on, Zero-Current-Switching (ZCS) and Zero-Voltage-Switching (ZVS) range of the converter while only minimally increasing the required reactive currents in the ac link. A mathematical analysis of the proposed modulation scheme is presented along with a theoretical loss comparison between several modulation strategies. The proposed modulation strategy was implemented and the experimental results are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple, low-cost, constant frequency, analog controller is proposed for the front-end half-bridge rectifier of a single-phase transformerless UPS system to maintain near unity power factor at the input and zero dc-offset voltage at the output. The controller generates the required gating pulses by comparing the input current with a periodic, bipolar, linear carrier without sensing the input voltage. Two voltage controllers and a single integrator with reset are used to generate the required carrier. All the necessary control operations can be performed without using any PLL, multiplier and/or divider. The controller can be fabricated as a single integrated circuit. The control concept is validated through simulation and also experimentally on an 800W half-bridge rectifier. Experimental results are presented for ac-dc application, and also for ac-dc-ac UPS application with both sinusoidal and nonlinear loads. The simulation and experimental results agree well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new approach to the power flow analysis in steady state for multiterminal DC-AC systems. A flexible and practical choice of per unit system is used to formulate the DC network and converter equations. A converter is represented by Norton's equivalent of a current source in parallel with the commutation resistance. Unlike in previous literature, the DC network equations are used to derive the controller equations for the DC system using a subset of specifications. The specifications considered are current or power at all terminals except the slack terminal where the DC voltage is specified. The control equations are solved by Newton's method, using the current injections at the converter terminals as state variables. Further, a systematic approach to the handling of constraints is proposed by identifying the priorities in rescheduling of the specified variables. The methodology is illustrated by example of a 5 terminal DC system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Piezoelectric-device-based vibration energy harvesting requires a rectifier for conversion of input ac to usable dc form. Power loss due to diode drop in rectifier is a significant fraction of the already low levels of harvested power. The proposed circuit is a low-drop-diode equivalent, which mimics a diode using linear region-operated MOSFET. The proposed diode equivalent is powered directly from input signal and requires no additional power supply for its control. Power used by the control circuit is kept at a bare minimum to have an overall output power improvement. Diode equivalent was used to replace the four diodes in a full-wave bridge rectifier, which is the basic full- wave rectifier and is a part of the more advanced rectifiers like switch-only and bias-flip rectifiers. Simulation in 130-nm technology and experiment with discrete components show that a bridge rectifier with the proposed diode provides a 30-169% increase in output power extracted from piezoelectric device, as compared to a bridge rectifier with diode-connected MOSFETs. The bridge rectifier with the proposed diode can extract 90% of the maximum available power from an ideal piezoelectric device-bridge rectifier circuit. Setting aside the constraint of power loss, simulations indicate that diode drop as low as 10 mV at 38 mu A can be achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A power filter is necessary to connect the output of a power converter to the grid so as to reduce the harmonic distortion introduced in the line current and voltage by the power converter. Many a times, a transformer is also present before the point of common coupling. Magnetic components often constitute a significant part of the overall weight, size and cost of the grid interface scheme. So, a compact inexpensive design is desirable. A higher-order LCL-filter and a transformer are increasingly being considered for grid interconnection of the power converter. This study proposes a design method based on a three-winding transformer, that generates an integrated structure that behaves as an LCL-filter, with both the filter inductances and the transformer that are merged into a single electromagnetic component. The parameters of the transformer are derived analytically. It is shown that along with a filter capacitor, the transformer parameters provide the filtering action of an LCL-filter. A single-phase full-bridge power converter is operated as a static compensator for performance evaluation of the integrated filter transformer. A resonant integrator-based single-phase phase locked loop and stationary frame AC current controller are employed for grid frequency synchronisation and line current control, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design of a start up power circuit for a control power supply (CPS) which feeds power to the sub-systems of High Power Converters (HPC). The sub-systems such as gate drive card, annunciation card, protection and delay card etc; needs to be provided power for the operation of a HPC. The control power supply (CPS) is designed to operate over a wide range of input voltage from 90Vac to 270Vac. The CPS output supplies power at a desired voltage of Vout =24V to the auxiliary sub-systems of the HPC. During the starting, the power supply to the control circuitry of CPS in turn, is obtained using a separate start-up power supply. This paper discusses the various design issues of the start-up power circuit to ensure that start-up and shut down of the CPS occurs reliably. The CPS also maintains the power factor close to unity and low total harmonic distortion in input current. The paper also provides design details of gate drive circuits employed for the CPS as well as the design of on-board power supply for the CPS. Index terms: control power supply, start-up power supply, DSFC, pre-regulator

