995 resultados para Validated Interval Software


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorpheniramine maleate (CLOR) enantiomers were quantified by ultraviolet spectroscopy and partial least squares regression. The CLOR enantiomers were prepared as inclusion complexes with beta-cyclodextrin and 1-butanol with mole fractions in the range from 50 to 100%. For the multivariate calibration the outliers were detected and excluded and variable selection was performed by interval partial least squares and a genetic algorithm. Figures of merit showed results for accuracy of 3.63 and 2.83% (S)-CLOR for root mean square errors of calibration and prediction, respectively. The ellipse confidence region included the point for the intercept and the slope of 1 and 0, respectively. Precision and analytical sensitivity were 0.57 and 0.50% (S)-CLOR, respectively. The sensitivity, selectivity, adjustment, and signal-to-noise ratio were also determined. The model was validated by a paired t test with the results obtained by high-performance liquid chromatography proposed by the European pharmacopoeia and circular dichroism spectroscopy. The results showed there was no significant difference between the methods at the 95% confidence level, indicating that the proposed method can be used as an alternative to standard procedures for chiral analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction - Baccharis dracunculifolia, which has great potential for the development of new phytotherapeutic medicines, is the most important botanical source of the southeastern Brazilian propolis, known as green propolis on account of its color. Objective - To develop a reliable reverse-phase HPLC chromatographic method for the analysis of phenolic compounds in both B. dracunculifolia raw material and its hydroalcoholic extracts. Methodology - The method utilised a C(18) CLC-ODS (M) (4.6 x 250 mm) column with nonlinear gradient elution and UV detection at 280 nm. A procedure for the extraction of phenolic compounds using aqueous ethanol 90%, with the addition of veratraldehyde as the internal standard, was developed allowing the quantification of 10 compounds: caffeic acid, coumaric acid, ferulic acid, cinnamic acid, aromadendrin-4`-methyl ether, isosakuranetin, drupanin, artepillin C, baccharin and 2,2-dimethyl-6-carboxyethenyl-2H-1-benzopyran acid. Results - The developed method gave a good detection response with linearity in the range 20.83-800 mu g/mL and recovery in the range 81.25-93.20%, allowing the quantification of the analysed standards. Conclusion - The method presented good results for the following parameters: selectivity, linearity, accuracy, precision, robustness, as well as limit of detection and limit of quantitation. Therefore, this method could be considered as an analytical tool for the quality control of B. dracunculifolia raw material and its products in both cosmetic and pharmaceutical companies. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While the physiological adaptations that occur following endurance training in previously sedentary and recreationally active individuals are relatively well understood, the adaptations to training in already highly trained endurance athletes remain unclear. While significant improvements in endurance performance and corresponding physiological markers are evident following submaximal endurance training in sedentary and recreationally active groups, an additional increase in submaximal training (i.e. volume) in highly trained individuals does not appear to further enhance either endurance performance or associated physiological variables [e.g. peak oxygen uptake (V-dot O2peak), oxidative enzyme activity]. It seems that, for athletes who are already trained, improvements in endurance performance can be achieved only through high-intensity interval training (HIT). The limited research which has examined changes in muscle enzyme activity in highly trained athletes, following HIT, has revealed no change in oxidative or glycolytic enzyme activity, despite significant improvements in endurance performance (p < 0.05). Instead, an increase in skeletal muscle buffering capacity may be one mechanism responsible for an improvement in endurance performance. Changes in plasma volume, stroke volume, as well as muscle cation pumps, myoglobin, capillary density and fibre type characteristics have yet to be investigated in response to HIT with the highly trained athlete. Information relating to HIT programme optimisation in endurance athletes is also very sparse. Preliminary work using the velocity at which V-dot O2max is achieved (Vmax) as the interval intensity, and fractions (50 to 75%) of the time to exhaustion at Vmax (Tmax) as the interval duration has been successful in eliciting improvements in performance in long-distance runners. However, Vmax and Tmax have not been used with cyclists. Instead, HIT programme optimisation research in cyclists has revealed that repeated supramaximal sprinting may be equally effective as more traditional HIT programmes for eliciting improvements in endurance performance. Further examination of the biochemical and physiological adaptations which accompany different HIT programmes, as well as investigation into the optimal HIT programme for eliciting performance enhancements in highly trained athletes is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes recent updates to the custom-built data-acquisition hardware operated by the Center for Hypersonics. In 2006, an ISA-to-USB bridging card was developed as part of Luke Hillyard's final-year thesis. This card allows the hardware to be connected to any recent personal computers via a (USB or RS232) serial port and it provides a number of simple text-based commands for control of the hardware. A graphical user interface program was also updated to help the experimenter manage the data acquisition functions. Sampled data is stored in text files that have been