984 resultados para VENTILATION: mechanically controlled
Resumo:
BACKGROUND: Current practice at high-frequency oscillatory ventilation (HFOV) initiation is a stepwise increase of the constant applied airway pressure to achieve lung recruitment. We hypothesized that HFOV would lead to more adverse cerebral haemodynamics than does pressure controlled ventilation (PCV) in the presence of experimental intracranial hypertension (IH) and acute lung injury (ALI) in pigs with similar mean airway pressure settings. METHODS: In 12 anesthetized pigs (24-27 kg) with IH and ALI, mean airway pressure (P(mean)) was increased (to 20, 25, 30 cm H(2)O every 30 min), either with HFOV or with PCV. The order of the two ventilatory modes (cross-over) was randomized. Mean arterial pressure (MAP), intracranial pressure (ICP), cerebral perfusion pressure (CPP), cerebral blood flow (CBF) (fluorescent microspheres), cerebral metabolism, transpulmonary pressures (P(T)), and blood gases were determined at each P(mean) setting. Our end-points of interest related to the cerebral circulation were ICP, CPP and CBF. RESULTS: CBF and cerebral metabolism were unaffected but there were no differences between the values for HFOV and PCV. ICP increased slightly (HFOV median +1 mm Hg, P<0.05; PCV median +2 mm Hg, P<0.05). At P(mean) setting of 30 cm H(2)O, CPP decreased during HFOV (median -13 mm Hg, P<0.05) and PCV (median -17 mm Hg, P<0.05) paralleled by a decrease of MAP (HFOV median -11 mm Hg, P<0.05; PCV median -13 mm Hg, P<0.05). P(T) increased (HFOV median +8 cm H(2)O, P<0.05; PCV median +8 cm H(2)O, P<0.05). Oxygenation improved and normocapnia maintained by HFOV and PCV. There were no differences between both ventilatory modes. CONCLUSIONS: In animals with elevated ICP and ALI, both ventilatory modes had effects upon cerebral haemodynamics. The effects upon cerebral haemodynamics were dependent of the P(T) level without differences between both ventilatory modes at similar P(mean) settings. HFOV seems to be a possible alternative ventilatory strategy when MAP deterioration can be avoided.
Resumo:
INTRODUCTION: The objective was to study the effects of a lung recruitment procedure by stepwise increases of mean airway pressure upon organ blood flow and hemodynamics during high-frequency oscillatory ventilation (HFOV) versus pressure-controlled ventilation (PCV) in experimental lung injury. METHODS: Lung damage was induced by repeated lung lavages in seven anesthetized pigs (23-26 kg). In randomized order, HFOV and PCV were performed with a fixed sequence of mean airway pressure increases (20, 25, and 30 mbar every 30 minutes). The transpulmonary pressure, systemic hemodynamics, intracranial pressure, cerebral perfusion pressure, organ blood flow (fluorescent microspheres), arterial and mixed venous blood gases, and calculated pulmonary shunt were determined at each mean airway pressure setting. RESULTS: The transpulmonary pressure increased during lung recruitment (HFOV, from 15 +/- 3 mbar to 22 +/- 2 mbar, P < 0.05; PCV, from 15 +/- 3 mbar to 23 +/- 2 mbar, P < 0.05), and high airway pressures resulted in elevated left ventricular end-diastolic pressure (HFOV, from 3 +/- 1 mmHg to 6 +/- 3 mmHg, P < 0.05; PCV, from 2 +/- 1 mmHg to 7 +/- 3 mmHg, P < 0.05), pulmonary artery occlusion pressure (HFOV, from 12 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 13 +/- 2 mmHg to 15 +/- 2 mmHg, P < 0.05), and intracranial pressure (HFOV, from 14 +/- 2 mmHg to 16 +/- 2 mmHg, P < 0.05; PCV, from 15 +/- 3 mmHg to 17 +/- 2 mmHg, P < 0.05). Simultaneously, the mean arterial pressure (HFOV, from 89 +/- 7 mmHg to 79 +/- 9 mmHg, P < 0.05; PCV, from 91 +/- 8 mmHg to 81 +/- 8 mmHg, P < 0.05), cardiac output (HFOV, from 3.9 +/- 0.4 l/minute to 3.5 +/- 0.3 l/minute, P < 0.05; PCV, from 3.8 +/- 0.6 l/minute to 3.4 +/- 0.3 l/minute, P < 0.05), and stroke volume (HFOV, from 32 +/- 7 ml to 28 +/- 5 ml, P < 0.05; PCV, from 31 +/- 2 ml to 26 +/- 4 ml, P < 0.05) decreased. Blood flows to the heart, brain, kidneys and jejunum were maintained. Oxygenation improved and the pulmonary shunt fraction decreased below 10% (HFOV, P < 0.05; PCV, P < 0.05). We detected no differences between HFOV and PCV at comparable transpulmonary pressures. CONCLUSION: A typical recruitment procedure at the initiation of HFOV improved oxygenation but also decreased systemic hemodynamics at high transpulmonary pressures when no changes of vasoactive drugs and fluid management were performed. Blood flow to the organs was not affected during lung recruitment. These effects were independent of the ventilator mode applied.
