967 resultados para bandwidth 2.0 GHz to 2.45 GHz


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atmospheric fluxes of iron (Fe) over the past 200 kyr are reported for the coastal Antarctic Talos Dome ice core, based on acid leachable Fe concentrations. Fluxes of Fe to Talos Dome were consistently greater than those at Dome C, with the greatest difference observed during interglacial climates. We observe different Fe flux trends at Dome C and Talos Dome during the deglaciation and early Holocene, attributed to a combination of deglacial activation of dust sources local to Talos Dome and the reorganisation of atmospheric transport pathways with the retreat of the Ross Sea ice shelf. This supports similar findings based on dust particle sizes and fluxes and Rare Earth Element fluxes. We show that Ca and Fe should not be used as quantitative proxies for mineral dust, as they all demonstrate different deglacial trends at Talos Dome and Dome C. Considering that a 20 ppmv decrease in atmospheric CO2 at the coldest part of the last glacial maximum occurs contemporaneously with the period of greatest Fe and dust flux to Antarctica, we confirm that the maximum contribution of aeolian dust deposition to Southern Ocean sequestration of atmospheric CO2 is approximately 20 ppmv.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lithology describes the geochemical, mineralogical, and physical properties of rocks. It plays a key role in many processes at the Earth surface, especially the fluxes of matter to soils, ecosystems, rivers, and oceans. Understanding these processes at the global scale requires a high resolution description of lithology. A new high resolution global lithological map (GLiM) was assembled from existing regional geological maps translated into lithological information with the help of regional literature. The GLiM represents the rock types of the Earth surface using 1,235,400 polygons. The lithological classification consists of three levels. The first level contains 16 lithological classes comparable to previously applied definitions in global lithological maps. The additional two levels contain 12 and 14 subclasses, respectively, which describe more specific rock attributes. According to the GLiM, the Earth is covered by 64 % sediments (a third of which is carbonates), 13 % metamorphics, 7 % plutonics, and 6 % volcanics, and 10% are covered by water or ice. The high resolution of the GLiM allows observation of regional lithological distributions which often vary from the global average. The GLiM enables regional analysis of Earth surface processes at global scales.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter was previously intended to trace volcanic episodes through the Neogene and Pleistocene geological history recorded in the sedimentary sections drilled on the Emperor seamounts. Drilling disturbance, poor core recovery, and incomplete stratigraphic sections recovered from the seamounts have frustrated that plan, however. Moreover, the Leg 55 sedimentologists found in their smear-slide studies that transported island-arc tephra is scarce in the sediments, if present at all. So we have restricted our objective to description of the volcaniclastic admixture in sediments, as determined by mineralogical and geochemical data. We studied geochemistry of bulk samples (see Murdmaa et al., 1980), coarse-fraction mineralogy, and additional smear slides. The results obtained, however, do not tell much more about the volcaniclastic matter than did shipboard core descriptions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Top-Hat hot electron light emission and lasing in semiconductor heterostructure (HELLISH)-vertical cavity semiconductor optical amplifier (VCSOA) is a modified version of a HELLISH-VCSOA device. It has a shorter p-channel and longer n-channel. The device studied in this work consists of a simple GaAs p-i-n junction, containing 11 Ga0.35In0.65 N0.02As0.08/GaAs multiple quantum wells in its intrinsic region; the active region is enclosed between six pairs of GaAs/AlAs top distributed Bragg reflector (DBR) mirrors and 20.5 pairs of AlAs/GaAs bottom DBR mirrors. The operation of the device is based on longitudinal current transport parallel to the layers of the GaAs p-n junction. The device is characterised through I-V-L and by spectral photoluminescence, electroluminescence and electro-photoluminescence measurements. An amplification of about 25 dB is observed at applied voltages of around V = 88 V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transient simulations are widely used in studying the past climate as they provide better comparison with any exisiting proxy data. However, multi-millennial transient simulations using coupled climate models are usually computationally very expensive. As a result several acceleration techniques are implemented when using numerical simulations to recreate past climate. In this study, we compare the results from transient simulations of the present and the last interglacial with and without acceleration of the orbital forcing, using the comprehensive coupled climate model CCSM3 (Community Climate System Model 3). Our study shows that in low-latitude regions, the simulation of long-term variations in interglacial surface climate is not significantly affected by the use of the acceleration technique (with an acceleration factor of 10) and hence, large-scale model-data comparison of surface variables is not hampered. However, in high-latitude regions where the surface climate has a direct connection to the deep ocean, e.g. in the Southern Ocean or the Nordic Seas, acceleration-induced biases in sea-surface temperature evolution may occur with potential influence on the dynamics of the overlying atmosphere. The data provided here are from both accelerated and non-accelerated runs as decadal mean values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Evidence suggests that the rate of recurrent headache after treatment of migraine in the emergency department (ED) is high. The mechanisms for this are unclear, but neurogenic inflammation may play a role. There is conflicting evidence about whether adjuvant dexamethasone reduces the rate of recurrent headache. The aim of this study was to compare the rate of recurrent headache in patients with migraine randomised to receive a single dose of oral dexamethasone or placebo at discharge after treatment in the ED with intravenous phenothiazine.

