899 resultados para Tip Allocation: A Compliance Study for Restaurants
Resumo:
A modelling framework is developed to determine the joint economic and environmental net benefits of alternative land allocation strategies. Estimates of community preferences for preservation of natural land, derived from a choice modelling study, are used as input to a model of agricultural production in an optimisation framework. The trade-offs between agricultural production and environmental protection are analysed using the sugar industry of the Herbert River district of north Queensland as an example. Spatially-differentiated resource attributes and the opportunity costs of natural land determine the optimal tradeoffs between production and conservation for a range of sugar prices.
Resumo:
Background: A combination of antihypertensive agents of different drug classes in a fixed-dose combination (FDC) may offer advantages in terms of efficacy, tolerability, and treatment compliance. Combination of a calcium channel blocker with an angiotensin-converting enzyme inhibitor may act synergistically to reduce blood pressure (BP). Objective: The aim of this study was to compare the efficacy and tolerability of an amlodipine/ramipril FDC with those of amlodipine monotherapy. Methods: This 18-week, prospective, randomized, double-blind study was conducted at 8 centers across Brazil. Patients with stage 1 or 2 essential hypertension were enrolled. After a 2-week placebo run-in phase, patients received amlodipine/ramipril 2.5/2.5 mg or amlodipine 2.5 mg, after which the doses were titrated, based on BP, to 515 then 10/10 mg (amlodipme/ramipril) and 5 then 10 mg (amiodipine). The primary end point was BP measured in the intent-to-treat (ITT) population. Hematology and serum biochemistry were assessed at baseline and study end. Tolerability was assessed using patient interview, laboratory analysis, and physical examination, including measurement of ankle circumference to assess peripheral edema. Results: A total of 222 patients completed the study (age range, 40-79 years; FDC group, 117 patients [mean dose, 7.60/7.60 mg]; monotherapy, 105 patients [mean dose, 7.97 mg]). The mean (SD) changes in systolic BP (SBP) and diastolic BP (DBP), as measured using 24-hour ambulatory blood pressure monitoring (ABPM) and in the physician`s office, were significantly greater with combination therapy than monotherapy, with the exception of office DBP (ABPM, -20.76 [1.25] vs -15.80 [1.18] mm Hg and -11.71 [0.78] vs -8.61 [0.74] mm Hg, respectively [both, P = 0.004]; office, -27.51 [1.40] vs -22.84 [1.33] min Hg [P = 0.012] and -16.41 [0.79] vs -14.64 [0.75] mm Hg [P = NS], respectively). In the ITT analysis, the mean changes in ambulatory, but not office-based, BP were statistically significant (ABPM: SBP, -20.21 [1.14] vs -15.31 [1.12] mm Hg and DBP, -11.61 [0.72] vs -8.42 [0.70] mm Hg, respectively [both, P = 0.002]; office: SBP, -26.60 [1.34] vs -22.97 [1.30] mm Hg and DBP, -16.48 [0.78] vs -14.48 [0.75] mm Hg [both, P = NS]). Twenty-nine patients (22.1%) treated with combination therapy and 41 patients (30.6%) treated with monotherapy experienced >= 1 adverse event considered possibly related to study drug. The combmation-therapy group had lower prevalence of edema (7.6% vs 18.7%; P = 0.011) and a similar prevalence of dry cough (3.8% vs 0.8%; P = NS). No clinically significant changes in laboratory values were found in either group. Conclusions: In this population of patients with essential hypertension, the amlodipine/ramipril FDC was associated with significantly reduced ambulatory and office-measured BP compared with amlodipine monotherapy, with the exception of office DBP. Both treatments were well tolerated. (Clin Ther. 2008;30: 1618-1628) (C) 2008 Excerpta Medica Inc.
Resumo:
Background-The effectiveness of heart failure disease management proarams in patients under cardiologists` care over long-term follow-up is not established. Methods and Results-We investigated the effects of a disease management program with repetitive education and telephone monitoring on primary (combined death or unplanned first hospitalization and quality-of-life changes) and secondary end points (hospitalization, death, and adherence). The REMADHE [Repetitive Education and Monitoring for ADherence for Heart Failure] trial is a long-term randomized, prospective, parallel trial designed to compare intervention with control. One hundred seventeen patients were randomized to usual care, and 233 to additional intervention. The mean follow-up was 2.47 +/- 1.75 years, with 54% adherence to the program. In the intervention group, the primary end point composite of death or unplanned hospitalization was reduced (hazard ratio, 0.64; confidence interval, 0.43 to 0.88; P=0.008), driven by reduction in hospitalization. The quality-of-life questionnaire score improved only in the intervention group (P<0.003). Mortality was similar in both groups. Number of hospitalizations (1.3 +/- 1.7 versus 0.8 +/- 1.3, P<0.0001), total hospital days during the follow-up (19.9 +/- 51 versus 11.1 +/- 24 days, P<0.0001), and the need for emergency visits (4.5 +/- 10.6 versus 1.6 +/- 2.4, P<0.0001) were lower in the intervention group. Beneficial effects were homogeneous for sex, race, diabetes and no diabetes, age, functional class, and etiology. Conclusions-For a longer follow-up period than in previous studies, this heart failure disease management program model of patients under the supervision of a cardiologist is associated with a reduction in unplanned hospitalization, a reduction of total hospital days, and a reduced need for emergency care, as well as improved quality of life, despite modest program adherence over time. (Circ Heart Fail. 2008;1:115-124.)