Resumo:
PURPOSE: We studied the effects of reorganization and changes in the care process, including use of protocols for sedation and weaning from mechanical ventilation, on the use of sedative and analgesic drugs and on length of respiratory support and stay in the intensive care unit (ICU). MATERIALS AND METHODS: Three cohorts of 100 mechanically ventilated ICU patients, admitted in 1999 (baseline), 2000 (implementation I, after a change in ICU organization and in diagnostic and therapeutic approaches), and 2001 (implementation II, after introduction of protocols for weaning from mechanical ventilation and sedation), were studied retrospectively. RESULTS: Simplified Acute Physiology Score II (SAPS II), diagnostic groups, and number of organ failures were similar in all groups. Data are reported as median (interquartile range).Time on mechanical ventilation decreased from 18 (7-41) (baseline) to 12 (7-27) hours (implementation II) (P = .046), an effect which was entirely attributable to noninvasive ventilation, and length of ICU stay decreased in survivors from 37 (21-71) to 25 (19-63) hours (P = .049). The amount of morphine (P = .001) and midazolam (P = .050) decreased, whereas the amount of propofol (P = .052) and fentanyl increased (P = .001). Total Therapeutic Intervention Scoring System-28 (TISS-28) per patient decreased from 137 (99-272) to 113 (87-256) points (P = .009). Intensive care unit mortality was 19% (baseline), 8% (implementation I), and 7% (implementation II) (P = .020). CONCLUSIONS: Changes in organizational and care processes were associated with an altered pattern of sedative and analgesic drug prescription, a decrease in length of (noninvasive) respiratory support and length of stay in survivors, and decreases in resource use as measured by TISS-28 and mortality.
Resumo:
OBJECTIVE: Neurally adjusted ventilatory assist uses the electrical activity of the diaphragm (EAdi)-a pneumatically-independent signal-to control the timing and pressure of the ventilation delivered, and should not be affected by leaks. The aim of this study was to evaluate whether NAVA can deliver assist in synchrony and proportionally to EAdi after extubation, with a leaky non-invasive interface. DESIGN AND SETTING: Prospective, controlled experimental study in an animal laboratory. ANIMALS: Ten rabbits, anesthetized, mechanically ventilated. INTERVENTIONS: Following lung injury, the following was performed in sequential order: (1) NAVA delivered via oral endotracheal tube with PEEP; (2) same as (1) without PEEP; (3) non-invasive NAVA at unchanged NAVA level and no PEEP via a single nasal prong; (4) no assist; (5) non-invasive NAVA at progressively increasing NAVA levels. MEASUREMENTS AND RESULTS: EAdi, esophageal pressure, blood gases and hemodynamics were measured during each condition. For the same NAVA level, the mean delivered pressure above PEEP increased from 3.9[Symbol: see text]+/-[Symbol: see text]1.4[Symbol: see text]cmH(2)O (intubated) to 7.5[Symbol: see text]+/-[Symbol: see text]3.8[Symbol: see text]cmH(2)O (non-invasive) (p[Symbol: see text]<[Symbol: see text]0.05) because of increased EAdi. No changes were observed in PaO(2) and PaCO(2). Increasing the NAVA level fourfold during non-invasive NAVA restored EAdi and esophageal pressure swings to pre-extubation levels. Triggering (106[Symbol: see text]+/-[Symbol: see text]20[Symbol: see text]ms) and cycling-off delays (40[Symbol: see text]+/-[Symbol: see text]21[Symbol: see text]ms) during intubation were minimal and not worsened by the leak (95[Symbol: see text]+/-[Symbol: see text]13[Symbol: see text]ms and 33[Symbol: see text]+/-[Symbol: see text]9[Symbol: see text]ms, respectively). CONCLUSION: NAVA can be effective in delivering non-invasive ventilation even when the interface with the patient is excessively leaky, and can unload the respiratory muscles while maintaining synchrony with the subject's demand.
