948 resultados para Steam-heating


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A differential temperature controller is incorporated in a solar water heating system to study the influence of its set points on system performance. The effectiveness of the controller set points DeltaT ON and DeltaT OFF on the pump cycling and energy collection has been studied experimentally and the results are presented in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local heating is an important parameter in compaction of thermally sensitive solids since local hot spots could conceivably raise the temperature of the system by several hundred degrees. To understand the importance of local hot spots, 20 g of ammonium perchlorate (AP) and potassium perchlorate (KP) were pressed together at 1500 kg cm−2 for 5 min. The surface structural examination of the compact revealed a secondary phase at the interfaces between the grains in the compositions ranging from 50% AP-50% KP to 10% AP-90% KP. The observation of the secondary phase only at the interfaces has been attributed to the short life times of temperature pulses present during the compaction. An interesting aspect of the investigation is the formation of a series of solid solutions of AP-KP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative differential resistance (NDR) in current-voltage (I-V) characteristics and apparent colossal electroresistance were observed in Gd0.5Sr0.5MnO3 single crystals at low temperatures. The continuous dc I-V measurements showed a marked thermal drift. In addition, temperature of the sample surface was found to be significantly higher than that of the base at high applied currents. Two different strategies namely estimation and diminution of the Joule heating (pulsed I-V measurements) were employed to investigate its role in the electric transport properties. Our experiments reveal that the NDR in Gd0.5Sr0.5MnO3 is a consequence of Joule heating rather than the melting of charge order. (C) 2010 American Institute of Physics. doi:10.1063/1.3486221]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effective heating values of the above and below ground biomass components of mature Scots pine (Pinus sylvestris), Norway spruce (Picea abies), downy birch (Betula pubescens), silver birch (Betula pendula), grey alder (Alnus incana), black alder (Alnus glutinosa) and trembling aspen (Populus tremula) were studied. Each sample tree was divided into wood, bark and foliage components. Bomb calorimetry was used to determine the calorimetric heating values. The species is a significant factor in the heating value of individual tree components. The heating value of the wood proper is highest in conifers. Broad-leaved species have a higher heating value of bark than conifers. The species factor diminishes when the weighted heating value of crown, whole stems or stump-root-system are considered. The crown material has a higher heating value per unit weight in comparison with fuelwood from small-sized stems or wholetrees. The additional advantages of coniferous crown material are that it is a non-industrial biomass resource and is readily available. The variability of both the chemical composition and the heating value is small in any given tree component of any species. However, lignin, carbohydrate and extractive content were found to vary from one part of the tree to another and to correlate with the heating value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gels of various composition containing SiO2, Al2O3, and P2O5 have been investigated by employing high resolution magic-angle-spinning (MAS) 27Al, 29Si, and 31P NMR spectroscopy. Changes occurring in the NMR spectra as the gels are progressively heated have been examined to understand the nature of structural changes occurring during the crystallization of the gels. 27Al resonance is sensitive to changes in the coordination number even when the Al concentration is as low as 1 mol%. As the percentage of Al increases, the hydroxyl groups tend to be located on the Al sites while Si remains as SiO4/2 (Q4). Mullite is the major phase formed at higher temperature in the aluminosilicate gels. In the case of the silicophosphate gels, Si is present in the form of Q4 and Q3 species. There is a change in the coordination of Si from four to six as the gel is heated. The formation of six-coordinated Si is facilitated even at lower temperatures (~673 K) when the P2O5 content is high. The phosphorus atoms present as orthophosphoric acid units in the xerogels change over to metaphosphate-like units as the gel is heated to higher temperatures. In aluminosilicophosphates, Si is present as Q4 and Q3 species while P is present as metaphosphate units; Al in these gels seems to be inducted into the tetrahedral network positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three types of conventional solar air heater are designed such that their heat absorbing areas and the pressure drops across them are equal for equal air mass flow rates per unit collector area. The results of thermal performance tests conducted simultaneously on these collectors, under the same environmental conditions, are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical solution for the transient temperature distribution in a cylindrical disc heated on its top surface by a circular source is presented. A finite difference form of the governing equations is solved by the Alternating Direction Implicit (ADI) time marching scheme. This solution has direct applications in analyzing transient electron beam heating of target materials as encountered in the prebreakdown current enhancement and consequent breakdown in high voltage vacuum gaps stressed by alternating and pulsed voltages. The solution provides an estimate of the temperature for pulsed electron beam heating and the size of thermally activated microparticles originating from anode hot spots. The calculated results for a typical 45kV (a.c.) electron beam of radius 2.5 micron indicate that the temperature of such spots can reach melting point and could give rise to microparticles which could initiate