946 resultados para Variable Parameters Control Charts
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents the analysis, design, simulation, and experimental results for a high frequency high Power-Factor (PF) AC (Alternate Current) voltage regulator, using a Sepic converter as power stage. The control technique employed to impose a sinusoidal input current waveform, with low Total Harmonic Distortion (THD), is the sinusoidal variable hysteresis control. The control technique was implemented in a FPGA (Field Programmable Gate Array) device, using a Hardware Description Language (VHDL). Through the use of the proposed control technique, the AC voltage regulator performs active power-factor correction, and low THD in the input current, for linear and non-linear loads, satisfying the requirements of the EEC61000-3-2 standards. Experimental results from an example prototype, designed for 300W of nominal output power, 50kHz (switching frequency), and 127Vrms of nominal input and output voltages, are presented in order to validate the proposed AC regulator. © 2005 IEEE.
Resumo:
Purpose - The aim of this paper is to present a synthetic chart based on the non-central chi-square statistic that is operationally simpler and more effective than the joint X̄ and R chart in detecting assignable cause(s). This chart will assist in identifying which (mean or variance) changed due to the occurrence of the assignable causes. Design/methodology/approach - The approach used is based on the non-central chi-square statistic and the steady-state average run length (ARL) of the developed chart is evaluated using a Markov chain model. Findings - The proposed chart always detects process disturbances faster than the joint X̄ and R charts. The developed chart can monitor the process instead of looking at two charts separately. Originality/value - The most important advantage of using the proposed chart is that practitioners can monitor the process by looking at only one chart instead of looking at two charts separately. © Emerald Group Publishing Limted.
Resumo:
In this paper, a trajectory tracking control problem for a nonholonomic mobile robot by the integration of a kinematic neural controller (KNC) and a torque neural controller (TNC) is proposed, where both the kinematic and dynamic models contains disturbances. The KNC is a variable structure controller (VSC) based on the sliding mode control theory (SMC), and applied to compensate the kinematic disturbances. The TNC is a inertia-based controller constituted of a dynamic neural controller (DNC) and a robust neural compensator (RNC), and applied to compensate the mobile robot dynamics, and bounded unknown disturbances. Stability analysis with basis on Lyapunov method and simulations results are provided to show the effectiveness of the proposed approach. © 2012 Springer-Verlag.
Resumo:
In this article we introduce the concept of MP-pseudoinvexity for general nonlinear impulsive optimal control problems whose dynamics are specified by measure driven control equations. This is a general paradigm in that, both the absolutely continuous and singular components of the dynamics depend on both the state and the control variables. The key result consists in showing the sufficiency for optimality of the MP-pseudoinvexity. It is proved that, if this property holds, then every process satisfying the maximum principle is an optimal one. This result is obtained in the context of a proper solution concept that will be presented and discussed. © 2012 IEEE.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this article, we present a new control chart for monitoring the covariance matrix in a bivariate process. In this method, n observations of the two variables were considered as if they came from a single variable (as a sample of 2n observations), and a sample variance was calculated. This statistic was used to build a new control chart specifically as a VMIX chart. The performance of the new control chart was compared with its main competitors: the generalized sampled variance chart, the likelihood ratio test, Nagao's test, probability integral transformation (v(t)), and the recently proposed VMAX chart. Among these statistics, only the VMAX chart was competitive with the VMIX chart. For shifts in both variances, the VMIX chart outperformed VMAX; however, VMAX showed better performance for large shifts (higher than 10%) in one variance.
Resumo:
For virtually all hospitals, utilization rates are a critical managerial indicator of efficiency and are determined in part by turnover time. Turnover time is defined as the time elapsed between surgeries, during which the operating room is cleaned and preparedfor the next surgery. Lengthier turnover times result in lower utilization rates, thereby hindering hospitals’ ability to maximize the numbers of patients that can be attended to. In this thesis, we analyze operating room data from a two year period provided byEvangelical Community Hospital in Lewisburg, Pennsylvania, to understand the variability of the turnover process. From the recorded data provided, we derive our best estimation of turnover time. Recognizing the importance of being able to properly modelturnover times in order to improve the accuracy of scheduling, we seek to fit distributions to the set of turnover times. We find that log-normal and log-logistic distributions are well-suited to turnover times, although further research must validate this finding. Wepropose that the choice of distribution depends on the hospital and, as a result, a hospital must choose whether to use the log-normal or the log-logistic distribution. Next, we use statistical tests to identify variables that may potentially influence turnover time. We find that there does not appear to be a correlation between surgerytime and turnover time across doctors. However, there are statistically significant differences between the mean turnover times across doctors. The final component of our research entails analyzing and explaining the benefits of introducing control charts as a quality control mechanism for monitoring turnover times in hospitals. Although widely instituted in other industries, control charts are notwidely adopted in healthcare environments, despite their potential benefits. A major component of our work is the development of control charts to monitor the stability of turnover times. These charts can be easily instituted in hospitals to reduce the variabilityof turnover times. Overall, our analysis uses operations research techniques to analyze turnover times and identify manners for improvement in lowering the mean turnover time and thevariability in turnover times. We provide valuable insight into a component of the surgery process that has received little attention, but can significantly affect utilization rates in hospitals. Most critically, an ability to more accurately predict turnover timesand a better understanding of the sources of variability can result in improved scheduling and heightened hospital staff and patient satisfaction. We hope that our findings can apply to many other hospital settings.
