931 resultados para Total Knee Replacement Surgery, Orthopaedics
Resumo:
PURPOSE: Currently, many pre-conditions are regarded as relative or absolute contraindications for lumbar total disc replacement (TDR). Radiculopathy is one among them. In Switzerland it is left to the surgeon's discretion when to operate if he adheres to a list of pre-defined indications. Contraindications, however, are less clearly specified. We hypothesized that, the extent of pre-operative radiculopathy results in different benefits for patients treated with mono-segmental lumbar TDR. We used patient perceived leg pain and its correlation with physician recorded radiculopathy for creating the patient groups to be compared. METHODS: The present study is based on the dataset of SWISSspine, a government mandated health technology assessment registry. Between March 2005 and April 2009, 577 patients underwent either mono- or bi-segmental lumbar TDR, which was documented in a prospective observational multicenter mode. A total of 416 cases with a mono-segmental procedure were included in the study. The data collection consisted of pre-operative and follow-up data (physician based) and clinical outcomes (NASS form, EQ-5D). A receiver operating characteristic (ROC) analysis was conducted with patients' self-indicated leg pain and the surgeon-based diagnosis "radiculopathy", as marked on the case report forms. As a result, patients were divided into two groups according to the severity of leg pain. The two groups were compared with regard to the pre-operative patient characteristics and pre- and post-operative pain on Visual Analogue Scale (VAS) and quality of life using general linear modeling. RESULTS: The optimal ROC model revealed a leg pain threshold of 40 ≤ VAS > 40 for the absence or the presence of "radiculopathy". Demographics in the resulting two groups were well comparable. Applying this threshold, the mean pre-operative leg pain level was 16.5 points in group 1 and 68.1 points in group 2 (p < 0.001). Back pain levels differed less with 63.6 points in group 1 and 72.6 in group 2 (p < 0.001). Pre-operative quality of life showed considerable differences with an 0.44 EQ-5D score in group 1 and 0.29 in group 2 (p < 0.001, possible score range -0.6 to 1). At a mean follow-up time of 8 months, group 1 showed a mean leg pain improvement of 3.6 points and group 2 of 41.1 points (p < 0.001). Back pain relief was 35.6 and 39.1 points, respectively (p = 0.27). EQ-5D score improvement was 0.27 in group 1 and 0.41 in group 2 (p = 0.11). CONCLUSIONS: Patients labeled as having radiculopathy (group 2) do mostly have pre-operative leg pain levels ≥ 40. Applying this threshold, the patients with pre-operative leg pain do also have more severe back pain and a considerably lower quality of life. Their net benefit from the lumbar TDR is higher and they do have similar post-operative back and leg pain levels as well as the quality of life as patients without pre-operative leg pain. Although randomized controlled trials are required to confirm these findings, they put leg pain and radiculopathy into perspective as absolute contraindications for TDR.
Total knee arthroplasty - a clinical and numerical study of the micromovements of the tibial implant
Resumo:
Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.
Resumo:
Rheumatoid arthritis is an autoimmune disease that may affect multiple joints, both small and large, and leads to numerous complications. The standard surgical treatment for a rheumatoid arthritic ankle has been an arthrodesis. The ideal candidate for an ankle replacement in a rheumatoid patient is one who is moderately active, has a well-aligned ankle and heel, and a fair range of motion in the ankle joint. Good surgical technique and correction of any hindfoot deformity will result in satisfactory alignment of the ankle with regard to the mechanical axis, and this will lead to increased prosthetic longevity.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to develop instruments to quantitatively assess the soft-tissue balance since excessive imbalance can accelerate prosthesis wear and lead to early surgical revision. The instrumented distractor proposed in this study can assist surgeons on performing ligament balance by measuring the distraction gap and applied load. Also the device allows the determination of the ligament stiffness which can contribute a better understanding of the intrinsic mechanical behavior of the knee joint. Instrumentation of the device involved the use of hall-sensors for measuring the distractor displacement and strain gauges to transduce the force. The sensors were calibrated and tested to demonstrate their suitability for surgical use. Results show the distraction gap can be measured reliably with 0.1mm accuracy and the distractive loads could be assessed with an accuracy in the range of 4N. These characteristics are consistent with those have been proposed, in this work, for a device that could assist on performing ligament balance while permitting surgeons evaluation based on his experience. Preliminary results from in vitro tests were in accordance with expected stiffness values for medial collateral ligament (MCL) and lateral collateral ligament (LCL).
Resumo:
Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.
Resumo:
Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.
