727 resultados para Soft contact lenses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Theoretically myopes are required to exert more accommodation and vergence when wearing single vision contact lenses compared to glasses and hypermetropes less. This study aims to quantify the effects clinically. Method: Thirty subjects (21 female, nine male, average age 21.0 ± 2.2 years) with a range of refractive errors (-7.87 D to +3.50 D) viewed in a random order, static targets at 0.1, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 D accommodative demand that were matched for angular subtense. The subjects were fully corrected with spectacles and daily disposable contact lenses to their full prescription. Accommodation was monitored objectively with the PowerRefractor and Shin-Nippon SRW5000 and vergence and pupil size with the PowerRefractor. Results: Myopes exerted greater accommodative effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.35, p = 0.001 PowerRefractor). Myopes also exerted greater vergence effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.22, p < 0.01). Conclusion: Theoretical calculation of the accommodative and vergence requirements with glasses compared to contact lenses reflect clinical findings, although there is reasonable variability between individuals. © 2006 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. This study reports data from an 18-month longitudinal study of neophyte contact lens wearers and compares changes in ocular refraction and biometry induced by daily wear and continuous wear of two different silicone hydrogel (SiH) materials. Methods. Forty-five subjects were enrolled in the study and randomly assigned to wear one of the two silicone hydrogel materials: Lotrafilcon A or Balafilcon A lenses on either a daily or continuous wear basis. Measurements of objective refraction, axial length, anterior chamber depth, corneal curvature, and the rate of peripheral corneal flattening were performed before and 1, 3, 6, 12, and 18 months after initial fitting. Results. Mean spherical equivalent refractive error increased in the myopic direction in all contact lens groups across time (p < 0.001). Axial length was the main biometric contributor to the development of myopia. After 18 months of lens wear, subjects in the Lotrafilcon A group showed the greater mean increase in myopia (i.e., -0.50 D). Conclusions. The results of this study show that increases in myopia, similar if not higher than those found to occur normally in young adult noncontact lens wearers, still occur with silicone hydrogel contact lens wear. The main biometric contributor to the progression of myopia was an increase in axial length. Differences between our results and those of previous studies with silicone hydrogel contact lenses could be attributed to the differing populations used in which both age and occupation may have played a role. Copyright © 2005 American Academy of Optometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The principal theme of this thesis is the identification of additional factors affecting, and consequently to better allow, the prediction of soft contact lens fit. Various models have been put forward in an attempt to predict the parameters that influence soft contact lens fit dynamics; however, the factors that influence variation in soft lens fit are still not fully understood. The investigations in this body of work involved the use of a variety of different imaging techniques to both quantify the anterior ocular topography and assess lens fit. The use of Anterior-Segment Optical Coherence Tomography (AS-OCT) allowed for a more complete characterisation of the cornea and corneoscleral profile (CSP) than either conventional keratometry or videokeratoscopy alone, and for the collection of normative data relating to the CSP for a substantial sample size. The scleral face was identified as being rotationally asymmetric, the mean corneoscleral junction (CSJ) angle being sharpest nasally and becoming progressively flatter at the temporal, inferior and superior limbal junctions. Additionally, 77% of all CSJ angles were within ±50 of 1800, demonstrating an almost tangential extension of the cornea to form the paralimbal sclera. Use of AS-OCT allowed for a more robust determination of corneal diameter than that of white-to-white (WTW) measurement, which is highly variable and dependent on changes in peripheral corneal transparency. Significant differences in ocular topography were found between different ethnicities and sexes, most notably for corneal diameter and corneal sagittal height variables. Lens tightness was found to be significantly correlated with the difference between horizontal CSJ angles (r =+0.40, P =0.0086). Modelling of the CSP data gained allowed for prediction of up to 24% of the variance in contact lens fit; however, it was likely that stronger associations and an increase in the modelled prediction of variance in fit may have occurred had an objective method of lens fit assessment have been made. A subsequent investigation to determine the validity and repeatability of objective contact lens fit assessment using digital video capture showed no significant benefit over subjective evaluation. The technique, however, was employed in the ensuing investigation to show significant changes in lens fit between 8 hours (the longest duration of wear previously examined) and 16 hours, demonstrating that wearing time is an additional factor driving lens fit dynamics. The modelling of data from enhanced videokeratoscopy composite maps alone allowed for up to 77% of the variance in soft contact lens fit, and up to almost 90% to be predicted when used in conjunction with OCT. The investigations provided further insight into the ocular topography and factors affecting soft contact lens fit.