compressed with the gzip for mat. To simplify the later archiving or transport of the data, all files specific to a shot are stored in a single directory. This includes a text file for the run description, the signal configuration file and the individual sampled-data files, one for each signal that was recorded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The XSophe-Sophe-XeprView((R)) computer simulation software suite enables scientists to easily determine spin Hamiltonian parameters from isotropic, randomly oriented and single crystal continuous wave electron paramagnetic resonance (CW EPR) spectra from radicals and isolated paramagnetic metal ion centers or clusters found in metalloproteins, chemical systems and materials science. XSophe provides an X-windows graphical user interface to the Sophe programme and allows: creation of multiple input files, local and remote execution of Sophe, the display of sophelog (output from Sophe) and input parameters/files. Sophe is a sophisticated computer simulation software programme employing a number of innovative technologies including; the Sydney OPera HousE (SOPHE) partition and interpolation schemes, a field segmentation algorithm, the mosaic misorientation linewidth model, parallelization and spectral optimisation. In conjunction with the SOPHE partition scheme and the field segmentation algorithm, the SOPHE interpolation scheme and the mosaic misorientation linewidth model greatly increase the speed of simulations for most spin systems. Employing brute force matrix diagonalization in the simulation of an EPR spectrum from a high spin Cr(III) complex with the spin Hamiltonian parameters g(e) = 2.00, D = 0.10 cm(-1), E/D = 0.25, A(x) = 120.0, A(y) = 120.0, A(z) = 240.0 x 10(-4) cm(-1) requires a SOPHE grid size of N = 400 (to produce a good signal to noise ratio) and takes 229.47 s. In contrast the use of either the SOPHE interpolation scheme or the mosaic misorientation linewidth model requires a SOPHE grid size of only N = 18 and takes 44.08 and 0.79 s, respectively. Results from Sophe are transferred via the Common Object Request Broker Architecture (CORBA) to XSophe and subsequently to XeprView((R)) where the simulated CW EPR spectra (1D and 2D) can be compared to the experimental spectra. Energy level diagrams, transition roadmaps and transition surfaces aid the interpretation of complicated randomly oriented CW EPR spectra and can be viewed with a web browser and an OpenInventor scene graph viewer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the incidence of interval cancers which occurred in the first 12 months after mammographic screening at a mammographic screening service. Design: Retrospective analysis of data obtained by crossmatching the screening Service and the New South Wales Central Cancer Registry databases. Setting: The Central & Eastern Sydney Service of BreastScreen NSW. Participants: Women aged 40-69 years at first screen, who attended for their first or second screen between 1 March 1988 and 31 December 1992. Main outcome measures: Interval-cancer rates per 10 000 screens and as a proportion of the underlying incidence of breast cancer (as estimated by the underlying rate in the total NSW population). Results: The 12-month interval-cancer incidence per 10 000 screens was 4.17 for the 40-49 years age group (95% confidence interval [CI], 1.35-9.73) and 4.64 for the 50-69 years age group (95% CI, 2.47-7.94). Proportional incidence rates were 30.1% for the 40-49 years age group (95% CI, 9.8-70.3) and 22% for the 50-69 years age group (95% CI, 11.7-37.7). There was no significant difference between the proportional incidence rate for the 50-69 years age group for the Central & Eastern Sydney Service and those of major successful overseas screening trials. Conclusion: Screening quality was acceptable and should result in a significant mortality reduction in the screened population. Given the small number of cancers involved, comparison of interval-cancer statistics of mammographic screening programs with trials requires age-specific or age-adjusted data, and consideration of confidence intervals of both program and trial data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expokit provides a set of routines aimed at computing matrix exponentials. More precisely, it computes either a small matrix exponential in full, the action of a large sparse matrix exponential on an operand vector, or the solution of a system of linear ODEs with constant inhomogeneity. The backbone of the sparse routines consists of matrix-free Krylov subspace projection methods (Arnoldi and Lanczos processes), and that is why the toolkit is capable of coping with sparse matrices of large dimension. The software handles real and complex matrices and provides specific routines for symmetric and Hermitian matrices. The computation of matrix exponentials is a numerical issue of critical importance in the area of Markov chains and furthermore, the computed solution is subject to probabilistic constraints. In addition to addressing general matrix exponentials, a distinct attention is assigned to the computation of transient states of Markov chains.