986 resultados para Time Resolution


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carbonyl compounds are very important volatil organic compounds receiving increasing attention due to their critical role in tropospheric organic chemistry and to their effects on human health. They are first photo-oxidation stage of almost all organic compounds and originators of free radicals (OH, O3...). Therfore, continuous determination of their atmospheric concentrations is essential. Currently, field measurements are very limited mainly because of the analytical challenges posed by trace concentrations and interferences arising from atmospheric co-pollutants. Additionally, hydroxyl radical (OH) plays a central role in atmospheric chemistry processes. The measurement of atmospheric OH concentrations is essential for the comprehension of atmospheric chemical and photochemical processes. In this context, objectives of this work were: To perform a continuous survey of atmospheric concentrations of carbonyl compounds on different sites around the area of Bologna. For this purpose, an automatic instrument for the continuous measurement (one hour of time resolution) was developed and used. Additionally, the development of a complete and original analytical method was realised. To develop an original OH generation system in order to evaluate the effect of OH and the reactivity of solid and/or liquid materials of interest. This included the validation of an analytical method for the quantification of OH concentrations generated. Effect of OH on ceramic materials and reactivity of snow surface samples, involved as sink of OH in atmospheric chemistry, were evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gegenstand dieser Arbeit ist die Untersuchung von Photokathoden mit negativer Elektronenaffinität (NEA) mittels zeitlich hochauflösender Vermessung der emittierten Ladungs- und Spinpolarisationsverteilungen nach Anregung mit einem ultrakurzen Laserpuls. Untersucht wurden uniaxial deformierte GaAsP-Photokathoden mit dünnen emittierenden Schichten (≤150nm), sowie undeformierte GaAs-Photokathoden mit unterschiedlichen Schichtdicken. Die Untersuchungen wurden an einer 100keV-Elektronenquelle durchgeführt, wie sie am Mainzer Mikrotron (MAMI) zur Erzeugung eines Spinpolarisierten Elektronenstrahls verwendet wird. Mit der Apparatur konnte eine Zeitauflösung von 2,5ps erreicht werden. Es zeigte sich, dass die tatsächliche Antwortzeit der Photokathoden die erreichte Zeitauflösung noch unterschreitet. Eine Depolarisation in den kurzen, wegen der Zeitauflösung auf 2,5ps begrenzten, Elektronenpulsen konnte aber nachgewiesen werden. Weiterhin wurde gezeigt, dass der Polarisationsverlust der emittierten Elektronen bei dünnen Schichten im Wesentlichen auf eine energiekorrelierte Depolarisation beim Durchqueren der Bandbiegungszone zurückzuführen ist. Als weiteres Resultat wird, für die GaAsP-Photokathoden mit einer Schichtdicke von 150nm, eine Obergrenze für die mittlere Emissionszeit von ≤1,25ps angegeben. Daraus ergibt sich nach dem hier verwendeten Diffusionsmodell eine Untergrenze für die Oberflächenrekombinationsgeschwindigkeit an der Bandbiegungszone von S≥1,2·10^7 cm/s.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde die zeitaufgelöste Photoemissions Elektronenmikroskopie (TR-PEEM) für die in-situ Untersuchung ultraschneller dynamischer Prozesse in dünnen mikrostrukturierten magnetischen Schichten während eines rasch verändernden externen Magnetfelds entwickelt. Das Experiment basiert auf der Nutzung des XMCD-Kontrasts (X-ray magnetic circular dichroism) mit Hilfe des zirkularpolarisierten Lichts von Synchrotronstrahlungsquellen (Elektronenspeicherringen BESSY II (Berlin) und ESRF (Grenoble)) für die dynamische Darstellung der magnetischen Domänen während ultraschneller Magnetisierungsvorgänge. Die hier entwickelte Methode wurde als erfolgreiche Kombination aus einer hohen Orts- und Zeitauflösung (weniger als 55 nm bzw. 15 ps) realisiert. Mit der hier beschriebenen Methode konnte nachgewiesen werden, dass die Magnetisierungsdynamik in großen Permalloy-Mikrostrukturen (40 µm x 80 µm und 20 µm x 80 µm, 40 nm dick) durch inkohärente Drehung der Magnetisierung und mit der Bildung von zeitlich abhängigen Übergangsdomänen einher geht, die den Ummagnetisierungsvorgang blockieren. Es wurden neue markante Differenzen zwischen der magnetischen Response einer vorgegebenen Dünnfilm-Mikrostruktur auf ein gepulstes externes Magnetfeld im Vergleich zu dem quasi-statischen Fall gefunden. Dies betrifft die Erscheinung von transienten raumzeitlichen Domänenmustern und besonderen