986 resultados para T1-TOPOLOGIES
Resumo:
In a retrospective analysis with two readers blinded to the clinical information, coronal short tau inversion recovery (STIR) images were compared to contrast-enhanced fat-saturated T1-weighted imaging (T1 CEfs) in 51 cases of cervical lymphoma. Interrater reliability was good to excellent. Although sensitivity and subjective quality of the STIR sequence were higher than those of the T1 CEfs sequence (sensitivity 85%/72%, respectively), specificity (82%/95%) as well as positive likelihood ratio (4.65/15.93) was much lower. Therefore, contrast-enhanced sequences should be included in the primary staging of lymphoma.
Resumo:
OBJECTIVE: The benefit of postoperative radiation for advanced primary parotid carcinoma has been reported previously, whereas studies to evaluate the usefulness of postoperative radiation for T1 and T2 parotid carcinomas have never been performed. STUDY DESIGN AND SETTING: Retrospective analysis on 58 previously untreated patients with T1 and T2 parotid carcinomas. In 34 patients, postoperative radiation was included in the treatment protocol and in 24 patients, no postoperative radiation was applied. RESULTS: A local recurrence was observed in 8 of 24 (33%) patients without and in 1 of 34 (3%) patients with postoperative radiation (P < 0.5). The 5-year actuarial and disease-free survival rate was 83% and 70% for patients without postoperative radiation and 93% and 92% for patients with postoperative radiation. CONCLUSION AND SIGNIFICANCE: Local recurrence was less often observed in patients with postoperative radiation. Nevertheless, prospective randomized studies are needed to confirm the usefulness of postoperative radiation in early carcinomas. EBM rating: B-3b.
Resumo:
PURPOSE: The aim of this study was to investigate the effect of magnetization transfer on multislice T(1) and T(2) measurements of articular cartilage. MATERIALS AND METHODS: A set of phantoms with different concentrations of collagen and contrast agent (Gd-DTPA(2-)) were used for the in vitro study. A total of 20 healthy knees were used for the in vivo study. T(1) and T(2) measurements were performed using fast-spin-echo inversion-recovery (FSE-IR) sequence and multi-spin-echo (MSE) sequence, respectively, in both in vitro and in vivo studies. We investigated the difference in T(1) and T(2) values between that measured by single-slice acquisition and that measured by multislice acquisition. RESULTS: Regarding T(1) measurement, a large drop of T(1) in all slices and also a large interslice variation in T(1) were observed when multislice acquisition was used. Regarding T(2) measurement, a substantial drop of T(2) in all slices was observed; however, there was no apparent interslice variation when multislice acquisition was used. CONCLUSION: This study demonstrated that the adaptation of multislice acquisition technique for T(1) measurement using FSE-IR methodology is difficult and its use for clinical evaluation is problematic. In contrast, multislice acquisition for T(2) measurement using MSE was clinically applicable if inaccuracies caused by multislice acquisition were taken into account. J. Magn. Reson. Imaging 2007;26:109-117. (c) 2007 Wiley-Liss, Inc.
Resumo:
The delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC) technique has shown promising results in pilot clinical studies of early osteoarthritis. Currently, its broader acceptance is limited by the long scan time and the need for postprocessing to calculate the T1 maps. A fast T1 mapping imaging technique based on two spoiled gradient echo images was implemented. In phantom studies, an appropriate flip angle combination optimized for center T1 of 756 to 955 ms yielded excellent agreement with T1 measured using the inversion recovery technique in the range of 200 to 900 ms, of interest in normal and diseased cartilage. In vivo validation was performed by serially imaging 26 hips using the inversion recovery and the Fast 2 angle T1 mapping techniques (center T1 756 ms). Excellent correlation with Pearson correlation coefficient R2 of 0.74 was seen and Bland-Altman plots demonstrated no systematic bias.
Resumo:
PURPOSE: To determine the feasibility of using a high resolution isotropic three-dimensional (3D) fast T1 mapping sequence for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) to assess osteoarthritis in the hip. MATERIALS AND METHODS: T1 maps of the hip were acquired using both low and high resolution techniques following the administration of 0.2 mmol/kg Gd-DTPA(2-) in 35 patients. Both T1 maps were generated from two separate spoiled GRE images. The high resolution T1 map was reconstructed in the anatomically equivalent plane as the low resolution map. T1 values from the equivalent anatomic regions containing femoral and acetabular cartilages were measured on the low and high resolution maps and compared using regression analysis. RESULTS: In vivo T1 measurements showed a statistically significant correlation between the low and high resolution acquisitions at 1.5 Tesla (R(2) = 0.958, P < 0.001). These results demonstrate the feasibility of using a fast two-angle T1 mapping (F2T1) sequence with isotropic spatial resolution (0.8 x 0.8 x 0.8 mm) for quantitative assessment of biochemical status in articular cartilage of the hip. CONCLUSION: The high resolution 3D F2T1 sequence provides accurate T1 measurements in femoral and acetabular cartilages of the hip, which enables the biochemical assessment of articular cartilage in any plane through the joint. It is a powerful tool for researchers and clinicians to acquire high resolution data in a reasonable scan time (< 30 min).
