992 resultados para Standard dose


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose/Objective(s): RTwith TMZ is the standard for GBM. dd TMZ causes prolongedMGMTdepletion in mononuclear cells and possibly in tumor. The RTOG 0525 trial (ASCO 2011) did not show an advantage from dd TMZ for survival or progression free survival. We conducted exploratory, hypothesis-generating subset analyses to detect possible benefit from dd TMZ.Materials/Methods: Patients were randomized to std (150-200 mg/m2 x 5 d) or dd TMZ (75-100 mg/m2 x 21 d) q 4 weeks for 6- 12 cycles. Eligibility included age.18, KPS$ 60, and. 1 cm2 tissue for prospective MGMTanalysis for stratification. Furtheranalyses were performed for all randomized patients (''intent-to-treat'', ITT), and for all patients starting protocol therapy (SPT). Subset analyses were performed by RPA class (III, IV, V), KPS (90-100, = 50,\50), resection (partial, total), gender (female, male), and neurologic dysfunction (nf = none, minor, moderate).Results: No significant difference was seen for median OS (16.6 vs. 14.9 months), or PFS (5.5 vs. 6.7 months, p = 0.06). MGMT methylation was linked to improved OS (21.2 vs. 14 months, p\0.0001), and PFS (8.7 vs. 5.7 months, p\0.0001). For the ITT (n = 833), there was no OS benefit from dd TMZ in any subset. Two subsets showed a PFS benefit for dd TMZ: RPA class III (6.2 vs. 12.6 months, HR 0.69, p = 0.03) and nf = minor (HR 0.77, p = 0.01). For RPA III, dd dramatically delayed progression, but post-progression dd patients died more quickly than std. A similar pattern for nf = minor was observed. For the SPT group (n = 714) there was neither PFS nor OS benefit for dd TMZ, overall. For RPA class III and nf = minor, there was a PFS benefit for dd TMZ (HR 0.73, p = 0.08; HR 0.77, p = 0.02). For nf = moderate subset, both ITT and SPT, the std arm showed superior OS (14.4 vs. 10.9 months) compared to dd, without improved PFS (HR 1.46, p = 0.03; and HR 1.74, p = 0.01. In terms of methylation status within this subset, there were more methylated patients in the std arm of the ITT subset (n = 159; 32 vs. 24%). For the SPT subset (n = 124), methylation status was similar between arms.Conclusions: This study did not demonstrate improved OS for dd TMZ for any subgroup, but for 2 highly functional subgroups, PFS was significantly increased. These data generate the testable hypothesis that intensive treatment may selectively improve disease control in those most likely able to tolerate dd therapy. Interpretation of this should be considered carefully due to small sample size, the process of multiple observations, and other confounders.Acknowledgment: This project was supported by RTOG grant U10 CA21661, and CCOP grant U10 CA37422 from the National Cancer Institute (NCI).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Radiotherapy with concomitant and adjuvant TMZ is the standard of care for newly diagnosed GBM. MGMT methylation status may be an important determinant of treatment response. This trial, conducted by the RTOG, EORTC, and NCCTG, determined if intensified TMZ improves survival (OS) or progression free survival (PFS) in all patients or specific to MGMT status. Eligibility criteria included age . 18 yrs, KPS ≥ 60, and existence of a tissue block with . 1cm2 tumor for prospective MGMT and retrospective molecular analysis. Patients were randomized to Arm 1: standard TMZ (150-200 mg/m2 x 5 d) or Arm 2: dd TMZ (75-100 mg/m2 x 21 d) q 4 wks for 6-12 cycles. Symptom burden, quality of life (QOL), and neurocognition were prospectively and longitudinally assessed in a patient subset. 833 patients were randomized (1173 registered). Inadequate tissue (n ¼ 144) was the most frequent reason for nonrandomization.No statistical difference was observed between Arms 1 and 2 for median OS (16.6, 14.9 mo, p ¼ 0.63), median PFS (5.5, 6.7 mo, p ¼ 0.06), or methylation status. MGMT methylation was associated with improved OS (21.2, 14 mo, p , 0.0001), PFS (8.7, 5.7 mo, p , 0.0001), and treatment response (p ¼ 0.012). Cox modeling identifiedMGMT status and RPA class as significant predictors of OS; treatment arm and radiation technique (EORTC vs. RTOG) were not. There was increased grade ≥ 3 toxicity in Arm 2 (19%, 27%, p ¼ 0.008), which was mostly lymphopenia and fatigue. This study did not demonstrate improved efficacy for dd TMZ for newly diagnosed GBM regardless of methylation status. However, it confirmed the prognostic significance of MGMT methylation in GBM, demonstrated the feasibility of tumor tissue collection, molecular stratification, and collection of patient outcomes in a large transatlantic intergroup trial, thereby establishing a viable clinical trial paradigm. Support: NCI U10 CA 21661 and U10 CA37422.