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is a study of Multilevel Sinusoidal Pulse Width Modulation (MSPWM) methods; Phase Disposition (PD), Alternate Phase Opposition Disposition (APOD), Phase Opposition Disposition (POD) on a single phase Cascaded H-Bridge Multilevel inverter. Various factors such as amplitude modulation index (Ma), frequency modulation index (M-f), phase angle between carrier and reference modulating wave (phi) have been considered for simulation. Variation in these factors and their effect on inverter performance is evaluated. Factors such as DC bus utilization, output r.m.s voltage, total harmonic distortion (%THD), dominant harmonic order, switching losses are evaluated based on simulation results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Climate change is arguably the most critical issue facing our generation and the next. As we move towards a sustainable future, the grid is rapidly evolving with the integration of more and more renewable energy resources and the emergence of electric vehicles. In particular, large scale adoption of residential and commercial solar photovoltaics (PV) plants is completely changing the traditional slowly-varying unidirectional power flow nature of distribution systems. High share of intermittent renewables pose several technical challenges, including voltage and frequency control. But along with these challenges, renewable generators also bring with them millions of new DC-AC inverter controllers each year. These fast power electronic devices can provide an unprecedented opportunity to increase energy efficiency and improve power quality, if combined with well-designed inverter control algorithms. The main goal of this dissertation is to develop scalable power flow optimization and control methods that achieve system-wide efficiency, reliability, and robustness for power distribution networks of future with high penetration of distributed inverter-based renewable generators.

Proposed solutions to power flow control problems in the literature range from fully centralized to fully local ones. In this thesis, we will focus on the two ends of this spectrum. In the first half of this thesis (chapters 2 and 3), we seek optimal solutions to voltage control problems provided a centralized architecture with complete information. These solutions are particularly important for better understanding the overall system behavior and can serve as a benchmark to compare the performance of other control methods against. To this end, we first propose a branch flow model (BFM) for the analysis and optimization of radial and meshed networks. This model leads to a new approach to solve optimal power flow (OPF) problems using a two step relaxation procedure, which has proven to be both reliable and computationally efficient in dealing with the non-convexity of power flow equations in radial and weakly-meshed distribution networks. We will then apply the results to fast time- scale inverter var control problem and evaluate the performance on real-world circuits in Southern California Edison’s service territory.

The second half (chapters 4 and 5), however, is dedicated to study local control approaches, as they are the only options available for immediate implementation on today’s distribution networks that lack sufficient monitoring and communication infrastructure. In particular, we will follow a reverse and forward engineering approach to study the recently proposed piecewise linear volt/var control curves. It is the aim of this dissertation to tackle some key problems in these two areas and contribute by providing rigorous theoretical basis for future work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold crucible furnace is widely used for melting reactive metals for high quality castings. Although the water cooled copper crucible avoids contamination, it produces a low superheat of the melt. Experimental and theoretical investigations of the process showed that the increase of the supplied power to the furnace leads to a saturation in the temperature rise of the melt, and no significant increase of the melt superheat can be obtained. The computer model of theprocess has been developed to simulate the time dependent turbulent flow, heat transfer with phase change, and AC and DC magnetohydrodynamics in a time varying liquid metal envelope. The model predicts that the supermimposition of a strong DC field on top of the normal AC field reduces the level of turbulience and stirring in the liquid metal, thereby reducing the heat loss through the base of the crucible and increasing the superheat. The direct measurements of the temperature in the commercial size cold crucbile has confirmed the computer redictions and showed that the addition of a DC field increased the superheat in molten TiAl from ~45C (AC field only) to ~81C (DC+AC fields). The present paper reports further predictions of the effect of a dDC field on top of the AC field and compares these with experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Salient pole brushless alternators coupled to IC engines are extensively used as stand-by power supply units for meeting in- dustrial power demands. Design of such generators demands high power to weight ratio, high e ciency and low cost per KVA out- put. Moreover, the performance characteristics of such machines like voltage regulation and short circuit ratio (SCR) are critical when these machines are put into parallel operation and alterna- tors for critical applications like defence and aerospace demand very low harmonic content in the output voltage. While designing such alternators, accurate prediction of machine characteristics, including total harmonic distortion (THD) is essential to mini- mize