997 resultados para Visual scores


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and effective demonstration to help students comprehend phase diagrams and understand phase equilibria and transformations is created using common chemical solvents available in the laboratory. Common misconceptions surrounding phase diagram operations, such as components versus phases, reversibility of phase transformations, and the lever rule are addressed. Three different binary liquid mixtures of varying compatibility create contrastive phase equilibrium cases, where colorful dyes selectively dissolved in each of corresponding phases allow for quick and unambiguous perceptions of solubility limit and phase transformations. Direct feedback and test scores from a group of students show evidence of the effectiveness of the visual and active teaching tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here we present the development of a visual evaluation system for routine assessment of in vitro-engineered cartilaginous tissue. Neocartilage was produced by culturing human articular chondrocytes in pellet culture systems or in a scaffold-free bioreactor system. All engineered tissues were embedded in paraffin and were sectioned and stained with Safranin O-fast green. The evaluation of each sample was broken into 3 categories (uniformity and intensity of Safranin O stain, distance between cells/amount of matrix produced, and cell morphology), and each category had 4 components with a score ranging from 0 to 3. Three observers evaluated each sample, and the new system was independently tested against an objective computer-based histomorphometry system. Pellets were also assessed biochemically for glycosaminoglycan (GAG) content. Pellet histology scores correlated significantly with GAG contents and were in agreement with the computer-based histomorphometry system. This system allows a valid and rapid assessment of in vitro-generated cartilaginous tissue that has a relevant association with objective parameters indicative of cartilage quality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Visuoperceptual deficits are common in dementia with Lewy bodies (DLB) and Alzheimer disease (AD). Testing visuoperception in dementia is complicated by decline in other cognitive domains and extrapyramidal features. To overcome these issues, we developed a computerized test, the Newcastle visuoperception battery (NEVIP), which is independent of motor function and has minimal cognitive load.We aimed to test its utility to identify visuoperceptual deficits in people with dementia. PARTICIPANTS AND MEASUREMENTS We recruited 28 AD and 26 DLB participants with 35 comparison participants of similar age and education. The NEVIP was used to test angle, color, and form discrimination along with motion perception to obtain a composite visuoperception score. RESULTS Those with DLB performed significantly worse than AD participants on the composite visuoperception score (Mann-Whitney U = 142, p = 0.01). Visuoperceptual deficits (defined as 2 SD below the performance of comparisons) were present in 71% of the DLB group and 40% of the AD group. Performance was not significantly correlated with motor impairment, but was significantly related to global cognitive impairment in DLB (rs = -0.689, p <0.001), but not in AD. CONCLUSION Visuoperceptual deficits can be detected in both DLB and AD participants using the NEVIP, with the DLB group performing significantly worse than AD. Visuoperception scores obtained by the NEVIP are independent of participant motor deficits and participants are able to comprehend and perform the tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Parkinson disease dementia (PDD) and dementia with Lewy bodies (DLB) have overlapping clinical and pathologic features. Recurrent visual hallucinations (RVH) are common in both disorders. The authors have compared details of hallucination characteristics and associated neuropsychiatric features in DLB and PDD. METHODS This is a descriptive, cross-sectional study using the Institute of Psychiatry Visual Hallucinations Interview (IP-VHI) to explore self-reported frequency, duration, and phenomenology of RVH in PDD and DLB. The caregivers' ratings of hallucinations and other neuropsychiatric features were elicited with the Neuropsychiatric Inventory (NPI). RESULTS Fifty-six patients (35 PDD; 21 DLB) with RVH were assessed. Hallucination characteristics were similar in both disorders. Simple hallucinations were rare. Most patients experienced complex hallucinations daily, normally lasting minutes. They commonly saw people or animals and the experiences were usually perceived as unpleasant. NPI anxiety scores were higher in PDD. Neuropsychiatric symptoms coexisting with hallucinations were apathy, sleep disturbance, and anxiety. CONCLUSIONS Patients with mild to moderate dementia can provide detailed information about their hallucinations. Characteristics of RVH were similar in PDD and DLB, and phenomenology suggests the involvement of dorsal and ventral visual pathways in their generation. The coexistence of RVH with anxiety, apathy, and sleep disturbance is likely to impair patients' quality of life and may have treatment implications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To quantify visual discrimination, space-motion, and object-form perception in patients with Parkinson disease dementia (PDD), dementia with Lewy bodies (DLB), and Alzheimer