Resumo:
A partir de la aceptación de la biblioteca como parte del ciclo de creación, organización y diseminación del conocimiento cambió el concepto de la misma de una entidad cerrada hacia un sistema dinámico en constante interacción con su entorno. Así se la reconoció como una institución social más que como una colección de documentos. Desde entonces se percibió a la biblioteca como una entidad en la que se podía aplicar los principios de gestión. Desde entonces se utilizaron distintas herramientas de gestión para la toma de decisiones en el ámbito de las bibliotecas. Entre estas herramientas son de gran importancia en el control estadístico de procesos los gráficos de control, utilizados para medir la estabilidad de un proceso a través del tiempo. Han tenido amplia aplicación en el control estadístico de la calidad, comenzando en el ámbito industrial. Hoy su aplicación se ha extendido a una gran variedad de disciplinas incluyen empresas de servicios y unidades administrativas. Aquí se presentan a los gráficos de control como una importante herramienta de gestión aplicada a los procesos técnicos permitiendo su evaluación y el monitoreo de su desempeño a partir de la utilización de indicadores y otros datos de carácter diagnóstico
Resumo:
A partir de la aceptación de la biblioteca como parte del ciclo de creación, organización y diseminación del conocimiento cambió el concepto de la misma de una entidad cerrada hacia un sistema dinámico en constante interacción con su entorno. Así se la reconoció como una institución social más que como una colección de documentos. Desde entonces se percibió a la biblioteca como una entidad en la que se podía aplicar los principios de gestión. Desde entonces se utilizaron distintas herramientas de gestión para la toma de decisiones en el ámbito de las bibliotecas. Entre estas herramientas son de gran importancia en el control estadístico de procesos los gráficos de control, utilizados para medir la estabilidad de un proceso a través del tiempo. Han tenido amplia aplicación en el control estadístico de la calidad, comenzando en el ámbito industrial. Hoy su aplicación se ha extendido a una gran variedad de disciplinas incluyen empresas de servicios y unidades administrativas. Aquí se presentan a los gráficos de control como una importante herramienta de gestión aplicada a los procesos técnicos permitiendo su evaluación y el monitoreo de su desempeño a partir de la utilización de indicadores y otros datos de carácter diagnóstico
Resumo:
A partir de la aceptación de la biblioteca como parte del ciclo de creación, organización y diseminación del conocimiento cambió el concepto de la misma de una entidad cerrada hacia un sistema dinámico en constante interacción con su entorno. Así se la reconoció como una institución social más que como una colección de documentos. Desde entonces se percibió a la biblioteca como una entidad en la que se podía aplicar los principios de gestión. Desde entonces se utilizaron distintas herramientas de gestión para la toma de decisiones en el ámbito de las bibliotecas. Entre estas herramientas son de gran importancia en el control estadístico de procesos los gráficos de control, utilizados para medir la estabilidad de un proceso a través del tiempo. Han tenido amplia aplicación en el control estadístico de la calidad, comenzando en el ámbito industrial. Hoy su aplicación se ha extendido a una gran variedad de disciplinas incluyen empresas de servicios y unidades administrativas. Aquí se presentan a los gráficos de control como una importante herramienta de gestión aplicada a los procesos técnicos permitiendo su evaluación y el monitoreo de su desempeño a partir de la utilización de indicadores y otros datos de carácter diagnóstico
Resumo:
The ground surface temperature is one of the key parameters that determine the thermal regime of permafrost soils in arctic regions. Due to remoteness of most permafrost areas, monitoring of the land surface temperature (LST) through remote sensing is desirable. However, suitable satellite platforms such as MODIS provide spatial resolutions, that cannot resolve the considerable small-scale heterogeneity of the surface conditions characteristic for many permafrost areas. This study investigates the spatial variability of summer surface temperatures of high-arctic tundra on Svalbard, Norway. A thermal imaging system mounted on a mast facilitates continuous monitoring of approximately 100 x 100 m of tundra with a wide variability of different surface covers and soil moisture conditions over the entire summer season from the snow melt until fall. The net radiation is found to be a control parameter for the differences in surface temperature between wet and dry areas. Under clear-sky conditions in July, the differences in surface temperature between wet and dry areas reach up to 10K. The spatial differences reduce strongly in weekly averages of the surface temperature, which are relevant for the