987 resultados para Telecom wavelengths


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the effects of monochromatic light on the specific growth rate (SGR), feed intake and feed efficiency (FE) of juvenile pikeperch, Sander lucioperca (L.). Pikeperch were reared individually for 42 days in aquaria covered with blue, green, yellow or red gelatin filters or white paper (control; n=5). Linear regression analysis indicated a significant positive effect of longer wavelengths of light on the condition factor (CF), FE and SGR. The final weight, SGR and CF were significantly higher in fish reared under red than under white light, and FE was better under green, yellow and red light than under white light (Dunnett's post hoc test, P < 0.05) while blue was comparable to white light in terms of the measured parameters. After the growth trial, the spectral sensitivity of photoreceptor cells in the retina was tested using microspectrophotometry, which revealed the presence of rods with lambda(max) at ca. 530 nm and two cone classes, absorbing maximally at ca. 535 and 603 nm, all containing a porphyropsin-based pigment. These results suggest that the presence of mid and long wavelength-sensitive cones enhances visual sensitivity under mid-wavelength and long-wavelength environments, and thus supports the finding that longer wavelengths of incoming light can improve FE and SGR of the cultivated pikeperch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the effect of photochemical activation of hydrogen peroxide (H2O2) bleaching gel with different wavelengths. Methods: In the study, 80 bovine incisors were used, which were stained in 25% soluble coffee and divided in 4 groups. The initial color was measured with the Easy Shade spectrophotometer by CIE Lab. An experimental 35% H2O2 bleaching gel was used, either with or without the presence of titanium dioxide (TiO2) pigment, associated with two light sources: G1 - Transparent Gel (TG) and no activation; G2 - Gel with TiO2 and activation with blue LED (l=470nm)\laser (Easy Bleach) appliance; G3 - Gel with TiO2 and activation with ultraviolet (l=345nm - UV); G4 - TG and activation with UV. Three applications of the gels were made for 10 min, and in each, 3 activations of 3 min, with interval of 30 s between them. The coloration was evaluated again and the variation in color perception (DE) was calculated. The data were submitted to one-way ANOVA and Tukey's test at 5% significance level. Results: There were significant differences between G1 and G4. The greatest E value was observed in G4 (13.37). There was no statistically significant difference (p>0.05) between the groups 2, 3 and 4. Conclusions: The presence of TiO2 particules in the bleaching gel did not interfere at the bleaching results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have prepared heavy metal oxide glasses containing metallic copper nanoparticles with promising nonlinear optical properties which were determined by Z-scan and pump-probe measurements using femtosecond laser pulses. For the wavelengths within the plasmon band, we have observed saturable absorption and response times of 2.3 ps. For the other regions of the spectrum, reverse saturable absorption and lifetimes shorter than 200 fs were verified. The nonlinear refractive index is about 2.0 × 10-19 m2/W from visible to telecom region, thus presenting an enhancement effect at wavelengths near the plasmon and Cu+2 d-d band. © 2013 Springer Science+Business Media New York.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical networks based on passive-star couplers and employing WDM have been proposed for deployment in local and metropolitan areas. These networks suffer from splitting, coupling, and attenuation losses. Since there is an upper bound on transmitter power and a lower bound on receiver sensitivity, optical amplifiers are usually required to compensate for the power losses mentioned above. Due to the high cost of amplifiers, it is desirable to minimize their total number in the network. However, an optical amplifier has constraints on the maximum gain and the maximum output power it can supply; thus, optical amplifier placement becomes a challenging problem. In fact, the general problem of minimizing the total amplifier count is a mixed-integer nonlinear problem. Previous studies have attacked the amplifier-placement problem by adding the “artificial” constraint that all wavelengths, which are present at a particular point in a fiber, be at the same power level. This constraint simplifies the problem into a solvable mixed integer linear program. Unfortunately, this artificial constraint can miss feasible solutions that have a lower amplifier count but do not have the equally powered wavelengths constraint. In this paper, we present a method to solve the minimum amplifier- placement