936 resultados para Straight Tenckhoff catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. METHODS AND RESULTS: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43-73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070-7.143; P<0.001), left atrial diameter ≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078-4.016; P=0.03), continuous AF duration ≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024-3.846; P<0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037-3.388; P=0.04) predicted arrhythmia recurrence. CONCLUSIONS: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plus de la moitié des patients présentant une thrombose veineuse profonde des membres inférieurs développent un syndrome post-thrombotique. Le risque est particulièrement élevé en cas de thrombose de l'axe principal de drainage veineux comprenant la veine fémorale commune et les veines iliaques. Plusieurs études ont démontré que l'incidence du syndrome post-thrombotique peut être diminuée si une recanalisation des veines ilio-fémorales est obtenue dans la phase aiguë. A l'heure actuelle, des techniques de recanalisation percutanées sont proposées à des patients sélectionnés présentant une thrombose ilio-fémorale. Cet article a pour but de résumer les connaissances actuelles sur la recanalisation percutanée de la thrombose veineuse profonde aiguë. Nearly half of patients with acute lower limb deep vein thrombosis (DVT) develop a post-thrombotic syndrome (PTS). This risk is particularly high in case of proximal DVT of the common femoral and iliac vein, the major lower limbs venous outflow vessel. Several studies have demonstrated that PTS incidence can be reduced with early vein recanalisation. Currently, catheter-based recanalisation therapies can be offered to selected patients with acute ilio-femoral deep vein thrombosis. Aim of the present article is to summarize current knowledge on these catheter-based recanalisation therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous catheter ablation of atrial fibrillation (CA-AF) is a treatment option for symptomatic drug-refractory atrial fibrillation (AF). CA-AF carries a risk for thromboembolic complications that has been minimized by the use of intraprocedural intravenous unfractionated heparin (UFH). The optimal administration of UFH as well as its kinetics are not well established and need to be precisely determined. METHODS AND RESULTS: A total 102 of consecutive patients suffering from symptomatic drug-refractory AF underwent CA-AF. The mean age was 61 ± 10 years old. After transseptal puncture of the fossa ovalis, weight-adjusted UFH bolus (100 U/kg) was infused. A significant increase in activated clotting time (ACT) was observed from an average value of 100 ± 27 seconds at baseline, to 355 ± 94 seconds at 10 min (T10), to 375 ± 90 seconds at 20 min (T20). Twenty-four patients failed to reach the targeted ACT value of ≥300 seconds at T10 and more than half of these remained with subtherapeutic ACT values at T20. This subset of patients showed similar clinical characteristics and amount of UFH but were more frequently prescribed preprocedural vitamin K1 than the rest of the study population. CONCLUSIONS: In a typical intervention setting, UFH displays unexpected slow anticoagulation kinetics in a significant proportion of procedures up to 20 minutes after infusion. These findings support the infusion of UFH before transseptal puncture or any left-sided catheterization with early ACT measurements to identify patients with delayed kinetics. They are in line with recent guidelines to perform CA-AF under therapeutic anticoagulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal denervation can reduce blood pressure in patients with uncontrolled hypertension. The adherence to prescribed antihypertensive medication following renal denervation is unknown. This study investigated adherence to prescribed antihypertensive treatment by liquid chromatography-high resolution tandem mass spectrometry in plasma and urine at baseline and 6 months after renal denervation in 100 patients with resistant hypertension, defined as baseline office systolic blood pressure ≥140 mmHg despite treatment with ≥3 antihypertensive agents. At baseline, complete adherence to all prescribed antihypertensive agents was observed in 52 patients, 46 patients were partially adherent, and two patients were completely non-adherent. Baseline office blood pressure was 167/88 ± 19/16 mmHg with a corresponding 24-h blood pressure of 154/86 ± 15/13 mmHg. Renal denervation significantly reduced office and ambulatory blood pressure at 6-month follow-up by 15/5 mmHg (p < 0.001/p < 0.001) and 8/4 mmHg (p < 0.001/p = 0.001), respectively. Mean adherence to prescribed treatment was significantly reduced from 85.0 % at baseline to 80.7 %, 6 months after renal denervation (p = 0.005). The blood pressure decrease was not explained by improvements in adherence following the procedure. Patients not responding to treatment significantly reduced their drug intake following the procedure. Adherence was