994 resultados para Universal newborn hearing screening


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Literature data are not conclusive as to the influence of neonatal complications in the maturational process of the auditory system observed by auditory brainstem response (ABR) in infants at term and preterm. Objectives Check the real influence of the neonatal complications in infants by the sequential auditory evaluation. Methods Historical cohort study in a tertiary referral center. A total of 114 neonates met inclusion criteria: treatment at the Universal Neonatal Hearing Screening Program of the local hospital; at least one risk indicator for hearing loss; presence in both evaluations (the first one after hospital discharge from the neonatal unit and the second one at 6 months old); all latencies in ABR and transient otoacoustic emissions present in both ears. Results The complications that most influenced the ABR findings were Apgar scores less than 6 at 5 minutes, gestational age, intensive care unit stay, peri-intraventricular hemorrhage, and mechanical ventilation. Conclusion Sequential auditory evaluation is necessary in premature and term newborns with risk indicators for hearing loss to correctly identify injuries in the auditory pathway.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To validate a monitoring questionnaire about hearing and language development applied by community health agents in the first year of life. Methods: Seventy six community health agents, previously trained on infant hearing health, administered a questionnaire to the families of 304 children with ages from 0 to 1 year. The questionnaire contains questions regarding hearing and language development and, for all age groups, the question “Does your child hear well?” was presented. The validity of the questionnaire was assessed by analyzing false positive and false negative rates of the identified children. A double-blind study was conducted so that all children assessed by the questionnaire were submitted to hearing evaluation performed by audiologists. Results: Four children (1.32%) were diagnosed with sensorineural hearing loss (two unilateral), and 69 (22.7%) with conductive hearing loss. The monitoring questionnaire showed specificity of 96% and sensitivity of 67%, with a false-negative rate of 33% for not identifying the unilateral hearing loss, and a false-positive rate of 4%. Conclusion: The questionnaire used has shown to be feasible and relevant to actions of the community health agents of the Family Health Strategy program, with high specificity and moderate sensitivity. The use of the validated instrument should be considered to complement Newborn Hearing Screening Programs, in order to identify late onset or acquired hearing loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Analisar os motivos da evasão familiar no programa de triagem auditiva neonatal realizado em um hospital público e correlacioná-los com a distribuição demográfica das famílias e as características do programa. MÉTODOS: Participaram 132 famílias, de um total de 739 contatadas, cujos filhos nasceram em uma maternidade no interior do estado de São Paulo de outubro/2003 a dezembro/2005 e que não haviam comparecido para a realização do teste ou reteste da triagem auditiva neonatal. Foi aplicado um questionário de levantamento das causas de evasão, contendo perguntas relacionadas à triagem auditiva, nível de escolaridade e profissão dos pais e também sobre a audição e o desenvolvimento de linguagem da criança. RESULTADOS: Realizou-se a aplicação do questionário com 132 famílias (17,86%); com as demais não foi obtido contato. Deste total, 82 haviam faltado na primeira etapa da triagem auditiva (teste) e 50 não haviam retornado para realização do reteste. Os motivos mais frequentes para justificar a evasão foram o desinteresse e a dificuldade em conciliar o agendamento com a rotina familiar. Não houve associação entre os motivos da evasão e o nível de escolaridade e ocupação dos pais, nem com o profissional que realizou a orientação acerca da triagem auditiva. Não foi referido nenhum caso de alteração auditiva, nem de atraso significativo no desenvolvimento da linguagem. CONCLUSÃO: Os motivos da evasão familiar independem de variáveis voltadas à família e à dinâmica do programa de triagem auditiva.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O Rastreio Universal da Audição Neonatal tem sido um objectivo que várias gerações de audiologistas, otorrinolaringologistas e pediatras tem tentado ao longo dos anos. Os autores fazem uma revisão dos principais métodos utilizados para a avaliação da audição dos recém-nascidos, bem como das dificuldades encontradas e limitações da sua utilização. Desde o inicio da década de noventa vêm a ser implementados verdadeiros métodos de detecção precoce e universal da surdez infantil, utilizando métodos fisiológicos tais como os potenciais evocados auditivos e as otoemissões acústicas (c1ássicos e automáticos). São descritos os artigos mais importantes que fundamentam a necessidade de diagnóstico e intervenção precoces na surdez sensorioneural, com vista a melhorar a aquisição e desenvolvimento da fala e da competência linguística, o que permite uma melhor integração da criança, independentemente do seu grau de surdez. São também enunciadas as directivas do "European Consensus Development on Neonatal Hearing Screening" e do "Joint Comitee on Infant Hearing".

