915 resultados para Total hip arthroplasty revision surgery · tabular reconstruction · Bone loss · Ceramics
Resumo:
Several mechanisms have been postulated as potentially involved in life-threatening complications during cemented surgery. In this study, we evaluated the role of anaphylaxis and pulmonary fat embolism in the pathophysiology of bone cement implantation syndrome in a series of fatal cases that underwent medicolegal investigations. Postmortem findings in these cases were compared with those obtained from individuals who died after other injuries and/or interventions and in which activated mast cells and pulmonary fat embolism were involved in the pathogenesis of death. Fifty subjects were selected including 6 individuals who had undergone cemented total hip arthroplasty and died intraoperatively, 32 subjects who died shortly after being involved in traffic accidents, 8 individuals who died shortly after the injection of contrast material, and 4 subjects who had undergone orthopedic surgery and died postoperatively. Massive pulmonary fat embolism was determined to be the cause of death in all the 6 subjects who died intraoperatively as well as the main cause of death in traffic-road victims with rapid respiratory function deterioration. Mast cell activation was identified exclusively in the group of subjects who died shortly after contrast material administration. Massive pulmonary fat embolism appears to be the most important factor responsible for severe cardiorespiratory function deterioration during cemented arthroplasty. Cardiac comorbidities can also significantly influence the severity of intraoperative complications, thus corroborating the hypothesis of a multifactorial model in the pathogenesis of bone cement implantation syndrome.
Resumo:
Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.
Resumo:
HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.
Resumo:
BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.
Resumo:
BACKGROUND: Articular surfaces reconstruction is essential in total shoulder arthroplasty. Because of the limited glenoid bone support, thin glenoid component could improve anatomical reconstruction, but adverse mechanical effects might appear. METHODS: With a numerical musculoskeletal shoulder model, we analysed and compared three values of thickness of a typical all-polyethylene glenoid component: 2, 4 (reference) and 6mm. A loaded movement of abduction in the scapular plane was simulated. We evaluated the humeral head translation, the muscle moment arms, the joint force, the articular contact pattern, and the polyethylene and cement stress. Findings Decreasing polyethylene thickness from 6 to 2mm slightly increased humeral head translation and muscle moment arms. This induced a small decreased of the joint reaction force, but important increase of stress within the polyethylene and the cement mantel. Interpretation The reference thickness of 4mm seems a good compromise to avoid stress concentration and joint stuffing.
Resumo:
After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
Resumo:
OBJECTIVE: to characterize the epidemiological profile of patients undergoing hip replacement, primary or revisional. METHODS: we conducted a retrospective, descriptive study, including hip arthroplasties performed from January 2009 to June 2012 in a Belo Horizonte teaching hospital, Minas Gerais State - MG, Brazil. Data were analyzed using descriptive statistics. RESULTS: orthopedic procedures represented 45% of the operations at the hospital in the period, 1.4% hip arthroplasties. There were 125 hip replacements, 85 total, 27 partial and 13 reviews. Among the patients, 40% were male and 60% were female. Age ranged between 20 and 102 years, mean and median of 73 and 76 years, respectively. The most frequent diagnosis (82%) was femoral neck fracture by low-energy trauma caused by falling form standing position. In 13 revision operations, 12 required removal of the prosthesis. The infectious complication led to revision in 54% of the time, followed by dislocation (15%), peri-prosthetic fracture (15%) and aseptic loosening (15%). The infection etiologic agent was identified in 43% of occasions. The average length of the prosthesis to a revision operation was eight months. CONCLUSION: patients undergoing hip arthroplasty are elderly, with femoral neck fracture caused by falling form standing position, affecting more women. The incidence of hip prosthesis loosening was 10%. The main cause of the infection was loosening. The incidence of revisional hip arthroplasty was 10% and the incidence of hospital mortality in patients undergoing hip arthroplasty was 7.2%.
Resumo:
The puqjose of this study was to examine the manner in which an inviting approach to a preoperative teaching and learning educational experience influenced the perception and subsequent recovery of clients who were awaiting total hip and total knee replacement surgery. An in-depth review of the internal and external factors that shape client perceptions was undertaken in this study. In addition, this study also explored whether or not the Prehab Program was preparing clients physically, socially, and psychologically for surgery. Data for this qualitative case study research were collected through preoperative interviews with 4 participants awaiting total hip replacement surgery and 1 participant awaiting total knee replacement surgery. Four postoperative interviews were conducted with the participants who had received total hip replacement surgery. The occupational therapist and physical therapist who were the coleaders of the Prehab Program at the time of this study were also interviewed. The results of this study suggest that while individuals may receive similar educational experiences, their perceptions of the manner in which they benefited from these experiences varied. This is illustrated in the research findings, which concluded that while clients benefited physically from the inviting approach used during the practical teaching session, not all clients perceived the psychological benefits of this practice session, especially clients with preexisting high levels of anxiety. In addition to increasing the understanding of the internal as well as external factors that influence the perceptions of clients, this study has also served as an opportunity for reflection on practice for the Prehab therapists and other healthcare educators.
