855 resultados para Stormont House Agreement
Resumo:
House dust is a heterogeneous matrix, which contains a number of biological materials and particulate matter gathered from several sources. It is the accumulation of a number of semi-volatile and non-volatile contaminants. The contaminants are trapped and preserved. Therefore, house dust can be viewed as an archive of both the indoor and outdoor air pollution. There is evidence to show that on average, people tend to stay indoors most of the time and this increases exposure to house dust. The aims of this investigation were to: " assess the levels of Polycyclic Aromatic Hydrocarbons (PAHs), elements and pesticides in the indoor environment of the Brisbane area; " identify and characterise the possible sources of elemental constituents (inorganic elements), PAHs and pesticides by means of Positive Matrix Factorisation (PMF); and " establish the correlations between the levels of indoor air pollutants (PAHs, elements and pesticides) with the external and internal characteristics or attributes of the buildings and indoor activities by means of multivariate data analysis techniques. The dust samples were collected during the period of 2005-2007 from homes located in different suburbs of Brisbane, Ipswich and Toowoomba, in South East Queensland, Australia. A vacuum cleaner fitted with a paper bag was used as a sampler for collecting the house dust. A survey questionnaire was filled by the house residents which contained information about the indoor and outdoor characteristics of their residences. House dust samples were analysed for three different pollutants: Pesticides, Elements and PAHs. The analyses were carried-out for samples of particle size less than 250 µm. The chemical analyses for both pesticides and PAHs were performed using a Gas Chromatography Mass Spectrometry (GC-MS), while elemental analysis was carried-out by using Inductively-Coupled Plasma-Mass Spectroscopy (ICP-MS). The data was subjected to multivariate data analysis techniques such as multi-criteria decision-making procedures, Preference Ranking Organisation Method for Enrichment Evaluations (PROMETHEE), coupled with Geometrical Analysis for Interactive Aid (GAIA) in order to rank the samples and to examine data display. This study showed that compared to the results from previous works, which were carried-out in Australia and overseas, the concentrations of pollutants in house dusts in Brisbane and the surrounding areas were relatively very high. The results of this work also showed significant correlations between some of the physical parameters (types of building material, floor level, distance from industrial areas and major road, and smoking) and the concentrations of pollutants. Types of building materials and the age of houses were found to be two of the primary factors that affect the concentrations of pesticides and elements in house dust. The concentrations of these two types of pollutant appear to be higher in old houses (timber houses) than in the brick ones. In contrast, the concentrations of PAHs were noticed to be higher in brick houses than in the timber ones. Other factors such as floor level, and distance from the main street and industrial area, also affected the concentrations of pollutants in the house dust samples. To apportion the sources and to understand mechanisms of pollutants, Positive Matrix Factorisation (PMF) receptor model was applied. The results showed that there were significant correlations between the degree of concentration of contaminants in house dust and the physical characteristics of houses, such as the age and the type of the house, the distance from the main road and industrial areas, and smoking. Sources of pollutants were identified. For PAHs, the sources were cooking activities, vehicle emissions, smoking, oil fumes, natural gas combustion and traces of diesel exhaust emissions; for pesticides the sources were application of pesticides for controlling termites in buildings and fences, treating indoor furniture and in gardens for controlling pests attacking horticultural and ornamental plants; for elements the sources were soil, cooking, smoking, paints, pesticides, combustion of motor fuels, residual fuel oil, motor vehicle emissions, wearing down of brake linings and industrial activities.
Resumo:
Just as telecommunications has played a key role in the global economy,1 high-speed broadband will have a significant role to play in the future of the digital economy. In particular high-speed broadband will have a role to play in the delivery of applications and services necessary for acquiring, and maintaining into the future Australia and Australians’ appropriate education level; community; health services, information provision and support; government services and engagement and participation by the public in the political process.