Detailstrukturen in diesen Mustern, welche im quasi-statischen Fall nicht auftreten. Es wurden Beispiele solcher Domänenmuster in Permalloy-Mikrostrukturen verschiedener Formen und Größen untersucht und diskutiert. Insbesondere wurde die schnelle Verbreiterung von Domänenwänden infolge des präzessionalen Magnetisierungsvorgangs, die Ausbildung von transienten Domänenwänden und transienten Vortizes sowie die Erscheinung einer gestreiften Domänenphase aufgrund der inkohärenten Drehung der Magnetisierung diskutiert. Ferner wurde die Methode für die Untersuchung von stehenden Spinwellen auf ultradünnen (16 µm x 32 µm groß und 10 nm dick) Permalloy-Mikrostrukturen herangezogen. In einer zum periodischen Anregungsfeld senkrecht orientierten rechteckigen Mikrostruktur wurde ein induziertes magnetisches Moment gefunden. Dieses Phänomen wurde als „selbstfangende“ Spinwellenmode interpretiert. Es wurde gezeigt, dass sich eine erzwungene Normalmode durch Verschiebung einer 180°-Néelwand stabilisiert. Wird das System knapp unterhalb seiner Resonanzfrequenz angeregt, passt sich die Magnetisierungsverteilung derart an, dass ein möglichst großer Teil der durch das Anregungsfeld eingebrachten Energie im System verbleibt. Über einem bestimmten Grenzwert verursacht die Spinwellenmode nahe der Resonanzfrequenz eine effektive Kraft senkrecht zur 180°-Néel-Wand. Diese entsteht im Zentrum der Mikrostruktur und wird durch die streufeldinduzierte Kraft kompensiert. Als zusätzliche Möglichkeit wurden die Streufelder von magnetischen Mikrostrukturen während der dynamischen Prozesse quantitativ bestimmt und das genaue zeitliche Profil des Streufelds untersucht. Es wurde gezeigt, dass das zeitaufgelöste Photoemissions Elektronenmikroskop als ultraschnelles oberflächensensitives Magnetometer eingesetzt werden kann.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present thesis introduces a novel sensitive technique based on TSM resonators that provides quantitative information about the dynamic properties of biological cells and artificial lipid systems. In order to support and complement results obtained by this method supplementary measurements based on ECIS technique were carried out. The first part (chapters 3 and 4) deals with artificial lipid systems. In chapter 3 ECIS measurements were used to monitor the adsorption of giant unilamellar vesicles as well as their thermal fluctuations. From dynamic Monte Carlo Simulations the rate constant of vesicle adsorption was determined. Furthermore, analysis of fluctuation measurements reveals Brownian motion reflecting membrane undulations of the adherent liposomes. In chapter 4 QCM-based fluctuation measurements were applied to quantify nanoscopically small deformations of giant unilamellar vesicles with an external electrical field applied simultaneously. The response of liposomes to an external voltage with shape changes was monitored as a function of cholesterol content and adhesion force. In the second part (chapters 5 - 8) attention was given to cell motility. It was shown for the first time, that QCM can be applied to monitor the dynamics of living adherent cells in real time. QCM turned out to be a highly sensitive tool to detect the vertical motility of adherent cells with a time resolution in the millisecond regime. The response of cells to environmental changes such as temperature or osmotic stress could be quantified. Furthermore, the impact of cytochalasin D (inhibits actin polymerization) and taxol (facilitate polymerization of microtubules) as well as nocodazole (depolymerizes microtubules) on the dynamic properties of cells was scrutinized. Each drug provoked a significant reduction of the monitored cell shape fluctuations as expected from their biochemical potential. However, not only the abolition of fluctuations was observed but also an increase of motility due to integrin-induced transmembrane signals. These signals were activated by peptides containing the RGD sequence, which is known to be an integrin recognition motif. Ultimately, two pancreatic carcinoma cell lines, derived from the same original tumor, but known to possess different metastatic potential were studied. Different dynamic behavior of the two cell lines was observed which was attributed to cell-cell as well as cell-substrate interactions rather than motility. Thus one may envision that it might be possible to characterize the motility of different cell types as a function of many variables by this new highly sensitive technique based on TSM resonators. Finally the origin of the broad cell resonance was investigated. Improvement of the time resolution