Resumo:
Introducción Los Grupos Relacionados de Diagnóstico (GRD) se han usado para determinar la calidad de la atención en varios sistemas de salud. Esto ha llevado a que se obtengan resultados en el mejoramiento continuo de la atención y del cuidado. El objetivo de este estudio es determinar desenlaces clínicos de los pacientes a quienes se les había realizado reemplazo de articulares según la complejidad clínica definida mediante GRD. Métodos Se realizó un estudio longitudinal descriptivo en el cual se incluyeron todos los pacientes que tuvieron cirugía de reemplazo total de hombro, cadera y rodilla entre 2012 y 2014. Se realizó la estratificación de los pacientes de acuerdo a tres niveles de complejidad dados por el sistema de GRD y se determinaron las proporciones de pacientes para las variables de estancia hospitalaria, enfermedad trombo-embólica, cardiovascular e infección del sitio operatorio. Resultados Se realizaron en total 886 reemplazos articulares de los cuales 40 (4.5%) presentaron complicaciones. Los eventos más frecuentes fueron las complicaciones coronarias, con una presencia de 2.4%. El GRD1, sin complicaciones ni comorbilidades, fue el que presentó mayor número de eventos. La estancia hospitalaria fue de 3.8 a 9.3 días para todos los reemplazos. Conclusiones Contrario a lo planteado en la hipótesis de estudio, se encontró que el primer GRD presentó el mayor número de complicaciones, lo que puede estar relacionado con el tamaño del grupo. Es necesario realizar nuevas investigaciones que soporten el uso de los GRD como herramienta para evaluar desenlaces clínicos.
Resumo:
O presente estudo é uma coorte não concorrente em 63 pacientes (66 quadris) submetidos à revisão de artroplastia total de quadril (RATQ), com enxerto ósseo liofilizado moído e impactado. Foi realizado no Serviço de Ortopedia e Traumatologia do Hospital de Clínicas de Porto Alegre (HCPA), no período de maio de 1997 a setembro de 2003. O objetivo do estudo foi comparar clínica, radiográfica e cintilograficamente a capacidade de osteointegração dos enxertos ósseos liofilizados humano e bovino impactados em RATQs cimentadas e não-cimentadas. Os pacientes foram divididos em dois grupos: o Grupo 1 (n=35) foi composto pelos que receberam enxerto ósseo liofilizado de origem humana e o Grupo 2 (n=31) por aqueles que receberam enxerto de origem bovina. O tempo médio de seguimento foi de 33 meses. Os enxertos ósseos purificados e liofilizados foram produzidos pelo Banco de Tecidos do HCPA. A análise clínica baseou-se no escore de Merle, d’Aubigné e Postel; a radiográfica, nos critérios de radioluscência, densidade, formação de trabeculado ósseo, migração dos componentes e floculação, formulando-se um escore radiográfico de osteointegração (EROI). Foram escolhidos, aleatoriamente, como forma complementar de análise por imagem, 35 (53%) pacientes assintomáticos para realizarem cintilografia óssea com Tecnécio, sendo 17 (48,5%) do Grupo 1 e 18 (51,5%) do Grupo 2. Não foram encontradas diferenças clínicas, radiográficas ou cintilográficas relevantes entre os grupos, obtendo-se em torno de 85% de integração do enxerto, tanto no componente acetabular quanto femoral. Estes resultados são comparáveis aos relatados na literatura com o uso de enxerto alogênico congelado e confirmam a adequacidade do uso de enxertos liofilizados de origem bovina e humana em RATQ.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
OBJECTIVE: To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. METHODS: Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: <60, 61 to 90, 91 to 120, and >120 minutes. Three categories were defined for operative time: <120, 121 to 150, and >150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. RESULTS: In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. CONCLUSION: We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.
Resumo:
The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.
Resumo:
We report a series of 16 consecutive total knee arthroplasty (TKA) revision procedures for deep infection, treated with a newly developed intraoperatively moulded PMMA cement-prostheses-like spacer (CPLS). The standard treatment consisted of a two-stage protocol with initial explantation of the infected components combined with radical debridement, followed by implantation of a temporary cement spacer and final reimplantation of a new TKA. A sterilizeable Teflon tapered aluminium mould was developed for production of a custom made CPLS during the intervention. Stable implantation of the CPLS was achieved with a second cementation, allowing for correct alignment and ligament balancing. The spacer remained 3.5 months on average until reimplantation of a TKA occurred. At time of reimplantation, patients had an average KSS score of 84.44 points with an average flexion capacity of 102°. There was no recurrent infection during the study period of minimum 2 years. With this new technique, a low friction articulation with good stability, high comfort and a better range of motion compared to handcrafted spacers was achieved. The use of this spacer is a time sparing, cheap and convenient option in 2-stage TKA revision.