964 resultados para Solar thermal panels


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

90.00% 90.00%

Publicador:

Resumo:

[EN]A numerical model for the evaluation of solar radiation in different locations is presented. The solar radiation model is implemented taking into account the terrain surface using two-dimensional adaptive meshes of triangles that are constructed using a refinement/derefinement procedure in accordance with the variations of terrain surface and albedo. The selected methodology defines the terrain characteristics with a minimum number of points so that the computational cost is reduced for a given accuracy. The model can be used in atmospheric sciences as well as in other fields such as electrical engineering, since it allows the user to find the optimal location for maximum power generation in photovoltaic or solar thermal power plants...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Photovoltaic (PV) solar panels generally produce electricity in the 6% to 16% efficiency range, the rest being dissipated in thermal losses. To recover this amount, hybrid photovoltaic thermal systems (PVT) have been devised. These are devices that simultaneously convert solar energy into electricity and heat. It is thus interesting to study the PVT system globally from different point of views in order to evaluate advantages and disadvantages of this technology and its possible uses. In particular in Chapter II, the development of the PVT absorber numerical optimization by a genetic algorithm has been carried out analyzing different internal channel profiles in order to find a right compromise between performance and technical and economical feasibility. Therefore in Chapter III ,thanks to a mobile structure built into the university lab, it has been compared experimentally electrical and thermal output power from PVT panels with separated photovoltaic and solar thermal productions. Collecting a lot of experimental data based on different seasonal conditions (ambient temperature,irradiation, wind...),the aim of this mobile structure has been to evaluate average both thermal and electrical increasing and decreasing efficiency values obtained respect to separate productions through the year. In Chapter IV , new PVT and solar thermal equation based models in steady state conditions have been developed by software Dymola that uses Modelica language. This permits ,in a simplified way respect to previous system modelling softwares, to model and evaluate different concepts about PVT panel regarding its structure before prototyping and measuring it. Chapter V concerns instead the definition of PVT boundary conditions into a HVAC system . This was made trough year simulations by software Polysun in order to finally assess the best solar assisted integrated structure thanks to F_save(solar saving energy)factor. Finally, Chapter VI presents the conclusion and the perspectives of this PhD work.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The European strategies on energy have been searching for years to reduce the dependency of Europe from fossil fuels. Underlying this effort, there exist geopolitical, economic, environmental reasons and the reality that oil reservoirs will dry out some day. Renewable energies have become a milestone of this strategy because their huge potential has emerged after years of uncertainty. One of the better developed renewable sources, which is nearer to commercial maturity is solar-thermal energy. In this paper, the current state of this technology will be described as well as the developments that may be expected in the short and mid terms, including the thermoelectric solar megaproject DESERTEC, a German proposal to ensure energy resources to the mayor areas of the EU-MENA countries. The reader will acquire a picture of the current state of the market, of the technical challenges already achieved and of the remaining ones.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Solar thermal power plants are usually installed in locations with high yearly average solar radiation, often deserts. In such conditions, cooling water required for thermodynamic cycles is rarely available. Moreover, when solar radiation is high, ambient temperature is very high as well; this leads to excessive condensation temperature, especially when air-condensers are used, and decreases the plant efficiency. However, temperature variation in deserts is often very high, which drives to relatively low temperatures during the night. This fact can be exploited with the use of a closed cooling system, so that the coolant (water) is chilled during the night and store. Chilled water is then used during peak temperature hours to cool the condenser (dry cooling), thus enhancing power output and efficiency. The present work analyzes the performance improvement achieved by night thermal cool storage, compared to its equivalent air cooled power plant. Dry cooling is proved to be energy-effective for moderately high day–night temperature differences (20 °C), often found in desert locations. The storage volume requirement for different power plant efficiencies has also been studied, resulting on an asymptotic tendency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze commercial solar panel performance (i.e., the current-voltage–I-V–curve) at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer’s datasheet.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze the performance (i.e., the I - V curve) of a commercial solar panel at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer's datasheet.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Parabolic reflectors, also known as parabolic troughs, are widely used in solar thermal power plants. This kind of power plants is usually located on desert climates, where the combined action of wind and dust can be of paramount importance. In some cases it becomes necessary to protect these devices from the joined wind and sand action, which is normally accomplished through solid windbreaks. In this paper the results of a wind tunnel test campaign, of a scale parabolic trough row having different windward windbreaks, are reported. The windbreaks herein considered consist of a solid wall with an upper porous fence. Different geometrical configurations, varying the solid wall height and the separation between the parabolic trough row and the windbreak have been considered. From the measured time series, both the mean and peak values of the aerodynamic loads were determined. As it would be expected, mean aerodynamic drag, as well as peak values, decrease as the distance between the windbreak and the parabolic increases, and after a threshold value, such drag loads increase with the distance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La perdiz roja es la especie cinegética por excelencia en la península ibérica, cuya cría en cautividad y suelta controlada comenzó a regularse en los años 70 con la aparición del ICONA. La incubación controlada de huevos de perdiz es imprescindible, con fines cinegéticos y de preservación de la especie, y se desarrolla con incubadoras comerciales de pequeña y mediana escala, distribuidas en zonas rurales con acceso limitado y/o deficiente al suministro eléctrico. En nuestras latitudes el aporte de energía solar térmica se perfila como una posibilidad de mejorar la eficiencia energética de éstas y otras instalaciones y de reducir la dependencia energética exterior. Hay diversos factores físico-químicos que influyen en la calidad de la incubación: temperatura, humedad relativa, y concentración de gases, de los cuales sólo los dos primeros son habitualmente supervisados y controlados en este tipo de incubadoras. Esta Tesis surge en el marco de dos proyectos de cooperación con la AECID, y tiene como objetivos: la caracterización espacial de variables relevantes (temperatura (T), humedad relativa (HR)) en la incubadora comercial durante el proceso de incubación, la determinación de la relación existente entre la evolución de variables ambientales durante el proceso de incubación y la tasa de nacimientos (35-77%), así como el diseño y evaluación del sistema de apoyo solar térmico para determinar su potencial de utilización durante las incubaciones comerciales. La instalación de un número limitado de sensores permite la monitorización precisa del proceso de incubación de los huevos. Los resultados más relevantes indican que en incubaciones comerciales los gradientes de T y HR han sido despreciables (1ºC de diferencia entre las posiciones con mayor y menor T media y un 4,5% de diferencia entre las posiciones con mayor y menor HR), mientras que el seguimiento y ajuste (mediante modelos de crecimiento) de la concentración de CO2 (r2 entre 0,948 y 0,987 en las 5 incubaciones, para un total de 43315 huevos) permite valorar la actividad fisiológica de los huevos e incluso predecir la tasa de éxito (nacimientos), basándose en la concentración de CO2 estimada mediante modelos de crecimiento en el día 20 de incubación (r2 entre 0,997 y 0,994 según el modelo de estimación empleado). El sistema ha sido valorado muy positivamente por los productores (Finca Cinegética Dehesa Vieja de Galapagar). El aporte térmico se ha diseñado (con mínima intrusión en el sistema comercial) sobre la base de un sistema de enfriamiento de emergencia original de la incubadora, al que se han incorporado un colector solar, un depósito, un sistema de electroválvulas, una bomba de circulación y sensores de T en distintos puntos del sistema, y cuyo control ha sido automatizado. En esta Tesis se muestra que la contribución solar puede aportar hasta un 42% de las demandas de energía en nuestras condiciones geográficas para una temperatura de consigna dentro de la incubadora de 36.8ºC, sin afectar a la estabilidad de la temperatura. Además, el rendimiento del colector solar se ha acotado entre un 44% y un 85%, de acuerdo con los cálculos termodinámicos; valores que se mantienen dentro del rango aportado por el fabricante (61%). En el futuro se plantea evaluar el efecto de distintas estrategias de control, tales como controladores difusos, que incorporan el conocimiento experto al control automático. ABSTRACT The partridge is the quintessential game species in the Iberian Peninsula, which controlled breeding and release, began to be regulated in the 70s with the emergence of ICONA. The controlled incubation of eggs is essential, and takes place in commercial incubators of small and medium scale, distributed in rural areas with limited and/or inadequate access to power. In our latitudes the contribution of solar thermal energy is emerging as a possibility to improve the energy efficiency of the facilities and to reduce external energy dependence. There are various physicochemical factors influencing the quality of incubation: temperature, relative humidity and concentration of gases, of which only the first two are typically monitored and controlled in such incubators. This PhD comes within the framework of two cooperation projects with AECID and aims: the spatial characterization of relevant variables in a commercial incubator (temperature (T), and relative humidity (HR)), determining the relationships in the changes in environmental variables during incubation and birth rates (35-77%) as well as the design and evaluation of solar thermal support system to determine its potential use during commercial incubations; the installation of a limited number of sensors has allowed accurate monitoring of incubation of eggs. The most relevant results indicate that in commercial incubations, the gradients in T and HR have been negligible (1°C difference between the highest and lowest positions T and average 4.5% difference between the highest and lowest positions HR), while monitoring and fit using growth models of the concentration of CO2 (r2 between 0.948 and 0.987 in 5 incubations, for a total amount of 43,315 eggs) allows assessing the physiological activity of the eggs and even predict the success rate (hatchability), based on the estimated concentration of CO2 by using growth models on day 20 of incubation (r2 between 0.997 and 0.994 depending on the fit model).The system has been highly valued by producers (Finca Cinegética Dehesa Vieja de Galapagar). The hybrid heat system is designed (with minimal intrusion into the commercial system) based on an emergency cooling device, original in the incubator. New elements have been incorporated: a solar collector, a tank, a system of solenoid valves, a circulating pump and T sensors at various points of the system, whose control has been automated. This PhD shows that the solar contribution is responsible for up to 42% of energy demands in our geographical conditions for a setpoint temperature inside the incubator of 36.8ºC, without questioning the stability of the temperature. Furthermore, the efficiency of the solar collector has been bounded between 44% and 85%, according to thermodynamic calculations; values remain within the range provided by the manufacturer (61%). In the future it is proposed to evaluate the effect of different control strategies, such as fuzzy controllers, which incorporate the expertise to automated control.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