Resumo:
OBJECTIVES: To evaluate the relationship between T1 after intravenous contrast administration (T1Gd) and Delta relaxation rate (DeltaR1) = (1/T1(Gd) - 1/T1o) in the delayed Gadolinium-Enhanced MRI of cartilage (dGEMRIC) evaluation of cartilage repair tissue. MATERIALS AND METHODS: Thirty single MR examinations from 30 patients after matrix-associated autologous chondrocyte transplantations of the knee joint with different postoperative intervals were examined using an 8-channel knee-coil at 3T. T1 mapping using a 3D GRE sequence with a 35/10 degrees flip angle excitation pulse combination was performed before and after contrast administration (dGEMRIC technique). T1 postcontrast (T1(Gd)) and the DeltaR1 (relative index of pre- and postcontrast R1 value) were calculated for repair tissue and the weight-bearing normal appearing control cartilage. For evaluation of the different postoperative intervals, MR exams were subdivided into 3 groups (up to 12 months, 12-24 months, more than 24 months). For statistical analysis Spearman correlation coefficients were calculated. RESULTS: The mean value for T1 postcontrast was 427 +/- 159 ms, for DeltaR1 1.85 +/- 1.0; in reference cartilage 636 +/- 181 ms for T1 postcontrast and 0.83 +/- 0.5 for DeltaR1.The correlation coefficients were highly significant between T1 (Gd) and DeltaR1 for repair tissue (0.969) as well as normal reference cartilage (0.928) in total, and for the reparative cartilage in the early, middle postoperative, and late postoperative interval after surgery (R values: -0.986, -0.970, and -0.978, respectively). Using either T1(Gd) or DeltaR1, the 2 metrics resulted in similar conclusions regarding the time course of change of repair tissue and control tissue, namely that highly significant (P > 0.01) differences between cartilage repair tissue and reference cartilage were found for all follow-up groups. Additionally, for both metrics highly significant differences (P < 0.01) between early follow up and the 2 later postoperative groups for cartilage repair tissue were found. No statistical differences were found between the 2 later follow-up groups of reparative cartilage either for T1 (Gd) or DeltaR1. CONCLUSION: The high correlation between T1 (Gd) and DeltaR1 and the comparable conclusions reached utilizing metric implies that T1 mapping before intravenous administration of MR contrast agent is not necessary for the evaluation of repair tissue. This will help to reduce costs, inconvenience for the patients, simplifies the examination procedure, and makes dGEMRIC more attractive for follow-up of patients after cartilage repair surgeries.
Resumo:
Quantitative meta-analyses of randomized clinical trials investigating the specific therapeutic efficacy of homeopathic remedies yielded statistically significant differences compared to placebo. Since the remedies used contained mostly only very low concentrations of pharmacologically active compounds, these effects cannot be accounted for within the framework of current pharmacology. Theories to explain clinical effects of homeopathic remedies are partially based upon changes in diluent structure. To investigate the latter, we measured for the first time high-field (600/500 MHz) 1H T1 and T2 nuclear magnetic resonance relaxation times of H2O in homeopathic preparations with concurrent contamination control by inductively coupled plasma mass spectrometry (ICP-MS). Homeopathic preparations of quartz (10c–30c, n = 21, corresponding to iterative dilutions of 100−10–100−30), sulfur (13x–30x, n = 18, 10−13–10−30), and copper sulfate (11c–30c, n = 20, 100−11–100−30) were compared to n = 10 independent controls each (analogously agitated dilution medium) in randomized and blinded experiments. In none of the samples, the concentration of any element analyzed by ICP-MS exceeded 10 ppb. In the first measurement series (600 MHz), there was a significant increase in T1 for all samples as a function of time, and there were no significant differences between homeopathic potencies and controls. In the second measurement series (500 MHz) 1 year after preparation, we observed statistically significant increased T1 relaxation times for homeopathic sulfur preparations compared to controls. Fifteen out of 18 correlations between sample triplicates were higher for controls than for homeopathic preparations. No conclusive explanation for these phenomena can be given at present. Possible hypotheses involve differential leaching from the measurement vessel walls or a change in water molecule dynamics, i.e., in rotational correlation time and/or diffusion. Homeopathic preparations thus may exhibit specific physicochemical properties that need to be determined in detail in future investigations.
Resumo:
Mobile multimedia ad hoc services run on dynamic topologies due to node mobility or failures and wireless channel impairments. A robust routing service must adapt to topology changes with the aim of recovering or maintaining the video quality level and reducing the impact of the user's experience. In those scenarios, beacon-less Opportunistic Routing (OR) increases the robustness by supporting routing decisions in a completely distributed manner based on protocol-specific characteristics. However, the existing beacon-less OR approaches do not efficiently combine multiple metrics for forwarding selection, which cause higher packet loss rate, and consequently reduce the video quality level. In this paper, we assess the robustness and reliability of our recently developed OR protocol under node failures, called cross-layer Link quality and Geographical-aware OR protocol (LinGO). Simulation results show that LinGO achieves multimedia dissemination with QoE support and robustness in scenarios with dynamic topologies.
