Resumo:
The gracilis free flap is a workhorse in plastic surgery. We present a modified technique that relies on a single horizontal thigh-lift-type approach, which (1) gives wide pedicle exposure, (2) provides material for skin grafting, and (3) allows for distal flap transection without an additional incision. Eighteen gracilis free flaps were performed from 2007 to 2009 for lower extremity reconstruction. Complete flap survival was observed in 17 patients with one partial necrosis distally. Our approach allowed access to divide the distal gracilis tendon without a second incision in all cases. The mean scar length was 16 ± 3 cm and no hypertrophic scars were observed. In 15 patients, no visible scar was observed in the upright position, and in three patients, the scar was visible dorsally (2 ± 1 cm). No sensory deficits were observed 6 months postoperatively. In addition, the split-thickness skin graft harvested from the skin paddle was sufficient to cover all defects.
Resumo:
PURPOSE OF REVIEW: The article reviews recent significant advances and current applications of the temporoparietal fascia flap (TPFF) in head and neck surgery. RECENT FINDINGS: The recent literature describes a wide span of new applications of the TPFF in many areas. Significant developments and refinements in the reconstruction of orbitomaxillary composite defects and orbital exenteration cavities are reported. The TPFF combined with alloplastic framework is gaining in importance in external ear reconstruction. Innovative prefabricated skin or soft-tissue grafts based on the TPFF are used to restore facial contour or in the reconstruction of complex facial defects. The free TPFF finds a role in laryngotracheal reconstruction as a vascular carrier to support cartilage grafts. SUMMARY: Owing to its reliability and unequalled structural properties, the TPFF still plays a central role in facial reconstruction. Future investigation will likely incorporate the free TPFF as a vascular carrier of bioengineered tissues, such as cartilage and mucosa, for various head and neck indications.
Resumo:
Type 1 diabetic patients depend on external insulin delivery to keep their blood glucose within near-normal ranges. In this work, two robust closed-loop controllers for blood glucose regulation are developed to prevent the life-threatening hypoglycemia, as well as to avoid extended hyperglycemia. The proposed controllers are designed by using the sliding mode control technique in a Smith predictor structure. To improve meal disturbance rejection, a simple feedforward controller is added to inject meal-time insulin bolus. Simulations scenarios were used to test the controllers, and showed the controllers ability to maintain the glucose levels within the safe limits in the presence of errors in measurements, modeling and meal estimation
Resumo:
The ideal reconstruction technique for complex defects of the lower limb consists of replacing tissue with similar tissue in an attempt to achieve a good functional result. A 23-year-old white male sustained a crush injury with a grade IIIB open ankle dislocation. After open reduction and fixation, the patient developed severe osteomyelitis at the tibiotalar joint requiring a staged and radical debridement with a substantial combined soft tissue and bony defect over the distal tibia, fibula, and talus area. The reconstructive approach consisted of a modified model of the propeller flap, implementing the spare part concept in a 2-stage procedure using a prefabricated and vascularized "double-barrel" fibular graft. At 17 months postoperatively, a plain radiograph showed bony union with complete and stable coverage of the soft tissue defect. The patient was fully weightbearing. In conclusion, there is evidence to suggest that the established concept of a soft tissue propeller flap can be implemented on bone.
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
Objective: Local shockwave-application (SW) has shown to improve healing of various tissues and decrease necrosis of flaps. Though, there is no data about the optimal time-point of SW-application with regard to induction of ischemia (i.e. flap elevation) and subsequent effect on flap survival. Therefore we compared 2 shock-wave protocols in a model of persistent ischemia and investigated underlying mechanisms. Methods: 18 C57BL/6-mice equipped with a skinfold chamber containing a musculocutaneous flap were assigned to 3 experimental groups: 1. One session of 500 SWimpulses at 0·15 mJ/mm2 applied 24 hrs before (preconditioning) or 2. Applied 30 min after flap elevation (treatment). 3. Untreated flaps (control). Tissue necrosis,microhemodynamics, inflammation, apoptosis and angiogenesis were assessed by intravital epi-fluorescence microscopy over 10 days. Results: SW significantly reduced flap necrosis independent from the application time-point (preconditioning: 29 ± 7%; treatment: 25 ± 7% vs. control: 47 ± 2%; d10, p<0·05). This was associated with an early increase of functional capillary density (preconditioning: 236 ± 39 cm/cm2; treatment: 211 ± 33 cm/cm2 vs. control: 141 ± 7 cm/cm2; day1, p<0·05). Arteriolar diameter, red blood cell velocity and blood flow were comparable between the 3 experimental groups. SW-application significantly decreased the ischemiainduced inflammatory response (apoptotic cell death and leukocyte-endothelial interaction: (p<0·05)). Sprouts indicating angiogenesis were observed from day 7 only after SW-application. Conclusions: SW protects ischemically challenged musculocutaneous tissue. Interestingly, postoperative SW-application is as efficient as preoperative SWapplication. The protective effect induced by mechanical stress might be based on an early recruitment of ''sleeping capillaries'' maintaining nutritive perfusion and an anti-inflammatory effect within the ischemically jeopardized tissue. SWapplication provides a non-invasive alternative to local thermic and systemic pre-treatment of endangered tissues.