reveals the "real" frequency of cell shape fluctuations. Several broad resonances around 3-5 Hz, 15-17 Hz and 25-29 Hz were observed and that could unequivocally be assigned to biological activity of living cells. However, the kind of biological process that provokes this synchronized collective and periodic behavior of the cells remains to be elucidated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this thesis the analysis to reconstruct the transverse momentum p_{t} spectra for pions, kaons and protons identified with the TOF detector of the ALICE experiment in pp Minimum Bias collisions at $\sqrt{s}=7$ TeV was reported. After a detailed description of all the parameters which influence the TOF PID performance (time resolution, calibration, alignment, matching efficiency, time-zero of the event) the method used to identify the particles, the unfolding procedure, was discussed. With this method, thanks also to the excellent TOF performance, the pion and kaon spectra can be reconstructed in the 0.5

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work is to investigate the evaporation dynamics of water microdrops deposited on atomic force microscope cantilevers, which were employed as sensitive stress, mass and temperature sensors with high time resolution. The technique has some advantages with respect to video-microscope imaging and ultra-precision weighting with electronic microbalances or quartz crystal microbalances, since it allows to measure more drop parameters simultaneously for smaller drop sizes. On hydrophobic surfaces a single measurement with a silicon cantilever provides data for the drop mass, contact angle and radius until very close to complete evaporation. On hydrophilic surfaces, it is as well possible to measure drop mass and inclination of the cantilever. The technique further allows to detect differences between water microdrops evaporating from clean hydrophilic and hydrophobic surfaces. On hydrophilic surfaces the cantilever inclination is negative at the end of the evaporation process. Negative inclination mostly occurs when drops are pinned. This effect can not be detected with any of the other well-established methods. The evidence arises that on the hydrophilic surface a thin water film forms, while this is not the case for the hydrophobic surface. Metal coated cantilevers can be used as thermometers, and allow to precisely measure the temperature of an evaporating microdrop. This can be relevant for further applications of cantilevers as calorimetric sensors for chemical reactions taking place in drops on their surface. The applicability of Young’s equation was verified for microdrops. It was shown that Young’s equation can not be applied to microscopic drops due to their fast evaporation. A study on evaporation of microdrops in saturated vapor atmosphere was performed to estimate evaporation times and compare them with a theory developed, which relates the initial drop volume with the overall evaporation time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, new tools in atmospheric pollutant sampling and analysis were applied in order to go deeper in source apportionment study. The project was developed mainly by the study of atmospheric emission sources in a suburban area influenced by a municipal solid waste incinerator (MSWI), a medium-sized coastal tourist town and a motorway. Two main research lines were followed. For what concerns the first line, the potentiality of the use of PM samplers coupled with a wind select sensor was assessed. Results showed that they may be a valid support in source apportionment studies. However, meteorological and territorial conditions could strongly affect the results. Moreover, new markers were investigated, particularly focusing on the processes of biomass burning. OC revealed a good biomass combustion process indicator, as well as all determined organic compounds. Among metals, lead and aluminium are well related to the biomass combustion. Surprisingly PM was not enriched of potassium during bonfire event. The second research line consists on the application of Positive Matrix factorization (PMF), a new statistical tool in data analysis. This new technique was applied to datasets which refer to different time resolution data. PMF application to atmospheric deposition fluxes identified six main sources affecting the area. The incinerator’s relative contribution seemed to be negligible. PMF analysis was then applied to PM2.5 collected with samplers coupled with a wind select sensor. The higher number of determined environmental indicators allowed to obtain more detailed results on the sources affecting the area. Vehicular traffic revealed the source of greatest concern for the study area. Also in this case, incinerator’s relative contribution seemed to be negligible. Finally, the application of PMF analysis to hourly aerosol data demonstrated that the higher the temporal resolution of the data was, the more the source profiles were close to the real one.