Resumo:
Hips with a cam deformity are at risk for early cartilage degeneration, mainly in the anterolateral region of the joint. T1ρ MRI is a described technique for assessment of proteoglycan content in hyaline cartilage and subsequently early cartilage damage. In this study, 1.5 Tesla T1ρ MRI was performed on 20 asymptomatic hips with a cam deformity and compared to 16 healthy control hips. Cam deformity was defined as an alpha angle at 1:30 o'clock position over 60° and/or at 3:00 o'clock position over 50.5°. Hip cartilage was segmented and divided into four regions of interest (ROIs): anterolateral, anteromedial, posterolateral and posteromedial quadrants. Mean T1ρ value of the entire weight bearing cartilage in hips with a cam deformity (34.0 ± 4.6 ms) was significantly higher compared to control hips (31.3 ± 3.2 ms, p = 0.050). This difference reached significance in the anterolateral (p = 0.042) and posteromedial quadrants (p = 0.041). No significant correlation between the alpha angle and T1ρ values was detected. The results indicate cartilage damage occurs in hips with a cam deformity before symptoms occur. A significant difference in T1ρ values was found in the anterolateral quadrant, the area of direct engagement of the deformity, and in the posteromedial quadrant. To conclude, T1ρ MRI can detect early chondral damage in asymptomatic hips with a cam deformity. This article is protected by copyright. All rights reserved.
Resumo:
Tochilinite (approximately FeS(Mg,Fe)(OH)2) is locally abundant in Hole 1068A serpentinites from Cores 173-1068A-21R and 22R. It occurs in veins, as fillings in void space, and in intergrowths with serpentine and andradite. An apparently related mineral, but with Ca and Al largely replacing Mg, occurs in association with, and possibly as a replacement of, pyrrhotite in serpentinite breccias from the bottom of Core 173-1068A-20R. The transition from Mg-Fe-rich brucite tochilinites to Ca- and S-rich carbonate tochilinites is consistent with increasing sulfur and oxygen activity upsection. Tochilinite has been reported at other sites on the Iberia Abyssal Plain and is abundant to the point of being a rock-forming mineral in several samples from Site 1068. Rather than being a mineralogical curiosity, tochilinite appears to be common and a major sink for sulfur in the upper serpentinites of the Iberia Abyssal Plain.
Resumo:
A primary objective of Leg 175 was to investigate the upwelling history of the Benguela Current. Upwelling along the coast is found over the shelf in several well-established cells, as well as along the shelf-slope break, and extends over the 1000-m isobath. Streaming filaments along the coast also carry upwelled water off shore (Shannon, 1985). The upwelled nutrient-rich waters are sourced from the South Atlantic central water mass, which is a mixture of subtropical and subantarctic water masses. Below the central water mass lies Antarctic intermediate water (Shannon and Hunter, 1988, doi:10.2989/025776188784480735; Stramma and Peterson, 1989, doi:10.1175/1520-0485(1989)019<1440:GTITBC>2.0.CO;2). The upwelling system supports a robust marine community (Shannon and Pillar, 1986) where radiolarians are abundant (Bishop et al., 1978, doi:10.1016/0146-6291(78)90010-3). The endemic nature of radiolarians makes them useful in reconstructing the paleocirculation patterns. The biogeographic distribution of many species is limited by water-mass distribution. In a given geographic region, species may also have discrete depth habitats. However, their depth of occurrence can change worldwide because the depths of water masses vary with latitude (Boltovskoy, 1999). Consequently, species found at shallow depths at high latitudes (cold-water fauna) are observed deeper in the water column at lower latitudes. The low-latitude submergence of cold-water species broadens their distribution, resulting in species distributions that can cover multiple geographic regions (Kling, 1976, doi:10.1016/0011-7471(76)90880-9; Casey, doi:10.1016/0031-0182(89)90017-5; 1971; Boltovskoy, 1987, doi:10.1016/0377-8398(87)90014-4). Since radiolarian distribution is closely related to water-mass distribution and controlled by climatic conditions rather than geographic regions, similar assemblages characterize the equatorial, subtropical, transition, subpolar, and polar regions of ocean basins (Petrushevskaya, 1971a; Casey, 1989, doi:10.1016/0031-0182(89)90017-5; Boltovskoy, 1999). Numerous radiolarian species found in water masses in the Angola and Benguela Current systems have also been observed in plankton net samples, sediment traps, and surface-sediment studies in the Atlantic sector of the Southern Ocean, where they exhibited particular water-mass affinities (Abelmann, 1992a, doi:10.1007/BF00243107; Abelmann 1992b, doi:10.1007/BF00243108; Abelmann and Gowing, 1997, doi:10.1016/S0377-8398(96)00021-7). This report presents data on the radiolarian fauna recovered from Site 1082 sediments in the form of a survey of species reflecting the latitudinal migration of the Angola-Benguela Front and upwelling. The data constitute a time series of relative radiolarian abundances at very high resolution (every 20 cm) of the upper 12 m of Hole 1082A.