disease (AD). METHODS The authors used a cross-sectional study to compare three demented groups matched for overall dementia severity (PDD: n = 24; DLB: n = 20; AD: n = 23) and two age-, sex-, and education-matched control groups (PD: n = 24, normal controls [NC]: n = 25). RESULTS Visual perception was globally more impaired in PDD than in nondemented controls (NC, PD), but was not different from DLB. Compared to AD, PDD patients tended to perform worse in all perceptual scores. Visual perception of patients with PDD/DLB and visual hallucinations was significantly worse than in patients without hallucinations. CONCLUSIONS Parkinson disease dementia (PDD) is associated with profound visuoperceptual impairments similar to dementia with Lewy bodies (DLB) but different from Alzheimer disease. These findings are consistent with previous neuroimaging studies reporting hypoactivity in cortical areas involved in visual processing in PDD and DLB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desordens da ansiedade, especialmente a agorafobia e a desordem do pânico foram associadas a anormalidades das funções vestibulares. Evidências de que o controle do equilíbrio pode exigir habilidades atencionais também foram relatadas. Utilizando o medo de altura como modelo clínico onde sintomas ansiosos coexistem com anormalidades com a percepção espacial e controle do equilíbrio, este estudo investigou o desempenho em testes de atenção visual em voluntários normais com altos e baixos escores obtidos do Questionário de Acrofobia. O teste de rastreio visual foi realizado em 30 indivíduos (15 em cada grupo) enquanto ouviam dois tipos diferentes de estímulos auditivos. Na condição volume um som de 900 Hz era apresentado em ambos ouvidos durante 2 segundos seguidos de mais 2 segundos de silêncio. Na condição balanço , o mesmo som era apresentado durante 2 segundos ao ouvido direito seguido por 2 segundos ao ouvido esquerdo. Estímulos auditivos de movimento provocaram maior desconforto em ambos os grupos, mas nos indivíduos com maiores escores de acrofobia estes estímulos foram associados a um pior desempenho no teste visual. Embora muito limitado pela amostra experimental, este estudo sugere que o medo de altura pode estar associado à dependência visual para manutenção do equilíbrio e que poderia piorar o desempenho nos testes visuais devido à competição dos recursos neuro-cognitivos. Implicações experimentais e clínicas destes achados preliminares exigem outras pesquisas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desordens da ansiedade, especialmente a agorafobia e a desordem do pânico foram associadas a anormalidades das funções vestibulares. Evidências de que o controle do equilíbrio pode exigir habilidades atencionais também foram relatadas. Utilizando o medo de altura como modelo clínico onde sintomas ansiosos coexistem com anormalidades com a percepção espacial e controle do equilíbrio, este estudo investigou o desempenho em testes de atenção visual em voluntários normais com altos e baixos escores obtidos do Questionário de Acrofobia. O teste de rastreio visual foi realizado em 30 indivíduos (15 em cada grupo) enquanto ouviam dois tipos diferentes de estímulos auditivos. Na condição volume um som de 900 Hz era apresentado em ambos ouvidos durante 2 segundos seguidos de mais 2 segundos de silêncio. Na condição balanço , o mesmo som era apresentado durante 2 segundos ao ouvido direito seguido por 2 segundos ao ouvido esquerdo. Estímulos auditivos de movimento provocaram maior desconforto em ambos os grupos, mas nos indivíduos com maiores escores de acrofobia estes estímulos foram associados a um pior desempenho no teste visual. Embora muito limitado pela amostra experimental, este estudo sugere que o medo de altura pode estar associado à dependência visual para manutenção do equilíbrio e que poderia piorar o desempenho nos testes visuais devido à competição dos recursos neuro-cognitivos. Implicações experimentais e clínicas destes achados preliminares exigem outras pesquisas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: In Europe, 25% of workers use video display terminals (VDTs). Occupational health surveillance has been considered a key element in the protection of these workers. Nevertheless, it is unclear if guidelines available for this purpose, based on EU standards and available evidence, meet currently accepted quality criteria. The aim of this study was to appraise three sets of European VDT guidelines (UK, France, Spain) in which regulatory and evidence-based approaches for visual health have been formulated and recommendations for practice made. Methods: Three independent appraisers used an adapted AGREE instrument with seven domains to appraise the guidelines. A modified nominal group technique approach was used in two consecutive phases: first, individual evaluation of the three guidelines simultaneously, and second, a face-to-face meeting of appraisers to discuss scoring. Analysis of ratings obtained in each domain and variability among appraisers was undertaken (correlation and kappa coefficients). Results: All guidelines had low domain scores. The domain evaluated most highly was Scope and purpose, while Applicability was scored minimally. The UK guidelines had the highest overall score, and the Spanish ones had the lowest. The analysis of reliability and differences between scores in each domain showed a high level of agreement. Conclusions: These results suggest current