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this and a preceding paper, we provide an introduction to the Fujitsu VPP range of vector-parallel supercomputers and to some of the computational chemistry software available for the VPP. Here, we consider the implementation and performance of seven popular chemistry application packages. The codes discussed range from classical molecular dynamics to semiempirical and ab initio quantum chemistry. All have evolved from sequential codes, and have typically been parallelised using a replicated data approach. As such they are well suited to the large-memory/fast-processor architecture of the VPP. For one code, CASTEP, a distributed-memory data-driven parallelisation scheme is presented. (C) 2000 Published by Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the impact of increasing the minimum resupply period for prescriptions on the Pharmaceutical Benefits Scheme (PBS) in November 1994. The intervention was designed to reduce the stockpiling of medicines used for chronic medical conditions under the PBS safety net. Methods: Interrupted times series regression analyses were performed on 114 months of PBS drug utilisation data from January 1991 to June 2000. These analyses assessed whether there had been a significant interaction between the onset of the intervention in November 1994 and the extreme levels of drug utilisation in the months of December (peak utilisation) and January (lowest utilisation) respectively. Both serial and 12-month lag autocorrelations were controlled for. Results: The onset of the intervention was associated with a significant reduction in the December peak in drug utilisation; after the introduction of the policy there were 1,150,196 fewer proscriptions on average or that month (95% Cl 708,333-1,592,059). There was, however, no significant change in the low level of utilisation in January. The effect of the policy appears to be decreasing across successive postintervention years. though the odds of a prescription being dispensed in December remained significantly lower in 1999 compared to each of the pre-intervention years (11% vs. 14%) Conclusion: Analysis of the impact of increasing the re-supply period for PBS prescriptions showed that the magnitude of peak utilisation in December had been markedly reduced by the policy, though this effect appears to be decreasing over time. Continued monitoring and policy review is warranted in order to ensure that the initial effect of the intervention be maintained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L-studio/cpfg is a plant modeling software system designed for Windows 95/98/NT platforms. Its key components are the L-system-based plant simulator cpfg and the modeling environment called L-studio. We overview version 1.0 of this system from the user's perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effects of four high-intensity interval-training (HIT) sessions performed over 2 weeks on peak volume of oxygen uptake (VO2peak), the first and second ventilatory thresholds (UT VT2) and peak power output (PPO) in highly trained cyclists. Fourteen highly trained male cyclists (VO2peak = 67.5 +/- 3.7 ml . kg(-1) . min(-1)) performed a ramped cycle test to determine VO2peak VT1 VT2, and PPO. Subjects were divided equally into a HIT group and a control group. The HIT group performed four HIT sessions (20 x 60 s at PPO, 120 s recovery); the V-02peak test was repeated <I wk after the HIT program. Control subjects maintained their regular training program and were reassessed under the same timeline. There was no change in V0(2peak) for either group; however, the HIT group showed a significantly greater increase in VT1, (+22% vs. -3%), VT2 (+15% vs. -1%), and PPO (+4.3 vs. -.4%) compared to controls (all P <.05). This study has demonstrated that HIT can improve VT1, VT2,, and PPO, following only four HIT sessions in already highly trained cyclists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypothesis that prepulse inhibition of the blink reflex reflects a transient process that protects preattentive processing of the prepulse was investigated. Participants were presented with pairs of blink-eliciting noises, with some noises preceded by a prepulse, and were asked to rate the intensity of the second noise relative to the first. Inhibition of blink amplitude was greater for a 110 dB(A) noise than for a 95 dB(A) noise with a 120 ms lead interval, whereas there was no difference with a 30 ms lead interval. The reduction in perceived intensity was greater for the 110 dB(A) noise than for the 95 dB(A) noise with the 120 ms lead interval, but not with the 30 ms lead interval. The parallel results support an association between prepulse inhibition and perceived intensity. However, the prepulse did not reduce intensity ratings relative to control trials in some conditions, suggesting that prepulse inhibition is not always associated with an attenuation of the impact of the blink-eliciting stimulus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of the present paper was to investigate whether screening for abdominal aortic aneurysm (AAA) causes health-related quality of life to change in men or their partners. Methods: A cross-sectional case-control comparison was undertaken of men aged 65-83 years living in Perth, Western Australia, using questionnaires incorporating three validated instruments (Medical Outcomes Study Short Form-36, EuroQol EQ-5D and Hospital Anxiety and Depression Scale) as well as several independent questions about quality of life. The 2009 men who attended for ultrasound scans of the abdominal aorta completed a short prescreening questionnaire about their perception of their general health. Four hundred and ninety-eight men (157 with an AAA and 341 with a normal aorta) were sent two questionnaires for completion 12 months after screening, one for themselves and one for their partner, each being about the quality of life of the respondent. Results: Men with an AAA were more limited in performing physical activities than those with a normal aorta (t-test of means P = 0.04). After screening, men with an AAA were significantly less likely to have current pain or discomfort than those with a normal aorta (multivariate odds ratio: 0.5; 95% confidence interval (Cl): 0.3-0.9) and reported fewer visits to their doctor. The mean level of self-perceived general health increased for all men from before to after screening (from 63.4 to 65.4). Conclusions: Apart from physical functioning, screening was not associated with decreases in health and well-being. A high proportion of men rated their health over the year after screening as being either the same or improved, regardless of whether or not they were found to have an AAA.