problem, while avoiding the equally powered wavelength constraint. We demonstrate that, by allowing signals to operate at different power levels, our method can reduce the number of amplifiers required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Nd:YLF/KGW Raman laser has been investigated in this work. We have demonstrated CW output powers at six different wavelengths, 1147 nm (0.70 W), 1163 nm (0.95 W), 549 nm (0.65 W), 552 nm (1.90 W), 573 nm (0.60 W) and 581 nm (1.10 W), with higher peak powers achieved under quasi-CW operation. Raman conversion of the 1053 nm fundamental emission is reported for the first time, enabling two new wavelengths in crystalline Raman lasers, 549 nm and 552 nm. The weak thermal lensing associated with Nd:YLF has enabled to achieve good beam quality, M-2 <= 2.0, and stable operation in relatively long cavities. (C) 2012 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aims to analyze the IT architecture management practices associated with their degree of maturity and the influence of institutional and strategic factors on the decisions involved through a case study in a large telecom organization. The case study allowed us to identify practices that led the company to its current stage of maturity and identify practices that can lead the company to the next stage. The strategic influence was mentioned by most respondents and the institutional influence was present in decisions related to innovation and those dealing with a higher level of uncertainties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Questo lavoro di tesi muove da tematiche relative alla sicurezza IT e risulta dagli otto mesi di lavoro all’interno della funzione Technical Security di Telecom Italia Information Technology. Il compito primario di questa unità di business è ridurre il rischio informatico dei sistemi di Telecom Italia per mezzo dell’attuazione del processo di ICT Risk Management, che coinvolge l’intera organizzazione ed è stato oggetto di una riprogettazione nel corso del 2012. Per estendere tale processo a tutti i sistemi informatici, nello specifico a quelli caratterizzati da non conformità, all’inizio del 2013 è stato avviato il Programma Strutturato di Sicurezza, un aggregato di quattro progetti dalla durata triennale particolarmente articolato e complesso. La pianificazione di tale Programma ha visto coinvolto, tra gli altri, il team di cui ho fatto parte, che ha collaborato con Telecom Italia assolvendo alcune delle funzioni di supporto tipiche dei Project Management Office (PMO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In modern implant dentistry there are several clinical indications for laser surgery. Different laser systems have a considerable spectrum of application in soft and hard peri-implant tissues. The literature was searched for clinical application of different laser wavelengths in peri-implant tissues: second-stage surgery of submerged implants, treatment of infrabony defects, removal of peri-implant hyperplastic overgrowths, and, possibly, the preparation of bone cavities for implant placement. This report describes the state-of-the-art application of different laser systems in modern implant dentistry for the treatment of peri-implant lesions and decontamination of implant surfaces. Our study evaluated in vitro examinations, clinical experience and long-term clinical studies. The exact selection of the appropriate laser system and wavelength was dependent on the scientific evaluation of recent literature and the level of changes in implant and tissue temperatures during laser application. The significant reduction in bacteria on the implant surface and the peri-implant tissues during irradiation and the cutting effects associated with the coagulation properties of the lasers are the main reasons for laser application in the treatment of peri-implant lesions and the successful long-term prognosis of failing oral implants. The various applications of lasers in implant dentistry are dependent on the wavelength and laser-tissue interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a secondary eclipse observation for the hot Jupiter HD 189733b across the wavelength range 290-570 nm made using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. We measure geometric albedos of Ag = 0.40 ± 0.12 across 290-450 nm and Ag < 0.12 across 450-570 nm at 1σ confidence. The albedo decrease toward longer wavelengths is also apparent when using six wavelength bins over the same wavelength range. This can be interpreted as evidence for optically thick reflective clouds on the dayside hemisphere with sodium absorption suppressing the scattered light signal beyond ~450 nm. Our best-fit albedo values imply that HD 189733b would appear a deep blue color at visible wavelengths.

Relevância:

20.00% 20.00%

Publicador: