963 resultados para Uniformity.
Resumo:
A study is presented of the effects of temperature non-uniformity in a distributed temperature sensor based on the temperature dependence of Brillouin gain in an optical fibre. The form of the Brillouin gain profile for a given temperature distribution is measured and successfully modelled.
Resumo:
A study is presented of the effects of temperature non-uniformity in a distributed temperature sensor based on the temperature dependence of Brillouin gain in an optical fibre. The form of the Brillouin gain profile for a given temperature distribution is measured and successfully modelled.
Resumo:
Using the resource-based view framework, we investigate the link between multiunit franchising (MUF) and performance on four key challenges in franchise chain management: growth, uniformity, local responsiveness, and system-wide adaptation. Our findings support the assertion that system growth is positively related to MUF rate within a system, in particular in relation to geographic expansion. Interestingly, while uniformity does not seem to be related to MUF rate, we find marginal support for an inverted u-shaped relationship between system-wide adaptation and MUF rate. Furthermore, the data suggest that local responsiveness and MUF rate are related in a u-shaped function.
Resumo:
Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, Lamisil® (terbinafine) and Proscar® (finasteride), in split tablet dosage form. Methods: Thirty tablets each of the 2 studied medications were randomly selected. Tablets were weighed and divided into 3 groups. Ten tablets of each drug were kept intact, another group of 10 tablets were manually split into halves using a tablet cutter and weighed with an analytical balance; a third group were split into quarters and weighed. All intact and split tablets were individually dissolved in a water: methanol mixture (4:1), sonicated, filtered and further diluted with mobile phase. Optimal chromatographic separation and mass spectrometric detection were achieved using an Agilent 1200 HPLC system coupled with an Agilent 6410 triple quadrupole mass spectrometer. Analytes were eluted through an Agilent eclipse plus C8 analytical column (150 mm × 4.6 mm, 5 μm) with a mobile phase composed of solvent A (water) containing 0.1% formic acid and 5mM ammonium formate pH 7.5, and solvent B (acetonitrile mixed with water in a ratio A:B 55:45) at a flow rate of 0.8 mL min-1 with a total run time of 12 min. Mass spectrometric detection was carried out using positive ionization mode with analyte quantitation monitored by multiple reaction monitoring (MRM) mode. Results: The proposed analytical method proved to be specific, robust and adequately sensitive. The results showed a good linear fit over the concentration range of 20 - 100 ng mL-1 for both analytes, with a correlation coefficient (r2) ≥ 0.999 and 0.998 for finasteride and terbinafine, respectively. Following tablet splitting, the drug content of the split tablets fell outside of the proxy USP specification for at least 14 halves (70 %) and 34 quarters (85 %) of FIN, as well as 16 halves (80 %) and 37 quarters (92.5 %) of TBN. Mean weight loss, after splitting, was 0.58 and 2.22 % for FIN half- and quarter tablets, respectively, and 3.96 and 4.09 % for TBN half- and quarter tablets,respectively. Conclusion: The proposed LC-MS/MS method has successfully been used to provide precise drug content uniformity of split tablets of FIN and TBN. Unequal distribution of the drug on the split tablets is indicated by the high standard deviation beyond the accepted value. Hence, it is recommended not to split non-scored tablets especially, for those medications with significant toxicity
Resumo:
Mode of access: Internet.
Resumo:
BACKGROUND: This project addressed an unresolved issue involving measurement methods for determining step uniformity. Leading experts on stairway safety agree that lack of step uniformity within a flight contributes to risk of missteps. A relatively new method for precisely measuring step dimensions is the nosing-to-nosing method. An issue in applying the method is lack of agreement on the lateral location to make the measurements. That location depends on where stairway users ascend and descend relative to the width of the steps. A prior investigator examined people descending to determine the lateral distance between the handrail center and the mid-line of the person’s body. He found the median was 44 cm. AIM: The two objectives of the experiment were to: (1) determine if a different set of stairway users will have the same median lateral distance from the handrail as those described in the prior observational study, and (2) determine if the lateral distance of participants is affected by their direction of travel and use of a handrail. METHODS: The investigators established visible distance markers on one stairway in a campus building and videotaped volunteer students ascending and descending the flight of stairs. Each of the 16 participant ascended with and without using the handrail, and each descended with and without using the handrail. Images were printed and analyzed to determine their lateral distance between the inner edge of the handrail and a point midway between the participant’s knees. Results were analyzed statistically to test hypotheses corresponding to the two objectives. RESULTS: The previous study found a median lateral distance of 44 cm when measured from the center of the handrail. Using comparable data, the median found in this study was 25 cm. Results of this study indicated that lateral distance from the handrail is significantly affected by the direction of travel and by use of the handrail. The greatest lateral distance was for ascending with the handrail. The shortest lateral distance was for descending without the handrail. VALUE: Committees develop and periodically revise standards for stairways leading to fire exits and workplace facilities. The practical value of this project is providing empirical evidence that standard developing committees may consider when convening to update their requirements and guidelines on how to measure step uniformity.