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dr James Reilly, Minister for Health requested the Health Service Executive to review the policy regarding the retention and disposal of Newborn Screening Cards (NSCs). The NSCs are an integral component of the National Newborn Bloodspot Screening Programme (NNBSP). The Minister had received representations concerning the archived NSCs stored by the National Newborn Bloodspot Screening Laboratory (NNBSL) at the Childrenâ?Ts University Hospital, Temple Street (CUH, T/S).   Click here to download PDF 146kb

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biotinidase deficiency is an inherited metabolic disorder characterized by neurological and cutaneous symptoms. Fortunately, it can be treated and the symptoms prevented by oral administration of the vitamin biotin. Using dried blood-soaked filter paper cards, biotinidase activity was determined in the sera of 225,136 newborns in Brazil. Mutation analysis performed on DNA from 21 babies with low serum biotinidase activity confirmed that 3 had profound biotinidase deficiency (less than 10% of mean normal sera biotinidase activity), 10 had partial biotinidase deficiency (10 to 30% of mean normal serum activity), 1 was homozygous for partial biotinidase deficiency, 4 were heterozygous for either profound or partial deficiency, and 3 were normal. Variability in serum enzyme activities and discrepancies with mutation analyses were probably due to inappropriate handling and storage of samples sent to the laboratory. Obtaining an appropriate control serum at the same time as that of the suspected child will undoubtedly decrease the false-positive rate (0.09%). Mutation analysis can be used to confirm the genotype of these children. The estimated incidence of biotinidase deficiency in Brazil is about 1 in 9,000, higher than in most other countries. Screening and treatment of biotinidase deficiency are effective and warranted. These results strongly suggest that biotinidase deficiency should be included in the newborn mass screening program of Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the test performance of distortion product otoacoustic emissions (DPOAEs) when used as a screening tool in the school setting. A total of 1003 children (mean age 6.2 years, SD = 0.4) were tested with pure-tone screening, tympanometry, and DPOAE assessment. Optimal DPOAE test performance was determined in comparison with pure-tone screening results using clinical decision analysis. The results showed hit rates of 0.86, 0.89, and 0.90, and false alarm rates of 0.52, 0.19, and 0.22 for criterion signal-to-noise ratio (SNR) values of 4, 5, and 11 dB at 1.1, 1.9, and 3.8 kHz respectively. DPOAE test performance was compromised at 1.1 kHz. In view of the different test performance characteristics across the frequencies, the use of a fixed SNR as a pass criterion for all frequencies in DPOAE assessments is not recommended. When compared to pure tone plus tympanometry results, the DPOAEs showed deterioration in test performance, suggesting that the use of DPOAEs alone might miss children with subtle middle ear dysfunction. However, when the results of a test protocol, which incorporates both DPOAEs and tympanometry, were used in comparison with the gold standard of pure-tone screening plus tympanometry, test performance was enhanced. In view of its high performance, the use of a protocol that includes both DPOAEs and tympanometry holds promise as a useful tool in the hearing screening of schoolchildren, including difficult-to-test children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although screening for elevated blood pressure (BP) in adults is beneficial, evidence of its beneficial effects in children is not clear. Elevated BP in children is associated with atherosclerosis early in life and tracks across the life course. However, because of the high variability in BP, tracking is weak, and having an elevated BP in childhood has a low predictive value for having elevated BP later in life. The absolute risk of cardiovascular diseases associated with a given level of BP in childhood and the long-term effect of treatment beginning in childhood are not known. No study has experimentally evaluated the benefits and harm of BP screening in children. One modeling study indicates that BP screen-and-treat strategies in adolescents are moderately cost-effective but less cost-effective than population-wide interventions to decrease BP for the reduction of coronary heart diseases. The US National Heart, Lung, and Blood Institute and the European Society of Hypertension recommend that children 3 years of age and older have their BP measured during every health care visit. According to the US Preventive Services Task Force, there is no sufficient evidence to recommend for or against screening, but their recommendations have to be updated. Whether the benefits of universal BP screening in children outweigh the harm has to be determined. Studies are needed to assess the absolute risk of cardiovascular diseases associated with elevated BP in childhood, to evaluate how to simplify the identification of elevated BP, to evaluate the long-term benefits and harm of treatment beginning in childhood, and to compare universal and targeted screening strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When the US Preventive Services Task Force (USPSTF) in 2009 recommended against universal breast cancer screening with mammography in women aged 40 to 49 years, some scientists, radiologists, politicians, and patients strongly objected. The controversy has been called the "mammography wars." The latest chapter in these wars comes from the Swiss Medical Board, which is mandated by the Conference of Health Ministers of the Swiss Cantons, the Swiss Medical Association, and the Swiss Academy of Medical Sciences to conduct health technology assessments. In a February 2014 report, the Swiss Medical Board stated that new systematic mammography screening programs should not be introduced, irrespective of the age of the women, and that existing programs should be discontinued. The board's main argument was that the absolute reduction in breast cancer mortality was low and that the adverse consequences of the screening were substantial. The absolute risk reduction in breast cancer mortality has been estimated by the board at 0.16% for women screened during 6.2 years and followed-up over 13 years, based on the results of a recent Cochrane Review. The adverse consequences include falsepositive test results, overdiagnosis and overtreatment of patients, and high costs, including the expense of follow-up testing and procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of cystic fibrosis (CF) is often delayed because of the nonspecificity of a wide variety of clinical symptoms at disease onset. Newborn screening for CF has been advocated to reduce delays in diagnosis, facilitating preventive care for early respiratory and nutritional involvement. According to American and European consensus and experience of existing programs, a Swiss Nationwide Cystic Fibrosis Newborn Screening Program started in January 2011. Screening strategy combines two steps: an immunoreactive trypsinogen assay and DNA mutation analysis in dried blood samples at day 4 (Guthrie cards).