Resumo:
BACKGROUND: The objective of this study was to review the effects of adjunctive corticosteroids on overall mortality and the need for mechanical ventilation in HIV-infected patients with Pneumocystis jiroveci pneumonia (PCP) and substantial hypoxemia (arterial oxygen partial pressure <70 mmHg or alveolar-arterial gradient >35 mmHg on room air). METHODS: We conducted a systematic search of the literature for randomised trials published up to December 2004. Selected trials compared adjunctive corticosteroids with placebo or usual care in HIV-infected patients with PCP and reported mortality data. Two teams of reviewers independently evaluated the methodology and extracted data from each primary study. RESULTS: Six studies were included in the meta-analysis. Risk ratios for overall mortality for adjunctive corticosteroids were 0.54 (95% confidence interval [CI], 0.38-0.79) at 1 month and 0.67 (95% CI, 0.49-0.93) at 3-4 months of follow-up. Numbers needed to treat, to prevent 1 death, are 9 patients in a setting without highly active antiretroviral therapy (HAART) available and 22 patients with HAART available. Only the 3 largest trials provided data on the need for mechanical ventilation with a risk ratio of 0.37 (95% CI, 0.20-0.70) in favour of adjunctive corticosteroids. CONCLUSION: The number and size of trials investigating adjunctive corticosteroids for HIV-infected patients with PCP is small, but our results suggest a beneficial effect for patients with substantial hypoxemia.
Resumo:
BACKGROUND: The Anesthetic Conserving Device (AnaConDa) uncouples delivery of a volatile anesthetic (VA) from fresh gas flow (FGF) using a continuous infusion of liquid volatile into a modified heat-moisture exchanger capable of adsorbing VA during expiration and releasing adsorbed VA during inspiration. It combines the simplicity and responsiveness of high FGF with low agent expenditures. We performed in vitro characterization of the device before developing a population pharmacokinetic model for sevoflurane administration with the AnaConDa, and retrospectively testing its performance (internal validation). MATERIALS AND METHODS: Eighteen females and 20 males, aged 31-87, BMI 20-38, were included. The end-tidal concentrations were varied and recorded together with the VA infusion rates into the device, ventilation and demographic data. The concentration-time course of sevoflurane was described using linear differential equations, and the most suitable structural model and typical parameter values were identified. The individual pharmacokinetic parameters were obtained and tested for covariate relationships. Prediction errors were calculated. RESULTS: In vitro studies assessed the contribution of the device to the pharmacokinetic model. In vivo, the sevoflurane concentration-time courses on the patient side of the AnaConDa were adequately described with a two-compartment model. The population median absolute prediction error was 27% (interquartile range 13-45%). CONCLUSION: The predictive performance of the two-compartment model was similar to that of models accepted for TCI administration of intravenous anesthetics, supporting open-loop administration of sevoflurane with the AnaConDa. Further studies will focus on prospective testing and external validation of the model implemented in a target-controlled infusion device.