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectifs: Comparer la qualité d'image entre des protocoles dose-standard avec rétroprojection filtrée et basse-dose avec reconstruction itérative en scanner du rachis cervical. Matériels et méthodes: 40 patients ont été investigués par scanner du rachis cervical et prospectivement randomisés en 2 groupes: dose-standard (120kV, 275mAs) avec rétroprojection filtrée, basse-dose (120kV, 150mAs) avec reconstruction itérative. Mesure du bruit, signal-sur-bruit et contraste-sur-bruit. Analyse semi-quantitative (4 points) par 2 observateurs indépendants des disques, foramens, cordon médullaire, ligaments, parties molles et vertèbres, en C3-C4 et C6-C7. Evaluation semi-quantitative (10 points) de la qualité d'image globale. Les paramètres de dose ont été mesurés. Résultats: Il n'y avait aucune différence significative de bruit, signal-sur-bruit ou contraste-sur-bruit entre les 2 protocoles (p≥0.39). En basse-dose avec reconstruction itérative, la visibilité était significativement meilleure pour les disques, foramens et ligaments (p≤0.05), égale pour le cordon médullaire et moins bonne pour les parties molles et vertèbres (p≤0.02). La qualité d'image globale était meilleure, avec une réduction de dose de 41%. Conclusion: Le scanner du rachis cervical basse-dose avec reconstruction itérative fournit des images égales ou meilleures pour les disques, foramens et ligaments, tout en réduisant la dose d'environ 40%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Computed tomography (CT) accounts for more than half of the total radiation exposure from medical procedures, which makes dose reduction in CT an effective means of reducing radiation exposure. We analysed the dose reduction that can be achieved with a new CT scanner [Somatom Edge (E)] that incorporates new developments in hardware (detector) and software (iterative reconstruction). METHODS We compared weighted volume CT dose index (CTDIvol) and dose length product (DLP) values of 25 consecutive patients studied with non-enhanced standard brain CT with the new scanner and with two previous models each, a 64-slice 64-row multi-detector CT (MDCT) scanner with 64 rows (S64) and a 16-slice 16-row MDCT scanner with 16 rows (S16). We analysed signal-to-noise and contrast-to-noise ratios in images from the three scanners and performed a quality rating by three neuroradiologists to analyse whether dose reduction techniques still yield sufficient diagnostic quality. RESULTS CTDIVol of scanner E was 41.5 and 36.4 % less than the values of scanners S16 and S64, respectively; the DLP values were 40 and 38.3 % less. All differences were statistically significant (p < 0.0001). Signal-to-noise and contrast-to-noise ratios were best in S64; these differences also reached statistical significance. Image analysis, however, showed "non-inferiority" of scanner E regarding image quality. CONCLUSIONS The first experience with the new scanner shows that new dose reduction techniques allow for up to 40 % dose reduction while still maintaining image quality at a diagnostically usable level.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To develop a standard weight descriptor that can be used for estimation of patient size for obese patients. Patients and methods: Data were available from 3849 patients: 2839 from oncology patients (index data set) and 1010 from general medical patients (validation data set). The patients had a wide range of age (16-100 years), weight (25-165kg) and body mass index (BMI) [12-52 kg/m(2)] in both data sets. From the normal-weight patients in the oncology data set, an equation for male and female patients was developed to predict their normal weight as the sum of the lean body mass and normal fat body mass. The equations were evaluated by predicting the weight of patients in the general medical data set who had a normal BMI (30 kg/m(2)).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main contribution of this thesis is the proposal of novel strategies for the selection of parameters arising in variational models employed for the solution of inverse problems with data corrupted by Poisson noise. In light of the importance of using a significantly small dose of X-rays in Computed Tomography (CT), and its need of using advanced techniques to reconstruct the objects due to the high level of noise in the data, we will focus on parameter selection principles especially for low photon-counts, i.e. low dose Computed Tomography. For completeness, since such strategies can be adopted for various scenarios where the noise in the data typically follows a Poisson distribution, we will show their performance for other applications such as photography, astronomical and microscopy imaging. More specifically, in the first part of the thesis we will focus on low dose CT data corrupted only by Poisson noise by extending automatic selection strategies designed for Gaussian noise and improving the few existing ones for Poisson. The new approaches will show to outperform the state-of-the-art competitors especially in the low-counting regime. Moreover, we will propose to extend the best performing strategy to the hard task of multi-parameter selection showing promising results. Finally, in the last part of the thesis, we will introduce the problem of material decomposition for hyperspectral CT, which data encodes information of how different materials