development cost and time. Total harmonic distortion in the output voltage of alternators should be as low as possible especially when powering very sophis- ticated and critical applications. The output voltage waveform of a practical AC generator is replica of the space distribution of the ux density in the air gap and several factors such as shape of the rotor pole face, core saturation, slotting and style of coil disposition make the realization of a sinusoidal air gap ux wave impossible. These ux harmonics introduce undesirable e ects on the alternator performance like high neutral current due to triplen harmonics, voltage distortion, noise, vibration, excessive heating and also extra losses resulting in poor e ciency, which in turn necessitate de-rating of the machine especially when connected to non-linear loads. As an important control unit of brushless alternator, the excitation system and its dynamic performance has a direct impact on alternator's stability and reliability. The thesis explores design and implementation of an excitation i system utilizing third harmonic ux in the air gap of brushless al- ternators, using an additional auxiliary winding, wound for 1=3rd pole pitch, embedded into the stator slots and electrically iso- lated from the main winding. In the third harmonic excitation system, the combined e ect of two auxiliary windings, one with 2=3rd pitch and another third harmonic winding with 1=3rd pitch, are used to ensure good voltage regulation without an electronic automatic voltage regulator (AVR) and also reduces the total harmonic content in the output voltage, cost e ectively. The design of the third harmonic winding by analytic methods demands accurate calculation of third harmonic ux density in the air gap of the machine. However, precise estimation of the amplitude of third harmonic ux in the air gap of a machine by conventional design procedures is di cult due to complex geome- try of the machine and non-linear characteristics of the magnetic materials. As such, prediction of the eld parameters by conven- tional design methods is unreliable and hence virtual prototyping of the machine is done to enable accurate design of the third har- monic excitation system. In the design and development cycle of electrical machines, it is recognized that the use of analytical and experimental methods followed by expensive and in exible prototyping is time consum- ing and no longer cost e ective. Due to advancements in com- putational capabilities over recent years, nite element method (FEM) based virtual prototyping has become an attractive al- ternative to well established semi-analytical and empirical design methods as well as to the still popular trial and error approach followed by the costly and time consuming prototyping. Hence, by virtually prototyping the alternator using FEM, the important performance characteristics of the machine are predicted. Design of third harmonic excitation system is done with the help of results obtained from virtual prototype of the machine. Third harmonic excitation (THE) system is implemented in a 45 KVA ii experimental machine and experiments are conducted to validate the simulation results. Simulation and experimental results show that by utilizing third harmonic ux in the air gap of the ma- chine for excitation purposes during loaded conditions, triplen harmonic content in the output phase voltage is signi cantly re- duced. The prototype machine with third harmonic excitation system designed and developed based on FEM analysis proved to be economical due to its simplicity and has the added advan- tage of reduced harmonics in the output phase voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an analysis of a novel pulse-width-modulated (PWM) voltage step-down/up Zeta converter, featuring zero-current-switching (ZCS) at the active switches. The applications in de to de and ac to de (rectifier) operation modes are used as examples to illustrate the performance of this new ZCS-PWM Zeta converter. Regarding to the new ZCS-PWM Zeta rectifier proposed, it should be noticed that the average-current mode control is used in order to obtain a structure with high power-factor (HPF) and low total harmonic distortion (THD) at the input current.Two active switches (main and auxiliary transistors), two diodes, two small resonant inductors and one small resonant capacitor compose the novel ZCS-PWM soft-commutation cell, used in these new ZCS-PWM Zeta converters. In this cell, the turn-on of the active switches occurs in zero-current (ZC) and their turn-off in zero-current and zero-voltage (ZCZV). For the diodes, their turn-on process occurs in zero-voltage (ZV) and their reverse-recovery effects over the active switches are negligible. These characteristics make this cell suitable for Insulated-Gate Bipolar Transistors (IGBTs) applications.The main advantages of these new Zeta converters, generated from the new soft-commutation cell proposed, are possibility of obtaining isolation (through their accumulation inductors), and high efficiency, at wide load range. In addition, for the rectifier application, a high power factor and low THD in the input current ran be obtained, in agreement with LEC 1000-3-2 standards.The principle of operation, the theoretical analysis and a design example for the new de to de Zeta converter operating in voltage step-down mode are presented. Experimental results are obtained from a test unit with 500W output power, 110V(dc) output voltage, 220V(dc) input voltage, operating at 50kHz switching frequency. The efficiency measured at rated toad is equal to 97.3%for this new Zeta converter.Finally, the new Zeta rectifier is analyzed, and experimental results from a test unit rated at 500W output power, 110V(dc) output voltage, 220V(rms) input voltage, and operating at 50kHz switching frequency, are presented. The measured efficiency is equal to 96.95%, the power-factor is equal to 0.98, and the input current THD is equal to 19.07%, for this new rectifier operating at rated load.