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mit der Erweiterung des Elektronenbeschleunigers MAMI um eine dritte Stufe ist es möglich geworden, am Institut für Kernphysik Teilchen mit offener Strangeness zu produzieren. Für deren Nachweis ist die Drei-Spektrometeranlage der Kollaboration A1 um das von der GSI in Darmstadt übernommene KAOS-Spektrometer erweitert worden. Untersucht wird damit die elementare Reaktion p(e,e' K+)Lambda/Sigma0 wobei das auslaufende Elektron und das Kaon nachgewiesen werden müssen. Wird als Target nicht Wasserstoff verwendet, besteht die Möglichkeit dass sich ein Hyperkern bildet. Spektroskopische Untersuchungen an diesen bieten die Möglichkeit das Potential von Hyperonen in Atomkernen und die Hyperon-Nukleon-Wechselwirkung zu untersuchen. Aufgrund der hervorragenden Strahlqualität bei der Elektroproduktion können hier Massenauflösungen von einigen hundert keV/c² erreicht werden. Mit Hilfe von GEANT4 wurden die Detektoren und die Abbildungseigenschaften des Spektrometers simuliert. Geeignete Ereignisgeneratoren wurden implementiert. Es wurde untersucht, wie mögliche Treffermuster in den Detektoren aussehen, die von einem Trigger auf FPGA-Basis selektiert werden müssen. Ebenso konnte hieraus eine erste Abbildung der Spurkoordinaten auf die Targetkoordinaten und den Teilchenimpuls gewonnen werden. Für das Hyperkernprogramm muss KAOS unter 0° Vorwärtsrichung betrieben werden und der Primärstrahl mit Hilfe einer Schikane durch den Dipol gelenkt werden. Die Simulation zeigt hier eine nur moderate Erhöhung der Strahlenbelastung, vor allem im Bereich des Strahlfängers. Somit ist es möglich, KAOS als doppelseitiges Spektrometer in der Spektrometerhalle zu betreiben. Im Rahmen dieser Arbeit wurden die für sämtliche Detektoren nötige Auslese- und Steuerungselektronik in das vorhandene Datenerfassungssystem und das Steuerungssystem eingebunden. In zwei Strahlzeiten im Herbst 2008 wurden Kaonen im Winkelbereich von 20°-40° mit Impulsen zwischen 400MeV/c und 600MeV/c nachgewiesen. Die aus der Simulation gewonnenen Daten zum Trigger und zur Abbildung kamen zum Einsatz. Es konnte die für eine gute Teilchenidentifikation nötige Zeitauflösung von ca. 1ns FWHM erreicht werden. Die erreichte Winkel- und Impulsauflösung war ausreichend um Lambda und Sigma0-Hyperonen im Spektrum der fehlenden Masse leicht trennen zu können.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mit der Zielsetzung der vorliegenden Arbeit wurde die detailierten Analyse von Migrationsdynamiken epithelilaler Monolayer anhand zweier neuartiger in vitro Biosensoren verfolgt, der elektrischen Zell-Substrat Impedanz Spektroskopie (electrical cell-substrate impedance sensing, ECIS) sowie der Quarz Kristall Mikrowaage (quartz crystal microbalance, QCM). Beide Methoden erwiesen sich als sensitiv gegenüber der Zellmotilität und der Nanozytotoxizität.rnInnerhalb des ersten Projektes wurde ein Fingerprinting von Krebszellen anhand ihrer Motilitätsdynamiken und der daraus generierten elektrischen oder akkustischen Fluktuationen auf ECIS oder QCM Basis vorgenommen; diese Echtzeitsensoren wurdene mit Hilfe klassicher in vitro Boyden-Kammer Migrations- und Invasions-assays validiert. Fluktuationssignaturen, also Langzeitkorrelationen oder fraktale Selbstähnlichkeit aufgrund der kollektiven Zellbewegung, wurden über Varianz-, Fourier- sowie trendbereinigende Fluktuationsanalyse quantifiziert. Stochastische Langzeitgedächtnisphänomene erwiesen sich als maßgebliche Beiträge zur Antwort adhärenter Zellen auf den QCM und ECIS-Sensoren. Des weiteren wurde der Einfluss niedermolekularer Toxine auf die Zytoslelettdynamiken verfolgt: die Auswirkungen von Cytochalasin D, Phalloidin und Blebbistatin sowie Taxol, Nocodazol und Colchicin wurden dabei über die QCM und ECIS Fluktuationsanalyse erfasst.rnIn einem zweiten Projektschwerpunkt wurden Adhäsionsprozesse sowie Zell-Zell und Zell-Substrat Degradationsprozesse bei Nanopartikelgabe charackterisiert, um ein Maß für Nanozytotoxizität in Abhangigkeit der Form, Funktionalisierung Stabilität oder Ladung der Partikel zu erhalten.rnAls Schlussfolgerung ist zu nennen, dass die neuartigen Echtzeit-Biosensoren QCM und ECIS eine hohe Zellspezifität besitzen, auf Zytoskelettdynamiken reagieren sowie als sensitive Detektoren für die Zellvitalität fungieren können.