in the target attenuate X-rays in different ways according to the specific energy. We will conduct a preliminary comparative study to obtain accurate material decomposition starting from few noisy projection data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Data: Photodynamic therapy (PDT) involves the photoinduction of cytotoxicity using a photosensitizer agent, a light source of the proper wavelength, and the presence of molecular oxygen. A model for tissue response to PDT based on the photodynamic threshold dose (Dth) has been widely used. In this model cells exposed to doses below Dth survive while at doses above the Dth necrosis takes place. Objective: This study evaluated the light Dth values by using two different methods of determination. One model concerns the depth of necrosis and the other the width of superficial necrosis. Materials and Methods: Using normal rat liver we investigated the depth and width of necrosis induced by PDT when a laser with a gaussian intensity profile is used. Different light doses, photosensitizers (Photogem, Photofrin, Photosan, Foscan, Photodithazine, and Radachlorin), and concentrations were employed. Each experiment was performed on five animals and the average and standard deviations were calculated. Results: A simple depth and width of necrosis model analysis allows us to determine the threshold dose by measuring both depth and surface data. Comparison shows that both measurements provide the same value within the degree of experimental error. Conclusion: This work demonstrates that by knowing the extent of the superficial necrotic area of a target tissue irradiated by a gaussian light beam, it is possible to estimate the threshold dose. This technique may find application where the determination of Dth must be done without cutting the tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. Chronic rhinosinusitis (CRS) is a risk factor for asthma exacerbations and is associated with greater clinical severity. Discrepancies may exist between CRS clinical diagnosis and data from paranasal sinus (PS) X-ray or computed tomography (CT) scans. The objective was to compare PS involvement using low-dose CT and plain X-ray in allergic asthmatic patients with rhinitis. Methods. Patients underwent PS radiography in the frontal and mentonian positions and low-dose CT consisting of six to eight coronal scans performed on the central region of the sphenoidal, ethmoidal, maxillary, and frontal sinuses. Possible results for each sinus were a normal aspect or the presence of mucosal thickening, opacification, and/or air-fluid level. Results. Eighty-five (93.4%) of 91 study patients had radiological changes on radiography or CT. In only six (6.6%) were both tests normal. The maxillary was the most involved sinus by both methods. Simultaneous PS abnormalities were observed in 40.5% on X-ray and 56.7% on CT. For the frontal, ethmoidal, and sphenoidal sinuses, the proportion of normal results differed significantly between X-ray and CT: 80.2% versus 89%, 76.9% versus 63.7% and 96.7% versus 70.3%, respectively (p <.05). Agreement was over 70% for the maxillary and frontal sinuses. CT also provided a better diagnosis of air-fluid level changes than X-ray. Conclusions. Low-dose CT significantly showed larger number of normal PS results and diagnosed more severe PS lesions. As the determination of true sinus severity lesion impacts in asthma control, low-dose CT may replace PS plain X-ray and conventional CT to support better clinical decisions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nude rats bearing melanomas on their hindlimbs were treated by isolated limb infusion (ILI) with increasing doses (7.5-400 mug/ml) of melphalan. The response of tumours to treatment at the end of the observation period was graded, according to diameter, as complete response (CR), partial response (PR), no change (NC) or progressive disease (PD). No linear relationship between the dose of melphalan and the tumour response was observed. All doses above a threshold of 15 mug/ml achieved a PR or CR. The achievement of CR was not related to increased dose. Two major implications arise from this work. Firstly, the typically two-to three-fold increase in cytotoxic drug concentration given in high dose chemotherapy compared with standard drug concentration may not be sufficient to produce the expected increase in tumour response and possibly survival, and the controversial results of high dose chemotherapy in different studies may thus be explained. Secondly, since an increase in melphalan dose above a certain threshold does not greatly increase tumour response, the use of combination therapies would seem to be more likely to be effective than increased chemotherapeutic drug doses in achieving better tumour responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectivo do estudo - Investigar se os fatores standard de aquisição de radiografias às órbitas estão otimizados para a deteção de corpos estranhos ferromagnéticos intraoculares em pacientes que irão ser submetidos a ressonâncias magnéticas.