soil temperature evolution of deeper layers. Nevertheless, a considerable variability remains, with maximum differences between wet and dry areas of 3 to 4K. Furthermore, the pattern of snow patches and snow-free areas during snow melt in July causes even greater differences of more than 10K in the weekly averages. Towards the end of the summer season, the differences in surface temperature gradually diminish. Due to the pronounced spatial variability in July, the accumulated degree-day totals of the snow-free period can differ by more than 60% throughout the study area. The terrestrial observations from the thermal imaging system are compared to measurements of the land surface temperature from the MODIS sensor. During periods with frequent clear-sky conditions and thus a high density of satellite data, weekly averages calculated from the thermal imaging system and from MODIS LST agree within less than 2K. Larger deviations occur when prolonged cloudy periods prevent satellite measurements. Futhermore, the employed MODIS L2 LST data set contains a number of strongly biased measurements, which suggest an admixing of cloud top temperatures. We conclude that a reliable gap filling procedure to moderate the impact of prolonged cloudy periods would be of high value for a future LST-based permafrost monitoring scheme. The occurrence of sustained subpixel variability of the summer surface temperature is a complicating factor, whose impact needs to be assessed further in conjunction with other spatially variable parameters such as the snow cover and soil properties.
Resumo:
Esta Tesis Doctoral evalúa empíricamente la calidad del servicio en la línea de atraque de las terminales portuarias de contenedores. La metodología propuesta utiliza indicadores de calidad y se basa en el concepto de la segmentación de servicio. Para ello se desarrolla la teoría del Control Estadístico de Procesos (CEP) y se utilizan los gráficos de control para clasificar el servicio en las terminales de contenedores. El propósito de la Tesis es proporcionar una metodología basada en el Control Estadístico de Procesos (CEP) para evaluar la calidad del servicio y detectar las escalas de un servicio regular de línea que se encuentran fuera de control. Por tanto, la metodología se puede utilizar para detectar eventos que son indicativos de cambio real del proceso en la línea de atraque. Esta detección puede ser compleja pues las características de los procesos en terminales de contenedores son variables. La metodología proporciona mediante los gráficos de control criterios estadísticamente objetivos de cambio. Cuando el cambio es detectado y considerado bueno sus causas deben ser identificadas y posiblemente convertirse en la nueva forma de trabajar, cuando el cambio es negativo, entonces sus causas deberían ser identificadas y eliminadas. La Tesis Doctoral está organizado de la siguiente manera: La primera parte es la introducción, e incluye los capítulos 1 al 4, la segunda parte presenta el Estado del Arte (capítulo 5) y algunos de los estudios que han inspirado esta investigación, la tercera parte se centra en la metodología utilizada (capítulo 6) y su aplicación sobre un caso de estudio (capítulo 7). Finalmente, en la cuarta parte se presentan las conclusiones y se proponen algunas de las nuevas líneas de investigación que quedan abiertas (capítulo 8). This Thesis empirically evaluates the quality of service in the berthing face of container terminals. The methodology proposed is focused on quality of service indicators and is based on the concept of service segmentation. The Statistical Process Control (SPC) theory and the control charts are used to classify container terminal service. The aim of this Thesis is to provide a methodology based on Statistical Process Control that can evaluate the quality of service and also can detect scales of shipping liner service that are out of control. Therefore, the methodology can be used to detect events that are indicative of real change in the berthing process of container vessels. The methodology proposed allows simple detection of events that are indicative of actual process change in container terminals. This detection is complex because the characteristics of the processes are variable in the container terminals; the control chart provides statistically objective criteria of change. When change is detected and considered good its cause should be identified and possibly become the new way of working, where the change is bad then its cause should be identified and eliminated. This Thesis is organized as follows: The first part is the introduction (includes Chapters 1 to 4), the second part presents the State of the Art (Chapter 5) and some of the studies that have inspired this research. The third part focuses on the methodology used (Chapter 6) and its application to a case study (Chapter 7). Finally, Part 4 presents the conclusions and suggests future research (Chapter 8).
