799 resultados para Toric implantable collamer lens
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
A computer-aided method to improve the thickness uniformity attainable when coating multiple substrates inside a thermal evaporation physical vapor deposition unit is presented. The study is developed for the classical spherical (dome-shaped) calotte and also for a plane sector reversible holder setup. This second arrangement is very useful for coating both sides of the substrate, such as antireflection multilayers on lenses. The design of static correcting shutters for both kinds of configurations is also discussed. Some results of using the method are presented as an illustration.
Resumo:
PURPOSE: To investigate the ability of fibroblast growth factor (FGF) 2-saporin to prevent lens regrowth in the rabbit. METHODS: Chemically conjugated and genetically fused FGF2-saporin (made in Escherichia coli) were used. Extracapsular extraction of the lens was performed on the rabbit, and the cytotoxin either was injected directly into the capsule bag or was administered by FGF2-saporin-coated, heparin surface-modified (HSM) polymethylmethacrylate intraocular lenses. The potential of the conjugate was checked by slit lamp evaluation of capsular opacification and by measuring crystallin synthesis. Toxin diffusion and sites of toxin binding were assessed by immunohistochemistry. Possible toxicity was determined by histologic analysis of ocular tissues. RESULTS: FGF2-saporin effectively inhibited lens regrowth when it was injected directly into the capsular bag. However, high concentration of the toxin induced transient corneal edema and loss of pigment in the iris. Intraocular lenses coated with FGF2-saporin reduced lens regrowth and crystallin synthesis without any detectable clinical side effect. After implantation, FGF2-saporin was shown to have bound to the capsules and, to a lesser extent, to the iris; no histologic damage was found on ocular tissues as a result of implantation of drug-loaded HSM intraocular lenses. CONCLUSIONS: Chemically conjugated (FGF2-SAP) and genetically fused FGF2-saporin (rFGF2-SAP) bound to HSM intraocular lenses can prevent lens regrowth in the rabbit.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.
Resumo:
Starting from the early descriptions of Kraepelin and Bleuler, the construct of schizotypy was developed from observations of aberrations in nonpsychotic family members of schizophrenia patients. In contemporary diagnostic manuals, the positive symptoms of schizotypal personality disorder were included in the ultra high-risk (UHR) criteria 20 years ago, and nowadays are broadly employed in clinical early detection of psychosis. The schizotypy construct, now dissociated from strict familial risk, also informed research on the liability to develop any psychotic disorder, and in particular schizophrenia-spectrum disorders, even outside clinical settings. Against the historical background of schizotypy it is surprising that evidence from longitudinal studies linking schizotypy, UHR, and conversion to psychosis has only recently emerged; and it still remains unclear how schizotypy may be positioned in high-risk research. Following a comprehensive literature search, we review 18 prospective studies on 15 samples examining the evidence for a link between trait schizotypy and conversion to psychosis in 4 different types of samples: general population, clinical risk samples according to UHR and/or basic symptom criteria, genetic (familial) risk, and clinical samples at-risk for a nonpsychotic schizophrenia-spectrum diagnosis. These prospective studies underline the value of schizotypy in high-risk research, but also point to the lack of evidence needed to better define the position of the construct of schizotypy within a developmental psychopathology perspective of emerging psychosis and schizophrenia-spectrum disorders.