Resumo:
The aim of the study is to developa novel robust controller based on sliding mode control technique for the hydraulic servo system with flexible load and for a flexible manipulator with the lift and jib hydraulic actuators. For the purpose of general control design, a dynamic model is derived describing the principle physical behavior for both the hydraulic servo system and the flexible hydraulic manipulator. The mechanism of hydraulic servo systems is described by basic mathematical equations of fluid powersystems and the dynamics of flexible manipulator is modeled by the assumed modemethod. The controller is constructed so as to track desired trajectories in the presence of model imprecision. Experimental and simulation results demonstratethat sliding mode control has benefits which can be used to guarantee stabilityin uncertain systems and improve the system performance and load tolerance.
Resumo:
Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.
Resumo:
Objectives: This study evaluates the periodontal health status and the esthetic results of teeth subjected to orthodontic traction, after their exposure by an apically positioned flap. Study design: Fifteen patients were included in the study, ages between 11 and 28 years old. The fenestrated teeth and their homologous contralateral normally erupted teeth, used as control, were evaluated. Results: Statistically significant differences were found in the position of the gingival margin (p = 0.005), with an average distance between cemento-enamel junction (CEJ) and gingival margin of 2.47 mm (SD 1.19) in control teeth and of 1 mm (SD 1.31) in the operated teeth, and in the depth of palatal probing (p = 0.031), with 2.1 mm (SD 0.9) for the experimental teeth and 1.7 mm (SD 0.8) for the control teeth. The gingival index, the bleeding during probing and the probing depth did not show statistically significant differences. The patient"s subjective esthetic evaluation was more favorable for the control teeth in most of the cases. Conclusions: The surgical approach for the impacted teeth by means of the apically positioned flap resulted to be a predictable technique allowing the maintenance of the periodontal health on a long-term basis.
Resumo:
Extensive defects of the pelvis and genitoperineal region are a reconstructive challenge. We discuss a consecutive series of 25 reconstructions with the pedicled anterolateral thigh (ALT) flap including muscle part of the vastus lateralis (VL) in 23 patients from October 1999 to September 2012.Only surface defects larger than 100 cm and reconstructions by composite ALT + VL were included in this retrospective analysis. Of the 23 patients, 19 underwent oncologic resection, whereas 4 cases presented Fournier gangrene. Three patients did not reach 6 months of follow-up and were excluded from further data analysis. Among the remaining 20 patients (22 reconstructions), average follow-up period was 14 months (range, 10-18 months). Patient's average age was 60 years. Average size of the defect was 182 cm.Postoperative complications included 1 (4.5%) flap necrosis out of 22 raised flaps, 1 partial flap necrosis after venous congestion, and 2 cases where a complementary reconstructive procedure was performed due to remaining defect or partial flap failure. In 6 cases, peripheral wound dehiscence (27%) was treated by debridement followed by split-thickness skin graft or advancement local flaps. Defect size was significantly related to postoperative complications and increased hospital stay, especially in those patients who underwent preoperative radiotherapy. At the end of the follow-up period, a long-term and satisfactory coverage was obtained in all patients without functional deficits.This consecutive series of composite ALT + VL flap shows that, in case of extended defects, the flap provides an excellent and adjustable muscle mass, is reliable with minimal donor-site morbidity, and can even be designed as a sensate flap.
Resumo:
AIM: The study aimed to compare the rate of success and cost of anal fistula plug (AFP) insertion and endorectal advancement flap (ERAF) for anal fistula. METHOD: Patients receiving an AFP or ERAF for a complex single fistula tract, defined as involving more than a third of the longitudinal length of of the anal sphincter, were registered in a prospective database. A regression analysis was performed of factors predicting recurrence and contributing to cost. RESULTS: Seventy-one patients (AFP 31, ERAF 40) were analysed. Twelve (39%) recurrences occurred in the AFP and 17 (43%) in the ERAF group (P = 1.00). The median length of stay was 1.23 and 2.0 days (P < 0.001), respectively, and the mean cost of treatment was euro5439 ± euro2629 and euro7957 ± euro5905 (P = 0.021), respectively. On multivariable analysis, postoperative complications, underlying inflammatory bowel disease and fistula recurring after previous treatment were independent predictors of de novo recurrence. It also showed that length of hospital stay ≤ 1 day to be the most significant independent contributor to lower cost (P = 0.023). CONCLUSION: Anal fistula plug and ERAF were equally effective in treating fistula-in-ano, but AFP has a mean cost saving of euro2518 per procedure compared with ERAF. The higher cost for ERAF is due to a longer median length of stay.