Resumo:
Previous studies assessed the outcome of ankle arthrodesis (AA) and total ankle replacement (TAR) surgeries; however, the extent of postoperative recovery towards bilateral gait mechanics (BGM) is unknown. We evaluated the outcome of the two surgeries at least 2 years post rehabilitation, focusing on BGM. 36 participants, including 12 AA patients, 12 TAR patients, and 12 controls were included. Gait assessment over 50 m distance was performed utilizing pressure insoles and 3D inertial sensors, following which an intraindividual comparison was performed. Most spatiotemporal and kinematic parameters in the TAR group were indicative of good gait symmetry, while the AA group presented significant differences. Plantar pressure symmetry among the AA group was also significantly distorted. Abnormality in biomechanical behavior of the AA unoperated, contralateral foot was observed. In summary, our results indicate an altered BGM in AA patients, whereas a relatively fully recovered BGM is observed in TAR patients, despite the quantitative differences in several parameters when compared to a healthy population. Our study supports a biomechanical assessment and rehabilitation of both operated and unoperated sides after major surgeries for ankle osteoarthrosis.
Resumo:
AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.
Resumo:
Infection is one of the most serious complications after total knee arthroplasty (TKA). The current incidence of prosthetic knee infection is 1-3%, depending on the series(.) For treatment and control to be more cost effective, multidisciplinary groups made up of professionals from different specialities who can work together to eradicate these kinds of infections need to be assembled. About the microbiology, Staphylococcus aureus and coagulase-negative staphylococcus were among the most frequent microorganisms involved (74%). Anamnesis and clinical examination are of primary importance in order to determine whether the problem may point to a possible acute septic complication. The first diagnosis may then be supported by increased CRP and ESR levels. The surgical treatment for a chronic prosthetic knee infection has been perfectly defined and standardized, and consists in a two-stage implant revision process. In contrast, the treatment for acute prosthetic knee infection is currently under debate. Considering the different surgical techniques that already exist, surgical debridement with conservation of the prosthesis and polythene revision appears to be an attractive option for both surgeon and patient, as it is less aggressive than the two-stage revision process and has lower initial costs. The different results obtained from this technique, along with prognosis factors and conclusions to keep in mind when it is indicated for an acute prosthetic infection, whether post-operative or haematogenous, will be analysed by the authors.
Resumo:
Introducción Los Grupos Relacionados de Diagnóstico (GRD) se han usado para determinar la calidad de la atención en varios sistemas de salud. Esto ha llevado a que se obtengan resultados en el mejoramiento continuo de la atención y del cuidado. El objetivo de este estudio es determinar desenlaces clínicos de los pacientes a quienes se les había realizado reemplazo de articulares según la complejidad clínica definida mediante GRD. Métodos Se realizó un estudio longitudinal descriptivo en el cual se incluyeron todos los pacientes que tuvieron cirugía de reemplazo total de hombro, cadera y rodilla entre 2012 y 2014. Se realizó la estratificación de los pacientes de acuerdo a tres niveles de complejidad dados por el sistema de GRD y se determinaron las proporciones de pacientes para las variables de estancia hospitalaria, enfermedad trombo-embólica, cardiovascular e infección del sitio operatorio. Resultados Se realizaron en total 886 reemplazos articulares de los cuales 40 (4.5%) presentaron complicaciones. Los eventos más frecuentes fueron las complicaciones coronarias, con una presencia de 2.4%. El GRD1, sin complicaciones ni comorbilidades, fue el que presentó mayor número de eventos. La estancia hospitalaria fue de 3.8 a 9.3 días para todos los reemplazos. Conclusiones Contrario a lo planteado en la hipótesis de estudio, se encontró que el primer GRD presentó el mayor número de complicaciones, lo que puede estar relacionado con el tamaño del grupo. Es necesario realizar nuevas investigaciones que soporten el uso de los GRD como herramienta para evaluar desenlaces clínicos.
Resumo:
OBJECTIVES: This study sought to analyze the effects of resistance training on functional performance, lower-limb loading distribution and balance in older women with total knee arthroplasty (TKA) and osteoarthritis (OA) in the contralateral knee. In addition, this older knee OA and TKA group (OKG) was compared to older (OG) and young women (YG) without musculoskeletal diseases who underwent the same resistance training program.METHODS: Twenty-three women divided into OKG (N = 7), OG (N = 8) and YG (N = 8) had their functional performance, lower-limb loading distribution and balance compared before and after 13 weeks of a twice-weekly progressive resistance training program.RESULTS: At baseline, the OKG showed lower functional performance and unilateral balance, and impaired lower-limb loading distribution compared to the OG and the YG (p<0.05). After resistance training, the OKG showed improvements in functional performance (similar to 13% in sit-to-stand and rising from the floor, similar to 16% in stair-climbing and similar to 23% in 6-minute walking (6 MW)), unilateral balance (similar to 72% and,78% in TKA and OA leg, respectively) and lower-limb loading distribution, which were greater than those observed in the OG and the YG. The OKG showed post-training 6 MW performance similar to that of the OG at baseline. Sit-to-stand performance and unilateral stand balance were further restored to post-training levels of the OG and to baseline levels of the YG.CONCLUSIONS: Resistance training partially restored functional, balance and lower-limb loading deficits in older women with TKA and OA in the contralateral knee. These results suggest that resistance training may be an important tool to counteract mobility impairments commonly found in this population.