Resumo:
Poem
Resumo:
While strengthened partnerships between University and Schools have been proposed in recent reviews of teacher education (House of Representative Standing Committee on Education and Vocational Training, 2007; Caldwell & Sutton, 2010; Donaldson, 2010), there is a need to understand the benefits and challenges for participants of these partnerships. The Teacher Education Centre of Excellence (TECE) in this study is a preservice teacher preparation partnership between a Queensland University, Queensland Department of Education, Training and Employment (DETE) and an Education Queensland school. It was established in response to a mandated reform within the Improving Teacher Quality National Partnership Agreement (Department of Education Employment and Workplace Relations, 2011). High-achieving Bachelor of Education preservice teachers apply to be part of the 18-month program in the third year of their four-year Education degree. These preservice teachers experience mentoring in partner schools in addition to course work designed and delivered by a DETE appointed Head of Mentoring and a university academic. On completion of the program, graduates will be appointed to South West Queensland rural and remote Education Queensland schools. This paper analyses participant perspectives from the first phase of this partnership in particular identifying the benefits and challenges experienced by the preservice teachers and the leaders of the program from the participating institutions. A sociocultural theoretical perspective (Wenger, 1998) informed the analysis examining how preservice teachers experience a sense of becoming a professional teacher within a specific employment context. Data from interviews with 6 pre-service teachers and 8 program leaders were analysed inductively through coding of interview records. Findings indicate the importance of strong relationships and opportunity for reciprocal learning through ongoing professional conversations as contexts for preservice teachers to develop an identity as an emerging professional. This research has significance for the ongoing development of this partnership as well as informing the principles for the design of future similar partnerships.
Resumo:
STUDY QUESTION: What is the self-reported use of in vitro fertilization (IVF) and ovulation induction (OI) in comparison with insurance claims by Australian women aged 28–36 years? SUMMARY ANSWER: The self-reported use of IVF is quite likely to be valid; however, the use of OI is less well reported. WHAT IS KNOWN AND WHAT THIS PAPER ADDS: Population-based research often relies on the self-reported use of IVF and OI because access to medical records can be difficult and the data need to include sufficient personal identifying information for linkage to other data sources. There have been few attempts to explore the reliability of the self-reported use of IVF and OI using the linkage to medical insurance claims for either treatment. STUDY DESIGN: This prospective, population-based, longitudinal study included the cohort of women born during 1973–1978 and participating in the Australian Longitudinal Study on Women's Health (ALSWH) (n = 14247). From 1996 to 2009, participants were surveyed up to five times. PARTICIPANTS AND SETTING: Participants self-reported their use of IVF or OI in two mailed surveys when aged 28–33 and 31–36 years (n = 7280), respectively. This study links self-report survey responses and claims for treatment or medication from the universal national health insurance scheme (i.e. Medicare Australia). MAIN RESULTS AND THE ROLE OF CHANCE: Comparisons between self-reports and claims data were undertaken for all women consenting to the linkage (n = 3375). The self-reported use of IVF was compared with claims for OI for IVF (Kappa, K = 0.83), oocyte collection (K = 0.82), sperm preparation (K = 0.83), intracytoplasmic sperm injection (K = 0.40), fresh embryo transfers (K = 0.82), frozen embryo transfers (K = 0.64) and OI for IVF medication (K = 0.17). The self-reported use of OI was compared with ovulation monitoring (K = 0.52) and OI medication (K = 0.71). BIAS, CONFOUNDING AND OTHER REASONS FOR CAUTION: There is a possibility of selection bias due to the inclusion criteria for participants in this study: (1) completion of the last two surveys in a series of five and (2) consent to the linkage of their responses with Medicare data. GENERALIZABILITY TO OTHER POPULATIONS: The results are relevant to questionnaire-based research studies with infertile women in developed countries. STUDY FUNDING/COMPETING INTEREST(S): ALSWH is funded by the Australian Government Department of Health and Ageing. This research is funded by a National Health and Medical Research Council Centre of Research Excellence grant.