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare published guidelines concerning screening for gestational diabetes. STUDY DESIGN: Systematic search and comparative analysis of published guidelines. Appraisal of guidelines quality. Simulation analysis. RESULTS: Ten published guidelines proposed either universal screening (5), selective screening (3) or screening when clinically indicated (2). Variations of testing schedules and blood glucose thresholds were observed. The quality of the published guidelines was low, on average 22 (8-51) percentage points on the assessment scale. These differences would have led to large variations in the number of patients to be screened. CONCLUSIONS: Large variations between guidelines have been observed which would translate in large practice variations, if the guidelines were systematically applied. These variations are partially explained by the absence of definite evidence that universal or selective screening for gestational diabetes do more good than harm on infant and maternal health. The methodology of developing guidelines should be more evidence based, systematic and explicit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screening people without symptoms of disease is an attractive idea. Screening allows early detection of disease or elevated risk of disease, and has the potential for improved treatment and reduction of mortality. The list of future screening opportunities is set to grow because of the refinement of screening techniques, the increasing frequency of degenerative and chronic diseases, and the steadily growing body of evidence on genetic predispositions for various diseases. But how should we decide on the diseases for which screening should be done and on recommendations for how it should be implemented? We use the examples of prostate cancer and genetic screening to show the importance of considering screening as an ongoing population-based intervention with beneficial and harmful effects, and not simply the use of a test. Assessing whether screening should be recommended and implemented for any named disease is therefore a multi-dimensional task in health technology assessment. There are several countries that already use established processes and criteria to assess the appropriateness of screening. We argue that the Swiss healthcare system needs a nationwide screening commission mandated to conduct appropriate evidence-based evaluation of the impact of proposed screening interventions, to issue evidence-based recommendations, and to monitor the performance of screening programmes introduced. Without explicit processes there is a danger that beneficial screening programmes could be neglected and that ineffective, and potentially harmful, screening procedures could be introduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the prevalence of occult hearing loss in elderly inpatients, to evaluate feasibility of opportunistic hearing screening and to determine subsequent provision of hearing aids. Materials and methods: Subjects (>65 years) were recruited from five elderly care wards. Hearing loss was detected by a ward-based hearing screen comprising patient-reported assessment of hearing disability and a whisper test. Subjects failing the whisper test or reporting hearing difficulties were offered formal audiological assessment. Results: Screening was performed on 51 patients aged between 70 and 95 years. Of the patients, 21 (41%) reported hearing loss and 16 (31%) failed the whisper test. A total of 37 patients (73%) were referred for audiological assessment with 17 (33%) found to have aidable hearing loss and 11 were fitted with hearing aids (22%). Discussion: This study highlights the high prevalence of occult hearing loss in elderly inpatients. Easy two-step screening can accurately identify patients with undiagnosed deafness resulting in significant proportions receiving hearing aids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Approximately 1.6 per 1,000 newborns in the U.S. are born with hearing loss. Congenital hearing loss poses a risk to their speech, language, cognitive, and social-emotional development. Early detection and intervention can improve outcomes. Every state has an Early Hearing Detection and Intervention program (EHDI) to promote and track screening, audiological assessments and linkage to early intervention. However, a large percentage of children are “lost to system (LTS),” meaning that they did not receive recommended care or that it was not reported. This study used data from the 2009-2010 National Survey of Children with Special Health Care Needs and data from the 2011 EHDI Hearing Screening and Follow-Up Survey to examine how 1) family characteristics; 2) EHDI program effectiveness, as determined by LTS percentages; and 3) the family conditions of education and poverty are related to parental report of inadequate care. The sample comprised 684 children between the ages of 0 and 5 years with hearing loss. The results indicated that living in states with less effective EHDI programs was associated with an increased likelihood of not receiving early intervention services (EIS) and of reporting poor family-centered communication. Sibling classification was associated with both receipt of EIS and report of unmet need. Single mothers were less likely to report increased difficulties accessing care. Poor and less educated families, assessed separately, who lived in states with less effective EHDI programs, were more likely to report non-receipt of EIS and less likely to report unmet need as compared to similar families living in states with more effective programs. Poor families living in states with less effective programs were more likely to report less coordinated care than were poor families living in states with more effective programs. This study supports the conclusion that both family characteristics and the effectiveness of state programs affect quality of care outcomes. It appears that less effective state programs affect disadvantaged families’ service receipt report more than that of advantaged families. These findings are important because they may provide insights into the development of targeted efforts to improve the system of care for children with hearing loss.