970 resultados para Solar heating


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This chapter covers the basic concepts of passive building design and its relevant strategies, including passive solar heating, shading, natural ventilation, daylighting and thermal mass. In environments with high seasonal peak temperatures and/or humidity (e.g. cities in temperate regions experiencing the Urban Heat Island effect), wholly passive measures may need to be supplemented with low and zero carbon technologies (LZCs). The chapter also includes three case studies: one residential, one demonstrational and one academic facility (that includes an innovative passive downdraught cooling (PDC) strategy) to illustrate a selection of passive measures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Many factors, both mesoscale and larger scale, often come together in order for a particular convective initiation to take place. The authors describe a modeling study of a case from the Convective Storms Initiation Project (CSIP) in which a single thunderstorm formed behind a front in the southern United Kingdom. The key features of the case were a tongue of low-level high θw air associated with a forward-sloping split front (overrunning lower θw air above), a convergence line, and a “lid” of high static stability air, which the shower was initially constrained below but later broke through. In this paper, the authors analyze the initiation of the storm, which can be traced back to a region of high ground (Dartmoor) at around 0700 UTC, in more detail using model sensitivity studies with the Met Office Unified Model (MetUM). It is established that the convergence line was initially caused by roughness effects but had a significant thermal component later. Dartmoor had a key role in the development of the thunderstorm. A period of asymmetric flow over the high ground, with stronger low-level descent in the lee, led to a hole in a layer of low-level clouds downstream. The surface solar heating through this hole, in combination with the tongue of low-level high θw air associated with the front, caused the shower to initiate with sufficient lifting to enable it later to break through the lid.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Canadian Middle Atmosphere Model (CMAM) has been used to examine the middle atmosphere response to CO2 doubling. The radiative-photochemical response induced by doubling CO2 alone and the response produced by changes in prescribed SSTs are found to be approximately additive, with the former effect dominating throughout the middle atmosphere. The paper discusses the overall response, with emphasis on the effects of SST changes, which allow a tropospheric response to the CO2 forcing. The overall response is a cooling of the middle atmosphere accompanied by significant increases in the ozone and water vapor abundances. The ozone radiative feedback occurs through both an increase in solar heating and a decrease in infrared cooling, with the latter accounting for up to 15% of the total effect. Changes in global mean water vapor cooling are negligible above ~30 hPa. Near the polar summer mesopause, the temperature response is weak and not statistically significant. The main effects of SST changes are a warmer troposphere, a warmer and higher tropopause, cell-like structures of heating and cooling at low and middlelatitudes in the middle atmosphere, warming in the summer mesosphere, water vapor increase throughout the domain, and O3 decrease in the lower tropical stratosphere. No noticeable change in upwardpropagating planetary wave activity in the extratropical winter–spring stratosphere and no significant temperature response in the polar winter–spring stratosphere have been detected. Increased upwelling in the tropical stratosphere has been found to be linked to changed wave driving at low latitudes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Sweden, 90% of the solar heating systems are solar domestic hot water and heating systems (SDHW&H), so called combisystems. These generally supply most of the domestic hot water needs during the summer and have enough capacity to supply some energy to the heating system during spring and autumn. This paper describes a standard Swedish combisystem and how the output from it varies with heating load, climate within Sweden, and how it can be increased with improved system design. A base case is defined using the standard combi- system, a modern Swedish single family house and the climate of Stockholm. Using the simulation program Trnsys, parametric studies have been performed on the base case and improved system designs. The solar fraction could be increased from 17.1% for the base case to 22.6% for the best system design, given the same system size, collector type and load. A short analysis of the costs of changed system design is given, showing that payback times for additional investment are from 5-8 years. Measurements on system components in the laboratory have been used to verify the simulation models used. More work is being carried out in order to find even better system designs, and further improvements in system performance are expected.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Del 1:Innehållsförteckning och korta sammanfattningarDEL 2:Verksamhetsberättelsen för perioden maj 1992 till april 1993 beskriver de arbeten som har gjorts av villasolvärmegruppen på SERC efter den inledande studie (SERC/UCFB-91/0039), där villasolvärmesystem kartlades. Följande arbeten beskrivs:- Utveckling av lågflödessystem och internationella kontakter- Uppbyggnad av värmelaboratorium på SERC- Praktiska test av värmelagringsenheten- Praktiska test av nya systemkomponenter i solvärmekretsen- Datasimulering inkluderande nyutvecklade systemkomponenterI verksamhetsplanen beskrivs huvudmålet för de arbeten som ska utföras under trårsperioden 93 - 96. Mera detaljerat beskrivs de arbeten som ska utföras under budgetåret 1993/94:- Beräkningsprogram för nogrannare dimensionering av finrörsvärmeväxlare- Konstruktion av maskiner för värmeväxlartillverkning- Utveckling av värmeväxlare för tappvarmvatten- Simuleringsberäkningar för hela systemet med PRESIM/TRNSYS.DEL 3:Del 3 innehåller en redovisning av mätresultat för den undersökta kombitanken. Temperaturförloppen på olika höjd i tankens har studerats vid uppvärmning genom solvärmeväxlaren och nedkylning genom tappning av varmvatten. Resultaten diskuteras kvalitativt och