guidelines used in these countries need an update. The formulation of evidence-base European guidelines on VDT could help to reduce the significant variation of national guidelines, which may have an impact on practical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Information processing speed, as measured by elementary cognitive tasks, is correlated with higher order cognitive ability so that increased speed relates to improved cognitive performance. The question of whether the genetic variation in Inspection Time (IT) and Choice Reaction Time (CRT) is associated with IQ through a unitary factor was addressed in this multivariate genetic study of IT, CRT, and IQ subtest scores. The sample included 184 MZ and 206 DZ twin pairs with a mean age of 16.2 years (range 15-18 years). They were administered a visual (pi-figure) IT task, a two-choice RT task, five computerized subtests of the Multidimensional Aptitude Battery, and the digit symbol substitution subtest from the WAIS-R. The data supported a factor model comprising a general, three group (verbal ability, visuospatial ability, broad speediness), and specific genetic factor structure, a shared environmental factor influencing all tests but IT, plus unique environmental factors that were largely specific to individual measures. The general genetic factor displayed factor loadings ranging between 0.35 and 0.66 for the IQ subtests, with IT and CRT loadings of -0.47 and -0.24, respectively. Results indicate that a unitary factor is insufficient to describe the entire relationship between cognitive speed measures and all IQ subtests, with independent genetic effects explaining further covariation between processing speed (especially CRT) and Digit Symbol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: left ventricular wall motion on 2d echo (2de) is usually scored visually. we sought to examine the determinants of visually assessed wall motion scoring on 2de by comparison with myocardial thickening quantified on MRI. Methods: using a 16 segment model, we studied 287 segments in 30 patients aged 61+/ -11 years (6 female), with ischaemic LV dysfunction (defined by at least 2 segments dysfunctional on 2de). 2de was performed in 5 views and wall motion scores (WMS) assigned: 1 (normal) 103 segments, 2 (hypokinetic) 93 segments, 3 (akinetic) 87 segments. MRI was used to measure end systolic wall thickness (ESWT), end diastolic wall thickness (EDWT) and percentage systolic wall thickening (SWT%) in the plane of the 2de and to assess WMS in the same planes visually. No patient had a clinical ischemic event between the tests. Results: visual assessment of wall motion by 2de and MRI showed moderate agreement (kappa = 0.425). Resting 2de wall motion correlated significantly (p

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desordens da ansiedade, especialmente a agorafobia e a desordem do pânico foram associadas a anormalidades das funções vestibulares. Evidências de que o controle do equilíbrio pode exigir habilidades atencionais também foram relatadas. Utilizando o medo de altura como modelo clínico onde sintomas ansiosos coexistem com anormalidades com a percepção espacial e controle do equilíbrio, este estudo investigou o desempenho em testes de atenção visual em voluntários normais com altos e baixos escores obtidos do Questionário de Acrofobia. O teste de rastreio visual foi realizado em 30 indivíduos (15 em cada grupo) enquanto ouviam dois tipos diferentes de estímulos auditivos. Na condição volume um som de 900 Hz era apresentado em ambos ouvidos durante 2 segundos seguidos de mais 2 segundos de silêncio. Na condição balanço , o mesmo som era apresentado durante 2 segundos ao ouvido direito seguido por 2 segundos ao ouvido esquerdo. Estímulos auditivos de movimento provocaram maior desconforto em ambos os grupos, mas nos indivíduos com maiores escores de acrofobia estes estímulos foram associados a um pior desempenho no teste visual. Embora muito limitado pela amostra experimental, este estudo sugere que o medo de altura pode estar associado à dependência visual para manutenção do equilíbrio e que poderia piorar o desempenho nos testes visuais devido à competição dos recursos neuro-cognitivos. Implicações experimentais e clínicas destes achados preliminares exigem outras pesquisas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The binocular Esterman visual field test (EVFT) is the current visual field test for driving in the UK. Merging of monocular field tests (Integrated Visual Field, IVF) has been proposed as an alternative for glaucoma patients. Aims: To examine the level of agreement between the EVFT and IVF for patients with binocular paracentral scotomata, caused by either ophthalmological or neurological conditions, and to compare outcomes with useful field of view (UFOV) performance, a test of visual attention thought to be important in driving. Methods: 60 patients with binocular paracentral scotomata but normal visual acuity (VA) were recruited prospectively. Subjects completed and were classified as “pass” or “fail” for the EVFT, IVF and UFOV. Results: Good agreement occurred between the EVFT and IVF in classifying subjects as “pass” or “fail” (kappa?=?0.84). Classifications disagreed for four subjects with paracentral scotomata of neurological origin (three “passed” IVF yet “failed” EVFT). Mean UFOV scores did not differ between those who “passed” and those who “failed” both visual field tests (p?