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Key technology applications like magnetoresistive sensors or the Magnetic Random Access Memory (MRAM) require reproducible magnetic switching mechanisms. i.e. predefined remanent states. At the same time advanced magnetic recording schemes push the magnetic switching time into the gyromagnetic regime. According to the Landau-Lifschitz-Gilbert formalism, relevant questions herein are associated with magnetic excitations (eigenmodes) and damping processes in confined magnetic thin film structures.rnObjects of study in this thesis are antiparallel pinned synthetic spin valves as they are extensively used as read heads in today’s magnetic storage devices. In such devices a ferromagnetic layer of high coercivity is stabilized via an exchange bias field by an antiferromagnet. A second hard magnetic layer, separated by a non-magnetic spacer of defined thickness, aligns antiparallel to the first. The orientation of the magnetization vector in the third ferromagnetic NiFe layer of low coercivity - the freelayer - is then sensed by the Giant MagnetoResistance (GMR) effect. This thesis reports results of element specific Time Resolved Photo-Emission Electron Microscopy (TR-PEEM) to image the magnetization dynamics of the free layer alone via X-ray Circular Dichroism (XMCD) at the Ni-L3 X-ray absorption edge.rnThe ferromagnetic systems, i.e. micron-sized spin valve stacks of typically deltaR/R = 15% and Permalloy single layers, were deposited onto the pulse leading centre stripe of coplanar wave guides, built in thin film wafer technology. The ferromagnetic platelets have been applied with varying geometry (rectangles, ellipses and squares), lateral dimension (in the range of several micrometers) and orientation to the magnetic field pulse to study the magnetization behaviour in dependence of these magnitudes. The observation of magnetic switching processes in the gigahertz range became only possible due to the joined effort of producing ultra-short X-ray pulses at the synchrotron source BESSY II (operated in the so-called low-alpha mode) and optimizing the wave guide design of the samples for high frequency electromagnetic excitation (FWHM typically several 100 ps). Space and time resolution of the experiment could be reduced to d = 100 nm and deltat = 15 ps, respectively.rnIn conclusion, it could be shown that the magnetization dynamics of the free layer of a synthetic GMR spin valve stack deviates significantly from a simple phase coherent rotation. In fact, the dynamic response of the free layer is a superposition of an averaged critically damped precessional motion and localized higher order spin wave modes. In a square platelet a standing spin wave with a period of 600 ps (1.7 GHz) was observed. At a first glance, the damping coefficient was found to be independent of the shape of the spin-valve element, thus favouring the model of homogeneous rotation and damping. Only by building the difference in the magnetic rotation between the central region and the outer rim of the platelet, the spin wave becomes visible. As they provide an additional efficient channel for energy dissipation, spin waves contribute to a higher effective damping coefficient (alpha = 0.01). Damping and magnetic switching behaviour in spin valves thus depend on the geometry of the element. Micromagnetic simulations reproduce the observed higher-order spin wave mode.rnBesides the short-run behaviour of the magnetization of spin valves Permalloy single layers with thicknesses ranging from 3 to 40 nm have been studied. The phase velocity of a spin wave in a 3 nm thick ellipse could be determined to 8.100 m/s. In a rectangular structure exhibiting a Landau-Lifschitz like domain pattern, the speed of the field pulse induced displacement of a 90°-Néel wall has been determined to 15.000 m/s.rn

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have realized a Data Acquisition chain for the use and characterization of APSEL4D, a 32 x 128 Monolithic Active Pixel Sensor, developed as a prototype for frontier experiments in high energy particle physics. In particular a transition board was realized for the conversion between the chip and the FPGA voltage levels and for the signal quality enhancing. A Xilinx Spartan-3 FPGA was used for real time data processing, for the chip control and the communication with a Personal Computer through a 2.0 USB port. For this purpose a firmware code, developed in VHDL language, was written. Finally a Graphical User Interface for the online system monitoring, hit display and chip control, based on windows and widgets, was realized developing a C++ code and using Qt and Qwt dedicated libraries. APSEL4D and the full acquisition chain were characterized for the first time with the electron beam of the transmission electron microscope and with 55Fe and 90Sr radioactive sources. In addition, a beam test was performed at the T9 station of the CERN PS, where hadrons of momentum of 12 GeV/c are available. The very high time resolution of APSEL4D (up to 2.5 Mfps, but used at 6 kfps) was fundamental in realizing a single electron Young experiment using nanometric double slits obtained by a FIB technique. On high statistical samples, it was possible to observe the interference and diffractions of single isolated electrons traveling inside a transmission electron microscope. For the first time, the information on the distribution of the arrival time of the single electrons has been extracted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Flüchtige organische Bestandteile (engl.: VOC) sind in der Atmosphäre in Spuren vorhanden, spielen aber trotzdem eine wichtige Rolle in der Luftchemie: sie beeinflussen das Ozon der Troposphäre, städtischen Smog, Oxidationskapazität und haben direkte und indirekte Auswirkungen auf die globale Klimaveränderung. Eine wichtige Klasse der VOC sind die Nicht-Methan-Kohlenwasserstoffe (engl.: NMHC), die überwiegend von anthropogenen Quellen kommen. Aus diesem Grund ist für Luftchemiker ein Messinstrument nötig, das die VOC, die NMHC eingeschlossen, mit einer höheren Zeitauflösung misst, besonders für Echtzeitmessungen an Bord eines Forschungsflugzeuges. Dafür wurde das System zur schnellen Beobachtung von organischen Spuren (engl.: FOTOS) entworfen, gebaut für den Einsatz in einem neuen Wissenschaftlichen Flugzeug, das in großen Höhen und über weite Strecken fliegt, genannt HALO. In der Folge wurde FOTOS in zwei Messkampagnen am Boden getestet. FOTOS wurde entworfen und gebaut mit einem speziell angefertigten, automatisierten, kryogenen Probensystem mit drei Fallen und einem angepassten, erworbenen schnellen GC-MS. Ziel dieses Aufbaus war es, die Vielseitigkeit zu vergrößern und das Störungspotential zu verringern, deshalb wurden keine chemischen Trocknungsmittel oder adsorbierenden Stoffe verwendet. FOTOS erreichte eine Probenfrequenz von 5.5 Minuten, während es mindestens 13 verschiedene C2- bis C5-NMHC maß. Die Drei-Sigma-Detektionsgrenze für n- und iso-Pentan wurde als 2.6 und 2.0 pptv ermittelt, in dieser Reihenfolge. Labortests bestätigten, dass FOTOS ein vielseitiges, robustes, hochautomatisiertes, präzises, genaues, empfindliches Instrument ist, geeignet für Echtzeitmessungen von VOC in Probenfrequenzen, die angemessen sind für ein Forschungsflugzeug wie HALO. Um die Leistung von FOTOS zu bestätigen, wurde vom 26. Januar bis 4. Februar 2010 ein Zwischenvergleich gemacht mit dem GC-FID-System am Meteorologischen Observatorium Hohenpeißenberg, einer WMO-GAW-globalen Station. Dreizehn verschiedene NMHC wurden innerhalb des Rahmens der GWA Data Quality Objectives (DQO) analysiert und verglichen. Mehr als 80% der Messungen von sechs C3- bis C5-NMHC erfüllten diese DQO. Diese erste Messkampagne im Feld hob die Robustheit und Messgenauigkeit von FOTOS hervor, zusätzlich zu dem Vorteil der höheren Probenfrequenz, sogar in einer Messung am Boden. Um die Möglichkeiten dieses Instrumentes im Feld zu zeigen, maß FOTOS ausgewählte leichte NMHC während einer Messkampagne im Borealen Waldgebiet, HUMPPA-COPEC 2010. Vom 12. Juli bis zum 12. August 2010 beteiligte sich eine internationale Gruppe von Instituten und Instrumenten an Messungen physikalischer und chemischer Größen der Gas- und Partikelphasen der Luft über dem Borealen Wald an der SMEAR II-Station nahe Hyyttiälä, Finnland. Es wurden mehrere Hauptpunkte von Interesse im Mischungsverhältnis der Alkane und im Isomerenverhätnis von Pentan identifiziert, insbesondere sehr unterschiedliche Perioden niedriger und hoher Variabilität, drei Rauchschwaden von Biomassen-Verbrennung von russischen Waldbränden und zwei Tage mit extrem sauberer Luft aus der Polarregion. Vergleiche der NMHC mit anderen anthropogenen Indikatoren zeigten mehrere Quellen anthropogener Einflüsse am Ort auf und erlaubten eine Unterscheidung zwischen lokalen und weiter entfernten Quellen. Auf einen minimalen natürlichen Beitrag zum 24h-Kreislauf von NOx wurde geschlussfolgert aus der Korrelation von NOx mit Alkanen. Altersschätzungen der Luftmassen durch das Isomerenverhältnis von Pentan wurden erschwert durch sich verändernde Verhältnisse der Quellen und durch Besonderheiten der Photochemie während des Sommers im hohen Norden. Diese Messungen zeigten den Wert des Messens leichter NMHC, selbst in abgelegenen Regionen, als einen zusätzlichen spezifischen Marker von anthropogenem Einfluss.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die Erzeugung von Elektronenstrahlen hoher Intensität (I$geq$2,mA) und hoher Spinpolarisation (P$geq$85%) ist für die Experimente an den geplanten glqq Linac Ringgrqq Electron--Ion--Collidern (z.B. eRHIC am Brookhaven National Laboratory) unabdingbar, stellt aber zugleich eine enorme Herausforderung dar. Die Photoemission aus ce{GaAs}--basierten Halbleitern wie z.B. den in dieser Arbeit untersuchten GaAlAs/InGaAlAs Quanten--Übergittern zeichnet sich zwar durch eine hohe Brillanz aus, die geringe Quantenausbeute von nur ca. 1% im Bereich maximaler Polarisation erfordert jedoch hohe Laserintensitäten von mehreren Watt pro $text{cm}^{2}$, was erhebliche thermische Probleme verursacht. rnrnIn dieser Arbeit konnte zunächst gezeigt werden, dass die Lebensdauer einer Photokathode mit steigender Laserleistung bzw. Temperatur exponentiell abnimmt. Durch Einbringen eines DBR--Spiegels zwischen die aktive Zone der Photokathode und ihr Substrat wird ein Großteil des ungenutzten Laserlichts wieder aus dem Kristall herausreflektiert und trägt somit nicht zur Erwärmung bei. Gleichzeitig bildet der Spiegel zusammen mit der Grenzfläche zum Vakuum eine Resonator--Struktur aus, die die aktive Zone umschließt. Dadurch kommt es für bestimmte Wellenlängen zu konstruktiver Interferenz und die Absorption in der aktiven Zone erhöht sich. Beide Effekte konnten durch vergleichenden Messungen an Kathoden mit und ohne DBR--Spiegel nachgewiesen werden. Dabei ergibt sich eine gute Übereinstimmung mit der Vorhersage eines Modells, das auf der dielektrischen Funktion der einzelnen Halbleiterstrukturen beruht. Von besonderer praktischer Bedeutung ist, dass die DBR--Kathode für einen gegebenen Photoemissions-strom eine um einen Faktor $geq$,3{,}5 kleinere Erwärmung aufweist. Dies gilt über den gesamten Wellenlängenbereich in dem die Kathode eine hohe Strahlpolarisation (P$>$80%) produzieren kann, auch im Bereich der Resonanz.rnAus zeitaufgelösten Messungen der Ladungsverteilung und Polarisation lassen sich sowohl Rückschlüsse über die Transportmechanismen im Inneren einer Kathode als auch über die Beschaffenheit ihrer Oberfläche ziehen. Im Rahmen dieser Dissertation konnte die Messgeschwindigkeit der verwendeten Apparatur durch den Einbau eines schnelleren Detektors und durch eine Automatisierung der Messprozedur entscheidend vergrößert und die resultierende Zeitauflösung mit jetzt 1{,}2 Pikosekunden annähernd verdoppelt werden.rnrnDie mit diesen Verbesserungen erhaltenen Ergebnisse zeigen, dass sich der Transport der Elektronen in Superlattice--Strukturen stark vom Transport in den bisher untersuchten Bulk--Kristallen unterscheidet. Der Charakter der Bewegung folgt nicht dem Diffusionsmodell, sondern gibt Hinweise auf lokalisierte Zustände, die nahe der Leitungsbandunterkante liegen und Elektronen für kurze Zeit einfangen können. Dadurch hat die Impulsantwort einer Kathode neben einem schnellen Abfall des Signals auch eine größere Zeitkonstante, die selbst nach 30,ps noch ein Signal in der Größenordnung von ca. 5textperthousand der Maximalintensität erzeugt.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plasmonic nanoparticles are great candidates for sensing applications with optical read-out. Plasmon sensing is based on the interaction of the nanoparticle with electromagnetic waves where the particle scatters light at its resonance wavelength. This wavelength depends on several intrinsic factors like material, shape and size of the nanoparticle as well as extrinsic factors like the refractive index of the surrounding medium. The latter allows the nanoparticle to be used as a sensor; changes in the proximate environment can be directly monitored by the wavelength of the emitted light. Due to their minuscule size and high sensitivity this allows individual nanoparticles to report on changes in particle coverage.rnrnTo use this single particle plasmon sensor for future sensing applications it has to meet the demand for detection of incidents on the single molecule level, such as single molecule sensing or even the detection of conformational changes of a single molecule. Therefore, time resolution and sensitivity have to be enhanced as today’s measurement methods for signal read-out are too slow and not sensitive enough to resolve these processes. This thesis presents