905 resultados para Solar collector model condensation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes:  • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results.   The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are:  • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions.   The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab.   This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a study of the absorption refrigeration system and the modeling and evaluation of two cycles using the binary solutions water-lithium bromide and ammonia-water for an equipment to be used in small size plants like residences. The study and evaluation aims the complete understanding of all parts of the system and the influence of each one of them as well as the spread of the knowledge to raise the use of this type of equipment in all sizes in order to decrease the energetic consumption of plants of all scales and making viable the alternative sources. The study is done in each element of the cycle separately and in some auxiliary equipments required in the operation such as the main power source, the solar collector. The software used for modeling, with emphasis on thermal part, was the EES (Engineering Equation Solver), that permitted the thermal balance calculus and acquisition of the used fluids properties. The results obtained for the equipment shows the system is more complex than the widely used in business, however, it can be viable and represents an alternative to increase the energetic efficiency

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Questa tesi di dottorato tratta il tema delle Tecnologie Appropriate e delle Buone Pratiche per la gestione delle risorse idriche ed il risparmio energetico nell’ambito dell’abitato urbano e rurale. Viene fatta una breve panoramica sulle principali teorie e metodologie che fino ad oggi hanno fatto da linee guida per la progettazione sostenibile e il corretto utilizzo delle risorse. Questa visione d'insieme servirà per esprimere delle valutazioni e trovare dei comuni dominatori per proporre una nuova metodologia d'approccio alla gestione delle risorse con particolare attenzione rivolta alla condizione presente e alla zona d’intervento. Site specific sustainability Approach (S3A). I casi studio: • Un progetto di approvvigionamento idrico e di desalinizzazione delle acque per un’oasi del Sahara marocchino. • Un progetto di ricerca della Columbia University e della NASA legato alla sostenibilità urbana di New York che analizza i benefici apportati dall'installazione di coperture verdi nell'area di Manhattan da un punto di vista della gestione delle risorse idriche, energetiche e delle componenti ambientali. • Un progetto di verde verticale e giardino pensile a Milano. • Un progetto di approvvigionamento idrico sostenibile e gestione del verde per la città di Porto Plata in Repubblica Domenicana. Approfondimenti e sperimentazioni. • E’ stato approfondito il tema della distillazione solare per la dissalazione e potabilizzazione delle acque in zone rurali desertiche ed isolate. • E’ stato progettato e realizzato un prototipo innovativo di distillatore tubolare con collettore solare parabolico. Il prototipo è stato testato nei laboratori della Columbia University di New York. • Sono state approfondite le Khettaras o Qanat, tunnel sotterranei per l’approvvigionamento idrico nelle zone aride. • Infine sono stati approfonditi i benefici apportati dalle coperture a verde (tetti verdi) e dal verde verticale nelle zone urbane dal punto di vista della gestione delle risorse idriche ed il risparmio energetico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several authors have analysed the changes of the probability density function of the solar radiation with different time resolutions. Some others have approached to study the significance of these changes when produced energy calculations are attempted. We have undertaken different transformations to four Spanish databases in order to clarify the interrelationship between radiation models and produced energy estimations. Our contribution is straightforward: the complexity of a solar radiation model needed for yearly energy calculations, is very low. Twelve values of monthly mean of solar radiation are enough to estimate energy with errors below 3%. Time resolutions better than hourly samples do not improve significantly the result of energy estimations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En este escrito se pretende llevar a cabo la realización de un proyecto técnico sobre eficiencia energética en edificios. El proyecto comienza con el estudio de la demanda térmica de un edificio, es decir, de sus necesidades de calefacción, refrigeración y agua caliente sanitaria (ACS). Una vez realizado este análisis, se procede al estudio de distintas alternativas para la disminución del coste asociado al consumo energético del edificio, las cuales son: mejora del aislamiento de la envolvente térmica del edificio, instalación de colectores solares para la producción de ACS y el cambio de los quemadores de las calderas. De estas medidas se han presupuestado aquellas que poseen un bajo periodo de retorno de la inversión, y se ha desarrollado su planificación, programación temporal y análisis económico. ABSTRACT In this document is pretended to be carry out the performance of a technical project about energy efficiency in buildings. The project begins with the study of the thermal demand of the building, that is to say, the heating, cooling and domestic hot water (DHW) needs. Once the analysis has been done, is proceeded the study of different alternatives for diminishing the cost associate to the building energy consumption, which are: improvement of the insulation of the building, solar collector installation to produce DHW and change of the burner of the boilers. Among this measures, has been budgeted the ones that possess a low invest pay-back, and it is been developed their planning, their temporal programming and their economic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anew, simple, and quick-calculationmethodology to obtain a solar panel model, based on the manufacturers’ datasheet, to perform MPPT simulations, is described. The method takes into account variations on the ambient conditions (sun irradiation and solar cells temperature) and allows fast MPPT methods comparison or their performance prediction when applied to a particular solar panel. The feasibility of the described methodology is checked with four different MPPT methods applied to a commercial solar panel, within a day, and under realistic ambient conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El siguiente proyecto lleva a cabo un estudio sobre la eficiencia