Resumo:
Mise au point sur le hotter implantable (Reveal®). Connaissances actuelles et implications thérapeutiques. La syncope est un problème fréquent touchant environ un tiers des adultes durant leur vie. C'est un motif de consultation habituel aux urgences et ses causes sont souvent multiples et rendent son diagnostic difficile. Malgré des investigations extensives et coûteuses la cause syncopale reste dans environ 30% des cas d'étiologie indéterminée. Les progrès récents dans le monitoring cardiaque à long terme ont permis d'inclure dans le choix des tests diagnostiques un outil très intéressant dans l'investigation de la syncope d'étiologie indéterminée (SOI). Il s'agit du moniteur ECG implantable (MEI) ou Reveal®. Il y a un peu plus de 10 ans un prototype de MEI a été implanté dans un petit collectif de patients souffrants de SOI récidivantes et a permis d'établir un diagnostic chez la plupart d'entre eux. Dès lors le système s'est modernisé avec une diminution importante de la taille et du poids permettant actuellement d'enregistrer le rythme cardiaque sur une durée de 18 à 24 mois. Le système peut stocker dans sa mémoire un tracé ECG soit à l'aide d'un activateur externe déclenché par le patient, soit de façon spontanée en présence d'un rythme cardiaque lent ou rapide. Son implantation se fait en anesthésie locale, en position sous-cutanée pectorale gauche. Les complications et les problèmes infectieux sont rares. Plusieurs études récentes se sont intéressées à l'apport diagnostique du MEI dans la prise en charge de la SOI. La plus grande porte sur un collectif de 206 patients. L'apport diagnostique des différentes études varie de 40% à 64%. Cependant la plupart de ces études ne comportaient pas de prise en charge standardisée ou avaient des critères d'inclusion précis. Nous nous sommes intéressés aux résultats de notre prise en charge de la syncope au cours de ces 6 dernières années. Une consultation spécialisée de la syncope a été mise en place en 1999. La consultation offre l'accès à tout le plateau technique propre à l'investigation de syncopes à savoir un tilt-test avec mesure continue non invasive de la pression artérielle, examens échocardiographiques et test d'effort. Si nécessaire, le bilan peut être complété par une étude électrophysiologique (EEP) et/ou une coronarographie: Tous les patients bénéficient d'une anamnèse ciblée suivi d'un examen clinique et d'un électrocardiogramme. Une échocardiographie n'est effectuée qu'en cas de suspicion de cardiopathie sous-jacente. Un holter ou R-test ne sont réalisés qu'en présence de syncopes ou palpitations fréquentes. Les investigations se poursuivent par un tilt test suivi d'un massage du sinus carotidien en position debout et couchée. Un test d'hyperventilation n'est pratiqué que chez les patients avec traits phobiques, dépressifs ou troubles de type panique. L'EEP n'est pratiquée que chez les patients dont la syncope reste d'étiologie indéterminée après investigations initiales et chez ceux souffrant d'une cardiopathie sous jacente documentée ; elle est aussi indiquée chez ceux dont le coeur est normal mais chez qui la syncope est associée à des traumatismes ou à l'origine d'un accident de voiture. Le MEI est proposé lorsque toutes les investigations initiales restent négatives, généralement chez les sujets ayant souffert de plus d'une syncope ou de complications sérieuses. Notre expérience pratique d'une consultation de la syncope ouverte au tout venant nous montre qu'une prise en charge standardisée non invasive permet d'identifier une cause syncopale chez plus de 60% des patients. Chez les patients souffrant de syncopes récidivantes ou traumatiques d'étiologie indéterminée après investigations conventionnelles, l'apport diagnostique du MEI est élevé (64%) durant un suivi moyen de 9 mois, ce qui permet d'identifier certaines causes syncopales écartées précédemment par des tests ciblés. Parmi ces dernières, retenons plus particulièrement les tachycardies nodales et crises d'épilepsie.
Resumo:
An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.
Resumo:
Référence bibliographique : Rol, 57365
Resumo:
The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.
Resumo:
PURPOSE: To localize collagen types I, III, and IV, laminin and fibronectin in the anterior human lens capsule. MATERIAL AND METHODS: Twenty-one anterior capsules were sampled by capsulorhexis during extracapsular cataract extraction (mean age 71.5). All capsules were labelled by an immunostaining specific for each antibodies. Immunostaining of four capsules was revealed with immunoperoxydase and seventeen using indirect immunofluorescence. RESULTS: Labelling of collagen types I and III was observed throughout the entire thickness of the capsule for each technique, the strongest labelling was found in the base of the epithelial cells with immunofluorescence. Collagen type IV was observed at the base of the epithelial cells whichever technique was used. Laminin could be detected in the inner layer of the capsule, using immunoperoxydase or immunofluorescence. No specific labelling was found for fibronectin using the two techniques. CONCLUSIONS: Different kinds of collagens have been found in capsules, more particularly the type III. The latter does not appear on other ocular basement membrane. Because of this uneven distribution in the capsule's thickness, each collagen might have a specific function.