958 resultados para Surgical amputation
Resumo:
Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for amputees, particularly for individuals unable to wear a socket. However, the load transmitted through a typical TCBAP to the residual tibia and knee joint can be unbearable for transtibial amputees with knee arthritis. The aims of this study are (A) to describe the surgical procedure combining TKR with TCBAP for the first time; and (B) to present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up.
Resumo:
Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life. Most of these concerns can be overcome by surgical techniques enabling bone-anchored prostheses. In this case, the prosthesis is attached directly to the residual skeleton through a percutaneous implant. The aim of this study is to present the current advances in these surgical techniques worldwide with a strong focus on the developments in Australia and Queensland.
Resumo:
Osseointegration has been introduced in the orthopaedic surgery in the 1990’s in Gothenburg (Sweden). To date, there are two frequently used commercially available human implants: the OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany) systems. The rehabilitation program with both systems include some form of static load bearing exercises. These latter involved following a load progression that is monitored by the bathroom scale, providing only the load applied on the vertical axis. The loading data could be analysed through different biomechanical variables. For instance, the load compliance, corresponding to the difference between the load recommended (LR) and the load actually applied on the implant, will be presented here.
Resumo:
Typically, the walking ability of individuals with a transfemoral amputation (TFA) can be represented by the speed of walking (SofW) obtained in experimental settings. Recent developments in portable kinetic systems allow assessing the level of activity of TFA during actual daily living outside the confined space of a gait lab. Unfortunately, only minimal spatio-temporal characteristics could be extracted from the kinetic data including the cadence and the duration on gait cycles. Therefore, there is a need for a way to use some of these characteristics to assess the instantaneous speed of walking during daily living. The purpose of the study was to compare several methods to determine SofW using minimal spatial gait characteristics.
Resumo:
The rehabilitation programs of bone-anchorage prostheses relying either on the OPRA (Integrum, Sweden) or the ILP (Orthodynamics, Germany) fixation involve some forms of static load bearing exercises (LBE). So far, most of biomechanical studies of these static LBEs focused on the direct measurements of the actual forces and moments applied on the OPRA fixation of individuals with transfemoral amputation (TFA). To date, the proof-of-concept of an apparatus to conduct these kinetic measurements has been presented, along with some preliminary data. The understanding of the kinetic data is essential to improve rehabilitation programs as well as the design of upcoming loading frames. However, kinetic information alone is difficult to interpret without concomitant kinematic data. The purpose of this preliminary study was to introduce a qualitative analysis describing the different body postures during LBE for a group of TFAs.
Resumo:
Joint moments and joint powers are widely used to determine the effects of rehabilitation programs and prosthetic components (e.g., alignments). A complementary analysis of the 3D angle between joint moment and joint angular velocity has been proposed to assess whether the joints are predominantly driven or stabilized.
Resumo:
The prosthetic benefits of osseointegrated fixation for individuals with limb loss, particularly those with transfemoral amputation (TFA), have been clearly demonstrated in the literature. However, very little information is currently available to established how this prosthetic benefits are translated into functional outcomes and, more precisely, walking abilities [1-3]. The ultimate aim of this presentation was to explore how walking abilities of a TFA fitted with an OPRA fixation could be assess through typical temporal and spatial gait characteristics[2].
Resumo:
This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.
Resumo:
The understanding of the load applied on the residuum through the prosthesis of individuals with transfemoral amputation (TFA) is essential to address a number of concerns that could strongly reduce their quality of life (e.g., residuum skin lesion, prosthesis fitting, alignment). This inner prosthesis loading could be estimated using a typical gait laboratory relying on inverse dynamics equations. Alternative, technological advances proposed over the last decade enabled direct measurement of this kinetic information in a broad variety of situations that could potentially be more relevant in clinical settings. The purposes of this presentation are (A) to review the literature about recent developments in measure and analyses of inner prosthesis loading of TFA, and (B) to extract information that could potentially contribute to a better evidence-based practice.
