951 resultados para The Collector
Resumo:
This dissertation conducted in the years 2011 and 2012, an analysis of cooperatives waste pickers in the city of Natal, Rio Grande do Norte, aiming to identify improvements to be implemented to assist the management of waste from the municipality as well as to improve the living conditions of the workers who perform the selective collection, the environmental perspective. This analysis was performed by means of an investigation of the reality in which they live cooperatives and their local representation, using also the law. The research is characterized as a case study of an applied nature, documentary, consultations with the institutions related to the issue of solid waste in the national and local levels; exploratory and descriptive, the main methodological tools technical visits and structured interviews. From these methods was possible to obtain data regarding the organization of cooperatives, environmental perception of the collector of recyclable materials, among other issues. For the analysis of data matrices were used to include comments and method GUT, from which it was possible to identify numerous difficulties faced by recycling cooperatives, and develop proposals for possible improvements in various aspects of their operation, such as infrastructure and production process , which can improve both the waste management and the quality of life of workers involved in the selective collection system city
Resumo:
This thesis carries through an application of Analysis of Multicriterion Decision with use of the method of Analytical Hierarchy Process (AHP) in the problematic one of taking of decision of the adoption of electronic collecting in the system of urban transport in the country, a subject that has been controversial. A modeling of criteria and alternatives is carried through and applied a questionnaire based on method AHP the excellent actors in the system of urban transport - Leading of the Managing Agency Public Municipal theatre of Urban Transports, Controller of Company of Bus, Controller of Labor union, Controller of Union of Companies, Communitarian Leader. The considered alternatives were: the maintenance of the current state with collectors, the implementation of electronic collection without collectors, and the implementation of electronic collection with collectors. The used criteria were: job, impact in the fare, control of the system, easiness of use, information. The study was carried through in the city of Natal, RN, where if the adoption of electronic collection argues and where this implementation in some bus lines between Natal and Parnamirim exists, city that integrates the region of the great Natal. The main results of the method evidence in a dimension, the viability of use of method AHP with questionnaire by means of validation of the judgments with analysis of variance beyond proper the normal mechanisms of analysis of consistency to the method, and in another one, the contribution of the analysis boarding multicriterion to become the judgments more clearly. The main results of the analysis help to show that although to models of criteria and distinct judgments of the actors, the method evidenced that it has inclination the adoption of the electronic collection on the current situation, even so with divergences between the maintenance or not of the collector. The research points to the possibility of accomplishment of the application of the AHP in successive rounds of judgments
Resumo:
An solar alternative system for water heating is presented. Is composed for one low cost alternative collector and alternative thermal reservoir for hot water storing. The collector of the system has box confectioned in composite material and use absorption coils formed for PVC tubes. The box of hot water storage was confectioned from a plastic polyethylene drum used for storage of water and garbage, coated for a cylinder confectioned in fiber glass. The principle of functioning of the system is the same of the conventionally. Its regimen of work is the thermosiphon for a volume of 250 liters water. The main characteristic of the system in considered study is its low cost, allowing a bigger socialization of the use of solar energy. It will be demonstrated the viabilities thermal, economic and of materials of the system of considered heating, and its competitiveness in relation to the available collectors commercially. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be shown that such system of alternative heating, that has as main characteristic its low cost, presents viabilities thermal, economic and of materials
Resumo:
A solar alternative system for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets bottles, cans of beer and soft drinks and tubes of PVC, ½ " and the thermal reservoirs from a drum of polyethylene used for storage of water and garbage placed inside cylinder of fiber glass and EPS ground between the two surfaces. Such collectors are formed by three elements: pet bottles, cans and tubes absorbers. The heating units, which form the collector contains inside the cans that can be closed, in original form or in the form of plate. The collectors have an absorber grid formed by eight absorbers PVC tube, connected through connections at T of the same material and diameter. It will be presented data of the thermal parameters which demonstrate the efficiency of the heating system proposed. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be demonstrated that this alternative heating system, which has as its main feature low cost, presents thermal, economic and materials viabilities
Resumo:
It s presented a solar collector to be used in a system for heating bath water, whose main characteristic is its low cost. The collector consists of five plates of PVC with 10 mm thick, 200 mm in width and 1400mm in length, with an area equal to 1.4 square meters. The plates were connected in parallel to the ends of PVC tubes of 40 mm and 32 mm. The plates were coated on one side with aluminum sheets of soft drinks and beers cans open. The system worked on a thermosiphon and was tested in two configurations: the plates uncoated and coated with aluminum material, to determine the influence of material on the efficiency of the collector. For both configurations was used EPS plates below the surface to minimize heat losses from the botton. The thermal reservoir of the heating system is, also, alternative and low cost, since it was constructed from a polyethylene tank for storing water, with volume of 150 end 200 liters. It will be presented the thermal efficiency, heat loss, water temperature of the thermal reservoir at the end of the process and simulation of baths for a house with four residents. The will be demonstrated thermal, economic and material viability of the proposed collector, whose main innovation is the use of recyclables materials, cans of beer and soft drinks, to increase the temperature of the absorber plate.