=?0.11). Agreement between the visual field tests and UFOV was limited (EVFT kappa?=?0.22, IVF kappa 0.32). Conclusions: Although the IVF and EVFT agree well in classifying visual fields with regard to legal fitness to drive in the UK, the IVF “passes” some individuals currently classed as unfit to drive due to paracentral scotomata of non-glaucomatous origin. The suitability of the UFOV for assessing crash risk in those with visual field loss is questionable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The orientations of lines and edges are important in defining the structure of the visual environment, and observers can detect differences in line orientation within the first few hundred milliseconds of scene viewing. The present work is a psychophysical investigation of the mechanisms of early visual orientation-processing. In experiments with briefly presented displays of line elements, observers indicated whether all the elements were uniformly oriented or whether a uniquely oriented target was present among uniformly oriented nontargets. The minimum difference between nontarget and target orientations that was required for effective target-detection (the orientation increment threshold) varied little with the number of elements and their spatial density, but the percentage of correct responses in detection of a large orientation-difference increased with increasing element density. The differing variations with element density of thresholds and percent-correct scores may indicate the operation of more than one mechanism in early visual orientation-processIng. Reducing element length caused threshold to increase with increasing number of elements, showing that the effectiveness of rapid, spatially parallel orientation-processing depends on element length. Orientational anisotropy in line-target detection has been reported previously: a coarse periodic variation and some finer variations in orientation increment threshold with nontarget orientation have been found. In the present work, the prominence of the coarse variation in relation to finer variations decreased with increasing effective viewing duration, as if the operation of coarse orientation-processing mechanisms precedes the operation of finer ones. Orientational anisotropy was prominent even when observers lay horizontally and viewed displays by looking upwards through a black cylinder that excluded all possible visual references for orientation. So, gravitational and visual cues are not essential to the definition of an orientational reference frame for early vision, and such a reference can be well defined by retinocentric neural coding, awareness of body-axis orientation, or both.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A critical review of previous research revealed that visual attention tests, such as the Useful Field of View (UFOV) test, provided the best means of detecting age-related changes to the visual system that could potentially increase crash risk. However, the question was raised as to whether the UFOV, which was regarded as a static visual attention test, could be improved by inclusion of kinetic targets that more closely represent the driving task. A computer program was written to provide more information about the derivation of UFOV test scores. Although this investigation succeeded in providing new information, some of the commercially protected UFOV test procedures still remain unknown. Two kinetic visual attention tests (DRTS1 and 2), developed at Aston University to investigate inclusion of kinetic targets in visual attention tests, were introduced. The UFOV was found to be more repeatable than either of the kinetic visual attention tests and learning effects or age did not influence these findings. Determinants of static and kinetic visual attention were explored. Increasing target eccentricity led to reduced performance on the UFOV and DRTS1 tests. The DRTS2 was not affected by eccentricity but this may have been due to the style of presentation of its targets. This might also have explained why only the DRTS2 showed laterality effects (i.e. better performance to targets presented on the left hand side of the road). Radial location, explored using the UFOV test, showed that subjects responded best to targets positioned to the horizontal meridian. Distraction had opposite effects on static and kinetic visual attention. While UFOV test performance declined with distraction, DRTS1 performance increased. Previous research had shown that this striking difference was to be expected. Whereas the detection of static targets is attenuated in the presence of distracting stimuli, distracting stimuli that move in a structured flow field enhances the detection of moving targets. Subjects reacted more slowly to kinetic compared to static targets, longitudinal motion compared to angular motion and to increased self-motion. However, the effects of longitudinal motion, angular motion, self-motion and even target eccentricity were caused by target edge speed variations arising because of optic flow field effects. The UFOV test was more able to detect age-related changes to the visual system than were either of the kinetic visual attention tests. The driving samples investigated were too limited to draw firm conclusions. Nevertheless, the results presented showed that neither the DRTS2 nor the UFOV tests were powerful tools for the identification of drivers prone to crashes or poor driving performance.