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper focuses on the effects of wear regime on the deposition pattern of important immunoregulatory proteins on FDA Group IV etafilcon-A lenses. Specifically, the aim was to assess the extent to which the daily disposable wear modality produces a different deposition of proteins from the conventional daily wear regime which is coupled with cleaning and disinfection. Counter immunoelectrophoresis (CIE) was employed to detect individual proteins in lens extracts from individual patients and focused on the analysis of five proteins, IgA, IgG, lactoferrin, albumin and kininogen. Deposition was monitored as a function of time; significantly lower deposition was detected on the daily disposable lenses. cr 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the performance of four commercially available silicone hydrogel multifocal monthly contact lens designs against monovision. METHODS: A double-masked randomized crossover trial of Air Optix Aqua multifocal, PureVision 2 for Presbyopia, Acuvue OASYS for Presbyopia, Biofinity multifocal, and monovision with Biofinity contact lenses was conducted on 35 presbyopes (54.3 ± 6.2 years). After 4 weeks of wear, visual performance was quantified by high- and low-contrast visual acuity under photopic and mesopic conditions, reading speed, defocus curves, stereopsis, halometry, aberrometry, Near Activity Visual Questionnaire rating, and subjective quality of vision scoring. Bulbar, limbal, and palpebral hyperemia and corneal staining were graded to monitor the impact of each contact lens on ocular physiology. RESULTS: High-contrast photopic visual acuity (p = 0.102), reading speed (F = 1.082, p = 0.368), and aberrometry (F = 0.855, p = 0.493) were not significantly different between presbyopic lens options. Defocus curve profiles (p <0.001), stereopsis (p <0.001), halometry (F = 4.101, p = 0.004), Near Activity Visual Questionnaire (F = 3.730, p = 0.007), quality of vision (p = 0.002), bulbar hyperemia (p = 0.020), and palpebral hyperemia (p = 0.012) differed significantly between lens types, with the Biofinity multifocal lens design principal (center-distance lens was fitted to the dominant eye and a center-near lens to the nondominant eye) typically outperforming the other lenses. CONCLUSIONS: Although ocular aberration variation between individuals largely masks the differences in optics between current multifocal contact lens designs, certain design strategies can outperform monovision, even in early presbyopes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the surface tear breakup time and clinical performance of three daily disposable silicone hydrogel contact lenses over 16 hours of wear. METHODS: Thirty-nine patients (mean [±SD] age, 22.1 [±3.5] years) bilaterally wore (narafilcon A, filcon II-3, and delefilcon A) contact lenses in a prospective, randomized, masked, 1-week crossover clinical trial. Tear film was assessed by the tear meniscus height (TMH), ocular/contact lens surface temperature dynamics, and lens surface noninvasive breakup time at 8, 12, and 16 hours of wear. Clinical performance and ocular physiology were assessed by subjective questionnaire, by high-/low-contrast logMAR (logarithm of the minimum angle of resolution) acuity, and through bulbar and limbal hyperemia grading. Corneal and conjunctival staining were assessed after lens removal. RESULTS: Delefilcon A demonstrated a longer noninvasive breakup time (13.4 [±4.4] seconds) than filcon II-3 (11.6 [±3.7] seconds; p < 0.001) and narafilcon A (12.3 [±3.7] seconds; p < 0.001). A greater TMH (0.35 [±0.11] mm) was shown by delefilcon A than filcon II-3 (0.32 [±0.10] seconds; p = 0.016). Delefilcon A showed less corneal staining after 16 hours of lens wear (0.7 [±0.6] Efron grade) than filcon II-3 (1.1 [±0.7]; p < 0.001) and narafilcon A (0.9 [±0.7]; p = 0.031). Time was not a significant factor for prelens tear film stability (F = 0.594, p = 0.555) or TMH (F = 0.632, p = 0.534). Lens brand did not affect temperature (F = 1.220, p = 0.308), but it decreased toward the end of the day (F = 19.497, p < 0.001). Comfort, quality of vision, visual acuity and contrast acuity, and limbal grading were similar between the lens brands but decreased with time during the day (p < 0.05). CONCLUSIONS: The tear breakup time over the contact lens surface differed between lens types and may have a role in protecting the ocular surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Keratoconus is a bilateral degenerative disease characterized by a non-inflammatory, progressive central corneal ectasia (typically asymmetric) and decreased vision. In its early stages it may be managed with spectacles and soft contact lenses but more commonly it is managed with rigid contact lenses. In advanced stages, when contact lenses can no longer be fit, have become intolerable, or corneal damage is severe, a penetrating keratoplasty is commonly performed. Alternative