METHODS: A double-blind, randomised, placebo-controlled trial was conducted in the ED of three community teaching hospitals. Adult patients with physician-diagnosed migraine were treated with intravenous phenothiazine and at discharge were randomised to receive either 8 mg oral dexamethasone or placebo as a single dose. Follow-up was by telephone at 48-72 h and the proportion of patients with recurrent headache overall and in the subgroup with headache duration <24 h was recorded.

RESULTS: 63 patients (76% women) of median age 39 years were enrolled, 61 of whom (97%) completed follow-up. The pooled rate of recurrent headache was 33%. 32 were randomised to placebo and 31 to dexamethasone. The rate of recurrent headache in the dexamethasone and control groups was 27% (8/30) vs 39% (12/31) (relative risk (RR) 0.69, 95% CI 0.33 to 1.45, p = 0.47). For 40 patients with headache lasting <24 h the rate of recurrent headache in the dexamethasone and control groups was 15% (3/20) vs 45% (9/20), a reduction in absolute risk of 30% (RR 0.33, 95% CI 0.11 to 1.05, p = 0.08).

CONCLUSION: A single oral dose of dexamethasone following phenothiazine treatment for migraine in the ED did not reduce the rate of recurrent headache. There is weak evidence for a possible benefit in the subgroup who present within <24 h of symptom onset. A multicentre trial to confirm this finding is warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new dynamic regime in a multisegmented AlGaAs/GaAs DH injection laser has been realised. Generation of bandwidth-limited 100 GHz repetition rate pulses has been demonstrated. This value is claimed to be the largest ever reported for an ultrashort pulse repetition frequency obtained directly from a laser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper details the implementation and operational performance of a minimum-power 2.45-GHz pulse receiver and a companion on-off keyed transmitter for use in a semi-active duplex RF biomedical transponder. A 50-Ohm microstrip stub-matched zero-bias diode detector forms the heart of a body-worn receiver that has a CMOS baseband amplifier consuming 20 microamps from +3 V and achieves a tangential sensitivity of -53 dBm. The base transmitter generates 0.5 W of peak RF output power into 50 Ohms. Both linear and right-hand circularly polarized Tx-Rx antenna sets were employed in system reliability trials carried out in a hospital Coronary Care Unit, For transmitting antenna heights between 0.3 and 2.2 m above floor level, transponder interrogations were 95% reliable within the 67-m-sq area of the ward, falling to an average of 46 % in the surrounding rooms and corridors. Overall, the circular antenna set gave the higher reliability and lower propagation power decay index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High microwave susceptibility of NaH2PO4 . 2H(2)O has been discovered, This hydrated acid phosphate of sodium can be heated upto 1000 K or more when exposed to 2.45 GHz microwaves. Using this, a novel microwave-assisted preparation of a number of important crystalline and glassy materials with NASICON-type chemistry has been accomplished in less than 8 min which is only a fraction of the time required for conventional synthetic procedures, The present single-shot approach to the preparation of phosphates is attractive in terms of its simplicity, rapidity, and general applicability, A ''step-ladder'' heating mechanism has been proposed to account for the high microwave absorbing ability of NaH2PO4 . 2H(2)O.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cross sections for the two antiproton-proton annihilation-in-flight modes,

ˉp + p → π+ + π-

ˉp + p → k+ + k-

were measured for fifteen laboratory antiproton beam momenta ranging from 0.72 to 2.62 GeV/c. No magnets were used to determine the charges in the final state. As a result, the angular distributions were obtained in the form [dσ/dΩ (ΘC.M.) + dσ/dΩ (π – ΘC.M.)] for 45 ≲ ΘC.M. ≲ 135°.

A hodoscope-counter system was used to discriminate against events with final states having more than two particles and antiproton-proton elastic scattering events. One spark chamber was used to record the track of each of the two charged final particles. A total of about 40,000 pictures were taken. The events were analyzed by measuring the laboratory angle of the track in each chamber. The value of the square of the mass of the final particles was calculated for each event assuming the reaction

ˉp + p → a pair of particles with equal masses.

About 20,000 events were found to be either annihilation into π ±-pair or k ±-pair events. The two different charged meson pair modes were also distinctly separated.