Resumo:
It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are its low cost and easy manufacturing and assembly. The absorbing surface of the collector is formed by an aluminum plate with eight flaps where they lodge PVC pipes. The catchment area of solar radiation corresponds to 1.3 meters. The collector box was made of wood, is covered by transparent glass and thermal insulation of tire chips and expanded polystyrene (EPS). Absorber tubes were connected in parallel through the use of PVC fittings and fixed to the plate by the use of metal poles and rivets. The entire absorber received paint flat black for better absorption of sunlight. The system worked on a thermosiphon assembly and absorber of the collector has been tested in two configurations: with the tubes facing up, directly exposed to the impact of sunlight and facing down, exchanging heat with the plate by conduction. It was determined the most efficient configuration for the correct purpose. The solar collector was connected to a thermal reservoir, also alternative, low-cost forming the system of solar water heating. We evaluated thermal parameters that proved the viability of the heating system studied
Resumo:
It presents a solar collector to be used in a system for heating water for bathing, whose main characteristics are low cost and easy manufacturing and assembly. The system operates under natural convection or thermosiphon. The absorbing surface of the collector is formed by twelve PVC pipes of 25 mm outside diameter connected in parallel via connections in T of the same material. The tubes were covered with absorbing fins made with recycled aluminum cans. We studied eight settings between absorber plate, thermal insulating EPS boards and thermal reservoirs 150 and 200 liters. It was determined the most efficient configuration for the correct purpose. We evaluated thermal parameters that proved the viability of the heating system studied
Resumo:
We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.
Resumo:
It was studied a system for heating water to be used to obtain water for bathing at home, the absorbing surface of the collector is formed by one plate of polycarbonate. The polycarbonate plate has 6 mm thick, 1.050 mm wide and 1.500 mm long with an area equal to 1,575 m². The plate was attached by its edges parallel to PVC tubes of 32 mm. The system worked under the thermo-siphon and was tested for two configurations: plate absorber with and without isolation of EPS of 30 mm thick on the bottom surface in order to minimize heat losses from the bottom. The tank's thermal heating system is alternative and low cost, since it was constructed from a polyethylene reservoir for water storage, with a volume of 200 liters. Will present data on the thermal efficiency, heat loss, water temperature of thermal reservoir at the end of the process simulation and baths. Will be demonstrated the feasibility of thermal, economic and material pickup proposed for the intended purpose.
Resumo:
The reality points to the global environmental sustainability as the only viable option for addressing the crisis at hand. The move towards sustainability calls for the generation / evaluation systems in their direction, through the incorporation of environmental requirements and in line with the National Policy on Solid Waste. Therefore, the proposed research supports the importance of social and environmental vision, complementing the technical view, the system for management of solid waste from East London, which is a municipality that has a system whose inadequacies are configured in environmental risk and health. Therefore, by observing, applying the model of sustainability indicators and content analysis of interviews, this research proposes to investigate the principles of sustainability and social participation are presented and what is the perception of risk about the inadequacies in the system. The results confirmed the hypotheses of the study and draw a picture of worrying data, such as very unfavorable indicators of sustainability, lack of channels of participation, uncommitted investments with the management system, devaluation of the collector of waste and differing perceptions about the risk by making actors act in isolation. This worrying situation is eased by the appearance of a series of elements are configured as opportunities for the integration of environmental principles in the system. And despite the inability of managers to participate in the research system, yet it behaves as an opportunity to implement public policies in the area of solid waste such as: the preparation of the municipal waste, the institutionalization of selective collection and organization of cooperative with the support of companies present in the city and educational institutions as the Federal Institute. The research is an opportunity for the implementation of policies in the area of solid waste and will collaborate with the building instruments for the quality of life of residents, for the socioeconomic conditions of collectors and the move towards a sustainable society
Resumo:
This study was conducted in an area of restinga in the municipality of Silo Vicente (SP). The study aimed to evaluate the seed rain in three different conditions of regeneration. Was selected the following conditions: High Forest of Restinga in the middle stage of regeneration, an area of clearing in the same condition mentioned above and a third in early stages of regeneration. hi each condition were installed 10 seed collectors made of wood and screen with 80% of shade, supported to a height of 20cm of soil. They were evaluated monthly for one yew; the densities of seed deposited in the collector these seedlings are identified and categorized based on their dispersion syndrome and successional classes. The Area of High Forest area was carried out a phytosociological survey to identify which seedlings present in the rain could be from these areas. It was found that the densities of seedlings are relatively low compared to other formations of the Atlantic rain forest, but consistent with other studies of the same type of vegetation used in the study. Regarding dispersal syndromes and successional classes, there was prevalence of the zoocoric syndrome and species of secondary successional classes. The results indicate that the area has good ability to maintain their succession dynamics.