surgical techniques, such as the use of intra-stromal corneal ring segments (INTACS) have been developed to try and improve the fit of rigid contact lenses in keratoconic patients and avoid penetrating keratoplasties. This case report follows through the fitting of rigid contact lenses in an advanced keratoconic cornea after an INTACS procedure and discusses clinical findings, treatment options, and the use of mini-scleral and scleral lens designs as they relate to the challenges encountered in managing such a patient. Mini-scleral and scleral lenses are relatively easy to fit, and can be of benefit to many patients, including advanced keratoconic patients, post-INTAC patients and post-penetrating keratoplasty patients. © 2011 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the compliance of Daily Disposable Contact Lenses (DDCLs) wearers with replacing lenses at a manufacturer-recommended replacement frequency. To evaluate the ability of two different Health Behavioural Theories (HBT), The Health Belief Model (HBM) and The Theory of Planned Behaviour (TPB), in predicting compliance. Method: A multi-centre survey was conducted using a questionnaire completed anonymously by contact lens wearers during the purchase of DDCLs. Results: Three hundred and fifty-four questionnaires were returned. The survey comprised 58.5% females and 41.5% males (mean age 34. ±. 12. years). Twenty-three percent of respondents were non-compliant with manufacturer-recommended replacement frequency (re-using DDCLs at least once). The main reason for re-using DDCLs was "to save money" (35%). Predictions of compliance behaviour (past behaviour or future intentions) on the basis of the two HBT was investigated through logistic regression analysis: both TPB factors (subjective norms and perceived behavioural control) were significant (p. <. 0.01); HBM was less predictive with only the severity (past behaviour and future intentions) and perceived benefit (only for past behaviour) as significant factors (p. <. 0.05). Conclusions: Non-compliance with DDCLs replacement is widespread, affecting 1 out of 4 Italian wearers. Results from the TPB model show that the involvement of persons socially close to the wearers (subjective norms) and the improvement of the procedure of behavioural control of daily replacement (behavioural control) are of paramount importance in improving compliance. With reference to the HBM, it is important to warn DDCLs wearers of the severity of a contact-lens-related eye infection, and to underline the possibility of its prevention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A healthy human would be expected to show periodic blinks, making a brief closure of the eyelids. Most blinks are spontaneous, occurring regularly with no external stimulus. However a reflex blink can occur in response to external stimuli such as a bright light, a sudden loud noise, or an object approaching toward the eyes. A voluntary or forced blink is another type of blink in which the person deliberately closes the eyes and the lower eyelid raises to meet the upper eyelid. A complete blink, in which the upper eyelid touches the lower eyelid, contributes to the health of ocular surface by providing a fresh layer of tears as well as maintaining optical integrity by providing a smooth tear film over the cornea. The rate of blinking and its completeness vary depending on the task undertaken during blink assessment, the direction of gaze, the emotional state of the subjects and the method under which the blink was measured. It is also well known that wearing contact lenses (both rigid and soft lenses) can induce significant changes in blink rate and completeness. It is been established that efficient blinking plays an important role in ocular surface health during contact lens wear and for improving contact lens performance and comfort. Inefficient blinking during contact lens wear may be related to a low blink rate or incomplete blinking and can often be a reason for dry eye symptoms or ocular surface staining. It has previously been shown that upward gaze can affect blink rate, causing it to become faster. In the first experiment, it was decided to expand on previous studies in this area by examining the effect of various gaze directions (i.e. upward gaze, primary gaze, downward gaze and lateral gaze) as well as head angle (recumbent position) on normal subjects’ blink rate and completeness through the use of filming with a high-speed camera. The results of this experiment showed that as the open palpebral aperture (and exposed ocular surface area) increased from downward gaze to upward gaze, the number of blinks significantly increased (p<0.04). Also, the size of closed palpebral aperture significantly increased from downward gaze to upward gaze (p<0.005). A weak positive correlation (R² = 0.18) between the blink rate and ocular surface area was found in this study. Also, it was found that the subjects showed 81% complete blinks, 19% incomplete blinks and 2% of twitch blinks in primary gaze, consistent with previous studies. The difference in the percentage of incomplete blinks between upward gaze and downward gaze was significant (p<0.004), showing more incomplete blinks in upward gaze. The findings of this experiment suggest that while blink rate becomes slower in downward gaze, the completeness of blinking is typically better, thereby