breakdown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The coherent plasma process such as parametric decay instability (PDI) has been applied to a homogeneous and unmagnetized plasma. These instabilities cause anomalous absorption of strong electromagnetic radiation under specific conditions of energy and momentum conservation and thus cause anomalous heating of the plasma. The maximum plasma temperatures reached are functions of luminosity of the radio radiation and plasma parameters. We believe that these processes may be taking place in many astrophysical objects. Here, the conditions in the sources 3C 273, 3C 48 and Crab Nebula are shown to be conducive to the excitation of PDI. These processes also contribute towards the absorption of 21cm radiation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The restricted three-body method is used to model the effect of the mean tidal field of a cluster of galaxies on the internal dynamics of a disk galaxy falling into the cluster for the first time. In the model adopted the galaxy experiences a tidal field that is compressive within the core of the cluster. The planar random velocities of all components in the disk increase after the galaxy passes through the core of the cluster. The low-velocity dispersion gas clouds experience a relatively larger increase in random velocity than the hotter stellar components. The increase in planar velocities results in a strong anisotropy between the planar and vertical velocity dispersions. It is argued that this will make the disk unstable to the 'fire-hose instability' which leads to bending modes in the disk and which will thicken the disk slightly. The mean tidal fields in rich clusters were probably stronger during the epoch of cluster formation and relaxation than they are in present-day relaxed clusters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some recent observations at Pic-du-Midi (Mulleret al., 1992a) suggest that the photospheric footpoints of coronal magnetic field lines occasionally move rapidly with typical velocities of the order 3 km s–1 for about 3 or 4 min. We argue that such occasional rapid footpoint motions could have a profound impact on the heating of the quiet corona. Qualitative estimates indicate that these occasional rapid motions can account for the entire energy flux needed to heat the quiet corona. We therefore carry out a mathematical analysis to study in detail the response of a vertical thin flux tube to photospheric footpoint motions in terms of a superposition of linear kink modes for an isothermal atmosphere. We find the resulting total energy that is asymptotically injected into an isothermal atmosphere (i.e., an atmosphere without any back reflection). By using typical parameter values for fast and slow footpoint motions, we show that, even if the footpoints spend only 2.5% of the time undergoing rapid motions, still these rapid motions could be more efficient in transporting energy to the corona than the slow motions that take place most of the time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AlxGa1-xN alloys with x=0.375, 0.398, 0.401, 0.592 and 0.696 were deposited on sapphire substrate by the hydride-vapor-phase epitaxy (HVPE) method. Thermal effusivity measurements were carried out on AlxGa1-xN alloys using a thermal microscope at room temperature. The lag between sinusoidal heating laser wave and thermoreflectance wave was used to measure the thermal diffusivity. Thermal conductivity values of the AlxGa1-xN alloys were also obtained as a function of AIN mole fraction in the alloy. The thermal conductivity was found to decrease with increasing AIN fraction and the experimental data agree with values estimated using the virtual crystal model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new working pairs, R21-NMP and R21-DMA, find potential application as working pairs for the single stage Resorption Heat Pump (RHP) and the Resorption Heat Transformer (RHT) cycles. A thermodynamic cycle analysis with these pairs shows that single stage RHPs have high COPs in their entire range of operation. RHTs show higher temperature boosts (up to 47 K) than the simple absorption heat transformers. Absorber temperatures of up to 400 K can be achieved in a single stage RHT system using R21 as the refrigerant. However, absorption-resorption systems have inherent limitations on the range of operating temperatures. Besides, they necessitate a higher pump work as compared to simple single stage absorption heating systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of microwave heating technique for the acceleration of ortho ester Claisen rearrangement (a three step transformation) is described. Irradiation of a DMF solution of the allyl alcohol 5, triethyl orthoacetate and propionic acid (catalytic) in an Erlenmeyer flask for 10 minutes in a microwave oven generated the ester 8 in 83% yield. Analogously, ortho ester Claisen rearrangement of a variety of allyl and propargyl alcohols (9, 12-22) were achieved. The formation of the diester 10 from 2-butyne-1,4-diol (9) via the ortho ester Claisen rearrangement of two allyl alcohol moieties (involving sh steps) in 15 minutes, demonstrates the versatility of the microwave heating technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of a thermodynamic cycle analysis of single stage resorption heat pump (RHP) and resorption heat transformer (RHT) cycles with the new working pairs R22-NMP and R22-DMA. The coefficients of performance (COP) are correlated with the low grade source temperature, temperature at which useful heat is obtained and ambient temperature. The COPs are in the range 1.20–1.60 for the RHP mode and 0.25–0.45 for the RHT mode. Absorber temperatures (useful temperatures) as high as 50°C in the RHP mode and 87°C in the RHT mode have been obtained. It is observed that absorption-resorption systems are inflexible in their range of operating temperature and necessitate a higher pump work as compared with simple single-stage absorption heating systems. However, single stage RHTs show higher temperature boosts than simple absorption heat transformers.