redovisas kvantitativt i form av diagram. Mätresultaten på två prototyper av den på SERC utvecklade finrörsvärmeväxlaren redovisas och diskuteras i jämförelse till traditionell värmeväxlare. De erhållna mätresultaten används som ingångsvärden för simuleringsberäkningar med PRESIM/TRNSYS. Problemen med de i PRESIM/TRNSYS befintliga modellerna diskuteras. De utförda modellberäkningarna tillåter en uppskattning av möjliga förbättringar i form av höjd årsverkningsgrad för ett svenskt villasolvärmesystem med kombitank. I del 3 redovisas dessutom de mätningar som har utförts på otika pumpar vilka skulle kunna användas i solfångarkretsen. Sex olika pumpar analyseras och diskuteras. Del 3 har följande rubriker:- Beskrivning av den undersökta lagringstanken- Mätningar på tappvarmvattenväxlare- Mätningar på solvärmeväxlare (kamflänsrör och finrörsvärmeväxlare)- Simuleringsberäkningar- PumpmätningarDEL 4:Del 4 innehåller publicerade rapporter under 1992 och 93 samt patentansökan för SERC?s finrörsvärmeväxlare: - NORTH SUN 1992, Solar Energy at High Latitudes, June 24-26 1992 Trondheim, Norway. Domestic solar heating system - a systematic study i progress Patentansökan på finrorsvärmeväxlare till Patent- och Registreringsverket från 93 01 23. ISES SOLAR WORLD CONGRESS, 23-27 augusti 1993, Budapest, HUNGARY Criteria for cost efficient small scale solar hot water installations.DEL 5:Del 5 hänvisar till rapporterna från IEA Task-1 4 mötena om solfångarsystem i- Hameln, Tyskland, augusti 1992 och- Rom, Italien, januari 1993.I rapporterna beskrivs aktiviteten inom den internationella arbetsgruppen speciellt med hänsyn på utveckling av villasolvärmesystem. I Rom presenterades principlösningen för den på SERC utvecklade finrörsvärmeväxlare. De har publicerats separat som nr 42 och 46 i SERCs rapportserie.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Test method for integrated solar- biomass systems - Long term prediction trough short term measurementsSP Technical Research Institute of Sweden and SERC, Dalarna University have in cooperation developed a test method for integrated solar and biomass systems. The test method is performed under six days including two summer days, two winter days and two spring/autumn days true to real weather conditions and loads for a single family house. The aim of the test method is to get information about a Combisystem’s annual performance and operation throughout a short term test. Seven different solar Combisystems have been tested within the project together with a pellet boiler without solar collectors. In addition to that a comparative testing has been performed at the two laboratories at SP and at SERC on the same Combisystem. The test method developed within the project has been proved to withstand the aim of the project, which is to be able to compare the performance between the systems. The test method is also suitable for identification of possible operation problems so they can be taken care of and consequently improves the system.The project and the system testing reveal that it is in general favorable to combine biomass pellets with solar heating. Pellet boilers has normally a low performance during the summer period but combined with a solar collector the boiler can be switch off during this period. There are however big differences in performance between the tested. The efficiency of the pellet boiler is highly dependent of the operating conditions and elements like heat losses from the system, system configuration and control strategy have great influence of the performance of the system and the emissions. On the other hand, the performance and the size of the solar collectors have a minor effect on the overall system performance. There is obviously a big potential for improvement of the system´s performance and the developed test method is an essential way to implement this perfection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate how electricallyheated houses can be converted to using wood pellet and solarheating. There are a large number of wood pellet stoves on themarket. Many stoves have a water jacket, which gives anopportunity to distribute the heat to domestic hot water and aradiator heating system. Three typical Swedish houses with electric resistanceheating have been studied. Fourteen different system conceptsusing wood pellet stoves and solar heating systems have beenevaluated. The systems and the houses have been simulated indetail using TRNSYS. The houses have been divided in up to 10different zones and heat transfer by air circulation throughdoorways and open doors have been simulated. The pellet stoveswere simulated using a recently developed TRNSYS component,which models the start- and stop phases, emissions and thedynamic behaviour of the stoves. The model also calculates theCO-emissions. Simulations were made with one stove without awater jacket and two stoves with different fractions of thegenerated heat distributed in the water circuit. Simulations show that the electricity savings using a pelletstove are greatly affected by the house plan, the systemchoice, if the internal doors are open or closed and thedesired level of comfort. Installing a stove with awater-jacket connected to a radiator system and a hot waterstorage has the advantage that heat can be transferred todomestic hot water and be distributed to other rooms. Suchsystems lead to greater electricity savings, especially inhouses having a traditional layout. It was found that not allrooms needed radiators and that it was more effective in mostcases t use a stove with a higher fraction of the heatdistributed by the water circuit. The economic investigation shows that installing a woodpellet stove without a water jacket gives the lowest totalenergy- and capital costs in the house with an open plan (fortoday's energy prices and the simulated comfort criteria). Inthe houses with a traditional layout a pellet stove givesslightly higher costs than the reference house having onlyelectrical resistance heating due to the fact that less heatingcan be replaced. The concepts including stoves with a waterjacket all give higher costs than the reference system, but theconcept closest to be economical is a system with a bufferstore, a stove with a high fraction of the heat distributed bythe water circuit, a new water radiator heating system and asolar collector. Losses from stoves can be divided into: flue gas lossesincluding leakage air flow when the stove is not in