Resumo:
OBJECTIVES We have evaluated prospectively the long-term efficacy of the artificial urinary sphincter (AUS) AMS 800 for the treatment postradical prostatectomy urinary incontinence (PRPUI) patients. We also evaluated the correlation between preoperative urodynamic findings and surgical outcomes. METHODS From May 1997 to April 2003, 40 consecutive patients with PRPUI caused by intrinsic sphincter deficiency (ISD) were treated with the AMS 800. Mean age was 68.3 +/- 6.3 years. Continence status was evaluated on the basis of pad count, impact of urinary incontinence on the quality of life, complications, and surgical revisions. Preoperative urodynamic findings were correlated with surgical outcomes. RESULTS Follow-up ranged from 27 to 132 months (mean = 53.4 +/- 21.4 months). There was a significant reduction in pad count from 4.0 +/- 0.9 to 0.62 +/- 1.07 diapers per day (P <0.001) leading to continence in 90%. There was a significant reduction on the impact of incontinence decreasing from 5.0 +/- 0.7 to 1.4 +/- 0.93 (P <0.001) in a visual analogue scale (VAS). Surgical revision rate was 20%. Preoperative urodynamics was useful to identify sphincter deficiency. Except by a tendency of worse results in patients with reduced bladder compliance (RBC), other urodynamic parameters did not correlate with a worse surgical outcome. CONCLUSIONS The AMS 800 offers good long-term continence to most PRPUI patients. Preoperative findings like detrusor hyperactivity (DH), impaired detrusor contraction (IDC), low Valsalva leak point pressure, bladder outlet obstruction (BOO), and mild RBC were not associated with worse surgical outcomes.
Resumo:
Background: Current evidence suggests an inverse association between socioeconomic status and stroke incidence. Our aim was to measure the variation in incidence among different city districts (CD) and their association with socioeconomic variables. Methods: We prospectively ascertained all possible stroke cases occurring in the city of Joinville during the period 2005-2007. We determined the incidence for each of the 38 CD, age-adjusted to the population of Joinville. By linear regression analysis, we correlated incidence data with mean years of education (MYE) and mean income per month (MIPM). Results: Of the 1,734 stroke cases registered, 1,034 were first-ever strokes. In the study period, the crude incidence in Joinville was 69.5 per 100,000 (95% confidence interval, 65.3-73.9). The stroke incidence among CD ranged from 37.5 (22.2-64.6) to 151.0 per 100,000 (69.0-286.6). The stroke incidence was inversely correlated with years of education (r = -0.532; p<0.001). MYE and MIPM were strongly related (R = 0.958), resulting in exclusion of MIPM by collinearity. Conclusions: Years of education can explain a wide incidence variation among CD. These results may be useful to guide the allocation of resources in primary prevention policies. Copyright (C) 2011 S. Karger AG, Basel
Resumo:
Psychosocial manifestations of erectile dysfunction (ED) differ across cultures. Understanding the treatment response to ED medications within cultural groups can aid in resource allocation and in developing treatment strategies. Evaluate the effect of sildenafil treatment on self-esteem, confidence, and sexual relationship satisfaction in Brazilian men with ED. The Self-Esteem and Relationship (SEAR) questionnaire, a validated, 14-question instrument developed to specifically address self-esteem and relationship issues within the context of ED. Men aged 18 years or older with a clinical diagnosis of ED (<= 21 on the Sexual Health Inventory for Men) and in a stable relationship with a partner during the study were eligible. The primary end point was a change from baseline in the self-esteem subscale of the SEAR questionnaire. Thirteen Brazilian sites participated in a randomized, double-blind, placebo-controlled trial of sildenafil treatment for ED. Patients were randomized to receive either 50 mg of sildenafil (adjustable to 25 mg or 100 mg based on patient response) or matching placebo approximately 1 hour before anticipated sexual activity but not more than once a day. At the end of double-blind treatment, 63 and 66 patients in the placebo and sildenafil groups, respectively, from 13 Brazilian sites were assessed for efficacy. Brazilian patients receiving sildenafil had significantly greater improvements in their scores on the SEAR self-esteem subscale (42.9 [95% confidence interval 35.7-50.0]) compared with placebo (21.1 [95% confidence interval 13.7-28.6]; P < 0.0001). Effect sizes ranged from 0.91 to 1.25 for individual SEAR components. The psychosocial parameters in Brazilian men with ED assessed by the SEAR questionnaire showed significant improvements in self-esteem, confidence, and relationships after treatment with sildenafil. Glina S, Damiao R, Abdo C, Afif-Abdo J, Tseng L-J, and Stecher V. Self-esteem, confidence, and relationships in Brazilian men with erectile dysfunction receiving sildenafil citrate: A randomized, parallel-group, double-blind, placebo-controlled study in Brazil. J Sex Med 2009;6:268-275.