potentially reducing the risk of tear instability. On the other hand, in upward gaze while the completeness of blinking becomes worse, this is potentially offset by increased blink frequency. In addition, blink rate and completeness were not affected by lateral gaze or head angle, possibly because these conditions have similar size of the open palpebral aperture compared with primary gaze. In the second experiment, an investigation into the changes in blink rate and completeness was carried out in primary gaze and downward gaze with soft and rigid contact lenses in unadapted wearers. Not surprisingly, rigid lens wear caused a significant increase in the blink rate in both primary (p<0.001) and downward gaze (p<0.02). After fitting rigid contact lenses, the closed palpebral aperture (blink completeness) did not show any changes but the open palpebral aperture showed a significant narrowing (p<0.04). This might occur from the subjects’ attempt to avoid interaction between the upper eyelid and the edge of the lens to minimize discomfort. After applying topical anaesthetic eye drops in the eye fitted with rigid lenses, the increased blink rate dropped to values similar to that before lens insertion and the open palpebral aperture returned to baseline values, suggesting that corneal and/or lid margin sensitivity was mediating the increased blink rate and narrowed palpebral aperture. We also investigated the changes in the blink rate and completeness with soft contact lenses including a soft sphere, double slab-off toric design and periballast toric design. Soft contact lenses did not cause any significant changes in the blink rate, closed palpebral aperture, open palpebral aperture and the percentage of incomplete blinks in either primary gaze or downward gaze. After applying anaesthetic eye drops, the blink rate reduced in both primary gaze and downward gaze, however this difference was not statistically significant. The size of the closed palpebral aperture and open palpebral aperture did not show any significant changes after applying anaesthetic eye drops. However it should be noted that the effects of rigid and soft contact lenses that we observed in these studies were only the immediate reaction to contact lenses and in the longer term, it is likely that these responses will vary as the eye adapts to the presence of the lenses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ever since sodium fluorescein (‘fluorescein’ [FL]) was first used to investigate the ocular surface over a century ago, the term ‘staining’ has been taken to mean the presence of ocular surface fluorescence [1]. This term has not been necessarily taken to infer any particular mechanism of causation, and indeed, can be attributed to a variety of possible aetiologies [2]. In recent times, there has been considerable interest in a form of ocular surface fluorescence seen in association with the use of certain combinations of soft contact lenses and multipurpose solutions. The first clinical account of this phenomenon was reported by Jones et al. [3], which was followed by a more formal investigation by the same author in 2002 [4]. Jones et al described this appearance as a ‘classic solution-based toxicity reaction’. Subsequently, this appearance has come to be known as ‘solution-induced corneal staining’ or more recently by the acronym ‘SICS’ [5]. The term SICS is potentially problematic in that from a cell biology point of view, there is an inference that ‘staining’ means the entry of a dye into corneal epithelial cells. Morgan and Maldonado-Codina [2] noted there was no foundation of solid scientific literature underpinning our understanding of the true basic causative mechanisms of this phenomenon; since that time, further work has been published in this field [6] and [7] but questions still remain about the precise aetiology of this phenomenon...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Has the 1998 prediction of a well-known contact lens researcher – that rigid contact lenses will be obsolete by the year 2010 – come to fruition? This Eulogy to RGPs will demonstrate why it has. A recent survey of international contact lens prescribing trends shows that rigid lenses constituted less than 5% of all contact lenses prescribed in 16 out of 27 nations surveyed. This compares with rigid lenses representing 100% of all lenses prescribed 1965 and about 40% in 1990). With the wide range of sophisticated soft lens materials available today, including super-permeable silicone hydrogels, and designs capable of correcting astigmatism and presbyopia, there is now no need to fit cosmetic patients with rigid lenses, with the associated intractable problems of rigid lens-induced ptosis, 3 and 9 o’clock, staining, lens binding, corneal warpage and adaptation discomfort. Orthokeratology is largely a fringe application of marginal efficacy, and the notion that rigid lenses arrest myopia progression is flawed. That last bastion of rigid lens practice – fitting patients with severely distorted corneas as in keratoconus – is about to crumble in view of a number of demonstrations by independent research groups of the efficacy of custom-designed wavefront-corrected soft contact lenses for the correction of keratoconus. It is concluded that rigid contact lenses now have no place in modern contact lens practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.