Resumo:
Background The onsite treatment of sewage and effluent disposal within the premises is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the seemingly low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. Therefore it is important that careful consideration is given to the design and location of onsite sewage treatment systems. It requires an understanding of the factors that influence treatment performance. The use of subsurface effluent absorption systems is the most common form of effluent disposal for onsite sewage treatment and particularly for septic tanks. Additionally in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Therefore location specific factors will play a key role in this context. The project The primary aims of the research project are: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to identify important areas where there is currently a lack of relevant research knowledge and is in need of further investigation. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of the research project has been on septic tanks. Therefore by implication the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. In the evaluation to be undertaken, the treatment performance of soil absorption systems will be related to the physico-chemical characteristics of the soil. Five broad categories of soil types have been considered for this purpose. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each soil types. In the initial phase of the investigation, though the majority of the systems evaluated were septic tanks, a small number of aerobic wastewater treatment systems (AWTS) were also included. This was primarily to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of different types of systems investigated was relatively small. As such this does not permit a statistical analysis to be undertaken of the results obtained. This is an important issue considering the large number of parameters that can influence treatment performance and their wide variability. The report This report is the second in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The work undertaken included site investigation and testing of sewage effluent and soil samples taken at distances of 1 and 3 m from the effluent disposal area. The project component discussed in the current report formed the basis for the more detailed investigation undertaken subsequently. The outcomes from the initial studies have been discussed, which enabled the identification of factors to be investigated further. Primarily, this report contains the results of the field monitoring program, the initial analysis undertaken and preliminary conclusions. Field study and outcomes Initially commencing with a list of 252 locations in 17 different suburbs, a total of 22 sites in 21 different locations were monitored. These sites were selected based on predetermined criteria. To obtain house owner agreement to participate in the monitoring study was not an easy task. Six of these sites had to be abandoned subsequently due to various reasons. The remaining sites included eight septic systems with subsurface effluent disposal and treating blackwater or combined black and greywater, two sites treating greywater only and six sites with AWTS. In addition to collecting effluent and soil samples from each site, a detailed field investigation including a series of house owner interviews were also undertaken. Significant observations were made during the field investigations. In addition to site specific observations, the general observations include the following: • Most house owners are unaware of the need for regular maintenance. Sludge removal has not been undertaken in any of the septic tanks monitored. Even in the case of aerated wastewater treatment systems, the regular inspections by the supplier is confined only to the treatment system and does not include the effluent disposal system. This is not a satisfactory situation as the investigations revealed. • In the case of separate greywater systems, only one site had a suitably functioning disposal arrangement. The general practice is to employ a garden hose to siphon the greywater for use in surface irrigation of the garden. • In most sites, the soil profile showed significant lateral percolation of effluent. As such, the flow of effluent to surface water bodies is a distinct possibility. • The need to investigate the subsurface condition to a depth greater than what is required for the standard percolation test was clearly evident. On occasion, seemingly permeable soil was found to have an underlying impermeable soil layer or vice versa. The important outcomes from the testing program include the following: • Though effluent treatment is influenced by the physico-chemical characteristics of the soil, it was not possible to distinguish between the treatment performance of different soil types. This leads to the hypothesis that effluent renovation is significantly influenced by the combination of various physico-chemical parameters rather than single parameters. This would make the processes involved strongly site specific. • Generally the improvement in effluent quality appears to take place only within the initial 1 m of travel and without any appreciable improvement thereafter. This relates only to the degree of improvement obtained and does not imply that this quality is satisfactory. This calls into question the value of adopting setback distances from sensitive water bodies. • Use of AWTS for sewage treatment may provide effluent of higher quality suitable for surface disposal. However on the whole, after a 1-3 m of travel through the