993 resultados para Systematic errors


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Decision makers often use ‘rules of thumb’, or heuristics, to help them handling decision situations (Kahneman and Tversky, 1979b). Those cognitive shortcuts are taken by the brain to cope with complexity and time limitation of decisions, by reducing the burden of information processing (Hodgkinson et al, 1999; Newell and Simon, 1972). Although crucial for decision-making, heuristics come at the cost of occasionally sending us off course, that is, make us fall into judgment traps (Tversky and Kahneman, 1974). Over fifty years of psychological research has shown that heuristics can lead to systematic errors, or biases, in decision-making. This study focuses on two particularly impactful biases to decision-making – the overconfidence and confirmation biases. A specific group – top management school students and recent graduates - were subject to classic experiments to measure their level of susceptibility to those biases. This population is bound to take decision positions at companies, and eventually make decisions that will impact not only their companies but society at large. The results show that this population is strongly biased by overconfidence, but less so to the confirmation bias. No significant relationship between the level of susceptibility to the overconfidence and to the confirmation bias was found.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this research is to discuss about the need for implementation of new alternatives for the implementation on the metrological control: on the findings of initial and subsequent measurements, the control procedures of measurement uncertainty applied in assessing the loss or remains found in handling operations of bulk liquids, when used turbine meters used in measuring the tax on the business of Petrobras, due to the current environment of legal metrology and scientific, both domestic and international. We aim, with these alternatives: standardizing the minimization of random and systematic errors, the estimate of the remaining errors, as well as the management control of metrological calibration procedures, control of measurement uncertainty, and contribute to the change in the form of performance of legal metrology and scientific disseminating new information to change management of metrological control, objectively focused on aspects of supervision in implementing these activities in the control of the uncertainties of measurement used in our processes in the fiscal measurement system Petrobras. Results are presented, information and comments on the influence of measurement uncertainty in the current results of the fiscal and transfer of custody. This will emphasize the need, among other things, improvement and expansion of metrological control monitored by setting a better meet demand, calibration equipment and measuring instruments for Petrobras. Finally, we intend to establish the need for improving the method of evaluation of the data meter applied to the current management control of measurement uncertainty by proposing a methodology for addressing the problem, as well as highlighting the expected results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Methods were developed for the analysis of acetonitrile and its metabolite cyanide in the blood of rats exposed to acetonitrile. Acetonitrile was analyzed by the headspace technique coupled to gas chromatography with detection by flame ionization, and cyanide was analyzed by high-performance liquid chromatography with fluorescence detection (λ ex = 418 nm and λ em = 460 nm) after derivatization of the ion with naphthalene 2,3-dicarboxyaldehyde and taurine. The quantitation limits of the methods for the analysis of acetonitrile and cyanide were 4.875 μg/mL and 0.025 μg/mL, respectively. The coefficients of variation of 10% or less obtained for intra- and interassay precision indicate the precision of these analytical methods and the systematic errors, all less than 5%, indicate that the methods are quite accurate. The methods were applied to an experimental study after the animals received acetonitrile at the doses of 2 mmol/kg or 5 mmol/kg.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Observable GNSS (Global Navigation Satellite System) are affected by systematic errors due to free electrons present in the ionosphere. The error associated with the ionosphere depends on the Total Electron Content (TEC), which is influenced by several variables: solar cycle, season, local time, geomagnetic activity and geographic location. The GPS (Global Positioning System), GLONASS (Global Orbiting Navigation Satellite System) and Galileo dual frequency receivers allow the calculation of the error that affects the GNSS observables and the TEC. Using the rate of change of TEC (ROT - Rate of TEC) indices that indicate irregularities of the ionosphere can be determined, allowing inferences about its behavior. Currently it is possible to perform such studies in Brazil, due to the several Active Networks available, such as RBMC/RIBaC (Rede Brasileira de Monitoramento Contínuo/Rede INCRA de Bases Comunitárias) and GNSS Active Network of São Paulo. The proposed research aimed at estimating and analysing of indexes of irregularities of the ionosphere, besides supplying the geosciences of information about the behavior of the ionosphere.