a new experimental setup, the 'Plasmon Fluctuation Setup', that leads to tremendous improvements in time resolution and sensitivity. This is achieved by implementation of a stronger light source and a more sensitive detector. The new setup has a time resolution in the microsecond regime, an advancement of 4-6 orders of magnitude to previous setups. Its resonance wavelength stability of 0.03 nm, measured with an exposure time of 10 ms, is an improvement of a factor of 20 even though the exposure time is 3000 times shorter than in previous reports. Thus, previously unresolvable wavelength changes of the plasmon sensor induced by minor local environmental alteration can be monitored with extremely high temporal resolution.rnrnUsing the 'Plasmon Fluctuation Setup', I can resolve adsorption events of single unlabeled proteins on an individual nanorod. Additionally, I monitored the dynamic evolution of a single protein binding event on a millisecond time scale. This feasibility is of high interest as the role of certain domains in the protein can be probed by a study of modified analytes without the need for labels possibly introducing conformational or characteristic changes to the target. The technique also resolves equilibrium fluctuations in the coverage, opening a window into observing Brownian dynamics of unlabeled macromolecules. rnrnA further topic addressed in this thesis is the usability of the nanoruler, two nanospheres connected with a spacer molecule, as a stiffness sensor for the interparticle linker under strong illumination. Here, I discover a light induced collapse of the nanoruler. Furthermore, I exploit the sensing volume of a fixed nanorod to study unlabeled analytes diffusing around the nanorod at concentrations that are too high for fluorescence correlation spectroscopy but realistic for biological systems. Additionally, local pH sensing with nanoparticles is achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The upgrade of the Mainz Mikrotron (MAMI) electron accelerator facility in 2007 which raised the beam energy up to 1.5,GeV, gives the opportunity to study strangeness production channels through electromagnetic process. The Kaon Spectrometer (KAOS) managed by the A1 Collaboration, enables the efficient detection of the kaons associated with strangeness electroproduction. Used as a single arm spectrometer, it can be combined with the existing high-resolution spectrometers for exclusive measurements in the kinematic domain accessible to them.rnrnFor studying hypernuclear production in the ^A Z(e,e'K^+) _Lambda ^A(Z-1) reaction, the detection of electrons at very forward angles is needed. Therefore, the use of KAOS as a double-arm spectrometer for detection of kaons and the electrons at the same time is mandatory. Thus, the electron arm should be provided with a new detector package, with high counting rate capability and high granularity for a good spatial resolution. To this end, a new state-of-the-art scintillating fiber hodoscope has been developed as an electron detector.rnrnThe hodoscope is made of two planes with a total of 18432 scintillating double-clad fibers of 0.83 mm diameter. Each plane is formed by 72 modules. Each module is formed from a 60deg slanted multi-layer bundle, where 4 fibers of a tilted column are connected to a common read out. The read-out is made with 32 channels of linear array multianode photomultipliers. Signal processing makes use of newly developed double-threshold discriminators. The discriminated signal is sent in parallel to dead-time free time-to-digital modules and to logic modules for triggering purposes.rnrnTwo fiber modules were tested with a carbon beam at GSI, showing a time resolution of 220 ps (FWHM) and a position residual of 270 microm m (FWHM) with a detection efficiency epsilon>99%.rnrnThe characterization of the spectrometer arm has been achieved through simulations calculating the transfer matrix of track parameters from the fiber detector focal plane to the primary vertex. This transfer matrix has been calculated to first order using beam transport optics and has been checked by quasielastic scattering off a carbon target, where the full kinematics is determined by measuring the recoil proton momentum. The reconstruction accuracy for the emission parameters at the quasielastic vertex was found to be on the order of 0.3 % in first test realized.rnrnThe design, construction process, commissioning, testing and characterization of the fiber hodoscope are presented in this work which has been developed at the Institut für Kernphysik of the Johannes Gutenberg - Universität Mainz.