The average differential cross section of ˉp + p → π+ + π- varied from ~ 25 µb/sr at antiproton beam momentum 0.72 GeV/c (total energy in center-of-mass system, √s = 2.0 GeV) to ~ 2 µb/sr at beam momentum 2.62 GeV/c (√s = 2.64 GeV). The most striking feature in the angular distribution was a peak at ΘC.M. = 90° (cos ΘC.M. = 0) which increased with √s and reached a maximum at √s ~ 2.1 GeV (beam momentum ~ 1.1 GeV/c). Then it diminished and seemed to disappear completely at √s ~ 2.5 GeV (beam momentum ~ 2.13 GeV/c). A valley in the angular distribution occurred at cos ΘC.M. ≈ 0.4. The differential cross section then increased as cos ΘC.M. approached 1.

The average differential cross section for ˉp + p → k+ + k- was about one third of that of the π±-pair mode throughout the energy range of this experiment. At the lower energies, the angular distribution, unlike that of the π±-pair mode, was quite isotropic. However, a peak at ΘC.M. = 90° seemed to develop at √s ~ 2.37 GeV (antiproton beam momentum ~ 1.82 GeV/c). No observable change was seen at that energy in the π±-pair cross section.

The possible connection of these features with the observed meson resonances at 2.2 GeV and 2.38 GeV, and its implications, were discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a W-band high-resolution radar sensor for short-range applications. Low-cost technologies have been properly selected in order to implement a versatile and easily scalable radar system. A large operational bandwidth of 9 GHz, required for obtaining high-range resolution, is attained by means of a frequency multiplication-based architecture. The system characterization to identify the performance-limiting stages and the subsequent design optimization are presented. The assessment of system performance for several representative applications has been carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tension banding castration of cattle is gaining favour because it is relatively simple to perform and is promoted by retailers of the banders as a humane castration method. Two experiments were conducted, under tropical conditions using Bos indicus bulls comparing tension banding (Band) and surgical (Surgical) castration of weaner (7–10 months old) and mature (22–25 months old) bulls with and without pain management (NSAID (ketoprofen) or saline injected intramuscularly immediately prior to castration). Welfare outcomes were assessed using a range of measures; this paper reports on some physiological, morbidity and productivity-related responses to augment the behavioural responses reported in an accompanying paper. Blood samples were taken on the day of castration (day 0) at the time of restraint (0 min) and 30 min (weaners) or 40 min (mature bulls), 2 h, and 7 h; and days 1, 2, 3, 7, 14, 21 and 28 post-castration. Plasmas from day 0 were assayed for cortisol, creatine kinase, total protein and packed cell volume. Plasmas from the other samples were assayed for cortisol and haptoglobin (plus the 0 min sample). Liveweights were recorded approximately weekly to 6 weeks and at 2 and 3 months post-castration. Castration sites were checked at these same times to 2 months post-castration to score the extent of healing and presence of sepsis. Cortisol concentrations (mean ± s.e. nmol/L) were significantly (P < 0.05) higher in the Band (67 ± 4.5) compared with Surgical weaners (42 ± 4.5) at 2 h post-castration, but at 24 h post-castration were greater in the Surgical (43 ± 3.2) compared with the Band weaners (30 ± 3.2). The main effect of ketoprofen was on the cortisol concentrations of the mature Surgical bulls; concentrations were significantly reduced at 40 min (47 ± 7.2 vs. 71 ± 7.2 nmol/L for saline) and 2 h post-castration (24 ± 7.2, vs. 87 ± 7.2 nmol/L for saline). Ketoprofen, however, had no effect on the Band mature bulls, with their cortisol concentrations averaging 54 ± 5.1 nmol/L at 40 min and 92 ± 5.1 nmol/L at 2 h. Cortisol concentrations were also significantly elevated in the Band (83 ± 3.0 nmol/L) compared with Surgical mature bulls (57 ± 3.0 nmol/L) at weeks 2–4 post-castration. The timing of this elevation coincided with significantly elevated haptoglobin concentrations (mg/mL) in the Band bulls (2.97 ± 0.102 for mature bulls and 1.71 ± 0.025 for weaners, vs. 2.10 ± 0.102 and 1.45 ± 0.025 respectively for the Surgical treatment) and evidence of slow wound healing and sepsis in both the weaner (0.81 ± 0.089 not healed at week 4 for Band, 0.13 ± 0.078 for Surgical) and mature bulls (0.81 ± 0.090 at week 4 for Band, 0.38 ± 0.104 for Surgical). Overall, liveweight gains of both age groups were not affected by castration method. The findings of acute pain, chronic inflammation and possibly chronic pain in the mature bulls at least, together with poor wound healing in the Band bulls support behavioural findings reported in the accompanying paper and demonstrate that tension banding produces inferior welfare outcomes for weaner and mature bulls compared with surgical castration.