highest for angiotensin-converting enzyme inhibitors/angiotensin receptor blockers and beta blockers (>90 %) and lowest for vasodilators (21 %). In conclusion, renal denervation can reduce office and ambulatory blood pressure in patients with resistant hypertension despite a significant reduction in adherence to antihypertensive treatment after 6 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTE: L'ablation percutanée par cathéter de la fibrillation auriculaire (AC-FA) est une option de traitement pour les patients souffrant de fibrillation auriculaire (FA) symptomatique réfractaire au traitement médicamenteux. L'AC-FA comporte un risque de complications thromboemboliques qui a été réduit par l'utilisation de l'héparine non fractionnée (HNF) intraveineuse durant la procédure. L'administration optimale de l'HNF ainsi que sa cinétique ne sont pas bien établies et nécessitent d'être déterminées avec précision. MÉTHODES ET RÉSULTATS: Cette étude a inclus 102 patients consécutifs atteints de FA symptomatique, réfractaire au traitement médicamenteux, référés pour une AC-FA. L'âge moyen était de 61 ± 10 ans. Après une ponction transseptale de la fosse ovale, une injection intraveineuse de HNF ajustée au poids (100 U / kg) a été administré. Une augmentation significative du temps de coagulation activé (ACT) a été observée passant d'une valeur de base moyenne de 100 ± 27 secondes, à 355 ± 94 secondes à 10 minutes (T10) et à 375 ± 90 secondes à 20 minutes (T20). 24 patients n'ont pas atteint la valeur visée d'ACT > 300 secondes à T10 et plus de la moitié de ce collectif est resté avec les valeurs d'ACT infrathérapeutiques à T20. Ce sous-ensemble de patients avait des caractéristiques cliniques similaires et avait reçu des doses similaires d'HNF, mais s'était plus fréquemment fait prescrire de la vitamine Kl pré-procédurale que le reste de la population de l'étude. CONCLUSION: Au cours d'une intervention standard, l'HNF montre, de manière inattendue, une cinétique d'anticoagulation lente dans une proportion significative des procédures et ceci jusqu'à 20 minutes après l'administration. Ces résultats soutiennent l'importance d'une administration d'HNF avant la ponction transseptale ou tout cathétérisme gauche avec des mesures précoces et répétées d'ACT afin d'identifier les patients avec une cinétique retardée. Ils sont en ligne avec les directives récentes proposant d'effectuer l'AC-FA sous anticoagulation thérapeutique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El problema de la regresión simbólica consiste en el aprendizaje, a partir de un conjunto muestra de datos obtenidos experimentalmente, de una función desconocida. Los métodos evolutivos han demostrado su eficiencia en la resolución de instancias de dicho problema. En este proyecto se propone una nueva estrategia evolutiva, a través de algoritmos genéticos, basada en una nueva estructura de datos denominada Straight Line Program (SLP) y que representa en este caso expresiones simbólicas. A partir de un SLP universal, que depende de una serie de parámetros cuya especialización proporciona SLP's concretos del espacio de búsqueda, la estrategia trata de encontrar los parámetros óptimos para que el SLP universal represente la función que mejor se aproxime al conjunto de puntos muestra. De manera conceptual, este proyecto consiste en un entrenamiento genético del SLP universal, utilizando los puntos muestra como conjunto de entrenamiento, para resolver el problema de la regresión simbólica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las preguntas por los métodos en ciencias sociales parecen responderse con facilidad en los manuales, el simple ejercicio de definir el enfoque que utilizaremos (cuantitativo o cualitativo) supone la apertura a la claridad. En este sentido los cuestionamientos acerca de qué es lo que vamos a estudiar, por cuánto tiempo, quiénes conformarán nuestra muestra, cómo abordaremos a los sujetos de estudio, qué tipo de preguntas, encuestas o modalidades de conversación grupales aplicaremos, de qué modo validaremos nuestros resultados y tantas otras preguntas, aparecen como estrategias y técnicas metodológicas con simulaciones contextuales que en muchos aspectos aclaran los tecnicismos, pero que no agotan las múltiples críticas y preguntas que dichos métodos también presentan. En los métodos de manual, particularmente la etnografía, las estrategias aparecen unas seguidas de otras como una multiplicidad de opciones a la mano que podemos elegir según el imaginario que hemos proyectado inicialmente. Siguiendo las pautas tendemos a olvidar que los sujetos de estudio son personas hombres y mujeres que piensan, accionan y reaccionan de distintos modos afectando las metodologías y estrategias seleccionadas, de tal modo que el manual debe ser siempre el repertorio de opciones posibles de modificarse, nunca la guía final de nuestros estudios. Estos cuestionamientos acompañaron muchos de mis procesos y experiencias con los métodos de campo, a partir de los cuales presentaré algunos aspectos que me parece interesante exponer.