Resumo:
OBJECTIVE: The objective of the study is to compare the clinical, microbiological and host-derived effects in the non-surgical treatment of initial peri-implantitis with either adjunctive local drug delivery (LDD) or adjunctive photodynamic therapy (PDT) after 12 months. MATERIALS AND METHODS: Forty subjects with initial peri-implantitis, that is, pocket probing depths (PPD) 4-6 mm with bleeding on probing (BoP) and radiographic bone loss ≤2 mm, were randomly assigned to two treatment groups. All implants were mechanically debrided with titanium curettes and with a glycine-based powder airpolishing system. Implants in the test group (N = 20) received adjunctive PDT, whereas minocycline microspheres were locally delivered into the peri-implant pockets of control implants (N = 20). At sites with residual BoP, treatment was repeated after 3, 6, 9 and 12 months. The primary outcome variable was the change in the number of peri-implant sites with BoP. Secondary outcome variables included changes in PPD, clinical attachment level (CAL), mucosal recession (REC) and in bacterial counts and crevicular fluid (CF) levels of host-derived biomarkers. RESULTS: After 12 months, the number of BoP-positive sites decreased statistically significantly (P < 0.05) from baseline in both groups (PDT: 4.03 ± 1.66-1.74 ± 1.37, LDD: 4.41 ± 1.47-1.55 ± 1.26). A statistically significant (P < 0.05) decrease in PPD from baseline was observed at PDT-treated sites up to 9 months (4.19 ± 0.55 mm to 3.89 ± 0.68 mm) and up to 12 months at LDD-treated sites (4.39 ± 0.77 mm to 3.83 ± 0.85 mm). Counts of Porphyromonas gingivalis and Tannerella forsythia decreased statistically significantly (P < 0.05) from baseline to 6 months in the PDT and to 12 months in the LDD group, respectively. CF levels of IL-1β decreased statistically significantly (P < 0.05) from baseline to 12 months in both groups. No statistically significant differences (P > 0.05) were observed between groups after 12 months with respect to clinical, microbiological and host-derived parameters. CONCLUSIONS: Non-surgical mechanical debridement with adjunctive PDT was equally effective in the reduction of mucosal inflammation as with adjunctive delivery of minocycline microspheres up to 12 months. Adjunctive PDT may represent an alternative approach to LDD in the non-surgical treatment of initial peri-implantitis.
Resumo:
PURPOSE Thoracic ultrasound (TUS) has been successfully used in the diagnosis of community-acquired pneumonia. Little is known about its diagnostic potential in ventilator-associated pneumonia (VAP). The purpose of this study was to systematically describe the morphology and temporal changes of sonographic patterns in mechanically ventilated patients and to evaluate the diagnostic performance characteristics of TUS-based VAP diagnoses. MATERIALS AND METHODS Patients who were placed on invasive ventilation for reasons other than pneumonia and who were considered at risk for the development of VAP received daily TUS examinations while being closely monitored for the development of pneumonia. RESULTS Fifty-seven patients were studied. The incidence of VAP was 21.1%. Sonographic patterns of reduced or absent lung aeration were found in 64.2% of examinations. The sonographic pattern of lung consolidation with either dynamic or static air bronchograms was 100% sensitive and 60% specific for VAP in those patients who developed clinical signs and symptoms compatible with pneumonia. The pretest and posttest probabilities were 0.38 and 0.6, respectively. CONCLUSIONS Sonographic patterns of abnormal aeration are frequently observed in mechanically ventilated patients. If sonographic lung consolidation with either static or dynamic air bronchograms is absent, VAP is highly unlikely. The presence of these sonographic patterns in patients with signs and symptoms suggestive of pneumonia significantly increases the probability of VAP.
Resumo:
BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.