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Background. A variety of techniques can be used to achieve stabilization of femoral valgus osteotomies in children, but what is lacking is a versatile fixation system that associates stability and versatility at different ages and for different degrees of deformity. Methods. Mechanical tests of three configurations used to fix femoral valgus osteotomies, based oil the tension band wire principle, were carried out. A 30 degrees wedge valgus osteotomy was performed at the subtrochanteric level in 60 swine femurs and fixed with three different systems. In Group 1, two Kirschner wires (K wire) were introduced from the tip of the greater trochanter to the medial cortex, crossing the osteotomy. A flexible steel wire was anchored to the K wires into holes in the lateral cortex and tightened to form a tension band. The same setup was used in Group 2, but two additional smooth K wires were inserted into the lateral surface of the greater trochanter and driven to the femoral head with the distal extremities bent and tied around tile bone shaft. In Group 3, the fixation was similar to that in Group 2, but tile ascending K wires were introduced below the osteotomy level, crossing the osteotonly. Mechanical tests in bending-compression and torsion were used to access the stability. Findings. The torsional relative stiffness was 116% greater for Group 3 (0.27 N m/degree) and no significant difference was found between Group 1 (0.10 N m/degree) and Group 2 (0.12 N m/degree). The average torque was 103% higher for Group 3 (1.86 N m). Stiffness in bending-compression was significantly higher in Group 3 (508 x 10(3) N/m) than in Group 1 (211 x 10(3) N/m) and Group 2 (219 x 10(3) N/m). Interpretation. Fixation as used in Group 3 was significantly more stable, both in torsion and bending-compression tests, than tile other two techniques. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.
Resumo:
Aims. The use of hemodialysis temporary dual-lumen catheters is often complicated by infections, which may be a significant cause of death among patients with end stage renal disease (ESRD). The aim of this study was to assess the incidence of bacteremia and bacterial colonization related to non-tunneled, non-cuffed, dual-lumen temporary catheters in patients with ESRD submitted to hemodialysis. Methods. This study included 29 patients with ESRD. After catheter implantation, patients were monitored throughout the period of catheter permanence by means of blood samples collected weekly from a peripheral vein. Bacteria were isolated and identified according to CLSI recommendations. When catheters were removed for any reason, their tips were evaluated microbiologically. Results. A total of 194 blood samples from the 29 patients implanted with 55 catheters were analyzed. Of these, 15.5% (30 samples) demonstrated bacterial growth, principally Staphylococcus epidermidis (64.5%). Twenty patients (68.9%) presented at least one positive blood culture during follow-up. The median time for catheter colonization was 18.5 days (95% CI: 16.8-30.3). Of the 55 catheters implanted, 28 (50.9%) showed bacterial colonization, corresponding to 23.4 episodes/1000 catheter/days and 9.2 episodes of bacteremia /1000 catheter/days. Fifteen of 28 catheter tips analyzed showed bacterial growth (53.5%). In 14 of these (93.3%), there was agreement between the isolates from the catheter tip and blood cultures. Of 24 episodes of positive blood cultures from 20 different patients in 17 episodes (70.8%), the patients showed no clinical signs or symptoms of bacteremia. Conclusions. The high incidence of catheter colonization, the correlation between blood and catheter tip cultures, and the occurrence of frequent cases of asymptomatic bacteremia justify the proposal of routine peripheral blood collections to monitor patients undergoing hemodialysis with temporary dual-lumen catheters.