subsurface, it was not possible to distinguish any significant differences in quality between those originating from septic tanks and AWTS. • In comparison with effluent quality from a conventional wastewater treatment plant, most systems were found to perform satisfactorily with regards to Total Nitrogen. The success rate was much lower in the case of faecal coliforms. However it is important to note that five of the systems exhibited problems with regards to effluent disposal, resulting in surface flow. This could lead to possible contamination of surface water courses. • The ratio of TDS to EC is about 0.42 whilst the optimum recommended value for use of treated effluent for irrigation should be about 0.64. This would mean a higher salt content in the effluent than what is advisable for use in irrigation. A consequence of this would be the accumulation of salts to a concentration harmful to crops or the landscape unless adequate leaching is present. These relatively high EC values are present even in the case of AWTS where surface irrigation of effluent is being undertaken. However it is important to note that this is not an artefact of the treatment process but rather an indication of the quality of the wastewater generated in the household. This clearly indicates the need for further research to evaluate the suitability of various soil types for the surface irrigation of effluent where the TDS/EC ratio is less than 0.64. • Effluent percolating through the subsurface absorption field may travel in the form of dilute pulses. As such the effluent will move through the soil profile forming fronts of elevated parameter levels. • The downward flow of effluent and leaching of the soil profile is evident in the case of podsolic, lithosol and kransozem soils. Lateral flow of effluent is evident in the case of prairie soils. Gleyed podsolic soils indicate poor drainage and ponding of effluent. In the current phase of the research project, a number of chemical indicators such as EC, pH and chloride concentration were employed as indicators to investigate the extent of effluent flow and to understand how soil renovates effluent. The soil profile, especially texture, structure and moisture regime was examined more in an engineering sense to determine the effect of movement of water into and through the soil. However it is not only the physical characteristics, but the chemical characteristics of the soil also play a key role in the effluent renovation process. Therefore in order to understand the complex processes taking place in a subsurface effluent disposal area, it is important that the identified influential parameters are evaluated using soil chemical concepts. Consequently the primary focus of the next phase of the research project will be to identify linkages between various important parameters. The research thus envisaged will help to develop robust criteria for evaluating the performance of subsurface disposal systems.
Resumo:
The Old Government House, a former residence of the Queen’s representatives in Brisbane, Australia, symbolises British cultural heritage of Colonial Queensland. Located on the campus of the Queensland University of Technology, it is one of the oldest surviving examples of a stately residence in Queensland. Built in 1860s, the Old Government House was originally intended as a temporary residence for the first governor of the newly independent colony of Queensland. However, it remained the vice-regal residence until 1909, serving eleven succeeding governors. Nearly seven decades later, it became the first building in Queensland to be protected under heritage legislation. Thus its importance, as an excellent exemplar that demonstrates the significance of cultural heritage, was established. The Old Government House has survived 150 years of restoration work, refurbishments, and additions. Through these years, it has served the people of Queensland in a multitude of roles. This paper aims to investigate the survival of heritage listed buildings through their adaptive re-use. Its focus will be on the adaptive reuse of the Old Government House through its refurbishments and additions over a period of 150 years. Through a qualitative research process this paper will endeavour to establish the significance of restoration work on the Old Government house; the new opportunities that has opened up as a result of the restoration work; the continued maintenance and management of the building through adaptive re-use; the economic benefits of restoration work; and its contribution to the on-going interest in the preservation of the Tangible Cultural Heritage.
Resumo:
22 mins documentary
Resumo:
The present paper presents and discusses the use of dierent codes regarding the numerical simulation of a radial-in ow turbine. A radial-in ow turbine test case was selected from published literature [1] and commercial codes (Fluent and CFX) were used to perform the steady-state numerical simulations. An in-house compressible- ow simulation code, Eilmer3 [2] was also adapted in order to make it suitable to perform turbomachinery simulations and preliminary results are presented and discussed. The code itself as well as its adaptation, comprising the addition of terms for the rotating frame of reference, programmable boundary conditions for periodic boundaries and a mixing plane interface between the rotating and non-rotating blocks are also discussed. Several cases with dierent orders of complexity in terms of geometry were considered and the results were compared across the dierent codes. The agreement between these results and published data is also discussed.