"August 1979

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We assess the feasibility of hybrid solar-biomass power plants for use in India in various applications including tri-generation, electricity generation and process heat. To cover this breadth of scenarios we analyse, with the help of simulation models, case studies with peak thermal capacities ranging from 2 to 10 MW. Evaluations are made against technical, financial and environmental criteria. Suitable solar multiples, based on the trade-offs among the various criteria, range from 1 to 2.5. Compared to conventional energy sources, levelised energy costs are high - but competitive in comparison to other renewables such as photovoltaic and wind. Long payback periods for hybrid plants mean that they cannot compete directly with biomass-only systems. However, a 1.2-3.2 times increase in feedstock price will result in hybrid systems becoming cost competitive. Furthermore, in comparison to biomass-only, hybrid operation saves up to 29% biomass and land with an 8.3-24.8 $/GJ/a and 1.8-5.2 ¢/kWh increase in cost per exergy loss and levelised energy cost. Hybrid plants will become an increasingly attractive option as the cost of solar thermal falls and feedstock, fossil fuel and land prices continue to rise. In the foreseeable future, solar will continue to rely on subsidies and it is recommended to subsidise preferentially tri-generation plants. © 2012 Elsevier Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Desalination of groundwater is essential in many arid areas that are far from both seawater and fresh water resources. The ideal groundwater desalination system should operate using a sustainable energy source and provide high water output per land area and cost. To avoid discharging voluminous brine, it should also provide high recovery. To achieve these aims, we have designed DesaLink, a novel approach to linking the solar Rankine cycle to reverse osmosis (RO). To achieve high recovery without the need for multiple RO stages, DesaLink adopts a batch mode of operation. It is suited to use with a variety of solar thermal collectors including linear Fresnel reflectors (LFR). For example, using a LFR occupying 1,000m of land and providing steam at 200°C and 15.5 bar, DesaLink is predicted to provide 350m of fresh water per day at a recovery ratio of 0.7, when fed with brackish groundwater containing 5,000ppm of sodium chloride. Here, we report preliminary experiments to assess the feasibility of the concept. We study the effects of longitudinal dispersion, concentration polarisation and describe a pilot experiment to demonstrate the batch process using a materials testing machine. In addition, we demonstrate a prototype of DesaLink running from compressed air to simulate steam.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Energy security is a major concern for India and many rural areas remain un-electrified. Thus, innovations in sustainable technologies to provide energy services are required. Biomass and solar energy in particular are resources that are widely available and underutilised in India. This paper aims to provide an overview of a methodology that was developed for designing and assessing the feasibility of a hybrid solar-biomass power plant in Gujarat. Design/methodology/approach: The methodology described is a combination of engineering and business management studies used to evaluate and design solar thermal collectors for specific applications and locations. For the scenario of a hybrid plant, the methodology involved: the analytical hierarchy process, for solar thermal technology selection; a cost-exergy approach, for design optimisation; quality function deployment, for designing and evaluating a novel collector - termed the elevation linear Fresnel reflector (ELFR); and case study simulations, for analysing alternative hybrid plant configurations. Findings: The paper recommended that for a hybrid plant in Gujarat, a linear Fresnel reflector of 14,000 m2 aperture is integrated with a 3 tonne per hour biomass boiler, generating 815 MWh per annum of electricity for nearby villages and 12,450 tonnes of ice per annum for local fisheries and food industries. However, at the expense of a 0.3 ¢/kWh increase in levelised energy costs, the ELFR can increase savings of biomass (100 t/a) and land (9 ha/a). Research limitations/implications: The research reviewed in this paper is primarily theoretical and further work will need to be undertaken to specify plant details such as piping layout, pump sizing and structure, and assess plant performance during real operational conditions. Originality/value: The paper considers the methodology adopted proved to be a powerful tool for integrating technology selection, optimisation, design and evaluation and promotes interdisciplinary methods for improving sustainable engineering design and energy management. © Emerald Group Publishing Limited.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Liquid desiccant cooling systems (LDCS) are energy efficient means of providing cooling, especially when powered by low-grade thermal sources. In this paper, the underlying principles of operation of desiccant cooling systems are examined, and the main components (dehumidifier, evaporative cooler and regenerator) of the LDCS are reviewed. The evaporative cooler can take the form of direct, indirect or semi-indirect. Relative to the direct type, the indirect type is generally less effective. Nonetheless, a certain variant of the indirect type - namely dew-point evaporative cooler - is found to be the most effective amongst all. The dehumidifier and the regenerator can be of the same type of equipment: packed tower and falling film are popular choices, especially when fitted with an internal heat exchanger. The energy requirement of the regenerator can be supplied from solar thermal collectors, of which a solar pond is an interesting option especially when a large scale or storage capability is desired.