Resumo:
The consequences of falls are often dreadful for individuals with lower limb amputation using bone-anchored prosthesis.[1-5] Typically, the impact on the fixation is responsible for bending the intercutaneous piece that could lead to a complete breakage over time. .[3, 5-8] The surgical replacement of this piece is possible but complex and expensive. Clearly, there is a need for solid data enabling an evidence-based design of protective devices limiting impact forces and torsion applied during a fall. The impact on the fixation during an actual fall is obviously difficult to record during a scientific experiment.[6, 8-13] Consequently, Schwartze and colleagues opted for one of the next best options science has to offer: simulation with an able-bodied participant. They recorded body movements and knee impacts on the floor while mimicking several plausible falling scenarios. Then, they calculated the forces and moments that would be applied at four levels along the femur corresponding to amputation heights.[6, 8-11, 14-25] The overall forces applied during the falls were similar regardless of the amputation height indicating that the impact forces were simply translated along the femur. As expected, they showed that overall moments generally increased with amputation height due to changes in lever arm. This work demonstrates that devices preventing only against force overload do not require considering amputation height while those protecting against bending moments should. Another significant contribution is to provide, for the time, the magnitude of the impact load during different falls. This loading range is crucial to the overall design and, more precisely, the triggering threshold of protective devices. Unfortunately, the analysis of only a single able-bodied participant replicating falls limits greatly the generalisation of the findings. Nonetheless, this case study is an important milestone contributing to a better understanding of load impact during a fall. This new knowledge will improve the treatment, the safe ambulation and, ultimately, the quality of life of individuals fitted with bone-anchored prosthesis.
Resumo:
Most of socket related discomforts leading to a significant decrease in quality of life of individuals with limb amputation can be overcome by surgical techniques enabling bone-anchored prostheses. To date, the OPRA two-stage procedure (i.e., S1, S2) is the most acknowledged treatment. However, surgical implantations of osseointegrated fixations are developing at an unprecedented pace worldwide.[1-18] Clearly, this option is becoming accessible to a wide range of individuals with limb amputations. The team led by Dr Rickard Branemark has published a number of landmark articles each focusing on a particular aspect (e.g., health related quality of life, functional outcomes, bone remodelling, infection rate). [1-3, 19-32] However, evidences presented in this prospective study are remarkable. Functional outcome, health-related quality of life and complications were considered concurrently for a large population (i.e., 51 participants) over an extended period of time (i.e., up to year follow up). Therefore, the “gain” and “pain” of the whole procedure were truly contrasted for the first time. The results confirmed that OPRA surgical and rehabilitation procedures improved significantly prosthetic use, mobility, global situation and fewer problems. Furthermore, the authors reported 47 episodes of infections for 63% (32) participants between post-op S1 and two years follow up. A total of 87% (41) were superficial infections recorded for 28 participants between post-op S2 and two years follow up, while 13% (6) were deep infections occurring for 4 participants during post-op S1 and S2. As expected, post-op S2 phase was the most prone to both infections. More importantly, the vast majority of infections were effectively treated with oral antibiotics. Clearly, this study provided definitive evidence that the benefits of OPRA fixation overcome complications. This article is also establishing reporting standards and benchmark data for future studies focusing on bone-anchored prostheses.
Resumo:
PURPOSE - To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen cross-linking (CXL) after intrastromal corneal ring (ISCR) implantation in patients with keratoconus. METHODS - Thirty-three patients (41 eyes) aged between 19 and 45 years were included in this prospective study. All patients underwent a femtosecond laser-enabled (Intralase FS; Abbott Medical Optics, Inc.) placement of intracorneal ring segments (Kerarings; Mediphacos, Brazil). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and keratometry readings remained stable for 6 months. Same-day PRK and CXL was subsequently performed in all patients. RESULTS - After 12 months of completion of the procedure, mean UDVA in log of minimal angle of resolution was significantly improved (0.74±0.54-0.10±0.16); CDVA did not improve significantly but 85% of eyes maintained or gained multiple lines of CDVA; mean refraction spherical equivalent improved (from -3.03±1.98 to -0.04±0.99 D), all keratometry readings were significantly reduced, from preoperative values, but coma did not vary significantly from preoperative values. Central corneal thickness and corneal thickness at the thinnest point were significantly (P<0.0001) reduced from 519.76±29.33 and 501.87±31.50 preoperatively to 464.71±36.79 and 436.55±47.42 postoperatively, respectively. Safety and efficacy indices were 0.97 and 0.88, respectively. From 6 months up until more than 1 year of follow-up, further significant improvement was observed only for UDVA (P<0.0001). CONCLUSIONS - Same-day combined TG-PRK and CXL after ISCR implantation is a safe and effective option for improving visual acuity and visual function, and it halts the progression of the keratoconus. The improvements recorded after 6 months of follow-up were maintained or improved upon 1 year after the procedure.