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho apresenta uma contribuição aos estudos de modelagem climática com ênfase na variabilidade pluviométrica sazonal da Amazônia oriental, durante as estações de verão e outono (DJF e MAM). Baseado nos resultados das simulações regionais do RegCM3 para um período de 26 anos (1982/83 a 2007/08) e usando domínio em alta resolução espacial (30 Km) e dois diferentes esquemas de convecção (Grell e MIT), foi investigado o desempenho do modelo em simular a distribuição regional de precipitação sazonal na Amazônia oriental, com referência a um novo conjunto de dados observacional compilado com informações de uma ampla rede integrada de estações pluviométricas. As análises quantitativas evidenciaram que o RegCM3 apresenta erros sistemáticos, sobretudo aqueles relacionados com viés seco no Amapá e norte/nordeste do Pará usando ambos os esquemas Grell e MIT, os quais apontam que o modelo não reproduz as características da ZCIT sobre o Atlântico equatorial. As simulações usando MIT, também apresentaram viés úmido no sudoeste/sul/sudeste do Pará e norte do Tocantins. Além disso, através da técnica de composições, também foi investigado o desempenho do RegCM3 em reproduzir os padrões espaciais anômalos de precipitação sazonal em associação aos episódios ENOS, e as fases do gradiente térmico sobre o Atlântico intertropical. Os resultados demonstraram que o modelo conseguiu representar realisticamente bem o padrão espacial das anomalias pluviométricas acima (abaixo) do normal em grande parte da Amazônia oriental, durante os conhecidos cenários favoráveis, i.e., condições de La Niña e gradiente de aTSM para o Atlântico sul (desfavoráveis, i.e., El Niño e gradiente de aTSM para o Atlântico norte.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A seleção de métodos apropriados para a análise estatística pode parecer complexa, principalmente para estudantes de pós-graduação e pesquisadores no início da carreira científica. Por outro lado, a apresentação em PowerPoint é uma ferramenta comum para estudantes e pesquisadores. Assim, um tutorial de Bioestatística desenvolvido em uma apresentação em PowerPoint poderia estreitar a distância entre ortodontistas e a Bioestatística. Esse guia proporciona informações úteis e objetivas a respeito de vários métodos estatísticos empregando exemplos relacionados à Odontologia e, mais especificamente, à Ortodontia. Esse tutorial deve ser empregado, principalmente, para o usuário obter algumas respostas a questões comuns relacionadas ao teste mais apropriado para executar comparações entre grupos, examinar correlações e regressões ou analisar o erro do método. Também pode ser obtido auxílio para checar a distribuição dos dados (normal ou anormal) e a escolha do gráfico mais adequado para a apresentação dos resultados. Esse guia pode ainda ser de bastante utilidade para revisores de periódicos examinarem, de forma rápida, a adequabilidade do método estatístico apresentado em um artigo submetido à publicação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi agregar diferentes redes de estações meteorológicas de superfície para a criação de um novo banco de dados integrado, a partir do qual foi gerada uma climatologia recente (1978-2007) para a precipitação do estado do Pará em alta resolução espacial – 30 km, permitindo melhor identificar a variabilidade climática regional, sobretudo influenciada pelos aspectos da fisiografia e em função de mecanismos climáticos de grande escala dos oceanos Pacífico e Atlântico. Buscou-se, ainda, estabelecer uma configuração otimizada do modelo climático RegCM3 utilizando duas diferentes parametrizações de cumulus: RegCM3/Grell e RegCM3/MIT. Foram realizadas 26 simulações (1982/83 a 2007/08) durante a estação chuvosa na Amazônia oriental (dezembro a maio) para cada esquema de parametrização convectiva, utilizando 30 km de resolução espacial. O modelo mostrou-se capaz de capturar os sinais de anomalia na presença de forçantes climáticas extremas, como o El Niño-Oscilação Sul e o dipolo do Atlântico. O RegCM3/MIT obteve ótimo desempenho na região de Altamira/PA e performance razoável nos setores Nordeste (região de Belém), Leste ( região de Marabá), Sudeste (região de Conceição do Araguaia), e Noroeste (região de Tiriós). O RegCM3/Grell destacou-se nas regiões Nordeste, Leste, Sudeste e Noroeste, com desempenho razoável. O setor Norte (região de Macapá) foi o mais problemático, com pouca ou nenhuma sensibilidade apresentada pelo modelo. Embora o RegCM3 tenha obtido resultados razoáveis na maior parte do domínio, foram detectados erros sistemáticos nas simulações, com viés seco para o RegCM3/Grell e viés úmido para o RegCM3/MIT na porção Sul e viés seco na porção Norte. Estas características denotam a necessidade de ajustes às condições regionais dos esquemas de convecção.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciências Cartográficas - FCT