operation;losses during start and stop phases; and losses due to a highair factor. An increased efficiency of the stoves is importantboth from a private economical point of view, but also from theperspective that there can be a lack of bio fuel in the nearfuture also in Sweden. From this point of view it is alsoimportant to utilize as much solar heat as possible. Theutilization of solar heat is low in the simulated systems,depending on the lack of space for a large buffer store. The simulations have shown that the annual efficiency ismuch lower that the nominal efficiency at full power. Thesimulations have also shown that changing the control principlefor the stove can improve efficiency and reduce theCO-emissions. Today's most common control principle for stovesis the on/off control, which results in many starts and stopsand thereby high CO-emissions. A more advanced control varyingthe heating rate from maximum to minimum to keep a constantroom temperature reduces the number of starts and stops andthereby the emissions. Also the efficiency can be higher withsuch a control, and the room temperature will be kept at a moreconstant temperature providing a higher comfort.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A practical experiment is described which was used to help university students increase their understanding of the effect of construction methods and window design on passive solar heating and electrical heating. A number of one tenth scale model rooms were constructed by students and sited out-of-doors in the late autumn. The models were fabricated to mimic available commercial construction techniques with careful consideration being given to window size and placement for solar access. Each model had a thermostatically controlled electric heating element. The temperatures and electricity use of the models were recorded using data-loggers over a two week period. The performances of the models based on energy consumption and internal temperature were compared with each other and with predictions based upon thermal mass and R-values. Examples of questions used by students to facilitate this process are included. The effect of scaling on thermal properties was analysed using Buckingham’s p-theorem.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Typical Meteorological Year (TMY) data is used extensively in building energy simulations and solar energy analysis. TMY data for New Zealand, however, is relatively limited and no such data existed for Hamilton. Ten years of hourly meteorological data was analysed, and a TMY was developed. Simulations using the TMY data were conducted to determine the performance of a solar pool-heating system. It was found that the TMY was able to predict the annual performance of this system to within 2% of the long-term mean. It is intended that this TMY could be used to perform simulations on building energy use and solar heating systems in Hamilton.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A solar alternative system for water heating is presented. It work on a thermosiphon, consisting of one or two alternative collectors and a water storage tank also alternative, whose main purpose is to socialize the use of energy mainly to be used by people of low income. The collectors were built from the use of pets bottles, cans of beer and soft drinks and tubes of PVC, ½ " and the thermal reservoirs from a drum of polyethylene used for storage of water and garbage placed inside cylinder of fiber glass and EPS ground between the two surfaces. Such collectors are formed by three elements: pet bottles, cans and tubes absorbers. The heating units, which form the collector contains inside the cans that can be closed, in original form or in the form of plate. The collectors have an absorber grid formed by eight absorbers PVC tube, connected through connections at T of the same material and diameter. It will be presented data of the thermal parameters which demonstrate the efficiency of the heating system proposed. Relative aspects will be boarded also the susceptibility the thermal degradation and for UV for the PVC tubes. It will be demonstrated that this alternative heating system, which has as its main feature low cost, presents thermal, economic and materials viabilities

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radar and satellite data from the Tropical Rainfall Measuring Mission-Large-Scale Biosphere-Atmosphere (TRMM-LBA) project have been examined to determine causes for convective storm initiation in the southwest Amazon region. The locations and times of storm initiation were based on the National Center for Atmospheric Research (NCAR) S-band dual-polarization Doppler radar (S-Pol). Both the radar and the Geostationary Operational Environmental Satellite-8 (GOES-8) visible data were used to identify cold pools produced by convective precipitation. These data along with high-resolution topographic data were used to determine possible convective storm triggering mechanisms. The terrain elevation varied from 100 to 600 m. Tropical forests cover the area with numerous clear-cut areas used for cattle grazing and farming. This paper presents the results from 5 February 1999. A total of 315 storms were initiated within 130 km of the S-Pol radar. This day was classified as a weak monsoon regime where convection developed in response to the diurnal cycle of solar heating. Scattered shallow cumulus during the morning developed into deep convection by early afternoon. Storm initiation began about 1100 LST and peaked around 1500-1600 LST. The causes of storm initiation were classified into four categories. The most common initiation mechanism was caused by forced lifting by a gust front (GF; 36%). Forcing by terrain (>300 m) without any other triggering mechanism accounted for 21% of the initiations and colliding GFs accounted for 16%. For the remaining 27% a triggering mechanism was not identified. Examination of all days during TRMM-LBA showed that this one detailed study day was representative of many days. A conceptual model of storm initiation and evolution is presented. The results of this study should have implications for other locations when synoptic-scale forcing mechanisms are at a minimum. These results should also have implications for very short-period forecasting techniques in any location where terrain, GFs, and colliding boundaries influence storm evolution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)