energética en una vivienda unifamiliar basándose en la legislación actual europea y española. Para empezar se obtendrá la calificación energética del inmueble mediante el programa informático de la opción simplificada CE3X. A continuación se proporcionará un estudio con las medidas de mejora más adecuadas para mejorar la eficiencia energética de la vivienda, las medidas que se llevarán a cabo serán: la mejora de la envolvente térmica, mejorando el aislamiento de la fachada y la sustitución de ventanas, la instalación de una caldera de biomasa y la instalación de un sistema de colectores solares para cubrir la demanda de calefacción y ACS. Para finalizar se realiza un presupuesto de las medidas de mejoras propuestas, así como un análisis económico y una planificación y programación temporal. ABSTRACT The object of this Project is to carry out a study on the energy efficiency of a single family home in accordance with the present European and Spanish legislation. The first step is to obtain the home energy efficiency by means of a CE3X computer program. The second step is a study with the most appropriate improvement measures is provided in order to improve the home energy efficiency. The measures to be carried out will be as follows: improving the heat insulation, as well as, the facade heat insulation and replacing the windows, installing a biomass heating system and a solar collector in order to satisfy the heating and domestic hot water (DHW) demands. Finally a budget with the proposed improvement measures is made as well as a financial analysis and a time planning and programming of the project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper focus on the development of an algorithm using Matlab to generate Typical Meteorological Years from weather data of eight locations in the Madeira Island and to predict the energy generation of photovoltaic systems based on solar cells modelling. Solar cells model includes the effect of ambient temperature and wind speed. The analysis of the PV system performance is carried out through the Weather Corrected Performance Ratio and the PV system yield for the entire island is estimated using spatial interpolation tools.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Double-pass counter flow v-grove collector is considered one of the most efficient solar air-collectors. In this design of the collector, the inlet air initially flows at the top part of the collector and changes direction once it reaches the end of the collector and flows below the collector to the outlet. A mathematical model is developed for this type of collector and simulation is carried out using MATLAB programme. The simulation results were verified with three distinguished research results and it was found that the simulation has the ability to predict the performance of the air collector accurately as proven by the comparison of experimental data with simulation. The difference between the predicted and experimental results is, at maximum, approximately 7% which is within the acceptable limit considering some uncertainties in the input parameter values to allow comparison. A parametric study was performed and it was found that solar radiation, inlet air temperature, flow rate and length has a significant effect on the efficiency of the air collector. Additionally, the results are compared with single flow V-groove collector.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Double-pass counter flow v-grove collector is considered one of the most efficient solar air-collectors. In this design of the collector, the inlet air initially flows at the top part of the collector and changes direction once it reaches the end of the collector and flows below the collector to the outlet. A mathematical model is developed for this type of collector and simulation is carried out using MATLAB programme. The simulation results were verified with three distinguished research results and it was found that the simulation has the ability to predict the performance of the air collector accurately as proven by the comparison of experimental data with simulation. The difference between the predicted and experimental results is, at maximum, approximately 7% which is within the acceptable limit considering some uncertainties in the input parameter values to allow comparison. A parametric study was performed and it was found that solar radiation, inlet air temperature, flow rate and length have a significant effect on the efficiency of the air collector. Additionally, the results are compared with single flow V-groove collector.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Parabolic trough concentrator collector is the most matured, proven and widespread technology for the exploitation of the solar energy on a large scale for middle temperature applications. The assessment of the opportunities and the possibilities of the collector system are relied on its optical performance. A reliable Monte Carlo ray tracing model of a parabolic trough collector is developed by using Zemax software. The optical performance of an ideal collector depends on the solar spectral distribution and the sunshape, and the spectral selectivity of the associated components. Therefore, each step of the model, including the spectral distribution of the solar energy, trough reflectance, glazing anti-reflection coating and the absorber selective coating is explained and verified. Radiation flux distribution around the receiver, and the optical efficiency are two basic aspects of optical simulation are calculated using the model, and verified with widely accepted analytical profile and measured values respectively. Reasonably very good agreement is obtained. Further investigations are carried out to analyse the characteristics of radiation distribution around the receiver tube at different insolation, envelop conditions, and selective coating on the receiver; and the impact of scattered light from the receiver surface on the efficiency. However, the model has the capability to analyse the optical performance at variable sunshape, tracking error, collector imperfections including absorber misalignment with focal line and de-focal effect of the absorber, different rim angles, and geometric concentrations. The current optical model can play a significant role in understanding the optical aspects of a trough collector, and can be employed to extract useful information on the optical performance. In the long run, this optical model will pave the way for the construction of low cost standalone photovoltaic and thermal hybrid collector in Australia for small scale domestic hot water and electricity production.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found. © 2012 The Authors.