927 resultados para Voice detectors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Cairn Reisch Continuing Education Legislation introduced volunteer coordinators assigned to regions Recruitment & marketing survey

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Melanie Kempf volunteer Ombudsman Program facts Continuing Education Free educational events

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Pam Railsback Continuing Education Iowa by the numbers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tips for Effectiveness Continuing Education Amazing Village Designed for People with Dementia Helpful Resources

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Julie Pollock Continuing Education Consumer Voice Fact Sheet - What is Financial Exploitation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Meredith Funke, AmericCorps VISTA Continuing Education New Resources for volunteers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Kim Cooper Person-Centered Matters: Making Life Better for Someone Living with Dementia Continuing Education New Resources for Volunteers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voter Rights Continuing Education

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight: Cindy Pederson Continuing Education National volunteer Month Wrap-Up Events & Conferences Peer Group Meetings Training Refresher Articles, Websites & Videos May is Older Americans Month

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spotlight on Merea Bentrott Continuing Education VOP Communiques VOP Trivia Ombudsman Tidbit

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.