Resumo:
Aim Stapled haemorrhoidopexy may damage the anorectal musculature and its sensorimotor function. Most studies have not used a barostat for the measurement of compliance. This study aimed to investigate the effect of stapled haemorrhoidopexy on rectal compliance and sensitivity. Method After Ethical Committee approval, we studied 10 male patients (mean age 33.8 years) with third- or fourth-degree haemorrhoids. Rectal compliance and sensitivity were measured with a 600-ml bag and an electronic barostat. Volunteers were submitted to two consecutive rectal distension protocols, including continuous distension at 2, 4 and 6 months after stapled haemorrhoidopexy. Intraluminal volume and pressure were recorded, including the first rectal sensation, desire to defecate and onset of rectal pain. Another group of 10 male control patients (mean age 24.9 years) with pilonidal sinus and no haemorrhoids was also included in the study. Results Two months after stapled haemorrhoidopexy, rectal compliance decreased (7.1 +/- 0.2 vs 5.3 +/- 0.1, 6.4 +/- 0.1 vs 5.1 +/- 0.1 and 5.6 +/- 0.2 vs 4.7 +/- 0.1 ml/mmHg for first rectal sensation, desire to defecate and rectal pain, respectively; P < 0.05). The sensitivity threshold volume did not change for the first sensation but decreased significantly for the desier to defecate and pain (p < 0.05) (116.8 +/- 13.8 vs 148.4 +/- 14.61, 251.1 +/- 8.9 vs 185.8 +/- 8.6 and 293.3 +/- 16.6 vs 221.2 +/- 6.0 ml for first rectal sensation, desire to defecate and rectal pain, respectively). Four and 6 months after surgery, rectal compliance and sensitivity returned to levels similar to those in the basal period. Muscle tissue was found in only three of the 10 resected doughnuts. Controls remained without any change in rectal compliance and sensitivity. Conclusion Stapled haemorrhoidopexy transiently decreases rectal compliance and sensitivity threshold in young male patients.
Resumo:
Kenyan women have more children, especially in rural areas, than in most developing nations. This is widely believed to be an impediment to Kenya’s economic development. Thus, factors influencing family size in the Kenyan context are important for its future. A brief review of economic theories of fertility leads to the conclusion that both economics and social/cultural factors must be considered simultaneously when examining factors that determine the number of children in a family. The need to do this is borne out in Kenya’s situation by utilising responses from a random sample of rural households in the Nyeri district of Kenya. Economic and social/cultural factors intertwine to influence family sizes in this district. After providing a summary of the main statistical results from the survey, we use multiple regression analysis to explore the influences of a woman’s age, level of education, whether she has outside employment, whether the family keeps livestock, whether she expresses a preference for more boys than girls, whether the family uses only family labour (including child labour) and the size of the farm, which is used as a proxy for family income. It was found that preference for male children has an important positive influence on family size in this district. Women were found to have greater preference for male children than their male counterparts possibly because of their fear of being disinherited if they do not produce an heir for their husbands. Preference for sons was also found in allocation of human capital resources at the household level in that the female respondents were found to have lower levels of education than their male counterparts. Various long-term policies are outlined that may help to reduce the number of offspring of women in Kenya.
Resumo:
This article examines the effects of marital status, farm size and other factors on the extent of cash cropping (and allocation of land use) by means of a case study in the Nyeri district in Kenya. It was found that married women are involved in the production of a relatively greater amount of output of cash crops than unmarried women since husbands prefer to have more land under cash crops than food crops. Farmers with better quality land allocate a high proportion of it to non-food cash crops, which may expose some households to greater risks of possible famine. The proportion of land allocated to food crops declines as the farm size increases while the proportion of land allocated to non-food cash crops rises as the size of farm increases. Age is also inversely associated with subsistence. Education, though inversely associated with subsistence farming does not appear to be statistically very significant as an influence on the composition of land use and composition of farm output. With growing commercialisation, married women work more hours than unmarried ones, working not only on non-cash food crops but also on non-food cash crops. Married women seem to lose their decision-making ability with growth of agricultural commercialisation, as husbands make most decisions to do with cash crops. Married women in Kenya also have little or no power to change the way land is allocated between food and non-food cash crops.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
Objective. The aim of this study was to compare GPX instruments and hand files for gutta-percha removal. Study design. Fifty maxillary central incisors with a single straight canal were instrumented and filled. The teeth were divided into 5 groups of 10 specimens each, according to the gutta-percha removal techniques: group 1: GPX (21-mm-long teeth); group 2: GPX and xylol as solvent (21-mm-long teeth); group 3: GPX (25-mm-long teeth); group 4: GPX and xylol as solvent (25-mm-long teeth); and group 5: hand files and xylol as solvent. The amount of time for gutta-percha removal and the number of fractured instruments were evaluated. Radiographs were taken, and the teeth were grooved longitudinally and split. The area of residual debris was measured using Sigma Scan software. Results. The time for filling material removal was significantly shorter when GPX was used (P < .05). Overall, hand files and solvent produced fewer remnants of filling materials (P < .05). In the GPX 25 mm-long teeth group, the filling material was not removed in the apical third. Conclusions. Under the experimental conditions, the GPX instruments proved to be faster than hand instruments in removing root filling materials; however, hand instruments left a smaller amount of residual filling materials on the canal walls. The GPX instruments did not pull the gutta-percha beyond its tip. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 675-680)