Resumo:
This symposium will provide hand-on update on the current development of the load sensors measuring the inner prosthetic loading that can strongly contribute the ever increasing demand for evidence-based clinical practice. Surgical implantations of osseointegrated fixations for bone-anchored prosthesis are developing at an unprecedented pace worldwide (e.g., Australia, UK, Sweden, US). This option is becoming accessible to a wide range of individuals with limb loss. With these new developments come new potential challenges and opportunities for all the stakeholders involved in the prosthetic care of these patients. Clearly, there is a need for those stakeholders, particularly those attending the ISPO, to be informed of the current and upcoming international developments in bone-anchored prostheses. The objectives of this symposium will be: • To present an overview of the current growth of the procedures worldwide (e.g., identification of key players, centers of activities, growth trend) with a strong focus on the introduction of the framework to evaluate the availability of the procedure at national level (e.g., number of patients treated, range of the levels of implantation, number of commercial fixations accessible), • To provide first-hand updates on the latest cutting-edge scientific and clinical developments of fixations and rehabilitations programs (e.g., Innovative design of implant, cost-effectiveness, long-terms rehabilitation outcomes for screw-type fixation, current developments in US, comparative analysis for press-fit type of implant, potential moves toward single-stage surgeries).
Resumo:
Background Surgical site infections (SSIs) are wound infections that occur after invasive (surgical) procedures. Preoperative bathing or showering with an antiseptic skin wash product is a well-accepted procedure for reducing skin bacteria (microflora). It is less clear whether reducing skin microflora leads to a lower incidence of surgical site infection. Objectives To review the evidence for preoperative bathing or showering with antiseptics for preventing hospital-acquired (nosocomial) surgical site infections. Search methods For this fifth update we searched the Cochrane Wounds Group Specialised Register (searched 18 December 2014); the Cochrane Central Register of Controlled Trials (The Cochrane Library 2014 Issue 11); Ovid MEDLINE (2012 to December Week 4 2014), Ovid MEDLINE (In-Process & Other Non-Indexed Citations December 18, 2014); Ovid EMBASE (2012 to 2014 Week 51), EBSCO CINAHL (2012 to December 18 2014) and reference lists of articles. Selection criteria Randomised controlled trials comparing any antiseptic preparation used for preoperative full-body bathing or showering with non-antiseptic preparations in people undergoing surgery. Data collection and analysis Two review authors independently assessed studies for selection, risk of bias and extracted data. Study authors were contacted for additional information. Main results We did not identify any new trials for inclusion in this fifth update. Seven trials involving a total of 10,157 participants were included. Four of the included trials had three comparison groups. The antiseptic used in all trials was 4% chlorhexidine gluconate (Hibiscrub/Riohex). Three trials involving 7791 participants compared chlorhexidine with a placebo. Bathing with chlorhexidine compared with placebo did not result in a statistically significant reduction in SSIs; the relative risk of SSI (RR) was 0.91 (95% confidence interval (CI) 0.80 to 1.04). When only trials of high quality were included in this comparison, the RR of SSI was 0.95 (95%CI 0.82 to 1.10). Three trials of 1443 participants compared bar soap with chlorhexidine; when combined there was no difference in the risk of SSIs (RR 1.02, 95% CI 0.57 to 1.84). Three trials of 1192 patients compared bathing with chlorhexidine with no washing, one large study found a statistically significant difference in favour of bathing with chlorhexidine (RR 0.36, 95%CI 0.17 to 0.79). The smaller studies found no difference between patients who washed with chlorhexidine and those who did not wash preoperatively. Authors' conclusions This review provides no clear evidence of benefit for preoperative showering or bathing with chlorhexidine over other wash products, to reduce surgical site infection. Efforts to reduce the incidence of nosocomial surgical site infection should focus on interventions where effect has been demonstrated.
Resumo:
"Using the nursing process as a framework for practice, the fourth edition has been extensively revised to reflect the rapid changing nature of nursing practice and the increasing focus on key nursing care priorities. Building on the strengths of the third Australian and New Zealand edition and incorporating relevant global nursing research and practice from the prominent US title Medical-Surgical Nursing, 9Th Edition, Lewis’s Medical-Surgical Nursing, 4th Edition is an essential resource for students seeking to understand the role of the professional nurse in the contemporary health environment."--Publisher website