Resumo:
Trauma is a leading cause of death worldwide, and is thus a major public health concern. Improving current resuscitation strategies may help to reduce morbidity and mortality from trauma, and clinical research plays an important role in addressing these issues. This thesis is a secondary analysis of data that was collected for a randomized clinical trial being conducted at Ben Taub General Hospital. The trial is designed to compare a hypotensive resuscitation strategy to standard fluid resuscitation for the early treatment of trauma patients in hemorrhagic shock. This thesis examines the clinical outcomes from the first 90 subjects enrolled in the study, with the primary aim of assessing the safety of hypotensive resuscitation within the trauma population. ^ Patients in hemorrhagic shock who required emergent surgery were randomized to one of two arms of the study. Those in the experimental (LMAP) arm were managed with a hypotensive resuscitation strategy in which the target mean arterial pressure was 50mmHg. Those in the control (HMAP) arm were managed with standard fluid resuscitation to a target mean arterial pressure of 65mmHg. Patients were followed for 30 days. Mortality, post-operative complications, and other clinical data were prospectively gathered by the Ben Taub surgical staff and then secondarily analyzed for the purpose of this thesis.^ Subjects in the LMAP group had significantly lower early post-operative mortality compared to those in the HMAP group. 30-day mortality was also lower in the LMAP group, although this did not reach statistical significance. There were no statistically significant differences between the two groups with regards to development of ischemic, hematologic or infectious complications, length of hospitalization, length of ICU stay or duration of mechanical ventilation. ^ Based upon the data presented in this thesis, it appears that hypotensive resuscitation is a safe strategy for use in the trauma population. Specifically, hypotensive resuscitation reduced the risk of early post-operative death from coagulopathic bleeding and did not result in an increased risk of ischemic or other post-operative complications. The preliminary results described in this thesis provide convincing evidence support the continued investigation and use of hypotensive resuscitation in a trauma setting.^
Resumo:
Objective: To explore the natural trajectory of core body temperature (CBT) and cortisol (CORT) circadian rhythms in mechanically ventilated intensive care unit (MV ICU) patients. ^ Design: Prospective, observational, time-series pilot study. ^ Setting: Medical-surgical and pulmonary ICUs in a tertiary care hospital. ^ Sample: Nine (F = 3, M = 6) adults who were mechanically ventilated within 12 hrs of ICU admission with mean ± SD age of 65.2 ± 14 years old. ^ Measurements: Core body temperature and environmental measures of light, sound, temperature, and relative humidity were logged in 1-min intervals. Hourly urine specimens and 2-hr interval blood specimens were collected for up to 7 consecutive days for CORT assay. Mechanical ventilation days, ICU length of stay, and ICU mortality were documented. Acute Physiology and Chronic Health Evaluation (APACHE) II scores were computed for each study day. The data of each biologic and environmental variable were analyzed using single cosinor analysis of 24-hr serial segments. One patient did not complete the study because mortality occurred within 8 hrs of enrollment. Nine ICU patients completed the study in 1.6 to 7.0 days. ^ Results: No normal circadian rhythm pattern was found when the cosinor-derived parameters of amplitude (one-half the peak-trough variability) and acrophase (peak time) were compared with cosinor-derived parameter reference ranges of healthy, diurnally active humans, although 83% of patient-day CBT segments showed statistically significant (p ≤ .05) and biologically meaningful (R2≥ 0.30) 24-hr rhythms with abnormal cosinor parameters. Cosinor parameters of the environmental temporal profiles showed 27% of light, 76% of ambient temperature, and 78% of relative humidity serial segments had a significant and meaningful 24-hr diurnal pattern. Average daily light intensity varied from 34 to 187 lx with a maximum light exposure of 1877 lx. No sound measurement segment had a statistically significant cosine pattern, and numerous 1-minute interval peaks ≥ 60 dB occurred around the clock. Average daily ambient temperature and relative humidity varied from 19 to 24°C and from 25% to 61%, respectively. There was no statistically significant association between CBT or clinical outcomes and cosinor-derived parameters of the environmental variables. Circadian rhythms of urine and plasma CORT were deferred for later analysis. ^ Conclusions: The natural trajectory of the CBT circadian rhythm in MV ICU patients demonstrated persistent cosinor parameter alteration, even when a significant and meaningful 24-hr rhythm was present. The ICU environmental measures showed erratic light and sound exposures. Room temperature and relative humidity data produced the highest rate of significant and meaningful diurnal 24-hr patterns. Additional research is needed to clarify relations among the CBT biomarker of the circadian clock and environmental variables of MV ICU patients. ^
Resumo:
Varying concentrations of helium-oxygen (heliox) mixtures were evaluated in mechanically ventilated children with bronchiolitis. We hypothesized that, with an increase in the helium:oxygen ratio, and therefore a decrease in gas density, ventilation and oxygenation would improve in children with bronchiolitis. Ten patients, aged 1-9 months, were mechanically ventilated in synchronized intermittent mandatory ventilation (SIMV) mode with the following gas mixtures delivered at 15-min intervals: 50%/50% nitrogen/oxygen, 50%/50% heliox, 60%/40% heliox, 70%/30% heliox, and return to 50%/50% nitrogen/oxygen. The use of different heliox mixtures compared with 50%/50% nitrogen/oxygen in mechanically ventilated children with bronchiolitis did not result in a significant or noticeable decrease in ventilation or oxygenation.