Resumo:
La telepesencia combina diferentes modalidades sensoriales, incluyendo, entre otras, la visual y la del tacto, para producir una sensación de presencia remota en el operador. Un elemento clave en la implementación de sistemas de telepresencia para permitir una telemanipulación del entorno remoto es el retorno de fuerza. Durante una telemanipulación, la energía mecánica es transferida entre el operador humano y el entorno remoto. En general, la energía es una propiedad de los objetos físicos, fundamental en su mutual interacción. En esta interacción, la energía se puede transmitir entre los objetos, puede cambiar de forma pero no puede crearse ni destruirse. En esta tesis, se aplica este principio fundamental para derivar un nuevo método de control bilateral que permite el diseño de sistemas de teleoperación estables para cualquier arquitectura concebible. El razonamiento parte del hecho de que la energía mecánica insertada por el operador humano en el sistema debe transferirse hacia el entorno remoto y viceversa. Tal como se verá, el uso de la energía como variable de control permite un tratamiento más general del sistema que el control convencional basado en variables específicas del sistema. Mediante el concepto de Red de Potencia de Retardo Temporal (RPRT), el problema de definir los flujos de energía en un sistema de teleoperación es solucionado con independencia de la arquitectura de comunicación. Como se verá, los retardos temporales son la principal causa de generación de energía virtual. Este hecho se observa con retardos a partir de 1 milisegundo. Esta energía virtual es añadida al sistema de forma intrínseca y representa la causa principal de inestabilidad. Se demuestra que las RPRTs son transportadoras de la energía deseada intercambiada entre maestro y esclavo pero a la vez generadoras de energía virtual debido al retardo temporal. Una vez estas redes son identificadas, el método de Control de Pasividad en el Dominio Temporal para RPRTs se propone como mecanismo de control para asegurar la pasividad del sistema, y as__ la estabilidad. El método se basa en el simple hecho de que esta energía virtual debido al retardo debe transformarse en disipación. As__ el sistema se aproxima al sistema deseado, donde solo la energía insertada desde un extremo es transferida hacia el otro. El sistema resultante presenta dos cualidades: por un lado la estabilidad del sistema queda garantizada con independencia de la arquitectura del sistema y del canal de comunicación; por el otro, el rendimiento es maximizado en términos de fidelidad de transmisión energética. Los métodos propuestos se sustentan con sistemas experimentales con diferentes arquitecturas de control y retardos entre 2 y 900 ms. La tesis concluye con un experimento que incluye una comunicación espacial basada en el satélite geoestacionario ASTRA. ABSTRACT Telepresence combines different sensorial modalities, including vision and touch, to produce a feeling of being present in a remote location. The key element to successfully implement a telepresence system and thus to allow telemanipulation of a remote environment is force feedback. In a telemanipulation, mechanical energy must convey from the human operator to the manipulated object found in the remote environment. In general, energy is a property of all physical objects, fundamental to their mutual interactions in which the energy can be transferred among the objects and can change form but cannot be created or destroyed. In this thesis, we exploit this fundamental principle to derive a novel bilateral control mechanism that allows designing stable teleoperation systems with any conceivable communication architecture. The rationale starts from the fact that the mechanical energy injected by a human operator into the system must be conveyed to the remote environment and Vice Versa. As will be seen, setting energy as the control variable allows a more general treatment of the controlled system in contrast to the more conventional control of specific systems variables. Through the Time Delay Power Network (TDPN) concept, the issue of defining the energy flows involved in a teleoperation system is solved with independence of the communication architecture. In particular, communication time delays are found to be a source of virtual energy. This fact is observed with delays starting from 1 millisecond. Since this energy is added, the resulting teleoperation system can be non-passive and thus become unstable. The Time Delay Power Networks are found to be carriers of the desired exchanged energy but also generators of virtual energy due to the time delay. Once these networks are identified, the Time Domain Passivity Control approach for TDPNs is proposed as a control mechanism to ensure system passivity and therefore, system stability. The proposed method is based on the simple fact that this intrinsically added energy due to the communication must be transformed into dissipation. Then the system becomes closer to the ambitioned one, where only the energy injected from one end of the system is conveyed to the other one. The resulting system presents two benefits: On one hand, system stability is guaranteed through passivity independently from the chosen control architecture and communication channel; on the other, performance is maximized in terms of energy transfer faithfulness. The proposed methods are sustained with a set of experimental implementations using different control architectures and communication delays ranging from 2 to 900 milliseconds. An experiment that includes a communication Space link based on the geostationary satellite ASTRA concludes this thesis.