Resumo:
The objective of this study is to identify the optimal designs of converging-diverging supersonic and hypersonic nozzles that perform at maximum uniformity of thermodynamic and flow-field properties with respect to their average values at the nozzle exit. Since this is a multi-objective design optimization problem, the design variables used are parameters defining the shape of the nozzle. This work presents how variation of such parameters can influence the nozzle exit flow non-uniformities. A Computational Fluid Dynamics (CFD) software package, ANSYS FLUENT, was used to simulate the compressible, viscous gas flow-field in forty nozzle shapes, including the heat transfer analysis. The results of two turbulence models, k-e and k-ω, were computed and compared. With the analysis results obtained, the Response Surface Methodology (RSM) was applied for the purpose of performing a multi-objective optimization. The optimization was performed with ModeFrontier software package using Kriging and Radial Basis Functions (RBF) response surfaces. Final Pareto optimal nozzle shapes were then analyzed with ANSYS FLUENT to confirm the accuracy of the optimization process.
Resumo:
Property taxes serve as a vital revenue source for local governments. The revenues derived from the property tax function as the primary funding source for a variety of critical local public service systems. Property tax appeal systems serve as quasi-administrative-judicial mechanisms intended to assure the public that property tax assessments are correct, fair, and equitable. Despite these important functions, there is a paucity of empirical research related to property tax appeal systems. This study contributes to property tax literature by identifying who participates in the property tax appeal process and examining their motivations for participation. In addition, the study sought to determine whether patterns of use and success in appeal systems affected the distribution of the tax burden. Data were collected by means of a survey distributed to single-family property owners from two Florida counties. In addition, state and county documents were analyzed to determine appeal patterns and examine the impact on assessment uniformity, over a three-year period. The survey data provided contextual evidence that single-family property owners are not as troubled by property taxes as they are by the conduct of local government officials. The analyses of the decision to appeal indicated that more expensive properties and properties excluded from initial uniformity analyses were more likely to be appealed, while properties with homestead exemptions were less likely to be appealed. The value change analyses indicated that appeals are clustered in certain geographical areas; however, these areas do not always experience a greater percentage of the value changes. Interestingly, professional representation did not increase the probability of obtaining a reduction in value. Other relationships between the variables were discovered, but often with weak predictive ability. Findings from the assessment uniformity analyses were also interesting. The results indicated that the appeals mechanisms in both counties improved assessment uniformity. On average, appealed properties exhibited greater horizontal and vertical inequities, as compared to non-appealed properties, prior to the appeals process. After, the appeal process was completed; the indicators of horizontal and vertical equity were largely improved. However, there were some indications of regressivity in the final year of the study.
Resumo:
2016
Resumo:
Spaces without northerly orientations have an impact on the ‘energy behaviour’ of a building. This paper outlines possible energy savings and better performance achieved by different zenithal solar passive strategies (skylights, roof monitors and clerestory roof windows) and element arrangements across the roof in zones of cold to temperate climates typical of the central and central-southern Argentina. Analyses were undertaken considering daylighting, thermal and ventilation performances of the different strategies. The results indicate that heating,ventilation and lighting loads in spaces without an equator-facing facade can be significantly reduced by implementing solar passive strategies. In the thermal aspect, the solar saving fraction reached for the different strategies were averaged 43.16% for clerestories, 41.4% for roof monitors and 38.86% for skylights for a glass area of 9% to the floor area. The results also indicate average illuminance levels above 500 lux for the different clerestory and monitor arrangements, uniformity ratios of 0.66–0.82 for the most distributed arrangements and day-lighting factors between 11.78 and 20.30% for clear sky conditions, depending on the strategy. In addition, minimum air changes rates of 4 were reached for the most extreme conditions.