Bioaccumulation of metals in aquatic insects of streams located in areas with sugar cane cultivation
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The main pool of dissolved organic carbon in tropical aquatic environments, notably in dark-coloured streams, is concentrated in humic substances (HS). Aquatic HS are large organic molecules formed by micro-biotic degradation of biopolymers and polymerization of smaller organic molecules. From an environmental point of view, the study of metal-humic interactions is often aimed at predicting the effect of aquatic HS on the bioavailability of heavy metal ions in the environment. In the present work the aquatic humic substances (HS) isolated from a dark-brown stream (located in an environmental protection area near Cubatao city in São Paulo-State, Brazil) by means of the collector XAD-8 were investigated. FTIR studies showed that the carboxylic carbons are probably the most important binding sites for Hg(II) ions within humic molecules. C-13-NMR and H-1-NMR studies of aquatic HS showed the presence of constituents with a high degree of aromaticity (40% of carbons) and small substitution. A special five-stage tangential-flow ultrafiltration device (UF) was used for size fractionation of the aquatic HS under study and for their metal species in the molecular size range 1-100 kDa (six fractions). The fractionation patterns showed that metal traces remaining in aquatic HS after their XAD-8 isolation have different distributions. Generally, the major percentage of traces of Mn, Cd and Ni (determined by ICP-AES) was preferably complexed by molecules with relatively high molecular size. Cu was bound by fractions with low molecular size and Co showed no preferential binding site in the various humic fractions. Moreover, the species formed between aquatic HS and Hg(II), prepared by spiking (determined by CVAAS), appeared to be concentrated in the relatively high molecular size fraction F-1 (> 100 kDa).
Resumo:
The influence of structural features of tropical river humic substances (HS) on their capability to reduce mercury(II) in aqueous solutions was studied. The HS investigated were conventionally isolated from Rio Negro water-Amazonas State/Brazil by means of the collector XAD 8. In addition, the isolated HS were on-line fractionated by tangential-flow multistage ultrafiltration (nominal molecular-weight cut-offs: 100, 50, 30, 10, 5 kDa) and characterized by potentiometry and UV/VIS spectroscopy. The reduction of Hg(II) ions to elemental Hg by size-fractions of Rio Negro HS was assessed by cold-vapor AAS (CVAAS). UV/VIS spectrometry revealed that the fractions of high molecular-size (F-1 > 100 kDa and F-2: 50-100 kDa) have a higher aromaticity compared to the fractions of small molecular-size (F-5: 5-10 kDa, F-6: < 5 kDa). In contrast, the potentiometric study showed different concentration of functional groups in the studied HS fractions. The reduction of Hg(II) by aquatic HS fractions at pH 5 proceeded in two steps (I, II) of slow first order kinetics (t(1/2) of I: 160 min, t(1/2) of II: 300 min) weakly influenced by the molecular-size, in contrast to the differing degree of Hg(II) reduction (F-5 > F-2 > > F-1 > F-3 > F-4 > > F-6). Accordingly, Hg(II) ions were preferably reduced by HS molecules having a relatively high ratio of phenolic/carboxylic groups and a small concentration of sulfur. From these results a complex 'competition' between reduction and complexation of mercury(II) by aquatic HS occurring in tropical rivers such as the Rio Negro can be suggested. (C) 2003 Elsevier B.V. All rights reserved.