512 resultados para anaesthesia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skunks are becoming increasingly popular as pets. As such, they often undergo a variety of surgical procedures. Two pet skunks undergoing a dermatological examination, including skin biopsy, were anaesthetised with a combination of dexmedetomidine (0.02 mg/kg), butorphanol (0.3 mg/kg), and alfaxalone (4 mg/kg), all administered intramuscularly. Anaesthesia was characterised by rapid onset, absence of detectable side effects and fast recovery after atipamezole administration. Biopsies and toe-pinch did not elicit cardiorespiratory responses, nor did it result in movements or lightening of the anaesthetic depth. Both skunks recovered uneventfully, and showed normal appetite and regular defecation within eight hours following surgery. However, both the animals experienced mild hypothermia at recovery. The dexmedetomidine-alfaxalone-butorphanol combination produced satisfactory anaesthesia in the two skunks, object of this report. This anaesthetic protocol may be used in this species to provide immobility, myorelaxation, unconsciousness and analgesia during skin biopsy or other minor surgical procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare isoflurane alone or in combination with systemic ketamine and lidocaine for general anaesthesia in horses. STUDY DESIGN Prospective, randomized, blinded clinical trial. ANIMALS Forty horses (ASA I-III) undergoing elective surgery. METHODS Horses were assigned to receive isoflurane anaesthesia alone (ISO) or with ketamine and lidocaine (LKI). After receiving romifidine, diazepam, and ketamine, the isoflurane end-tidal concentration was set at 1.3% and subsequently adjusted by the anaesthetist (unaware of treatments) to maintain a light plane of surgical anaesthesia. Animals in the LKI group received lidocaine (1.5 mg kg(-1) over 10 minutes, followed by 40 microg kg(-1) minute(-1)) and ketamine (60 microg kg(-1) minute(-1)), both reduced to 65% of the initial dose after 50 minutes, and stopped 15 minutes before the end of anaesthesia. Standard clinical cardiovascular and respiratory parameters were monitored. Recovery quality was scored from one (very good) to five (very poor). Differences between ISO and LKI groups were analysed with a two-sample t-test for parametric data or a Fischer's exact test for proportions (p < 0.05 for significance). Results are mean +/- SD. RESULTS Heart rate was lower (p = 0.001) for LKI (29 +/- 4) than for ISO (34 +/- 6). End-tidal concentrations of isoflurane (ISO: 1.57% +/- 0.22; LKI: 0.97% +/- 0.33), the number of horses requiring thiopental (ISO: 10; LKI: 2) or dobutamine (ISO:8; LKI:3), and dobutamine infusion rates (ISO:0.26 +/- 0.09; LKI:0.18 +/- 0.06 microg kg(-1) minute(-1)) were significantly lower in LKI compared to the ISO group (p < 0.001). No other significant differences were found, including recovery scores. CONCLUSIONS AND CLINICAL RELEVANCE These results support the use of lidocaine and ketamine to improve anaesthetic and cardiovascular stability during isoflurane anaesthesia lasting up to 2 hours in mechanically ventilated horses, with comparable quality of recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Typewritten.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliographical references and index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the phenomenon of system tailoring in the context of data from an observational study of anaesthesia. We found that anaesthetists tailor their monitoring equipment so that the auditory alarms are more informative. However, the occurrence of tailoring by anaesthetists in the operating theatre was infrequent, even though the flexibility to tailor exists on many of the patient monitoring systems used in the study. We present an influence diagram to explain how alarm tailoring can increase situation awareness in the operating theatre but why factors inhibiting tailoring prevent widespread use. Extending the influence diagram, we discuss ways that more informative displays could achieve the results sought by anaesthetists when they tailor their alarm systems. In particular, we argue that we should improve our designs rather than simply provide more flexible tailoring systems. because users often find tailoring a complex task. We conclude that properly designed auditory displays may benefit anaesthetists in achieving greater patient situation awareness and that designers should consider carefully how factors promoting and inhibiting tailoring will affect the end-users' likelihood of conducting tailoring. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the effect of no music, classical music or rock music on simulated patient monitoring. Twenty-four non-anaesthetist participants with high or low levels of musical training were trained to monitor visual and auditory displays of patients' vital signs. In nine anaesthesia test scenarios, participants were asked every 50-70 s whether one of five vital signs was abnormal and the trend of its direction. Abnormality judgements were unaffected by music or musical training. Trend judgements were more accurate when music was playing (p = 0.0004). Musical participants reported trends more accurately (p = 0.004), and non-musical participants tended to benefit more from music than did the musical participants (p = 0.063). Music may provide a pitch and rhythm standard from which participants can judge changes in vital signs from auditory displays. Nonetheless, both groups reported that it was easier to monitor the patient with no music (p = 0.0001), and easier to rely upon the auditory displays with no music (p = 0.014).