Resumo:
In a typical large office block, by far the largest lifetime expense is the salaries of the workers - 84% for salaries compared with : office rent (14%), total energy (1%), and maintenance (1%). The key drive for business is therefore the maximisation of the productivity of the employees as this is the largest cost. Reducing total energy use by 50% will not produce the same financial return as 1% productivity improvement? The aim of the project which led to this review of the literature was to understand as far as possible the state of knowledge internationally about how the indoor environment of buildings does influence occupants and the impact this influence may have on the total cost of ownership of buildings. Therefore one of the main focus areas for the literature has been identifying whether there is a link between productivity and health of building occupants and the indoor environment. Productivity is both easy to define - the ratio of output to input - but at the same time very hard to measure in a relatively small environment where individual contributions can influence the results, in particular social interactions. Health impacts from a building environment are also difficult to measure well, as establishing casual links between the indoor environment and a particular health issue can be very difficult. All of those issues are canvassed in the literature reported here. Humans are surprisingly adaptive to different physical environments, but the workplace should not test the limits of human adaptability. Physiological models of stress, for example, accept that the body has a finite amount of adaptive energy available to cope with stress. The importance of, and this projects' focus on, the physical setting within the integrated system of high performance workplaces, means this literature survey explores research which has been undertaken on both physical and social aspects of the built environment. The literature has been largely classified in several different ways, according to the classification scheme shown below. There is still some inconsistency in the use of keywords, which is being addressed and greater uniformity will be developed for a CD version of this literature, enabling searching using this classification scheme.
Resumo:
This article reports an enhanced solvent casting/particulate (salt) leaching (SCPL) method developed for preparing three-dimensional porous polyurethane (PU) scaffolds for cardiac tissue engineering. The solvent for the preparation of the PU scaffolds was a mixture of dimethylformamide (DFM) and tetrahydrofuran (THF). The enhanced method involved the combination of a conventional SCPL method and a step of centrifugation, with the centrifugation being employed to improve the pore uniformity and the pore interconnectivity of scaffolds. Highly porous three-dimensional scaffolds with a well interconnected porous structure could be achieved at the polymer solution concentration of up to 20% by air or vacuum drying to remove the solvent. When the salt particle sizes of 212-295, 295-425, or 425-531 µm and a 15% w/v polymer solution concentration were used, the porosity of the scaffolds was between 83-92% and the compression moduli of the scaffolds were between 13 kPa and 28 kPa. Type I collagen acidic solution was introduced into the pores of a PU scaffold to coat the collagen onto the pore walls throughout the whole PU scaffold. The human aortic endothelial cells (HAECs) cultured in the collagen-coated PU scaffold for 2 weeks were observed by scanning electron microscopy (SEM). It was shown that the enhanced SCPL method and the collagen coating resulted in a spatially uniform distribution of cells throughout the collagen-coated PU scaffold.
Resumo:
Synthetic polymers have attracted much attention in tissue engineering due to their ability to modulate biomechanical properties. This study investigated the feasibility of processing poly(varepsilon-caprolactone) (PCL) homopolymer, PCL-poly(ethylene glycol) (PEG) diblock, and PCL-PEG-PCL triblock copolymers into three-dimensional porous scaffolds. Properties of the various polymers were investigated by dynamic thermal analysis. The scaffolds were manufactured using the desktop robot-based rapid prototyping technique. Gross morphology and internal three-dimensional structure of scaffolds were identified by scanning electron microscopy and micro-computed tomography, which showed excellent fusion at the filament junctions, high uniformity, and complete interconnectivity of pore networks. The influences of process parameters on scaffolds' morphological and mechanical characteristics were studied. Data confirmed that the process parameters directly influenced the pore size, porosity, and, consequently, the mechanical properties of the scaffolds. The in vitro cell culture study was performed to investigate the influence of polymer nature and scaffold architecture on the adhesion of the cells onto the scaffolds using rabbit smooth muscle cells. Light, scanning electron, and confocal laser microscopy showed cell adhesion, proliferation, and extracellular matrix formation on the surface as well as inside the structure of both scaffold groups. The completely interconnected and highly regular honeycomb-like pore morphology supported bridging of the pores via cell-to-cell contact as well as production of extracellular matrix at later time points. The results indicated that the incorporation of hydrophilic PEG into hydrophobic PCL enhanced the overall hydrophilicity and cell culture performance of PCL-PEG copolymer. However, the scaffold architecture did not significantly influence the cell culture performance in this study.