Resumo:
BACKGROUND One-lung ventilation during thoracic surgery is associated with hypoxia-reoxygenation injury in the deflated and subsequently reventilated lung. Numerous studies have reported volatile anesthesia-induced attenuation of inflammatory responses in such scenarios. If the effect also extends to clinical outcome is yet undetermined. We hypothesized that volatile anesthesia is superior to intravenous anesthesia regarding postoperative complications. METHODS Five centers in Switzerland participated in the randomized controlled trial. Patients scheduled for lung surgery with one-lung ventilation were randomly assigned to one of two parallel arms to receive either propofol or desflurane as general anesthetic. Patients and surgeons were blinded to group allocation. Time to occurrence of the first major complication according to the Clavien-Dindo score was defined as primary (during hospitalization) or secondary (6-month follow-up) endpoint. Cox regression models were used with adjustment for prestratification variables and age. RESULTS Of 767 screened patients, 460 were randomized and analyzed (n = 230 for each arm). Demographics, disease and intraoperative characteristics were comparable in both groups. Incidence of major complications during hospitalization was 16.5% in the propofol and 13.0% in the desflurane groups (hazard ratio for desflurane vs. propofol, 0.75; 95% CI, 0.46 to 1.22; P = 0.24). Incidence of major complications within 6 months from surgery was 40.4% in the propofol and 39.6% in the desflurane groups (hazard ratio for desflurane vs. propofol, 0.95; 95% CI, 0.71 to 1.28; P = 0.71). CONCLUSIONS This is the first multicenter randomized controlled trial addressing the effect of volatile versus intravenous anesthetics on major complications after lung surgery. No difference between the two anesthesia regimens was evident.
Resumo:
Objective: To investigate the effect of standing with assistance of the tilt table on ventilatory parameters and arterial blood gases in intensive care patients. Design: Consecutive sample. Setting: Tertiary referral hospital. Participants: Fifteen adult patients who had been intubated and mechanically ventilated for more than 5 days (3 subjects successfully weaned, 12 subjects being weaned). Intervention: Passive tilting to 70degrees from the horizontal for 5 minutes using a tilt table. Main Outcome Measures: Minute ventilation (VE), tidal volume (VT), respiratory rate, and arterial partial pressure of oxygen (Pao(2)) and carbon dioxide (Paco(2)). Results: Standing in the tilted position for 5 minutes produced significant increases in VE (P
Resumo:
To examine the effect of an algorithm-based sedation guideline developed in a North American intensive care unit (ICU) on the duration of mechanical ventilation of patients in an Australian ICU. The intervention was tested in a pre-intervention, post-intervention comparative investigation in a 14-bed adult intensive care unit. Adult mechanically ventilated patients were selected consecutively (n =322) The pre-intervention and post-intervention groups were similar except for a higher number of patients with a neurological diagnosis in the pre-intervention group. An algorithm-based sedation guideline including a sedation scale was introduced using a multifaceted implementation strategy. The median duration of ventilation was 5.6 days in the post-intervention group, compared with 4.8 days for the pre-intervention group (P = 0.99). The length of stay was 8.2 days in the post-intervention group versus 7.1 days in the pre-intervention group (P = 0.04). There were no statistically significant differences for the other secondary outcomes, including the score on the Experience of Treatment in ICU 7 item questionnaire, number of tracheostomies and number of self-extubations. Records of compliance to recording the sedation score during both phases revealed that patients were slightly more deeply sedated when the guideline was used. The use of the algorithm-based sedation guideline did not reduce duration of mechanical ventilation in the setting of this study.